An upper-body rehabilitation exoskeleton Harmony with an anatomical shoulder mechanism: Design, modeling, control, and performance evaluation
The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
We present an upper-body exoskeleton for rehabilitation, called Harmony, that provides natural coordinated motions on the shoulder with a wide range of motion, and force and impedance controllability. The exoskeleton consists of an anatomical shoulder mechanism with five active degrees of freedom, and one degree of freedom elbow and wrist mechanisms powered by series elastic actuators. The dynamic model of the exoskeleton is formulated using a recursive Newton–Euler algorithm with spatial dynamics representation. A baseline control algorithm is developed to achieve dynamic transparency and scapulohumeral rhythm assistance, and the coupled stability of the robot–human system at the baseline control is investigated. Experiments were conducted to evaluate the kinematic and dynamic characteristics of the exoskeleton. The results show that the exoskeleton exhibits good kinematic compatibility to the human body with a wide range of motion and performs task-space force and impedance control behaviors reliably.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Slotine, J.-J. E., & Li, W. (1991) · CERN Document Server (European Organization for Nuclear Research) · Cited by 18,975
Heart Disease and Stroke Statistics—2014 Update: A Report From the American Heart Association
Go, A. S., Mozaffarian, D., Roger, V. L., Benjamin, E. J., Berry, J. D., Blaha, M. J., Dai, S., Ford, E. S., Fox, C. S., Franco, S., et al. (2014) · Circulation · doi:10.1161/01.cir.0000441139.02102.80 · Cited by 5,215
Motor Control and Learning: A Behavioral Emphasis
Schmidt, R. A. (1982) · Cited by 4,770
Impedance Control: An Approach to Manipulation
Hogan, N. (1984) · 1984 American Control Conference · doi:10.23919/acc.1984.4788393 · Cited by 2,929
Robot Manipulators: Mathematics, Programming, and Control
Paul, R. P. (1981) · Cumulative Index of Computer Aided Architectural Design · Cited by 2,778
Pratt, G. A., & Williamson, M. M. (2002) · Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots · doi:10.1109/iros.1995.525827 · Cited by 2,206
Effects of Robot-Assisted Therapy on Upper Limb Recovery After Stroke: A Systematic Review
Kwakkel, G., Kollen, B. J., & Krebs, H. I. (2008) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968307305457 · Cited by 1,503
Robot-aided neurorehabilitation
Krebs, H. I., Hogan, N., Aisen, M. L., & Volpe, B. T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.662623 · Cited by 1,425
Robot-Assisted Therapy for Long-Term Upper-Limb Impairment after Stroke
Lo, A. C., Guarino, P. D., Richards, L. G., Haselkorn, J. K., Wittenberg, G. F., Federman, D. G., Ringer, R. J., Wagner, T. H., Krebs, H. I., Volpe, B. T., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0911341 · Cited by 1,397 · cited 1×
“Still, the success of robotic systems in delivering therapy after a neurological disorder is limited (Byl et al., 2013; KlamrothMarganska et al., 2014; Lo et al., 2010; Milot et al., 2013).”
BackgroundMotor learning: its relevance to stroke recovery and neurorehabilitation
Krakauer, J. W. (2006) · Current Opinion in Neurology · doi:10.1097/01.wco.0000200544.29915.cc · Cited by 1,275
Upper-Limb Powered Exoskeleton Design
Perry, J. C., Rosen, J., & Burns, S. (2007) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2007.901934 · Cited by 1,023
Prevalence and most common causes of disability among adults--United States, 2005.
Brault, M. W., Hootman, J., Helmick, C. G., Theis, K. A., & Armour, B. S. (2009) · MMWR Morbidity and Mortality Weekly Report · Cited by 971
Prange, G. B., Jannink, M. J. A., Groothuis-Oudshoorn, C. G. M., Hermens, H. J., & IJzerman, M. J. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.04.0076 · Cited by 917
Featherstone, R. (1987) · Springer eBooks · doi:10.1007/978-0-387-74315-8 · Cited by 875
Joint Structure and Function: A Comprehensive Analysis
Levangie, P. K., & Norkin, C. C. (2006) · Medical Entomology and Zoology · Cited by 868
Dynamic interactions between limb segments during planar arm movement
Hollerbach, J. M., & Flash, T. (1982) · Biological Cybernetics · doi:10.1007/bf00353957 · Cited by 814
Whitall, J., Waller, S. M., Silver, K. H. C., & Macko, R. F. (2000) · Stroke · doi:10.1161/01.str.31.10.2390 · Cited by 621
New England Journal of Medicine
(2010) · Wilderness & Environmental Medicine · doi:10.1016/j.wem.2010.09.014 · Cited by 602
Robust control of dynamically interacting systems
COLGATE, J. E., & HOGAN, N. (1988) · International Journal of Control · doi:10.1080/00207178808906161 · Cited by 589
ARMin III – Arm Therapy Exoskeleton with an Ergonomic Shoulder Actuation
Nef, T., Guidali, M., & Riener, R. (2009) · Applied Bionics and Biomechanics · doi:10.1080/11762320902840179 · Cited by 522
Klamroth-Marganska, V., Blanco, J., Campen, K., Curt, A., Dietz, V., Ettlin, T., Felder, M., Fellinghauer, B., Guidali, M., Kollmar, A., et al. (2014) · The Lancet Neurology · doi:10.1016/s1474-4422(13)70305-3 · Cited by 522
Patton, J. L., Stoykov, M. E., Kovic, M., & Mussa-Ivaldi, F. A. (2006) · Experimental Brain Research · doi:10.1007/s00221-005-0097-8 · Cited by 469 · cited 2×
“, 2004) and force fieldbased trainings (Banala et al., 2007; Patton et al., 2006).”
BackgroundImpedance Control: An Approach to Manipulation: Part III—Applications
Hogan, N. (1985) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3140701 · Cited by 452
Compliant actuation of rehabilitation robots
Vallery, H., Veneman, J., van Asseldonk, E., Ekkelenkamp, R., Buss, M., & van Der Kooij, H. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927689 · Cited by 448
A New Actuation Approach for Human Friendly Robot Design
Zinn, M., Roth, B., Khatib, O., & Salisbury, J. K. (2004) · The International Journal of Robotics Research · doi:10.1177/0278364904042193 · Cited by 441
Kong, K., Bae, J., & Tomizuka, M. (2009) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2008.2004561 · Cited by 426
Design and Control Considerations for High-Performance Series Elastic Actuators
Paine, N., Oh, S., & Sentis, L. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2270435 · Cited by 405
The Motor System Does Not Learn the Dynamics of the Arm by Rote Memorization of Past Experience
Conditt, M. A., Gandolfo, F., & Mussa-Ivaldi, F. A. (1997) · Journal of Neurophysiology · doi:10.1152/jn.1997.78.1.554 · Cited by 401
Kinematic Design to Improve Ergonomics in Human Machine Interaction
Schiele, A., & van der Helm, F. C. T. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.881565 · Cited by 386
Development and Control of a ‘Soft-Actuated’ Exoskeleton for Use in Physiotherapy and Training
Tsagarakis, N. G., & Caldwell, D. G. (2003) · Autonomous Robots · doi:10.1023/a:1024484615192 · Cited by 335 · cited 1×
“Email: bskim@utexas.edu of the shoulder girdle (Garrec et al., 2008; Klein et al., 2008; Perry et al., 2007; Tsagarakis and Caldwell, 2003; Vertechy et al., 2009).”
Controlling impedance at the man/machine interface
Hogan, N. (2003) · Proceedings, 1989 International Conference on Robotics and Automation · doi:10.1109/robot.1989.100210 · Cited by 334
Cognitive Effort and Motor Learning
Lee, T. D., Swinnen, S. P., & Serrien, D. J. (1994) · Quest · doi:10.1080/00336297.1994.10484130 · Cited by 329 · cited 1×
“Many studies suggest that the voluntary effort of patients during therapeutic movements facilitates the relearning process of the lost motor function (Conditt et al., 1997; Krakauer, 2006; Lee et al., 1994; Schmidt and Lee, 1988).”
BackgroundActive Leg Exoskeleton (ALEX) for Gait Rehabilitation of Motor-Impaired Patients
Banala, S. K., Agrawal, S. K., & Scholz, J. P. (2007) · 2007 IEEE 10th International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428456 · Cited by 316
Paul, R. P. (1981) · CERN Document Server (European Organization for Nuclear Research) · Cited by 294
Robot-assisted movement training for the stroke-impaired arm: Does it matter what the robot does?
Kahn, L. E., Lum, P. S., Rymer, W. Z., & Reinkensmeyer, D. J. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.03.0056 · Cited by 274
Bilateral arm training: Why and who benefits?
Waller, S. M., & Whitall, J. (2008) · NeuroRehabilitation · doi:10.3233/nre-2008-23104 · Cited by 253
Self-Aligning Exoskeleton Axes Through Decoupling of Joint Rotations and Translations
Stienen, A. H. A., Hekman, E. E. G., van der Helm, F. C. T., & van der Kooij, H. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2019147 · Cited by 249
Bilateral movement training and stroke rehabilitation: A systematic review and meta-analysis
Stewart, K. C., Cauraugh, J. H., & Summers, J. J. (2006) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2006.01.005 · Cited by 216
Is robot-aided sensorimotor training in stroke rehabilitation a realistic option?
Volpe, B. T., Krebs, H. I., & Hogan, N. (2001) · Current Opinion in Neurology · doi:10.1097/00019052-200112000-00011 · Cited by 209
MEDARM: a rehabilitation robot with 5DOF at the shoulder complex
Ball, S. J., Brown, I. E., & Scott, S. H. (2007) · 2007 IEEE/ASME international conference on advanced intelligent mechatronics · doi:10.1109/aim.2007.4412446 · Cited by 188
Design of an arm exoskeleton with scapula motion for shoulder rehabilitation
Roderick, S., Liszka, M., & Carignan, C. (2005) · ICAR '05. Proceedings., 12th International Conference on Advanced Robotics, 2005. · doi:10.1109/icar.2005.1507459 · Cited by 178
ABLE, an innovative transparent exoskeleton for the upper-limb
Garrec, P., Friconneau, J. P., Measson, Y., & Perrot, Y. (2008) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2008.4651012 · Cited by 175
Cauraugh, J. H., Lodha, N., Naik, S. K., & Summers, J. J. (2010) · Human Movement Science · doi:10.1016/j.humov.2009.09.004 · Cited by 170
A Pneumatic Robot for Re-Training Arm Movement after Stroke: Rationale and Mechanical Design
Sanchez, R. J., Wolbrecht, E. T., Smith, R. A., Liu, J., Rao, S. M., Cramer, S. C., Rahman, T., Bobrow, J. E., & Reinkensmeyer, D. J. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1501151 · Cited by 144
Ren, Y., Park, H., & Zhang, L. (2009) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2009.5209482 · Cited by 143
Milot, M.-H., Spencer, S. J., Chan, V., Allington, J., Klein, J., Chou, C., Bobrow, J. E., Cramer, S. C., & Reinkensmeyer, D. J. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-112 · Cited by 142
Therapeutic Robotics: A Technology Push
Krebs, H. I., & Hogan, N. (2006) · Proceedings of the IEEE · doi:10.1109/jproc.2006.880721 · Cited by 138
Dromerick, A. W., Edwards, D. F., & Kumar, A. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.10.051 · Cited by 122
Domo: a force sensing humanoid robot for manipulation research
Edsinger, A., & Weber, J. (2005) · IEEE-RAS International Conference on Humanoid Robots (Humanoids) · doi:10.1109/ichr.2004.1442127 · Cited by 106
Byl, N. N., Abrams, G., Pitsch, E. A., Fedulow, I., Kim, H., Simkins, M., Nagarajan, S. S., & Rosén, J. (2013) · Journal of Hand Therapy · doi:10.1016/j.jht.2013.06.001 · Cited by 102
Biomimetic orthosis for the neurorehabilitation of the elbow and shoulder (BONES)
Klein, J., Spencer, S. J., Allington, J., Minakata, K., Wolbrecht, E. T., Smith, R. A., Bobrow, J. E., & Reinkensmeyer, D. J. (2008) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2008.4762866 · Cited by 99
Development of a new exoskeleton for upper limb rehabilitation
Vertechy, R., Frisoli, A., Dettori, A., Solazzi, M., & Bergamasco, M. (2009) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2009.5209502 · Cited by 64
Controls for the shoulder mechanism of an upper-body exoskeleton for promoting scapulohumeral rhythm
Kim, B., & Deshpande, A. D. (2015) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2015.7281255 · Cited by 60
Self-citationCombs, S. A., Kelly, S. P., Barton, R., Ivaska, M., & Nowak, K. (2009) · Disability and Rehabilitation · doi:10.3109/09638280903242716 · Cited by 57
Repeat Therapy for Chronic Motor Stroke: A Pilot Study for Feasibility and Efficacy
Rijntjes, M., Haevernick, K., Barzel, A., van den Bussche, H., Ketels, G., & Weiller, C. (2008) · Neurorehabilitation and neural repair · doi:10.1177/1545968308324226 · Cited by 30
Exoskeletal spine and shoulder girdle for full body exoskeletons with human versatility
Taal, S. R., & Sankai, Y. (2011) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2011.5979863 · Cited by 9
Cited by
A Review on Design of Upper Limb Exoskeletons
Gull, M. A., Bai, S., & Bak, T. (2020) · Robotics · doi:10.3390/robotics9010016 · Cited by 435
Bio-inspired upper limb soft exoskeleton to reduce stroke-induced complications
Li, N., Yang, T., Yu, P., Chang, J., Zhao, L., Zhao, X., Elhajj, I. H., Xi, N., & Liu, L. (2018) · Bioinspiration & Biomimetics · doi:10.1088/1748-3190/aad8d4 · Cited by 92
Metadata
- Authors
- Kim, B., & Deshpande, A. D.
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2017-04
- Volume
- 36
- Issue
- 4
- Pages
- 414-435
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2613959249
- Cited by
- 309
- References
- 56
- FWCI
- 7.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.