A Steady-Hand Robotic System for Microsurgical Augmentation
The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
This paper reports the development of a robotic system designed to extend a human’s ability to perform small-scale (sub-millimeter) manipulation tasks requiring human judgment, sensory integration, and hand-eye coordination. Our novel approach, which we call steady-hand micromanipulation, is for tools to be held simultaneously both by the operator’s hand and a specially designed actively controlled robot arm. The robot’s controller senses forces exerted by the operator on the tool and by the tool on the environment, and uses this information in various control modes to provide smooth, tremor-free, precise positional control and force scaling. Our goal is to develop a manipulation system with the precision and sensitivity of a machine, but with the manipulative transparency and immediacy of hand-held tools for tasks characterized by compliant or semi-rigid contacts with the environment.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the 'steady-hand' approach of Taylor et al. [6], in which a robotic arm and the surgeon's hand hold the same instrument simultaneously, the robot sensing the force applied by the human hand and selectively complying in order to suppress unwanted components while allowing the desired movement.”
From Toward active tremor canceling in handheld microsurgical instruments (2003) · cites this paper as [6]
Citations
Cites
A telerobotic assistant for laparoscopic surgery
Taylor, R. H., Funda, J., Eldridge, B., Gomory, S., Gruben, K., LaRose, D., Talamini, M., Kavoussi, L., & Anderson, J. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.391776 · Cited by 392
Self-citationAn image-directed robotic system for precise orthopaedic surgery
Taylor, R. H., Mittelstadt, B. D., Paul, H. A., Hanson, W., Kazanzides, P., Zuhars, J. F., Williamson, B., Musits, B. L., Glassman, E., & Bargar, W. L. (1994) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.294202 · Cited by 347
Self-citationEj, L. (1997) · PubMed · Cited by 326
Space Robotics: Dynamics and Control
(1993) · The Kluwer International Series in Engineering and Computer Science · doi:10.1007/978-1-4615-3588-1 · Cited by 263 · cited 1×
“[17-19]); and 3) master-slave teleoperators (e.g., [ 20-22 ]).”
Tactile Display of Vibratory Information in Teleoperation and Virtual Environments
Kontarinis, D. A., & Howe, R. D. (1995) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.1995.4.4.387 · Cited by 251 · cited 1×
“We have begun preliminary experiments with vibrotactile displays (Kontarinis and Howe 1995).”
Teleoperation, telerobotics and telepresence: A progress report
Sheridan, T. B. (1995) · Control Engineering Practice · doi:10.1016/0967-0661(94)00078-u · Cited by 243
Comparative experiments with a new adaptive controller for robot arms
Whitcomb, L. L., Rizzi, A. A., & Koditschek, D. E. (1993) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.210795 · Cited by 236
Self-citationA modular surgical robotic system for image guided percutaneous procedures
Stoianovici, D., Whitcomb, L. L., Anderson, J. H., Taylor, R. H., & Kavoussi, L. R. (1998) · Lecture Notes in Computer Science · doi:10.1007/bfb0056225 · Cited by 174 · cited 1×
“We have applied the RCM in conjunction with the PAKY needle driver for performing image guided renal access [45, 46].”
Self-citationKazerooni, H., & Guo, J. (1993) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.2899068 · Cited by 119
Modeling and canceling tremor in human-machine interfaces
Riviere, C. N., & Thakor, N. V. (1996) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.499755 · Cited by 114 · cited 2×
“Our immediate goal is a rigorous evaluation of the completed system as a microsurgery augmentation aid, using test environments developed by our colleagues at JHU’s Wilmer Eye Institute and CMU (Humayun et al. 1997; Riviere and Thakor 1996; Riviere and Khosla 1999a, 1999b).”
Research works printed but not linked: 10
- Bargar, W., etal. 1995 (Baltimore, MD). Robodoc Multicenter trial: An interim report . Proc. of the 2nd Intl. Symp. on Medical Robot. and Comp.Assisted Surgery, MRCAS ’95. Pittsburgh, PA: C/O Center for Orthop. Res., Shadyside Hospital.
- Charles, S. 1994. Dexterity enhancement for surgery . Proc. of the First Intl. Symp. on Medical Robot. and Comp.Assisted Surgery, vol. 2, pp. 145–160 .
- Cho, Y., Kotoku, T., and Tanie, K. 1995 (Pittsburgh, PA). Discrete-event-planning and control of telerobotic part mating process with communication delay in geometric uncertainty . Proc. of the IEEE Conf. on Intell. Robot. and Sys. Washington, DC: IEEE Press.
- Dinsmoor, C., and Hagermann, P. 1993 (Detroit, MI). Fanuc robotics system r-j controller . Proc. of the Intl. Robots and Vision Automat. Conf.
- Funda, J., et al. 1994. Image-guided command and control of a surgical robot . Proc. Med. Meets Virtual Reality II. San Diego, CA.
- Kazerooni, H. 1989b. Human/robot interaction via the transfer of power and information signals—part II: Dynamics and control analysis. Proc. of the IEEE Conf. on Robot. and Automat. Los Alamitos, CA: IEEE .
- Kumar, R., et al. 1997 (Tokyo, Japan). Robot-assisted microneurosurgical procedures, comparative dexterity experiments . Proc. of the Society for Minimally Invasive Therapy, 9th Annual Meeting, abstract book vol. 6, suppl. 1.
- Mindell, D. A., et al. 1993. JasonTalk: A standard ROV vehicle control system. Proc. of IEEE/MTS OCEANS’93. Los Alamitos, CA: IEEE .
- Mittelstadt, B. D., et al. 1994. The evolution of a surgical robot from prototype to human clinical trial . Proc. of the Intl. Symp. on Medical Robot. and Comp.Assisted Surgery. Pittsburgh, PA.
- Stoianovici, D., et al. 1998. A modular surgical robotic system for image-guided percutaneous procedures. Medical Image Computing and Comp.Assisted Interventions (MICCAI-98). 1998. Cambridge, MA: Springer . · DOI · Paper page
Cited by
Items 301–400 of 528
Eye Explorer: A robotic endoscope holder for eye surgery
Zhou, D., Kimura, S., Takeyama, H., Haraguchi, D., Kaizu, Y., Nakao, S., Sonoda, K., & Tadano, K. (2020) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.2177 · Cited by 10
Zhen, S., Li, R., Liu, X., & Chen, Y. (2023) · Measurement Science and Technology · doi:10.1088/1361-6501/ad179d · Cited by 10
A haptic guidance tool for CT-directed percutaneous interventions
Hagmann, E., Rouiller, P., Helmer, P., Grange, S., & Baur, C. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1403786 · Cited by 9
Precision experiments on a comanipulated robotic system for use in retinal surgery
Caers, P., Gijbels, A., Volder, M. F. L. D., Gorissen, B., Stalmans, P., Reynaerts, D., & Poorten, E. V. (2011) · Lirias · Cited by 9
EyeSAM: graph-based localization and mapping of retinal vasculature during intraocular microsurgery
Mukherjee, S., Kaess, M., Martel, J. N., & Riviere, C. N. (2019) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-019-01925-1 · Cited by 9
Ding, A. S., Capostagno, S., Razavi, C. R., Li, Z., Taylor, R. H., Carey, J. P., & Creighton, F. X. (2021) · Otology & Neurotology · doi:10.1097/mao.0000000000003309 · Cited by 9
Self-citationAn Open-Source Platform for Cooperative, Semi-Autonomous Robotic Surgery
Connolly, L., Deguet, A., Sunderland, K., Lassó, A., Ungi, T., Rudan, J. F., Taylor, R. H., Mousavi, P., & Gabor Fichtinger, A. (2021) · IEEE International Conference on Autonomous Systems (ICAS) · doi:10.1109/icas49788.2021.9551149 · Cited by 9
Self-citationCardiac interventions under MRI guidance using robotic assistance
Li, M., Kapoor, A., Mazilu, D., Wood, B. J., & Horvath, K. A. (2010) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2010.5509151 · Cited by 9
Improved Active Handrest Performance Through Use of Virtual Fixtures
Fehlberg, M. A., Nisky, I., Doxon, A. J., & Provancher, W. R. (2014) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2014.2321531 · Cited by 9
CT fluoroscopy-guided robotically-assisted lung biopsy
Xu, S. Y., Gabor Fichtinger, A., Taylor, R. H., Banovac, F., & Cleary, K. (2006) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.652882 · Cited by 9
Self-citationTactile Feedback in Surgical Robotics
Culjat, M. O., Bisley, J. W., King, C., Wottawa, C. R., Fan, R. E., Dutson, E., & Grundfest, W. S. (2010) · Springer eBooks · doi:10.1007/978-1-4419-1126-1_19 · Cited by 15
Task modeling and specification for modular sensory based human-machine cooperative systems
Kragić, D., & Hager, G. D. (2004) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2003.1249648 · Cited by 9
Composite Configuration Interventional Therapy Robot for the Microwave Ablation of Liver Tumors
Cao, Y., Xue, L., Qi, B., Jiang, L., Deng, S., Liang, P., & Liu, J. (2017) · Chinese Journal of Mechanical Engineering · doi:10.1007/s10033-017-0141-1 · Cited by 9
Challenges in Computer Assisted Interventions
Stefan, P., Traub, J., Hennersperger, C., Esposito, M., & Navab, N. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-816176-0.00045-4 · Cited by 10
Effect of Hand Dynamics on Virtual Fixtures for Compliant Human-Machine Interfaces
Marayong, P., Hager, G. D., & Okamura, A. M. (2006) · Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems · doi:10.1109/haptic.2006.1627075 · Cited by 9
Cossetto, T., Zareinia, K., & Sutherland, G. R. (2012) · Elsevier eBooks · doi:10.1533/9780857097392.59 · Cited by 9
Test of Tracing Performance with an Active Handheld Micromanipulator
Choi, D. Y., Sandoval, R., MacLachlan, R. A., Ho, L., Lobes, L. A., & Riviere, C. N. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353119 · Cited by 10
Rate-dependent inverse hysteresis feedforward controller for microsurgical tool
Garmon, F. A., Ang, W. T., Khosla, P. K., & Riviere, C. N. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280879 · Cited by 10
Robotic Assistant Systems for Otolaryngology-Head and Neck Surgery
Olds, K. C. (2015) · Cited by 14
Force-reflecting teleoperation over wide-area networks
Polouchine, I. (2009) · Carleton University's Institutional Repository (MacOdrum Library, Carleton University) · doi:10.22215/etd/2009-06337 · Cited by 14
Patel, N. A., Urias, M. G., Ebrahimi, A., Taylor, R. H., Gehlbach, P. L., & Iordachita, I. I. (2022) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2022.3191441 · Cited by 11
Self-citationSensitivity analysis of a double-parallelogram based RCM mechanism used for MIS robots
Singh, A., & Khatait, J. P. (2023) · Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science · doi:10.1177/09544062231153818 · Cited by 8
“23,24 Further, some of the other RCM devices, 5,25–31 not based on the parallelogram motion, were reported as well.”
Low-Profile 6-Axis Differential Magnetic Force/Torque Sensing
Black, D., Hosseinabadi, A. H. H., Pradnyawira, N. R., Nogami, M., & Salcudean, S. E. (2024) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2024.3407350 · Cited by 8
“Having different numbers of neurons in each layer was also tested, for example having [50 , 150 , 256 , 150 , 50], but the performance was consistently worse.”
Is it possible to use robots for carpal tunnel release?
Guldmann, R., Pourtales, M. C., & Liverneaux, P. A. (2010) · Journal of Orthopaedic Science · doi:10.1007/s00776-009-1450-8 · Cited by 8
Robotic Surgery in Ophthalmology
Tsirbas, A., Mango, C., & Hubschman, J. (2007) · Springer eBooks · doi:10.1007/978-3-540-72999-0_10 · Cited by 8
Design of a positioning system for a holographic otoscope
Dobrev, I., Moreno, J. M. F., Furlong, C., Harrington, E., Rosowski, J. J., & Scarpino, C. (2010) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.862354 · Cited by 8
Design and optimization of manipulator for laparoscopic minimally invasive surgical robotic system
Ma, R., Wang, W., Du, Z., & Li, G. (2012) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2012.6283175 · Cited by 8
A model of motor performance during surface penetration: from physics to voluntary control
Klatzky, R. L., Gershon, P., Shivaprabhu, V., Lee, R., Wu, B., Stetten, G., & Swendsen, R. H. (2013) · Experimental Brain Research · doi:10.1007/s00221-013-3648-4 · Cited by 9
“Several research groups, including the present authors, have developed devices to amplify forces during surgery (Stetten et al. 2011; Salcudean and Yan 1994; Taylor et al. 1999; Fleming et al. 2008).”
Hand-guiding robots along predefined geometric paths under hard joint constraints
Hanses, M., Behrens, R., & Elkmann, N. (2016) · IEEE International Conference on Emerging Technologies and Factory Automation (ETFA) · doi:10.1109/etfa.2016.7733600 · Cited by 8
Pillai, B. M., Wilasrusmee, C., & Suthakorn, J. (2020) · International Journal of Electrical and Computer Engineering (IJECE) · doi:10.11591/ijece.v10i1.pp828-839 · Cited by 8
Modelling of needle insertion forces for surgical simulation
Yang, H. Y., Liu, P. X., & Zhang, J. (2006) · International Conference on Mechatronics and Automation · doi:10.1109/icma.2005.1626616 · Cited by 8
Latt, W. T., Tan, U.-X., Widjaja, F., Veluvolu, K. C., Shee, C. Y., & Ang, W. T. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649570 · Cited by 9
Stable and User-Controlled Assistance of Human Motor Function
Vallery, H. (2009) · Cited by 9
A soft micron accuracy robot design and clinical validation for retinal surgery
Chen, Y., Guo, X., Ye, X., Jiang, T., Chen, H., Yu, J., Yang, G., Knoll, A., Cui, D., Zhou, M., et al. (2025) · Microsystems & Nanoengineering · doi:10.1038/s41378-025-01002-5 · Cited by 8
“(2) Collaborative surgical robot is that the surgical instruments are controlled simultaneously by the surgeon ’ s hand and the robotic arm 20 – 22 .”
Qualitative and quantitative assessment of admittance controllers for hand-guiding surgical robots
Karnam, M. K., Cattin, P. C., Rauter, G., & Gerig, N. (2023) · at - Automatisierungstechnik · doi:10.1515/auto-2023-0063 · Cited by 7
Progress in Neurosurgical Robotics
Motkoski, J. W., & Sutherland, G. R. (2013) · Springer eBooks · doi:10.1007/978-1-4614-7657-3_46 · Cited by 8
Theoretical error analysis of spotlight-based instrument localization for retinal surgery
Zhou, M., Hennerkes, F., Liu, J., Jiang, Z., Wendler, T., Nasseri, M. A., Iordachita, I. I., & Navab, N. (2023) · Robotica · doi:10.1017/s0263574722001862 · Cited by 7
MRI Compatible Robot Systems for Medical Intervention
Li, M., Mazilu, D., Kapoor, A., & Keith, A. (2010) · InTech eBooks · doi:10.5772/9675 · Cited by 7
“Thus, it is more suited for an admittance control scheme such as those explored with the Johns Hopkins University Steady-Hand Robot (Taylor et al., 1999).”
Electromagnetic Tracking for Medical Imaging
Wen, J. (2010) · Open Scholarship Institutional Repository (Washington University in St. Louis) · doi:10.7936/k7s75dd1 · Cited by 7
Compliant Human–Robot Collaboration with Accurate Path-Tracking Ability for a Robot Manipulator
Reyes-Uquillas, D., & Hsiao, T. (2021) · Applied Sciences · doi:10.3390/app11135914 · Cited by 7
Park, H.-S., Yeo, C. B. A., Gehlbach, P. L., & Song, C. O. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318247 · Cited by 7
Scale-invariant registration of monocular stereo images to 3D surface models
Burschka, D., Li, M., Taylor, R. H., & Hager, G. D. (2005) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2004.1389797 · Cited by 7
Self-citationCISUS: an integrated 3D ultrasound system for IGT using a modular tracking API
Boctor, E. M., Viswanathan, A., Pieper, S., Choti, M. A., Taylor, R. H., Kikinis, R., & Gabor Fichtinger, A. (2004) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.537776 · Cited by 7
Self-citationPathak, A. (2010) · Deep Blue (University of Michigan) · Cited by 10
Compact sensing design of a hand-held active tremor compensation instrument for better ergonomics
Latt, W. T., Tan, U.-X., Widjaja, F., Shee, C. Y., & Ang, W. T. (2008) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2008.4762806 · Cited by 7
Tognetti, L. J. (2005) · SMARTech Repository (Georgia Institute of Technology) · Cited by 7
Assistance to laparoscopic surgery through comanipulation
Dong, L. (2017) · theses.fr (ABES) · doi:10.70675/658d1aacz8350z4742zaf54z2e13f2795b16 · Cited by 9
Exploring the Remapping Impact of Spatial Head-hand Relations in Immersive Telesurgery
Luo, T., Ke, Z., Wang, P., Chang, S.-T., Chen, G., Zhang, H., Tan, X., Wang, Q., Han, T., & Tian, F. (2025) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3706598.3714285 · Cited by 6
“This hinders surgeons’ hand-eye coordination [93] and increases their cognitive and physical load [25, 66, 86].”
Cooperative force control of a hybrid Cartesian parallel manipulator for bone slicing
Yen, P., & Hung, S. (2012) · Robotica · doi:10.1017/s0263574712000161 · Cited by 6
Inexpensive monocular pico-projector-based augmented reality display for surgical microscope
Shi, C., Becker, B. C., & Riviere, C. N. (2012) · Proceedings - IEEE Symposium on Computer-Based Medical Systems · doi:10.1109/cbms.2012.6266298 · Cited by 8
Azar, A. T., & Eljamel, S. (2012) · Advances in computational intelligence and robotics book series · doi:10.4018/978-1-4666-0176-5.ch009 · Cited by 6
Passive Virtual Fixtures Based on Simulated Position-Dependent Anisotropic Plasticity
Kikuuwe, R., Takesue, N., & FUJIMOTO, H. (2007) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2007.363976 · Cited by 6
Watanabe, T., Omata, S., Odamura, M., Okada, M., Nakamura, Y., & Yokoyama, H. (2006) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2006.07.017 · Cited by 7
Inverse Kinematic Model of Flexure-Based Microsurgical Manipulator
Avedillo, J. G., Choi, D. Y., & Riviere, C. N. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1615800 · Cited by 6
Virtual Fixture Control for Compliant Human-Machine Interfaces
Marayong, P., Na, H. S., & Okamura, A. M. (2007) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2007.364096 · Cited by 6
Yadav, J., & Suthakorn, J. (2012) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2012.6491271 · Cited by 6
Auner, G. W., & Pandya, A. D. (2004) · Cited by 6
Initial clinical use of the intraocular endoscope holding robot in pars plana vitrectomy
Kiyohara, K., Ishikawa, K., Yuge, K., Yamana, S., Nakao, S., & Sonoda, K.-H. (2025) · Japanese Journal of Ophthalmology · doi:10.1007/s10384-025-01285-1 · Cited by 6
“In ophthalmic surgery, various robotic systems have been developed, ranging from handheld stabilization devices to remote-controlled consoles [2–4].”
Design and Evaluation of an Eye Mountable AutoDALK Robot for Deep Anterior Lamellar Keratoplasty
Opfermann, J. D., Wang, Y., Kaluna, J., Suzuki, K., Gensheimer, W. G., Krieger, A., & Kang, J. U. (2024) · Micromachines · doi:10.3390/mi15060788 · Cited by 7
“…Taylor et al. first introduced the steady-hand robotic system for microsurgery, which was modified by Mitchell et al. to be used in retinal surgery [20 While using a force/torque input collected from the manual use of a surgical tool in the operating fi eld, the robot simultaneously supports the…”
A Review of Contact-Based Robotic Micromanipulation Systems: Technology and Applications
Long, Y., Weng, T., Wang, T., Li, J., Xiao, S., Li, B., & Yang, L. (2025) · Journal of Intelligent & Robotic Systems · doi:10.1007/s10846-025-02299-0 · Cited by 7
“In 1999, Taylor et al. [43] first proposed a collaborative CRMS-M, which was the prototype for the later Steady-Hand Eye Robot (SHER).”
InfluentialAnalysis of Active Handrest Control Methods
Fehlberg, M. A., Gleeson, B. T., & Provancher, W. R. (2010) · Lecture notes in computer science · doi:10.1007/978-3-642-14064-8_47 · Cited by 5
Hand position effects on precision and speed in telerobotic surgery
Golenberg, L. P., Cao, A., Ellis, R. D., Klein, M. I., Auner, G. W., & Pandya, A. K. (2007) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.148 · Cited by 5
Why Robots Entered Neurosurgery
Motkoski, J. W., & Sutherland, G. R. (2016) · Neuromethods · doi:10.1007/978-1-4939-3730-1_6 · Cited by 5
Li, H.-Y., Paranawithana, I., Yang, L., & Tan, U.-X. (2021) · IEEE International Conference on Automation Science and Engineering (CASE) · doi:10.1109/case49439.2021.9551565 · Cited by 5
Introduction and History of Robotics in Neurosurgery
Fomenko, A., Idrissi, F. E. E., Aji, N., Outani, O., Benkirane, K., Moujtahid, H., Al‐Salihi, M. M., & Serletis, D. (2022) · Springer eBooks · doi:10.1007/978-3-030-90862-1_1 · Cited by 5
ENTRI: Enhanced Navigational Toolkit for Robotic Interventions
Sahu, M., Ishida, H., Connolly, L., Fan, H.-Y., Deguet, A., Kazanzides, P., Creighton, F. X., Taylor, R. H., & Munawar, A. (2024) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2024.3475827 · Cited by 5
Self-citationMeasurement System for the Characterization of Micro-Manipulation Motion and Force
Hammond, F. L., Talbot, S. G., Wood, R. J., & Howe, R. D. (2013) · Journal of Medical Devices · doi:10.1115/1.4024524 · Cited by 5
Ren, H., & Meng, M. Q. ‐. (2011) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519411004289 · Cited by 5
Davies, B. (2003) · Minimally Invasive Therapy & Allied Technologies · doi:10.1080/13645700310001568 · Cited by 5
Cheon, G. W., Huang, Y., & Kang, J. U. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2079346 · Cited by 5
Limit-push training reduces motor variability
Sharp, I., & Patton, J. L. (2011) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975490 · Cited by 5
“MicroSurgery is another area where variability is higher than desired, due to tremor and low signal-to-noise of the system [20].”
Visual Limit-Push Training Alters Movement Variability
Hajissa, E., Shah, A. K., & Patton, J. L. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2786142 · Cited by 5
“Variability control is also of interest in microsurgery and piloting, where tremor may lead to poor performance even though the average path is accurate [6].”
Early Developments, Current Systems, and Future Directions
Sugiyama, T., Lama, S., Hoshyarmanesh, H., Baghdadi, A., & Sutherland, G. R. (2020) · Neuromethods · doi:10.1007/978-1-0716-0993-4_15 · Cited by 6
Fehlberg, M. A., King, R. J., Doxon, A. J., & Provancher, W. R. (2012) · IEEE Haptics Symposium · doi:10.1109/haptic.2012.6183802 · Cited by 5
Accurate micromanipulation induced by performing in unstable dynamics
Su, E. L. M., Ganesh, G., Yeong, C. F., & Burdet, E. (2010) · IEEE RO-MAN · doi:10.1109/roman.2010.5598674 · Cited by 6
Aye, Y. N., Zhao, S., & Ang, W. T. (2013) · International Journal of Advanced Robotic Systems · doi:10.5772/56571 · Cited by 5
Force Feedback Augmentation Modes in the Laparoscopic Minimal Invasive Telesurgical System
Pitakwatchara, P., Warisawa, S., & Mitsuishi, M. (2006) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2006.1639232 · Cited by 6
Latt, W. T., Tan, U.-X., Widjaja, F., & Ang, W. T. (2009) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2009.4913014 · Cited by 6
Motion control methods for human-machine cooperative systems
Marayong, P. (2008) · Cited by 6
Deep Learning: A Primer for Neurosurgeons
Hong-xi, Y., Yuwen, C., Cheng, X., Fan, H., Wang, X., & Ge, Z. (2024) · Advances in experimental medicine and biology · doi:10.1007/978-3-031-64892-2_4 · Cited by 5
A review of recent methods and applications of virtual fixtures in robot-assisted surgery
Mohan, D. M., Shirinzadeh, B., Smith, J. A., Zhong, Y., Turlapati, S. H., & Campolo, D. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.111294 · Cited by 4
Nabeel, M., Lee, J., Mehmood, U., Jafari, A., Hwang, J.-H., & Ryu, J.-H. (2015) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2015.7353431 · Cited by 4
Progress in clinical application of computer-assisted orthopedic surgery
Shen, H., & Liu, H. (2023) · Digital Medicine · doi:10.1097/dm-2023-00002 · Cited by 4
RCM adjustment for a double-parallelogram based RCM mechanism used for MIS robots
Singh, A., & Khatait, J. P. (2023) · Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science · doi:10.1177/09544062231185518 · Cited by 4
Tracking rotation and translation of laser microsurgical instruments
Ortiz, R., & Riviere, C. N. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280878 · Cited by 4
Configuration and Kinematic Analysis of a Novel Hybrid Surgical Robot with a Ball Joint
Diao, Y., Yao, L., Chen, Z., Jiyuan, Z., & Luo, H. (2009) · International Workshop on Intelligent Systems and Applications (ISA) · doi:10.1109/iwisa.2009.5072790 · Cited by 4
Acousto-Optic Compensation of Tremor for Use in a Handheld Laser Microsurgical Instrument
Cernat, R. C., Matei, C. E., Olteanu, L. A. M., Riviere, C. N., & Dumitraş, D. (2006) · Conference proceedings · doi:10.1109/iembs.2006.260728 · Cited by 4
A control method for time-variant RCM constraint in hands-on RAMIS procedures
Kastritsi, T., & Doulgeri, Z. (2021) · Mediterranean Conference on Control and Automation (MED) · doi:10.1109/med51440.2021.9480162 · Cited by 4
Mihelj, M., & Podobnik, J. (2012) · International series on intelligent systems, control and automation: science and engineering · doi:10.1007/978-94-007-5718-9_10 · Cited by 4
Haptic Guidance in a Collaborative Robotic System
Ribeiro, F., & Lopes, A. M. (2013) · Communications in computer and information science · doi:10.1007/978-3-642-39223-8_10 · Cited by 4
Human-micromanipulator cooperation using a variable admittance controller
Li, H.-Y., Nuradha, T., Xavier, S. A., & Tan, U.-X. (2019) · Science China Information Sciences · doi:10.1007/s11432-018-9663-1 · Cited by 5
Computer-integrated interventional medicine: A 30 year perspective
Taylor, R. H. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-816176-0.00030-2 · Cited by 5
Self-citationPayne, C. J., Dwyer, G., Dimitrakakis, E., & Marcus, H. J. (2020) · Neuromethods · doi:10.1007/978-1-0716-0993-4_1 · Cited by 4
Tremor Attenuation For Robot Teleoperation By A Broad Learning System-Based Approach
Liu, W., Lai, G., & Liu, A. (2021) · China Automation Congress (CAC) · doi:10.1109/cac53003.2021.9727960 · Cited by 4
Mechanical Design and Optimization of a Microsurgical Robot
Miroir, M., Szewczyk, J., Nguyen, Y., Mazalaigue, S., Grayeli, A. B., & Sterkers, O. (2008) · Springer eBooks · doi:10.1007/978-1-4020-8915-2_69 · Cited by 4
Gabor Fichtinger, A., Stoianovici, D. S., & Taylor, R. H. (2002) · IEEE Applied Imagery Pattern Recognition Workshop · doi:10.1109/aipr.2001.991195 · Cited by 4
Self-citationArbuckle, T. K., Nambi, M., Butner, J., Provancher, W. R., & Abbott, J. J. (2016) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2016.2599493 · Cited by 5
Preliminary Evaluation of Active Tremor Cancellation Spoon for Patients with Hand Tremor
Ripin, Z. M., Chan, P. Y., & Alisah, M. I. (2020) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/815/1/012002 · Cited by 4
Medical Robotic Systems in Computer-Integrated Surgery
Taylor, R. H., & Stoianovici, D. S. (2003) · Problems in General Surgery · doi:10.1097/01.sgs.0000081179.89384.ba · Cited by 4
Self-citationNonparametric bootstrap technique for calibrating surgical SmartForceps: theory and application
Azimaee, P., Jozani, M. J., Maddahi, Y., Zareinia, K., & Sutherland, G. R. (2017) · Expert Review of Medical Devices · doi:10.1080/17434440.2017.1378090 · Cited by 4
Metadata
- Authors
- Taylor, R., Jensen, P., Whitcomb, L., Barnes, A., Kumar, R., Stoianovici, D., Gupta, P., Wang, Z., Dejuan, E., & Kavoussi, L.
- Affiliations
- Johns Hopkins University (US)
- Wilmer Eye Institute, Johns Hopkins Medical Institutions, Johns Hopkins University, Baltimore, MD, USA
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 1999-12
- Volume
- 18
- Issue
- 12
- Pages
- 1201-1210
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2149985621
- Cited by
- 528
- References
- 43
- Citations by year
- 2026: 8 · 2025: 13 · 2024: 7 · 2023: 15 · 2022: 15 · 2021: 19 · 2020: 29 · 2019: 26 · 2018: 25 · 2017: 13 · 2016: 15 · 2015: 30 · 2014: 21 · 2013: 30 · 2012: 29
- FWCI
- 26.82
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- The International Journal of Robotics Research (publishedVersion)
- Funders
- National Science Foundation
- Johns Hopkins University
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Robot Manipulation and Learning
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Keywords
- microsurgery, force scaling, force sensing, human-robot interaction, tremor suppression, compliant manipulation, eye-hand coordination
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.