A Steady-Hand Robotic System for Microsurgical Augmentation
The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
This paper reports the development of a robotic system designed to extend a human’s ability to perform small-scale (sub-millimeter) manipulation tasks requiring human judgment, sensory integration, and hand-eye coordination. Our novel approach, which we call steady-hand micromanipulation, is for tools to be held simultaneously both by the operator’s hand and a specially designed actively controlled robot arm. The robot’s controller senses forces exerted by the operator on the tool and by the tool on the environment, and uses this information in various control modes to provide smooth, tremor-free, precise positional control and force scaling. Our goal is to develop a manipulation system with the precision and sensitivity of a machine, but with the manipulative transparency and immediacy of hand-held tools for tasks characterized by compliant or semi-rigid contacts with the environment.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the 'steady-hand' approach of Taylor et al. [6], in which a robotic arm and the surgeon's hand hold the same instrument simultaneously, the robot sensing the force applied by the human hand and selectively complying in order to suppress unwanted components while allowing the desired movement.”
From Toward active tremor canceling in handheld microsurgical instruments (2003) · cites this paper as [6]
Citations
Cites
A telerobotic assistant for laparoscopic surgery
Taylor, R. H., Funda, J., Eldridge, B., Gomory, S., Gruben, K., LaRose, D., Talamini, M., Kavoussi, L., & Anderson, J. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.391776 · Cited by 392
Self-citationAn image-directed robotic system for precise orthopaedic surgery
Taylor, R. H., Mittelstadt, B. D., Paul, H. A., Hanson, W., Kazanzides, P., Zuhars, J. F., Williamson, B., Musits, B. L., Glassman, E., & Bargar, W. L. (1994) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.294202 · Cited by 347
Self-citationEj, L. (1997) · PubMed · Cited by 326
Space Robotics: Dynamics and Control
(1993) · The Kluwer International Series in Engineering and Computer Science · doi:10.1007/978-1-4615-3588-1 · Cited by 263 · cited 1×
“[17-19]); and 3) master-slave teleoperators (e.g., [ 20-22 ]).”
Tactile Display of Vibratory Information in Teleoperation and Virtual Environments
Kontarinis, D. A., & Howe, R. D. (1995) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.1995.4.4.387 · Cited by 251 · cited 1×
“We have begun preliminary experiments with vibrotactile displays (Kontarinis and Howe 1995).”
Teleoperation, telerobotics and telepresence: A progress report
Sheridan, T. B. (1995) · Control Engineering Practice · doi:10.1016/0967-0661(94)00078-u · Cited by 243
Comparative experiments with a new adaptive controller for robot arms
Whitcomb, L. L., Rizzi, A. A., & Koditschek, D. E. (1993) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.210795 · Cited by 236
Self-citationA modular surgical robotic system for image guided percutaneous procedures
Stoianovici, D., Whitcomb, L. L., Anderson, J. H., Taylor, R. H., & Kavoussi, L. R. (1998) · Lecture Notes in Computer Science · doi:10.1007/bfb0056225 · Cited by 174 · cited 1×
“We have applied the RCM in conjunction with the PAKY needle driver for performing image guided renal access [45, 46].”
Self-citationKazerooni, H., & Guo, J. (1993) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.2899068 · Cited by 119
Modeling and canceling tremor in human-machine interfaces
Riviere, C. N., & Thakor, N. V. (1996) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.499755 · Cited by 114 · cited 2×
“Our immediate goal is a rigorous evaluation of the completed system as a microsurgery augmentation aid, using test environments developed by our colleagues at JHU’s Wilmer Eye Institute and CMU (Humayun et al. 1997; Riviere and Thakor 1996; Riviere and Khosla 1999a, 1999b).”
Research works printed but not linked: 10
- Bargar, W., etal. 1995 (Baltimore, MD). Robodoc Multicenter trial: An interim report . Proc. of the 2nd Intl. Symp. on Medical Robot. and Comp.Assisted Surgery, MRCAS ’95. Pittsburgh, PA: C/O Center for Orthop. Res., Shadyside Hospital.
- Charles, S. 1994. Dexterity enhancement for surgery . Proc. of the First Intl. Symp. on Medical Robot. and Comp.Assisted Surgery, vol. 2, pp. 145–160 .
- Cho, Y., Kotoku, T., and Tanie, K. 1995 (Pittsburgh, PA). Discrete-event-planning and control of telerobotic part mating process with communication delay in geometric uncertainty . Proc. of the IEEE Conf. on Intell. Robot. and Sys. Washington, DC: IEEE Press.
- Dinsmoor, C., and Hagermann, P. 1993 (Detroit, MI). Fanuc robotics system r-j controller . Proc. of the Intl. Robots and Vision Automat. Conf.
- Funda, J., et al. 1994. Image-guided command and control of a surgical robot . Proc. Med. Meets Virtual Reality II. San Diego, CA.
- Kazerooni, H. 1989b. Human/robot interaction via the transfer of power and information signals—part II: Dynamics and control analysis. Proc. of the IEEE Conf. on Robot. and Automat. Los Alamitos, CA: IEEE .
- Kumar, R., et al. 1997 (Tokyo, Japan). Robot-assisted microneurosurgical procedures, comparative dexterity experiments . Proc. of the Society for Minimally Invasive Therapy, 9th Annual Meeting, abstract book vol. 6, suppl. 1.
- Mindell, D. A., et al. 1993. JasonTalk: A standard ROV vehicle control system. Proc. of IEEE/MTS OCEANS’93. Los Alamitos, CA: IEEE .
- Mittelstadt, B. D., et al. 1994. The evolution of a surgical robot from prototype to human clinical trial . Proc. of the Intl. Symp. on Medical Robot. and Comp.Assisted Surgery. Pittsburgh, PA.
- Stoianovici, D., et al. 1998. A modular surgical robotic system for image-guided percutaneous procedures. Medical Image Computing and Comp.Assisted Interventions (MICCAI-98). 1998. Cambridge, MA: Springer . · DOI · Paper page
Cited by
Items 401–500 of 528
Golenberg, L. P. (2010) · Human Biology · Cited by 4
Latt, W. T., Tan, U.-X., Widjaja, F., Shee, C. Y., & Ang, W. T. (2008) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2008.4762893 · Cited by 4
SMART micro-scissors based precise incision
Park, H., Yeo, C., & Song, C. O. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2080790 · Cited by 3
Data-Driven Design of a Dexterous Robotic Microsurgery System
Hammond, F. L., Talbot, S. G., Wood, R. J., & Howe, R. D. (2012) · Journal of Medical Devices · doi:10.1115/1.4026758 · Cited by 3
Synergic comanipulation despite underactuated robot
Marx, A., Vitrani, M., Herman, B., Iordache, R., Muller, S. L., & Morel, G. (2011) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2011.5979938 · Cited by 3
Robotics for Image-Guided Neurosurgery
Lama, S., & Sutherland, G. R. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-800870-6.00019-4 · Cited by 3
Assessment and Elimination of Surgeon Hand Tremor During Robotic Surgery
Kumar, A., Kumar, S., & Kumar, A. (2023) · Springer eBooks · doi:10.1007/978-981-99-2074-7_97 · Cited by 3
A New Practical Robust Control Design for Model-based Uncertain Collaborative Robot
Zhen, S., Li, R., Liu, X., & Chen, Y. (2023) · International Conference on Advanced Robotics and Mechatronics (ICARM) · doi:10.1109/icarm58088.2023.10218755 · Cited by 3
Configuration design and prototype development of a remote-centered parallel welding robot
Wen, S., Qin, G., Che, L., Wu, H., Cheng, Y., & Ji, A. (2025) · Fusion Engineering and Design · doi:10.1016/j.fusengdes.2025.114803 · Cited by 3
Abdelwahab, S. İ., Taha, M. M. E., Farasani, A. M., Moshi, J. M., Alshahrani, A. F., Assiri, A., Alshahrani, S., Sultan, M. H., Sahli, K. A., Shubaily, H. M., et al. (2025) · Journal of Robotic Surgery · doi:10.1007/s11701-025-02542-8 · Cited by 3
Adaptative damping assistance in bimanual laparoscopic surgery
Nassar, A., Vérité, F., Pechereau, F., Morel, G., & Vitrani, M. (2022) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-022-02796-9 · Cited by 4
Force Feedback Augmentation Method for the Minimally Invasive Surgical System
Pitakwatchara, P., Warisawa, S., & Mitsuishi, M. (2006) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2006.282042 · Cited by 3
Vision Aided Active Error Canceling in Handheld Microsurgical Instrument
Aye, Y. N., Zhao, S., Shee, C. Y., & Ang, W. T. (2012) · Procedia Engineering · doi:10.1016/j.proeng.2012.07.236 · Cited by 3
Chung, G. B., Chung, J. H., Choi, D. G., Yi, B. J., Han, S. Y., & Kim, S. J. (2006) · Key engineering materials · doi:10.4028/www.scientific.net/kem.326-328.773 · Cited by 3
Azimian, H. (2015) · Elsevier eBooks · doi:10.1016/b978-0-08-100123-3.00005-1 · Cited by 4
SpinoTemplate: A Platform for MRI-Guided Spinal Cord Injections
Squires, A., Oshinski, J. N., Lamanna, J. J., & Tse, Z. T. H. (2016) · Journal of Medical Robotics Research · doi:10.1142/s2424905x16400067 · Cited by 3
Retinal surgery with flexible robots: Biomechanical advantages
Bergeles, C., Sugathapala, M. H., & Yang, G. (2018) · International Symposium on Medical Robotics · doi:10.1109/ismr.2018.8333242 · Cited by 4
A Partial Compliant Mechanism for Precise Remote-Center Motion
Islam, T. U., & Gandhi, P. S. (2018) · Lecture notes in mechanical engineering · doi:10.1007/978-981-10-8597-0_60 · Cited by 3
Design of an IoT based warfare car robot using sensor network connectivity
Imran, L. B., Farhan, M., Latif, R. M. A., & Rafiq, A. (2018) · International Conference on Future Networks and Distributed Systems (ICFNDS) · doi:10.1145/3231053.3231121 · Cited by 5
Arata, J., Kobayashi, Y., Nakadate, R., Onogi, S., Kiguchi, K., & Hashizume, M. (2018) · Journal of Robotics and Mechatronics · doi:10.20965/jrm.2018.p0846 · Cited by 4
FBG-based Kalman Filtering and Control of Tool Insertion Depth For Safe Robot-assisted Vitrectomy
Ebrahimi, A., Urias, M. G., Patel, N. A., Gehlbach, P. L., Alambeigi, F., & Iordachita, I. I. (2020) · International Symposium on Medical Robotics · doi:10.1109/ismr48331.2020.9312931 · Cited by 3
Menciassi, A., & Laschi, C. (2013) · IGI Global eBooks · doi:10.4018/978-1-4666-4607-0.ch079 · Cited by 4
Measuring the Quality of Learning in a Human–Robot Collaboration: A Study of Laparoscopic Surgery
Ferrier-Barbut, É., Gauthier, P., Luengo, V., Canlorbe, G., & Vitrani, M. (2022) · ACM Transactions on Human-Robot Interaction · doi:10.1145/3476414 · Cited by 3
“Comanipulation can be applied to tasks that require both precise manipulation and human judgment so as to enhance gesture quality [37].”
Development of SCARA-Type Haptic Device for Electrostatic Non-Contact Handling System
van West, E., Yamamoto, A., Burns, B., & Higuchi, T. (2008) · Journal of Advanced Mechanical Design Systems and Manufacturing · doi:10.1299/jamdsm.2.180 · Cited by 3
Telemanipulatorunterstützte endoskopische Herzchirurgie
Jacobs, S., Falk, Holzhey, D. M., & Mohr, F. (2002) · Journal für Kardiologie (Krause & Pachernegg GmbH) · Cited by 3
Towards requirements engineering for a tumour removing robot
Masih, A. (2011) · ACM Conference on Computer Supported Cooperative Work (CSCW) · doi:10.1145/1958824.1958943 · Cited by 2
A Novel Semi-Autonomous Control Framework for Retina Confocal Endomicroscopy Scanning
Li, Z., Shahbazi, M., Patel, N. A., Sullivan, E. O., Zhang, H., Vyas, K., Chalasani, P., Gehlbach, P. L., Iordachita, I. I., Yang, G., et al. (2019) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros40897.2019.8967751 · Cited by 2
Self-citationA fully passive fluidic cup holder for tremor compensation
Fischer, M., Irlinger, F., & Lueth, T. C. (2010) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2010.5627818 · Cited by 2
van West, E., Yamamoto, A., & Higuchi, T. (2011) · Mechatronics · doi:10.1016/j.mechatronics.2011.08.001 · Cited by 2
Wakamatsu, H., Watanabe, T., Satô, Y., Takase, S., Omata, S., & Yokoyama, H. (2010) · Innovations Technology and Techniques in Cardiothoracic and Vascular Surgery · doi:10.1097/imi.0b013e3181f6536b · Cited by 2
Yen, P., Chu, Y., Hsu, S., Wang, J., & Hung, S. (2013) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.1526 · Cited by 2
On servo experiment of a new multi-DOF robotic forceps manipulator for minimally invasive surgery
Ishii, C., & Kamei, Y. (2008) · International Symposium on Mechatronics and its Applications · doi:10.1109/isma.2008.4648813 · Cited by 2
Pitakwatchara, P., Warisawa, S., & Mitsuishi, M. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259933 · Cited by 2
Teleoperated MRI-guided prostate needle placement
Seifabadi, R. (2013) · Cited by 2
A design methodology and development of a mobile telepresence robot for paraplegics
Marafa, N. A., Filho, W. D. B. V., & Llanos, C. H. (2020) · Product Management & Development · doi:10.4322/pmd.2020.030 · Cited by 2
Karas, & Baig (2008) · doi:10.5772/5247 · Cited by 2
Registration and motion compensation of a needle placement robot for CT-guided spinal procedures
Xu, S. Y., Cleary, K., Stoianovici, D. S., & Gabor Fichtinger, A. (2005) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.594731 · Cited by 2
Self-citationPitakwatchara, P., Warisawa, S., & Mitsuishi, M. (2008) · Springer eBooks · doi:10.1007/978-3-540-77457-0_13 · Cited by 2
Robotic Comanipulation With Active Impedance Control
Cortesão, R., Zenowich, B., ́jo, R. A., & Townsend, W. T. (2009) · ASME World Conference on Innovative Virtual Reality (WINVR) · doi:10.1115/winvr2009-724 · Cited by 2
Design and implementation of a two degree-of-freedom micromanipulation assessment system
Latt, W. T., Ananda, E. S., Ong, S. C. L., Veluvolu, K. C., Shee, C. Y., & Ang, W. T. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650493 · Cited by 3
Augmented manual fabrication methods for 2d tool positioning and 3d sculpting
Durand, F., & Rivers, A. R. (2013) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 2
Sood, S. P. (2006) · Wiley eBooks · doi:10.1002/9780471740360.ebs1438 · Cited by 4
Precision medicine in ophthalmology
Roizenblatt, M., Roizenblatt, J., Jiramongkolchai, K., Gehlbach, P. L., Brant, R., Maia, M., & Belfort, R. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-819178-1.00035-6 · Cited by 1
Wang, Y., Zheng, H., Lee, Y.-C., Chan, C. P. L., Chan, J. Y. K., Taylor, R. H., & Au, K. W. S. (2023) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros55552.2023.10342097 · Cited by 1
Self-citationRobotics in Microneurosurgery: Beyond the Exoscope
Takuma, M., & Nisson, P. L. (2024) · World Neurosurgery · doi:10.1016/j.wneu.2024.08.012 · Cited by 1
Enhancements to the Planar Active Handrest
Fehlberg, M. A., Sani, H. N., & Provancher, W. R. (2015) · Journal of Human-Robot Interaction · doi:10.5898/jhri.4.3.fehlberg · Cited by 1
Williamson, T., Caversaccio, M. D., Weber, S., & Bell, B. J. (2015) · CRC Press eBooks · doi:10.1201/b19147-10 · Cited by 1
Medical Manipulators for Surgical Applications
Duan, X., Wang, X., & Huang, Q. (2013) · IGI Global eBooks · doi:10.4018/978-1-4666-4607-0.ch030 · Cited by 1
Medical robotics and fluoroscopy servoing: automating needle placement for spine procedures
Corral, G., Ibáñez, L. V. M., Nguyen, C. C., Stoianovici, D. S., Navab, N., & Cleary, K. (2004) · World Automation Congress (WAC) · Cited by 1
Self-citationRail transit assembly robot systems
Liu, H. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-822968-2.00002-4 · Cited by 1
Robotics in Vitreoretinal Surgeries
Gerber, M. J., & Hubschman, J. (2021) · Springer eBooks · doi:10.1007/978-981-33-4168-5_10 · Cited by 1
Medical Manipulators for Surgical Applications
Duan, X., Wang, X., & Huang, Q. (2012) · Advances in bioinformatics and biomedical engineering book series · doi:10.4018/978-1-4666-2196-1.ch012 · Cited by 1
Menciassi, A., & Laschi, C. (2013) · IGI Global eBooks · doi:10.4018/978-1-4666-0122-2.ch011 · Cited by 1
Tabrizi, P. R., Monfaredi, R., Liu, W. P., Taylor, R. H., Cleary, K., & Preciado, D. A. (2017) · Springer eBooks · doi:10.1007/978-3-319-49578-1_17 · Cited by 1
Self-citationWilliamson, T., Caversaccio, M. D., Weber, S., & Bell, B. J. (2015) · CRC Press eBooks · doi:10.1201/b19147-6 · Cited by 1
Kumar, R. (2010) · The electrical engineering handbook/Electrical engineering handbook series/Electrical engineering handbook · doi:10.1201/b10382-25 · Cited by 1
Self-citationAssessment and Elimination of Surgeon Hand Tremor During Robotic Surgery
Kumar, A., Kumar, S., & Kumar, A. (2022) · Springer eBooks · doi:10.1007/978-981-19-1550-5_97-1 · Cited by 4
Robotic Systems in Ophthalmologic Surgery
Roizenblatt, M., Ebrahini, A., Iordachita, I. I., & Gehlbach, P. L. (2023) · Springer eBooks · doi:10.1007/978-3-031-35102-0_12 · Cited by 1
Lens Capsule Tearing in Cataract Surgery using Reinforcement Learning
Peter, R. C., Peikert, S., Haide, L., Pham, D. X. V., Chettaoui, T., Tagliabue, E., Scheikl, P. M., Fauser, J., Hillenbrand, M., Neumann, G. M., et al. (2024) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra57147.2024.10611714 · Cited by 3
“Teleoperating systems can help reduce the surgeons hand tremor due to motion scaling [8], [10], [11], [12], [13].”
Retracted: Human-Machine Collaborative Systems for Microsurgical Applications
Kragić, D., Marayong, P., Li, M., Okamura, A. M., & Hager, G. D. (2005) · Springer tracts in advanced robotics · doi:10.1007/11008941_18 · Cited by 1
RetractedMohammad, T. (2014) · Journal of Applied Biomedicine · doi:10.1016/j.bbe.2014.10.003 · Cited by 1
A class of 1 DOF planar RCM mechanism based on motion-reproduce method
Chen, Z., Li, J., Zhang, G., & Wang, S. (2015) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2015.7418972 · Cited by 1
Mattos, L. S., Pardo, D., Olivieri, E., Barresi, G., Ortiz, J., Fichera, L., Deshpande, N., & Penza, V. (2015) · CRC Press eBooks · doi:10.1201/b19147-5 · Cited by 1
Robotics in Stereotactic Neurosurgery
Stricsek, G. P., Khanna, O., & Wu, C. (2018) · Elsevier eBooks · doi:10.1016/b978-0-323-48569-2.00027-6 · Cited by 1
Askaripoor, H., Zhou, M., Lohmann, C. P., Cerveri, P., & Nasseri, M. A. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857360 · Cited by 2
Design and Kinematics Analysis of a Percutaneous Needle Insertion Robotic System
Zhou, Z., Zhang, X., Gao, Y., Wu, D., & Dong, W. (2020) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/825/1/012009 · Cited by 1
Azar, A. T., & Eljamel, S. (2013) · IGI Global eBooks · doi:10.4018/978-1-4666-4607-0.ch054 · Cited by 2
Quantification of operability for surgical robot using f-NIRS
Miura, S., Kobayashi, Y., Kawamura, K., Seki, M., Nakashima, Y., Noguchi, T., Yokoo, Y., & Fujie, M. G. (2014) · Journal of Japan Society of Computer Aided Surgery · doi:10.5759/jscas.16.61 · Cited by 1
Revisiting the Effect of Velocity on Human Force Control
Nambi, M., Provancher, W. R., & Abbott, J. J. (2010) · Lecture notes in computer science · doi:10.1007/978-3-642-14064-8_22 · Cited by 1
Fuzzy Calibration of Magnetometer in Presence of Surgical Microscope
Benjavitvilai, C., & Riviere, C. N. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1615610 · Cited by 1
Lemma, M. G., Mangini, A., Redaelli, A. C. L., & Acocella, F. (2005) · Cited by 1
Lorenz, C. H., & Dewan, M. A. A. (2008) · Cited by 1
Haptic Feedback Enhancement Through Adaptive Force Scaling: Theory and Experiment
Roy, J., Rothbaum, D. L., & Whitcomb, L. L. (2007) · Springer eBooks · doi:10.1007/978-3-540-37347-6_14 · Cited by 1
“In tele-robotic force reflection, the the objective is to provide force feedback during remote manipulation at sites distant from the human operator [16, 13, 14, 17].”
InfluentialSelf-citationUngrounded haptic-feedback for hand-held surgical robots
Payne, C. J. (2015) · Spiral (Imperial College London) · doi:10.25560/26587 · Cited by 4
Adaptive and reconfigurable robotic gripper hands with a meso-scale gripping range
Bai, G. (2018) · Cited by 1
Control, Sensing, and Telemanipulation of Surgical Continuum Robots
Bajo, A. (2013) · Cited by 1
Cleary, K., & Nguyen, C. C. (2013) · Handbook series for mechanical engineering/Mechanical engineering handbook series · doi:10.1201/b15085-39 · Cited by 1
Robotics in Cardiac Surgery: Basic Principles
Falk, V., & Stein, H. (2014) · Springer eBooks · doi:10.1007/978-1-4471-6332-9_1
Using Haptic Technology to Improve Non-Contact Handling: the “Haptic Tweezer” Concept
van, E., Yamamoto, A., & Higuchi, T. (2010) · InTech eBooks · doi:10.5772/8692
Aktueller Stand der Roboterchirurgie — Ausblick auf zukünftige Optionen
Börner, M., & Ditzen, W. (2003) · Springer eBooks · doi:10.1007/978-3-642-55784-2_55
Novel Real-Time Tremor Transduction Technique for Microsurgery
Tomlin, D. H., Wallace, J. W., Etienne‐Cummings, R., & Thakor, N. V. (2001) · Lecture notes in computer science · doi:10.1007/3-540-45468-3_45
Falk, V., Walther, T., & Mohr, F. W. (2004) · doi:10.1007/978-1-59259-416-0_31
Injection-depth-locking axial motion guided handheld micro-injector using CP-SSOCT
Cheon, G. W., Huang, Y., Kwag, H. R., Kim, K., Taylor, R. H., Gehlbach, P. L., & Kang, J. U. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6945036
“There have been several researches to address such motion problems actively [2-5].”
Self-citationA Design of an Intelligent Auto Sampler
Li, W. T., Yu, X., Liu, X. J., Yang, Y. Y., & Xiao, G. F. (2012) · Advanced materials research · doi:10.4028/www.scientific.net/amr.462.295
Determine the robot assistive forces based on human intent estimation in bone cutting applications
Hsu, S., & Yen, P. (2013) · International Conference on Control, Automation and Systems (ICCAS) · doi:10.1109/iccas.2013.6704053
A Robot Arm for Assisting Liver Surgery
Xie, X., Na, Q., Zhao, C., & Du, R. (2011) · Computer-Aided Design and Applications · doi:10.3722/cadaps.2011.713-722
The effects of constraint curvature on projective and set stabilization controllers
Walker, K. C., Nielsen, C., & Wang, D. W. L. (2012) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2012.6385550
Masamune, K., Gabor Fichtinger, A., Patriciu, A., Susil, R. C., Taylor, R. H., Kavoussi, L. R., Anderson, J. H., Sakuma, I., Dohi, T., & Stoianovici, D. S. (2002)
Self-citationJacobs, S., & Falk, V. (2011) · Elsevier eBooks · doi:10.1016/b978-3-437-24880-1.10033-9
A Novel Robotic Assistant for Reducing Hand-Held Surgical Tool Tremor in Surgical Navigation
Zhang, W., & Pan, Y. (2009) · International Conference on Bioinformatics and Biomedical Engineering · doi:10.1109/icbbe.2009.5162225
TREMOR MEASUREMENT AND SUPPRESSION TECHNIQUE FOR MICROSURGERIES
Kamble, H. C., Kulkarni, E., & Bakatwar, R. (2014)
Mukherjee, U. K. (2015) · University of Minnesota Digital Conservancy (University of Minnesota)
Tan, U.-X. (2010) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/40882
Optical Coherence Tomography Guided Smart Microsurgical Tools
Kang, J. U. (2014) · Biomedical optics · doi:10.1364/biomed.2014.bw3a.4
Status Quo and Options in Medical Robotics
Börner, M., & Ditzen, W. (2004) · Springer eBooks · doi:10.1007/978-3-642-59290-4_73
Reliability enhancements of surgical robots through software fault tolerance
Prajapati, J. B., & Modi, N. (2015)
Frumento, S., Razzoli, R. P., & Cepolina, F. E. (2013) · IGI Global eBooks · doi:10.4018/978-1-4666-3990-4.ch011
Improving large workspace precision manipulation through use of an active handrest
Fehlberg, M. A. (2014) · ProQuest Demo Repository · doi:10.26053/0h-c3wp-zng0
Shared control for natural motion and safety in hands-on robotic surgery
Petersen, J. G. (2015) · doi:10.25560/45398
Cruz, V. C. V. D. S. C., & Radermacher, K. (2013)
Metadata
- Authors
- Taylor, R., Jensen, P., Whitcomb, L., Barnes, A., Kumar, R., Stoianovici, D., Gupta, P., Wang, Z., Dejuan, E., & Kavoussi, L.
- Affiliations
- Johns Hopkins University (US)
- Wilmer Eye Institute, Johns Hopkins Medical Institutions, Johns Hopkins University, Baltimore, MD, USA
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 1999-12
- Volume
- 18
- Issue
- 12
- Pages
- 1201-1210
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2149985621
- Cited by
- 528
- References
- 43
- Citations by year
- 2026: 8 · 2025: 13 · 2024: 7 · 2023: 15 · 2022: 15 · 2021: 19 · 2020: 29 · 2019: 26 · 2018: 25 · 2017: 13 · 2016: 15 · 2015: 30 · 2014: 21 · 2013: 30 · 2012: 29
- FWCI
- 26.82
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- The International Journal of Robotics Research (publishedVersion)
- Funders
- National Science Foundation
- Johns Hopkins University
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Robot Manipulation and Learning
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Keywords
- microsurgery, force scaling, force sensing, human-robot interaction, tremor suppression, compliant manipulation, eye-hand coordination
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.