The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
A Steady-Hand Robotic System for Microsurgical Augmentation
Abstract
This paper reports the development of a robotic system designed to extend a human’s ability to perform small-scale (sub-millimeter) manipulation tasks requiring human judgment, sensory integration, and hand-eye coordination. Our novel approach, which we call steady-hand micromanipulation, is for tools to be held simultaneously both by the operator’s hand and a specially designed actively controlled robot arm. The robot’s controller senses forces exerted by the operator on the tool and by the tool on the environment, and uses this information in various control modes to provide smooth, tremor-free, precise positional control and force scaling. Our goal is to develop a manipulation system with the precision and sensitivity of a machine, but with the manipulative transparency and immediacy of hand-held tools for tasks characterized by compliant or semi-rigid contacts with the environment.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the 'steady-hand' approach of Taylor et al. [6], in which a robotic arm and the surgeon's hand hold the same instrument simultaneously, the robot sensing the force applied by the human hand and selectively complying in order to suppress unwanted components while allowing the desired movement.”
From Toward active tremor canceling in handheld microsurgical instruments (2003) · cites this paper as [6]
Citations
Cites
A telerobotic assistant for laparoscopic surgery
Taylor, R. H., Funda, J., Eldridge, B., Gomory, S., Gruben, K., LaRose, D., Talamini, M., Kavoussi, L., & Anderson, J. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.391776 · Cited by 392
Self-citationAn image-directed robotic system for precise orthopaedic surgery
Taylor, R. H., Mittelstadt, B. D., Paul, H. A., Hanson, W., Kazanzides, P., Zuhars, J. F., Williamson, B., Musits, B. L., Glassman, E., & Bargar, W. L. (1994) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.294202 · Cited by 347
Self-citationEj, L. (1997) · PubMed · Cited by 326
Space Robotics: Dynamics and Control
(1993) · The Kluwer International Series in Engineering and Computer Science · doi:10.1007/978-1-4615-3588-1 · Cited by 263 · cited 1×
“[17-19]); and 3) master-slave teleoperators (e.g., [ 20-22 ]).”
Tactile Display of Vibratory Information in Teleoperation and Virtual Environments
Kontarinis, D. A., & Howe, R. D. (1995) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.1995.4.4.387 · Cited by 251 · cited 1×
“We have begun preliminary experiments with vibrotactile displays (Kontarinis and Howe 1995).”
Teleoperation, telerobotics and telepresence: A progress report
Sheridan, T. B. (1995) · Control Engineering Practice · doi:10.1016/0967-0661(94)00078-u · Cited by 243
Comparative experiments with a new adaptive controller for robot arms
Whitcomb, L. L., Rizzi, A. A., & Koditschek, D. E. (1993) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.210795 · Cited by 236
Self-citationA modular surgical robotic system for image guided percutaneous procedures
Stoianovici, D., Whitcomb, L. L., Anderson, J. H., Taylor, R. H., & Kavoussi, L. R. (1998) · Lecture Notes in Computer Science · doi:10.1007/bfb0056225 · Cited by 174 · cited 1×
“We have applied the RCM in conjunction with the PAKY needle driver for performing image guided renal access [45, 46].”
Self-citationKazerooni, H., & Guo, J. (1993) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.2899068 · Cited by 119
Modeling and canceling tremor in human-machine interfaces
Riviere, C. N., & Thakor, N. V. (1996) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.499755 · Cited by 114 · cited 2×
“Our immediate goal is a rigorous evaluation of the completed system as a microsurgery augmentation aid, using test environments developed by our colleagues at JHU’s Wilmer Eye Institute and CMU (Humayun et al. 1997; Riviere and Thakor 1996; Riviere and Khosla 1999a, 1999b).”
Ho, S. C., Hibberd, R. D., & Davies, B. L. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.391774 · Cited by 101 · cited 2×
“Davies and colleagues (Harris et al. 1997; Ho, Hibberd, and Davies 1995; Troccaz, Peshkin, and Davies 1997) have combined hands-on guiding with position limits and have demonstrated 3-DoF machining of shapes in the end of a human tibia.”
Performance measurement in scaled teleoperation for microsurgery
Salcudean, S. E., Ku, S., & Bell, G. (1997) · Lecture Notes in Computer Science · doi:10.1007/bfb0029304 · Cited by 96 · cited 4×
“Many microsurgical devices (Hunter et al. 1995; Charles 1994; Misuishi et al. 1997; Salcudean, Ku, and Bell 1997; Schenker, Das, and Timothy 1995) are based on forcereflecting master-slave configurations.”
InfluentialToward robot-assisted vascular microsurgery in the retina
Jensen, P. S., Grace, K. W., Attariwala, R., Colgate, J. E., & Glucksberg, M. R. (1997) · Graefe's Archive for Clinical and Experimental Ophthalmology · doi:10.1007/bf01880668 · Cited by 90
Self-citationSMOS: stereotaxical microtelemanipulator for ocular surgery
Guerrouad, A., & Vidal, P. (2003) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1989.96028 · Cited by 78 · cited 2×
“Guerrouad and Vidal (1989) described a system designed for ocular vitrectomy in which a mechanical manipulator was constructed of curved tracks to maintain a fixed center of rotation.”
Fusion of human and machine intelligence for telerobotic systems
Guo, C., Tarn, T., Xi, N., & Bejczy, A. K. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1995.525727 · Cited by 73 · cited 3×
“The work most relevant to this includes that of Kazarooni (Kazerooni 1989a, 1989b; Kazerooni and Jenhwa 1993), who developed exoskeletons to amplify the strength of a human operator.”
Quantitative Measurement of the Effects of Caffeine and Propranolol on Surgeon Hand Tremor
Humayun, M. U. (1997) · Archives of Ophthalmology · doi:10.1001/archopht.1997.01100150373010 · Cited by 71
An efficient needle injection technique and radiological guidance method for percutaneous procedures
Stoianovici, D. S., Cadeddu, J. A., Demaree, R. D., Basile, S. A., Taylor, R. H., Whitcomb, L. L., Sharpe, W. N., & Kavoussi, L. R. (1997) · Lecture notes in computer science · doi:10.1007/bfb0029248 · Cited by 70
Self-citationOphthalmic microsurgical robot and associated virtual environment
Hunter, I. W., Jones, L. A., Sagar, M. A., Lafontaine, S. R., & Hunter, P. J. (1995) · Computers in Biology and Medicine · doi:10.1016/0010-4825(94)00042-o · Cited by 70
Adaptive model-based hybrid control of geometrically constrained robot arms
Whitcomb, L. L., Arimoto, S., Naniwa, T., & Ozaki, F. (1997) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.554351 · Cited by 68 · cited 1×
“Standard paradigms include 1) pre-programmed trajectory control of position [13, 14] and force [15, 16]; 2) fully autonomous robots (e.”
Self-citationOutflow facility studies in the perfused human ocular anterior segment
Erickson-Lamy, K. A., Rohen, J. W., & Grant, W. M. (1991) · Experimental Eye Research · doi:10.1016/0014-4835(91)90024-9 · Cited by 67
Kazerooni, H. (2003) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1989.100211 · Cited by 63 · cited 5×
“Kazarooni and colleagues (Kazerooni 1989a, 1989b; Kazerooni and Jenhwa 1993) reported a linear-systems analysis of the stability and robustness of cooperative human-robot manipulator-control systems in which the manipulator scales up the human operator’s force input by a factor of∼ 10.”
InfluentialThe use of localizers, robots and synergistic devices in CAS
Troccaz, J., Peshkin, M. A., & Davies, B. (1997) · Lecture notes in computer science · doi:10.1007/bfb0029298 · Cited by 53 · cited 2×
“[39-41], have combined hands-on guiding with position limits and have demonstrated 3 DOF machining of shapes in the end of a human tibia.”
Coordinated task execution of a human and a mobile manipulator
Yamamoto, Y., Eda, H., & Yun, X. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1996.506840 · Cited by 44 · cited 2×
“There has also been some work (e.g., [ 27 ]) on control of robots working cooperatively with humans to carry loads and do other gross motor tasks relevant for construction and similar applications.”
A remote center of motion robotic arm for computer assisted surgery
Eldridge, B. N., Gruben, K. G., LaRose, D., Funda, J., Gomory, S., Karidis, J. P., McVicker, G., Taylor, R. H., & Anderson, J. (1996) · Robotica · doi:10.1017/s0263574700018981 · Cited by 40 · cited 2×
“, in the “Robodoc” [28-30] hip replacement surgery system and in the JHU/IBM LARS system [31-38] for endoscopic surgery).”
Self-citationCadeddu, J. A., Stoianovici, D. S., & Kavoussi, L. R. (1997) · Urology · doi:10.1016/s0090-4295(96)00561-4 · Cited by 38 · cited 1×
“The robot has been successfully used at the Johns Hopkins Medical Institutions for nine surgical procedures [ 45 ].”
Self-citationAugmenting the human-machine interface: improving manual accuracy
Riviere, C. N., & Khosla, P. K. (2002) · Proceedings of International Conference on Robotics and Automation · doi:10.1109/robot.1997.606884 · Cited by 36 · cited 2×
“We will compare the system in-vitro and in cadaveric models both against unassisted humans and against alternative methods for reducing physiological tremor (e.g., [52, 55 ]).”
Experiences with robotic systems for knee surgery
Harris, S. J., Lin, W., Fan, K., Hibberd, R. D., Cobb, J. P., Middleton, R., & Davies, B. L. (1997) · Lecture notes in computer science · doi:10.1007/bfb0029301 · Cited by 35 · cited 1×
“[39-41], have combined hands-on guiding with position limits and have demonstrated 3 DOF machining of shapes in the end of a human tibia.”
Performance of Robotic Augmentation in Microsurgery-Scale Motions
Kumar, R., Goradia, T. M., Barnes, A. C., Jensen, P. S., Whitcomb, L. L., Stoianovici, D. S., Auer, L. M., & Taylor, R. H. (1999) · Lecture notes in computer science · doi:10.1007/10704282_120 · Cited by 33 · cited 1×
“unassisted to 78% for 250 μm holes [49].”
Self-citationPournaras, C. J., Shonat, R. D., Munoz, J.-L., & Petrig, B. L. (1991) · Experimental Eye Research · doi:10.1016/0014-4835(91)90107-p · Cited by 29 · cited 1×
“As CIS systems evolve, two related paradigms will emerge.”
Experiments with a steady hand robot in constrained compliant motion and path following
Kumar, R., Jensen, P., & Taylor, R. H. (2003) · IEEE RO-MAN · doi:10.1109/roman.1999.900321 · Cited by 28 · cited 3×
“In other work (Kumar, Jensen, and Taylor 1999), we have begun exploring the use of simple visual feedback strategies to assist humans in tracking linear features.”
InfluentialSelf-citationMitsuishi, M., Watanabe, H., Nakanishi, H., Kubota, H., & Iizuka, Y. (1997) · Lecture notes in computer science · doi:10.1007/bfb0029309 · Cited by 26
Optimal motion control for teleoperated surgical robots
Funda, J., Taylor, R. H., Gruben, K. G., & LaRose, D. (1993) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.164902 · Cited by 23 · cited 1×
“, in the “Robodoc” [28-30] hip replacement surgery system and in the JHU/IBM LARS system [31-38] for endoscopic surgery).”
Self-citationRobot-assisted minimally invasive neurosurgical procedures: First experimental experience
Goradia, T. M., Taylor, R. H., & Auer, L. M. (1997) · Lecture notes in computer science · doi:10.1007/bfb0029252 · Cited by 22
Self-citationVisual control of autonomous mobile robot based on self‐organizing model for pattern learning
Suzuki, H., & Arimoto, S. (1988) · Journal of Robotic Systems · doi:10.1002/rob.4620050505 · Cited by 21 · cited 2×
“[17-19]); and 3) masterslave teleoperators (e.”
Performance of a six-legged planetary rover: power, positioning, and autonomous walking
Krotkov, E., & Simmons, R. G. (2003) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1992.220267 · Cited by 20 · cited 2×
“…Sakakibara 1996) and force (Whitcomb, Rizzi, and Koditschek 1993; Whitcomb et al. 1997); 2) fully autonomous robots (e.g., Suzuki and Arimoto 1988; Krotkov and Simmons 1992; Yoerger, Bradley, and Walden 1992); and 3) master-slave teleoperators (e.g., Xu and Kanade 1993; Morikawa and Takanashi…”
Intraoperative tremor monitoring for vitreoretinal microsurgery.
Gomez-Blanco, M., Riviere, C. N., & Khosla, P. K. (2000) · PubMed · Cited by 19
HUANG, S. F., Patel, H., & Bellman, G. C. (1998) · Journal of Endourology · doi:10.1089/end.1998.12.237 · Cited by 15
Comparison of two manipulator designs for laparoscopic surgery
Funda, J., Eldridge, B. N., Gruben, K. G., Gomory, S., & Taylor, R. H. (1995) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.197308 · Cited by 13
Self-citationMicroscale Tracking of Surgical Instrument Motion
Riviere, C. N., & Khosla, P. K. (1999) · Lecture notes in computer science · doi:10.1007/10704282_117 · Cited by 12 · cited 1×
“Our immediate goal is a rigorous evaluation of the completed system as a microsurgery augmentation aid, using test environments developed by our colleagues at JHU’s Wilmer Eye Institute and CMU (Humayun et al. 1997; Riviere and Thakor 1996; Riviere and Khosla 1999a, 1999b).”
Development of a new high-dexterity manipulator for robot-assisted microsurgery
Schenker, P. S., Das, H., & Ohm, T. R. (1995) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.197310 · Cited by 10 · cited 1×
“Mechanical systems have been developed which extend the capability of human operators using telerobotic principles (Sheridan 1995), including virtual training (Hunter et al. 1995), manipulation of objects in hazardous environments (Mindell et al. 1993), remote surgery (Satava 1992; Green et al.…”
Ground experiment system for space robots based on predictive bilateral control
Morikawa, H., & Takanashi, N. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1996.503574 · Cited by 6 · cited 2×
“[17-19]); and 3) master-slave teleoperators (e.g., [ 20-22 ]).”
A two-armed intelligent robot assembles mini robots automatically
Sakakibara, S. (2002) · Proceedings of the Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.1996.570760 · Cited by 5 · cited 2×
“Standard paradigms include 1) preprogrammed trajectory control of position (Dinsmoor and Hagermann 1993; Sakakibara 1996) and force (Whitcomb, Rizzi, and Koditschek 1993; Whitcomb et al. 1997); 2) fully autonomous robots (e.g., Suzuki and Arimoto 1988; Krotkov and Simmons 1992; Yoerger, Bradley,…”
In-vivo microscopy using gradient index of refraction (GRIN) lens endoscopy
Jensen, P. S., & de Juan, E. (1999) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.350574 · Cited by 5 · cited 1×
“, [54], optical coherence tomography, etc.”
Self-citation
Research works printed but not linked: 10
- Bargar, W., etal. 1995 (Baltimore, MD). Robodoc Multicenter trial: An interim report . Proc. of the 2nd Intl. Symp. on Medical Robot. and Comp.Assisted Surgery, MRCAS ’95. Pittsburgh, PA: C/O Center for Orthop. Res., Shadyside Hospital.
- Charles, S. 1994. Dexterity enhancement for surgery . Proc. of the First Intl. Symp. on Medical Robot. and Comp.Assisted Surgery, vol. 2, pp. 145–160 .
- Cho, Y., Kotoku, T., and Tanie, K. 1995 (Pittsburgh, PA). Discrete-event-planning and control of telerobotic part mating process with communication delay in geometric uncertainty . Proc. of the IEEE Conf. on Intell. Robot. and Sys. Washington, DC: IEEE Press.
- Dinsmoor, C., and Hagermann, P. 1993 (Detroit, MI). Fanuc robotics system r-j controller . Proc. of the Intl. Robots and Vision Automat. Conf.
- Funda, J., et al. 1994. Image-guided command and control of a surgical robot . Proc. Med. Meets Virtual Reality II. San Diego, CA.
- Kazerooni, H. 1989b. Human/robot interaction via the transfer of power and information signals—part II: Dynamics and control analysis. Proc. of the IEEE Conf. on Robot. and Automat. Los Alamitos, CA: IEEE .
- Kumar, R., et al. 1997 (Tokyo, Japan). Robot-assisted microneurosurgical procedures, comparative dexterity experiments . Proc. of the Society for Minimally Invasive Therapy, 9th Annual Meeting, abstract book vol. 6, suppl. 1.
- Mindell, D. A., et al. 1993. JasonTalk: A standard ROV vehicle control system. Proc. of IEEE/MTS OCEANS’93. Los Alamitos, CA: IEEE .
- Mittelstadt, B. D., et al. 1994. The evolution of a surgical robot from prototype to human clinical trial . Proc. of the Intl. Symp. on Medical Robot. and Comp.Assisted Surgery. Pittsburgh, PA.
- Stoianovici, D., et al. 1998. A modular surgical robotic system for image-guided percutaneous procedures. Medical Image Computing and Comp.Assisted Interventions (MICCAI-98). 1998. Cambridge, MA: Springer . · DOI · Paper page
Cited by
Medical robotics in computer-integrated surgery
Taylor, R. H., & Stoianovici, D. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817058 · Cited by 997
Self-citationMinimally Invasive and Robotic Surgery
Mack, M. J. (2001) · JAMA · doi:10.1001/jama.285.5.568 · Cited by 545
Medical Robotics and Computer-Integrated Surgery
Taylor, R. H., Menciassi, A., Fichtinger, G., Fiorini, P., & Dario, P. (2016) · Springer Handbooks · doi:10.1007/978-3-319-32552-1_63 · Cited by 325
Self-citationNew steady-hand Eye Robot with micro-force sensing for vitreoretinal surgery
Uneri, A., Balicki, M. A., Handa, J., Gehlbach, P., Taylor, R. H., & Iordachita, I. (2010) · 2010 3rd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics · doi:10.1109/biorob.2010.5625991 · Cited by 291
Self-citationBone-mounted miniature robot for surgical procedures: concept and clinical applications
Shoham, M., Burman, M., Zehavi, E., Joskowicz, L., Batkilin, E., & Kunicher, Y. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817075 · Cited by 292
Metadata
- Authors
- Taylor, R., Jensen, P., Whitcomb, L., Barnes, A., Kumar, R., Stoianovici, D., Gupta, P., Wang, Z., Dejuan, E., & Kavoussi, L.
- Affiliations
- Johns Hopkins University (US)
- Wilmer Eye Institute, Johns Hopkins Medical Institutions, Johns Hopkins University, Baltimore, MD, USA
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 1999-12
- Volume
- 18
- Issue
- 12
- Pages
- 1201-1210
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2149985621
- Cited by
- 528
- References
- 43
- Citations by year
- 2026: 8 · 2025: 13 · 2024: 7 · 2023: 15 · 2022: 15 · 2021: 19 · 2020: 29 · 2019: 26 · 2018: 25 · 2017: 13 · 2016: 15 · 2015: 30 · 2014: 21 · 2013: 30 · 2012: 29
- FWCI
- 26.82
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- The International Journal of Robotics Research (publishedVersion)
- Funders
- National Science Foundation
- Johns Hopkins University
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Robot Manipulation and Learning
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Keywords
- microsurgery, force scaling, force sensing, human-robot interaction, tremor suppression, compliant manipulation, eye-hand coordination
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.