A Steady-Hand Robotic System for Microsurgical Augmentation
The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
This paper reports the development of a robotic system designed to extend a human’s ability to perform small-scale (sub-millimeter) manipulation tasks requiring human judgment, sensory integration, and hand-eye coordination. Our novel approach, which we call steady-hand micromanipulation, is for tools to be held simultaneously both by the operator’s hand and a specially designed actively controlled robot arm. The robot’s controller senses forces exerted by the operator on the tool and by the tool on the environment, and uses this information in various control modes to provide smooth, tremor-free, precise positional control and force scaling. Our goal is to develop a manipulation system with the precision and sensitivity of a machine, but with the manipulative transparency and immediacy of hand-held tools for tasks characterized by compliant or semi-rigid contacts with the environment.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the 'steady-hand' approach of Taylor et al. [6], in which a robotic arm and the surgeon's hand hold the same instrument simultaneously, the robot sensing the force applied by the human hand and selectively complying in order to suppress unwanted components while allowing the desired movement.”
From Toward active tremor canceling in handheld microsurgical instruments (2003) · cites this paper as [6]
Citations
Cites
A telerobotic assistant for laparoscopic surgery
Taylor, R. H., Funda, J., Eldridge, B., Gomory, S., Gruben, K., LaRose, D., Talamini, M., Kavoussi, L., & Anderson, J. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.391776 · Cited by 392
Self-citationAn image-directed robotic system for precise orthopaedic surgery
Taylor, R. H., Mittelstadt, B. D., Paul, H. A., Hanson, W., Kazanzides, P., Zuhars, J. F., Williamson, B., Musits, B. L., Glassman, E., & Bargar, W. L. (1994) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.294202 · Cited by 347
Self-citationEj, L. (1997) · PubMed · Cited by 326
Space Robotics: Dynamics and Control
(1993) · The Kluwer International Series in Engineering and Computer Science · doi:10.1007/978-1-4615-3588-1 · Cited by 263 · cited 1×
“[17-19]); and 3) master-slave teleoperators (e.g., [ 20-22 ]).”
Tactile Display of Vibratory Information in Teleoperation and Virtual Environments
Kontarinis, D. A., & Howe, R. D. (1995) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.1995.4.4.387 · Cited by 251 · cited 1×
“We have begun preliminary experiments with vibrotactile displays (Kontarinis and Howe 1995).”
Teleoperation, telerobotics and telepresence: A progress report
Sheridan, T. B. (1995) · Control Engineering Practice · doi:10.1016/0967-0661(94)00078-u · Cited by 243
Comparative experiments with a new adaptive controller for robot arms
Whitcomb, L. L., Rizzi, A. A., & Koditschek, D. E. (1993) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.210795 · Cited by 236
Self-citationA modular surgical robotic system for image guided percutaneous procedures
Stoianovici, D., Whitcomb, L. L., Anderson, J. H., Taylor, R. H., & Kavoussi, L. R. (1998) · Lecture Notes in Computer Science · doi:10.1007/bfb0056225 · Cited by 174 · cited 1×
“We have applied the RCM in conjunction with the PAKY needle driver for performing image guided renal access [45, 46].”
Self-citationKazerooni, H., & Guo, J. (1993) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.2899068 · Cited by 119
Modeling and canceling tremor in human-machine interfaces
Riviere, C. N., & Thakor, N. V. (1996) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.499755 · Cited by 114 · cited 2×
“Our immediate goal is a rigorous evaluation of the completed system as a microsurgery augmentation aid, using test environments developed by our colleagues at JHU’s Wilmer Eye Institute and CMU (Humayun et al. 1997; Riviere and Thakor 1996; Riviere and Khosla 1999a, 1999b).”
Research works printed but not linked: 10
- Bargar, W., etal. 1995 (Baltimore, MD). Robodoc Multicenter trial: An interim report . Proc. of the 2nd Intl. Symp. on Medical Robot. and Comp.Assisted Surgery, MRCAS ’95. Pittsburgh, PA: C/O Center for Orthop. Res., Shadyside Hospital.
- Charles, S. 1994. Dexterity enhancement for surgery . Proc. of the First Intl. Symp. on Medical Robot. and Comp.Assisted Surgery, vol. 2, pp. 145–160 .
- Cho, Y., Kotoku, T., and Tanie, K. 1995 (Pittsburgh, PA). Discrete-event-planning and control of telerobotic part mating process with communication delay in geometric uncertainty . Proc. of the IEEE Conf. on Intell. Robot. and Sys. Washington, DC: IEEE Press.
- Dinsmoor, C., and Hagermann, P. 1993 (Detroit, MI). Fanuc robotics system r-j controller . Proc. of the Intl. Robots and Vision Automat. Conf.
- Funda, J., et al. 1994. Image-guided command and control of a surgical robot . Proc. Med. Meets Virtual Reality II. San Diego, CA.
- Kazerooni, H. 1989b. Human/robot interaction via the transfer of power and information signals—part II: Dynamics and control analysis. Proc. of the IEEE Conf. on Robot. and Automat. Los Alamitos, CA: IEEE .
- Kumar, R., et al. 1997 (Tokyo, Japan). Robot-assisted microneurosurgical procedures, comparative dexterity experiments . Proc. of the Society for Minimally Invasive Therapy, 9th Annual Meeting, abstract book vol. 6, suppl. 1.
- Mindell, D. A., et al. 1993. JasonTalk: A standard ROV vehicle control system. Proc. of IEEE/MTS OCEANS’93. Los Alamitos, CA: IEEE .
- Mittelstadt, B. D., et al. 1994. The evolution of a surgical robot from prototype to human clinical trial . Proc. of the Intl. Symp. on Medical Robot. and Comp.Assisted Surgery. Pittsburgh, PA.
- Stoianovici, D., et al. 1998. A modular surgical robotic system for image-guided percutaneous procedures. Medical Image Computing and Comp.Assisted Interventions (MICCAI-98). 1998. Cambridge, MA: Springer . · DOI · Paper page
Cited by
Items 501–528 of 528
An articulated drill and hybrid tracking navigation system for orthopaedic surgery
Fuad, A. N. B. A. (2019) · STAX · doi:10.48730/1pqj-jg41
Optimal Design and Dynamic Analysis of a Hybrid Manipulator for Intra-ocular Surgeries
Hayati, H., Taefi, M., Khosravi, M. A., & Talebi, H. A. (2019) · RSI International Conference on Robotics and Mechatronics (ICRoM) · doi:10.1109/icrom48714.2019.9071888
Lin, M. C., & Otaduy, M. Á. (2008) · A K Peters/CRC Press eBooks · doi:10.1201/b10636-31
Gauthier, M., Andreff, N., & Dombre, E. (2014) · Wiley eBooks · doi:10.1002/9781118579107.biblio
Nguyen, C. C., & Cleary, K. (2003) · Handbook series for mechanical engineering/Mechanical engineering handbook series · doi:10.1201/9780203491492.ch32
Yokoyama, H. (2015) · Springer eBooks · doi:10.1007/978-4-431-54986-4_10
Parient bed transfer analysis using pressure sensor arrays
Veledar, I. (2009) · Carleton University's Institutional Repository (MacOdrum Library, Carleton University) · doi:10.22215/etd/2009-08855
Frumento, S., Razzoli, R. P., & Cepolina, F. E. (2014) · IGI Global eBooks · doi:10.4018/978-1-4666-5125-8.ch042
Surgical Robotics in Ophthalmology
Ukey, B., & Agrawal, S. S. (2024) · DMIHER International Conference on Artificial Intelligence in Healthcare, Education and Industry (IDICAIHEI) · doi:10.1109/idicaiei61867.2024.10842927
“Reduced hand tremor allows for scaling motion and forces or achieving micrometer precision [1-2].”
Dario, P., Ciuti, G., Chiurazzi, M., Amram, D., Trigili, E., Crea, S., Vitiello, N., Masiero, F., Lanotte, F., Controzzi, M., et al. (2025) · Springer eBooks · doi:10.1007/978-3-319-77267-7_2
Development and Autonomous Tracking of Miniature Continuum Endscope for Intraocular Microsurgery
Wang, C., Jin, T., Wang, Y., Zhang, Z., Zhang, J., Zhang, J., Liang, J., Zhong, L., Zhang, H., & Zhao, J. (2025) · Lecture notes in computer science · doi:10.1007/978-981-95-2098-5_56 · Cited by 1
The Need for Robotics in Ophthalmology
Mishra, S. K. (2025) · EyeQuest · doi:10.4103/equest.equest_14_25
A vertical active handrest to aid in dexterous tasks and to provide gravitational support
Stewart, C. A. (2015) · J. Willard Marriott Library · doi:10.26053/0h-gpqn-0s00
Ferreira, M. A. [., Maia, M., Farah, M. E., & de Ávila, M. E. (2025) · Springer eBooks · doi:10.1007/978-3-031-29358-0_59-1
Research and Realization of an OCT-Guided Robotic System for Subretinal Injections
Li, Y., Wu, S., & Shi, G. (2026) · Actuators · doi:10.3390/act15010053
Control of meso-robots for endoluminal surgery
Secades, L. A. S. (2013) · theses.fr (ABES) · doi:10.70675/21e02714z81d0z4bb8za425z0928a3c0ed09
Sur la commande des robots manipulateurs industriels en co-manipulation robotique
Bahloul, A. (2018) · theses.fr (ABES) · doi:10.70675/beb9bc44z43f7z4adbzb8d1z99901d781bda · Cited by 4
Needle comanipulation with haptic guidance for percutaneous interventions
Gurnel, H. (2020) · theses.fr (ABES) · doi:10.70675/970a2fd3zd4b5z4f3czaa1czc9776ea19ead
Pedagogical Approaches for Surgical Education
Ferrier-Barbut, É. (2022) · theses.fr (ABES) · doi:10.70675/043bf326z7bc1z4feez892ez61be0383cd42
Clark, A., Currens, M., Kowalczyk, N., Rath, B., Quear, A., Towns, J., Murthy, A. S., & Song, S. (2026) · Machines · doi:10.3390/machines14050487
Auto-Manual Hybrid Mode for Teleoperation of Active Needles in Tissue Phantoms
Lee, S., Jung, S., Park, Y., Lee, J., Kim, S., Yu, S., & Ryu, S. C. (2025) · IEEE Conference on Telepresence · doi:10.1109/telepresence66096.2025.11521299
“The early studies focused on assisting manual needle steering, where robotic systems were primarily used to stabilize and enhance the precision by motion scaling or tremor corrections, improving targeting accuracy while still relying on the clinician’s expertise [2], [3].”
Hybrid Parallel‐Serial Tool Exchange Robot for Ophthalmic Precision Surgery: Mechanical Design
Lee, Y., Wu, Y.-C., Chen, Y., Chou, C., & Lin, C. (2026) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.70208
Raguž, M., Dlaka, D., Švaco, M., Marčinković, P., Romić, D., Šuligoj, F., Šekoranja, B., Chudy, D., & Jerbić, B. (2026) · Technology in Society · doi:10.1016/j.techsoc.2026.103475
Design and Implementation of a Test-bed for Virtual RCM Algorithms
Senanayaka, S. A. T., Abeysinghe, M. P., Amarasinghe, Y. W. R., & Jayathilaka, W. A. D. M. (2026) · Moratuwa Engineering Research Conference (MERCon) · doi:10.1109/mercon71835.2026.11691383
“Minimally Invasive Surgery (MIS) relies on the concept of the RCM to ensure that surgical instruments pivot at the incision site, thereby protecting the patient’s abdominal wall from lateral stress [1], [2].”
Ferreira, M. A., Maia, M., Farah, M. E., & Ávila, M. P. D. (2026) · Springer eBooks · doi:10.1007/978-3-032-23052-2_59
Hoxha, K., Henriques, A., Yang, J., Naheen, A., Tavakoli, M., & Nasseri, M. A. (2026) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra57385.2026.11695803
New family of near-Zero parasitic shift remote center of motion flexure-based pivots
Vallat, C., & Henein, S. (2026) · Mechanism and Machine Theory · doi:10.1016/j.mechmachtheory.2026.106645
Jukić, A., Pavan, J., Žužul, R. K., Ivančić, B. Đ., & Jukić, T. (2026) · Journal of Ophthalmology · doi:10.1155/joph/8100180
Metadata
- Authors
- Taylor, R., Jensen, P., Whitcomb, L., Barnes, A., Kumar, R., Stoianovici, D., Gupta, P., Wang, Z., Dejuan, E., & Kavoussi, L.
- Affiliations
- Johns Hopkins University (US)
- Wilmer Eye Institute, Johns Hopkins Medical Institutions, Johns Hopkins University, Baltimore, MD, USA
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 1999-12
- Volume
- 18
- Issue
- 12
- Pages
- 1201-1210
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2149985621
- Cited by
- 528
- References
- 43
- Citations by year
- 2026: 8 · 2025: 13 · 2024: 7 · 2023: 15 · 2022: 15 · 2021: 19 · 2020: 29 · 2019: 26 · 2018: 25 · 2017: 13 · 2016: 15 · 2015: 30 · 2014: 21 · 2013: 30 · 2012: 29
- FWCI
- 26.82
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- The International Journal of Robotics Research (publishedVersion)
- Funders
- National Science Foundation
- Johns Hopkins University
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Robot Manipulation and Learning
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Keywords
- microsurgery, force scaling, force sensing, human-robot interaction, tremor suppression, compliant manipulation, eye-hand coordination
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.