This paper reports the development of a robotic system designed to extend a human’s ability to perform small-scale (sub-millimeter) manipulation tasks requiring human judgment, sensory integration, and hand-eye coordination. Our novel approach, which we call steady-hand micromanipulation, is for tools to be held simultaneously both by the operator’s hand and a specially designed actively controlled robot arm. The robot’s controller senses forces exerted by the operator on the tool and by the tool on the environment, and uses this information in various control modes to provide smooth, tremor-free, precise positional control and force scaling. Our goal is to develop a manipulation system with the precision and sensitivity of a machine, but with the manipulative transparency and immediacy of hand-held tools for tasks characterized by compliant or semi-rigid contacts with the environment.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the 'steady-hand' approach of Taylor et al. [6], in which a robotic arm and the surgeon's hand hold the same instrument simultaneously, the robot sensing the force applied by the human hand and selectively complying in order to suppress unwanted components while allowing the desired movement.”
From Toward active tremor canceling in handheld microsurgical instruments (2003) · cites this paper as [6]
Citations
Cites
A telerobotic assistant for laparoscopic surgery
Taylor, R. H., Funda, J., Eldridge, B., Gomory, S., Gruben, K., LaRose, D., Talamini, M., Kavoussi, L., & Anderson, J. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.391776 · Cited by 392
Self-citationAn image-directed robotic system for precise orthopaedic surgery
Taylor, R. H., Mittelstadt, B. D., Paul, H. A., Hanson, W., Kazanzides, P., Zuhars, J. F., Williamson, B., Musits, B. L., Glassman, E., & Bargar, W. L. (1994) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.294202 · Cited by 347
Self-citationEj, L. (1997) · PubMed · Cited by 326
Space Robotics: Dynamics and Control
(1993) · The Kluwer International Series in Engineering and Computer Science · doi:10.1007/978-1-4615-3588-1 · Cited by 263 · cited 1×
“[17-19]); and 3) master-slave teleoperators (e.g., [ 20-22 ]).”
Tactile Display of Vibratory Information in Teleoperation and Virtual Environments
Kontarinis, D. A., & Howe, R. D. (1995) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.1995.4.4.387 · Cited by 251 · cited 1×
“We have begun preliminary experiments with vibrotactile displays (Kontarinis and Howe 1995).”
Teleoperation, telerobotics and telepresence: A progress report
Sheridan, T. B. (1995) · Control Engineering Practice · doi:10.1016/0967-0661(94)00078-u · Cited by 243
Comparative experiments with a new adaptive controller for robot arms
Whitcomb, L. L., Rizzi, A. A., & Koditschek, D. E. (1993) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.210795 · Cited by 236
Self-citationA modular surgical robotic system for image guided percutaneous procedures
Stoianovici, D., Whitcomb, L. L., Anderson, J. H., Taylor, R. H., & Kavoussi, L. R. (1998) · Lecture Notes in Computer Science · doi:10.1007/bfb0056225 · Cited by 174 · cited 1×
“We have applied the RCM in conjunction with the PAKY needle driver for performing image guided renal access [45, 46].”
Self-citationKazerooni, H., & Guo, J. (1993) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.2899068 · Cited by 119
Modeling and canceling tremor in human-machine interfaces
Riviere, C. N., & Thakor, N. V. (1996) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.499755 · Cited by 114 · cited 2×
“Our immediate goal is a rigorous evaluation of the completed system as a microsurgery augmentation aid, using test environments developed by our colleagues at JHU’s Wilmer Eye Institute and CMU (Humayun et al. 1997; Riviere and Thakor 1996; Riviere and Khosla 1999a, 1999b).”
Research works printed but not linked: 10
- Bargar, W., etal. 1995 (Baltimore, MD). Robodoc Multicenter trial: An interim report . Proc. of the 2nd Intl. Symp. on Medical Robot. and Comp.Assisted Surgery, MRCAS ’95. Pittsburgh, PA: C/O Center for Orthop. Res., Shadyside Hospital.
- Charles, S. 1994. Dexterity enhancement for surgery . Proc. of the First Intl. Symp. on Medical Robot. and Comp.Assisted Surgery, vol. 2, pp. 145–160 .
- Cho, Y., Kotoku, T., and Tanie, K. 1995 (Pittsburgh, PA). Discrete-event-planning and control of telerobotic part mating process with communication delay in geometric uncertainty . Proc. of the IEEE Conf. on Intell. Robot. and Sys. Washington, DC: IEEE Press.
- Dinsmoor, C., and Hagermann, P. 1993 (Detroit, MI). Fanuc robotics system r-j controller . Proc. of the Intl. Robots and Vision Automat. Conf.
- Funda, J., et al. 1994. Image-guided command and control of a surgical robot . Proc. Med. Meets Virtual Reality II. San Diego, CA.
- Kazerooni, H. 1989b. Human/robot interaction via the transfer of power and information signals—part II: Dynamics and control analysis. Proc. of the IEEE Conf. on Robot. and Automat. Los Alamitos, CA: IEEE .
- Kumar, R., et al. 1997 (Tokyo, Japan). Robot-assisted microneurosurgical procedures, comparative dexterity experiments . Proc. of the Society for Minimally Invasive Therapy, 9th Annual Meeting, abstract book vol. 6, suppl. 1.
- Mindell, D. A., et al. 1993. JasonTalk: A standard ROV vehicle control system. Proc. of IEEE/MTS OCEANS’93. Los Alamitos, CA: IEEE .
- Mittelstadt, B. D., et al. 1994. The evolution of a surgical robot from prototype to human clinical trial . Proc. of the Intl. Symp. on Medical Robot. and Comp.Assisted Surgery. Pittsburgh, PA.
- Stoianovici, D., et al. 1998. A modular surgical robotic system for image-guided percutaneous procedures. Medical Image Computing and Comp.Assisted Interventions (MICCAI-98). 1998. Cambridge, MA: Springer . · DOI · Paper page
Cited by
Items 201–300 of 528
Zhang, T., Gong, L., Wang, S., & Zuo, S. (2019) · Annals of Biomedical Engineering · doi:10.1007/s10439-019-02358-2 · Cited by 23
An ungrounded hand-held surgical device incorporating active constraints with force-feedback
Payne, C. J., Kwok, K., & Yang, G. (2013) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2013.6696717 · Cited by 30
“Force-feedback is also provided to the operator so as to indicate penetration of the active constraint boundary by the surgical tool.”
A novel dual force sensing instrument with cooperative robotic assistant for vitreoretinal surgery
He, X., Balicki, M. A., Gehlbach, P. L., Handa, J. T., Taylor, R. H., & Iordachita, I. I. (2013) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2013.6630578 · Cited by 27
Self-citationActive Constraints Using Vector Field Inequalities for Surgical Robots
Marinho, M. M., Adorno, B. V., Harada, K., & Mitsuishi, M. (2018) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2018.8461105 · Cited by 21
Physiological Tremor Filtering Without Phase Distortion for Robotic Microsurgery
Adhikari, K., Tatinati, S., Veluvolu, K. C., & Chambers, J. A. (2020) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2020.3041427 · Cited by 22
Abadi, A. S. S., Ordys, A., Kukiełka, K., & Pierscionek, B. K. (2023) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.2524 · Cited by 25
Liu, S., Xia, Z., Liu, J., Xu, J. L., Ren, H. J., Lu, T., & Yang, X. (2016) · PLoS ONE · doi:10.1371/journal.pone.0149482 · Cited by 21
Riojas, K. E., & Labadie, R. F. (2020) · Otolaryngologic Clinics of North America · doi:10.1016/j.otc.2020.07.014 · Cited by 21
A new Micromanipulator System for middle ear surgery
Maier, T., Strauß, G., Hofer, M., Kraus, T. M., Runge, A., Stenzel, R., Gumprecht, J. D. J., Berger, T., Dietz, A., & Lueth, T. C. (2010) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2010.5509594 · Cited by 27
An Error Compensation Method for Surgical Robot Based on RCM Mechanism
Bai, M., Zhang, M., Zhang, H., Pang, L., Zhao, J., & Gao, C. (2021) · IEEE Access · doi:10.1109/access.2021.3117350 · Cited by 22
“INTRODUCTION In minimally invasive surgery (MIS), surgical instruments are operated through incision, and the remote center of motion (RCM) mechanism uses mechanical constraints to realize movement around the remote center of motion point (RCM point) [1]–[3], which provides a fixed point for the robot in the surgical…”
Effect of Impedance-Shaping on Perception of Soft Tissues in Macro-Micro Teleoperation
Son, H. I., Bhattacharjee, T., & Hashimoto, H. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2148672 · Cited by 20
Physiological tremor sensing using only accelerometers for real-time compensation
Latt, W. T., Tan, U.-X., Veluvolu, K. C., Shee, C. Y., & Ang, W. T. (2009) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2009.4913049 · Cited by 21
Virtual fixtures for bilateral telemanipulation
Okamura, A. M., & Abbott, J. J. (2006) · Cited by 20
Hybrid Robot-Assisted Frameworks for Endomicroscopy Scanning in Retinal Surgeries
Li, Z., Shahbazi, M., Patel, N. A., O'Sullivan, E., Zhang, H., Vyas, K., Chalasani, P., Deguet, A., Gehlbach, P. L., Iordachita, I. I., et al. (2020) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2020.2988312 · Cited by 21
Self-citationA Framework for Multilateral Manipulation in Surgical Tasks
Nichols, K. A., & Okamura, A. M. (2015) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2015.2499195 · Cited by 19
A new hand-held force-amplifying device for micromanipulation
Payne, C. J., Latt, W. T., & Yang, G. (2012) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2012.6225306 · Cited by 23
A new ENT microsurgery robot: Error analysis and implementation
He, C., Olds, K. C., Iordachita, I. I., & Taylor, R. H. (2013) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2013.6630727 · Cited by 19
Self-citationPositioning Accuracy of Neurosurgeons
Sandoval, R., MacLachlan, R. A., Oh, M. Y., & Riviere, C. N. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352259 · Cited by 23
Development of a New Robotic Forceps Manipulator for Minimally Invasive Surgery and Its Control
Ishii, C., & Kobayashi, K. (2006) · SICE-ICASE International Joint Conference · doi:10.1109/sice.2006.315616 · Cited by 19
Koo, D., Park, H.-C., Gehlbach, P. L., & Song, C. O. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.004816 · Cited by 20
Robot-assisted retinal surgery: overcoming human limitations
Xue, K., Edwards, T. L., Meenink, H. C. M., Beelen, M. J., Naus, G. J. L., Simunovic, M. P., de Smet, M. D., & MacLaren, R. E. (2019) · Retina Atlas · doi:10.1007/978-981-13-6214-9_11 · Cited by 18
ASAP: A Semi-Autonomous Precise System for Telesurgery During Communication Delays
Gonzalez, G., Balakuntala, M. V., Agarwal, M., Low, T., Knoth, B., Kirkpatrick, A. W., McKee, J. L., Hager, G. D., Aggarwal, V., Xue, Y., et al. (2023) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2023.3239674 · Cited by 31
A Semi-Autonomous Stereotactic Brain Biopsy Robot With Enhanced Safety
Ye, M., Li, W., Chan, D. T. M., Chiu, P. W. Y., & Li, Z. (2020) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2020.2967732 · Cited by 18
Development of a novel mechanism for minimally invasive surgery
Li, J., Wang, S., Wang, X., He, C., & Zhang, L. (2010) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2010.5723529 · Cited by 18
Berkelman, P. J., Rothbaum, D. L., Roy, J., Lang, S., Whitcomb, L. L., Hager, G., Jensen, P. S., de Juan, E., Taylor, R. H., & Niparko, J. K. (2001) · Lecture notes in computer science · doi:10.1007/3-540-45468-3_255 · Cited by 23
“Examples include robotic extenders that directly amplify human strength [113], passive devices that directt human task execution [4] [5], and active devices that assist in the execution of fine manipulation tasks [668].”
Self-citationEffects of Velocity on Human Force Control
Wu, M. M., Abbott, J. J., & Okamura, A. M. (2005) · IEEE World Haptics Conference (WHC) · doi:10.1109/whc.2005.49 · Cited by 18
Li, H.-Y., Yang, L., & Tan, U.-X. (2020) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2020.3010450 · Cited by 17
ColibriDoc: an Eye-in-Hand Autonomous Trocar Docking System
Dehghani, S., Sommersperger, M., Yang, J., Salehi, M., Busam, B., Huang, K., Gehlbach, P. L., Iordachita, I. I., Navab, N., & Nasseri, M. A. (2022) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra46639.2022.9811364 · Cited by 20
Kinematics and synthesis of a type of mechanisms with multiple remote centers of motion
Bai, G., Li, D., Wei, S., & Liao, Q. (2014) · Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science · doi:10.1177/0954406214527915 · Cited by 17
Payne, C. J., Vyas, K., Bautista‐Salinas, D., Zhang, D., Marcus, H. J., & Yang, G. (2020) · Neuromethods · doi:10.1007/978-1-0716-0993-4_4 · Cited by 23
Seifabadi, R., Aalamifar, F., Iordachita, I. I., & Gabor Fichtinger, A. (2015) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.1692 · Cited by 17
Robotic technology in ophthalmic surgery
Jeganathan, V. S. E., & Shah, S. (2009) · Current Opinion in Ophthalmology · doi:10.1097/icu.0b013e328333371d · Cited by 19
MRI-compatible hands-on cooperative control of a pneumatically actuated robot
Kapoor, A., Wood, B. J., Mazilu, D., Horvath, K. A., & Li, M. (2009) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2009.5152541 · Cited by 17
Cagneau, B., Morel, G., Bellot, D., Zemiti, N., & d'Agostino, G. A. (2008) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2008.4543513 · Cited by 17
Cheon, G. W., Gonenc, B., Taylor, R. H., Gehlbach, P. L., & Kang, J. U. (2017) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2017.2749384 · Cited by 18
Self-citationDesign and Control of Fully Handheld Microsurgical Robot for Active Tremor Cancellation
Kim, E., Choi, I., & Yang, S. (2021) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra48506.2021.9561200 · Cited by 19
A novel control architecture for physiological tremor compensation in teleoperated systems
Ghorbanian, A., Zareinejad, M., Rezaei, S. M., Sheikhzadeh, H., & Baghestan, K. (2012) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.1436 · Cited by 17
“xrk 1⁄4 sin 2p f min þ rΔ f ð Þk ð Þ 1≤r≤l cos 2p f min þ rΔ f ð Þk ð Þ lþ 1≤r≤2 l 1 2lþ 1 (8)<: (2)”
Needle Localization for Robot-assisted Subretinal Injection based on Deep Learning
Zhou, M., Wang, X., Weiß, J., Eslami, A., Huang, K., Maier, M. M., Lohmann, C. P., Navab, N., Knoll, A., & Nasseri, M. A. (2019) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2019.8793756 · Cited by 17
SARTRES: a semi-autonomous robot teleoperation environment for surgery
Rahman, M. M., Balakuntala, M. V., Gonzalez, G., Agarwal, M., Kaur, U., Venkatesh, V. L. N., Sanchez‐Tamayo, N., Xue, Y., Voyles, R. M., Aggarwal, V., et al. (2020) · Computer Methods in Biomechanics and Biomedical Engineering Imaging & Visualization · doi:10.1080/21681163.2020.1834878 · Cited by 17
Effect of Grip Force and Training in Unstable Dynamics on Micromanipulation Accuracy
Su, E. L. M., Ganesh, G., Yeong, C. F., Teo, C. L., Ang, W. T., & Burdet, E. (2011) · IEEE Transactions on Haptics · doi:10.1109/toh.2011.33 · Cited by 17
Stereotactic technology for 3D bioprinting: from the perspective of robot mechanism
Tan, B., Kuang, S., Li, X., Cheng, X., Duan, W., Zhang, J., Liu, W., & Fan, Y. (2021) · Biofabrication · doi:10.1088/1758-5090/ac1846 · Cited by 19
“They further optimized the RCM robotic arm in terms of precision (to sub-millimeter) and system compatibility in 1999 by adding the capacity to sense forces exerted by both the operator and the surgical tools [38].”
Implicit Active Constraints for robot-assisted arthroscopy
Lopez, E., Kwok, K., Payne, C. J., Γιαταγάνας, Π., & Yang, G. (2013) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2013.6631350 · Cited by 16
“In addition to these mechanisms intended for teleoperated systems, a RCM mechanism was proposed for a hands-on cooperatively-controlled robotic platform [17].”
Application of shared control strategy in the design of a robotic device
Payandeh, S. (2001) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2001.945693 · Cited by 16
Conceptual design and dimensional synthesis of “MicroHand”
Wang, S., Yue, L., Li, Q., & Ding, J. (2007) · Mechanism and Machine Theory · doi:10.1016/j.mechmachtheory.2007.08.003 · Cited by 15
Kinematic Analysis and Dimensional Synthesis of a Meso-Gripper
Bai, G., Kong, X., & Ritchie, J. M. (2016) · ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference (IDETC/CIE) · doi:10.1115/detc2016-59526 · Cited by 15
Real-Time Image-Guided Cooperative Robotic Assist Device for Deep Anterior Lamellar Keratoplasty
Draelos, M., Keller, B., Tang, G., Kuo, A. N., Hauser, K. K., & Izatt, J. A. (2018) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2018.8463153 · Cited by 20
Creation of an Automated Fluorescence Guided Tumor Ablation System
Tucker, M. B., Ma, G., Ross, W., Buckland, D. M., & Codd, P. J. (2021) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2021.3097210 · Cited by 15
Performance of a 6-degree-of-freedom active microsurgical manipulator in handheld tasks
Yang, S., Wells, T. S., MacLachlan, R. A., & Riviere, C. N. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610837 · Cited by 18
Suturing and tying knots assisted by a surgical robot system in laryngeal MIS
Wang, H., Wang, S., Ding, J., & Luo, H. (2009) · Robotica · doi:10.1017/s0263574709990622 · Cited by 15
“gxy(t) ∈ SE(3), gxy(t) = [ Rxy qxy(t) 0 1 ]”
InfluentialEffect of Hand Dynamics on Virtual Fixtures for Compliant Human-Machine Interfaces
Marayong, P., Hager, G. D., & Okamura, A. M. (2006) · IEEE Conference on Virtual Reality and 3D User Interfaces (VR) · doi:10.1109/vr.2006.56 · Cited by 15
Setup and Method for Remote Center of Motion Positioning Guidance During Robot-Assisted Surgery
Smits, J., Reynaerts, D., & Poorten, E. V. (2019) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros40897.2019.8968288 · Cited by 15
An Optimized Tilt Mechanism for a New Steady-Hand Eye Robot
Wu, J., Li, G., Urias, M. G., Patel, N. A., Liu, Y., Gehlbach, P. L., Taylor, R. H., & Iordachita, I. I. (2020) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros45743.2020.9340741 · Cited by 19
Self-citationForce-based flexible path plans for robotic electrode insertion
Pile, J., Wanna, G. B., & Simaan, N. (2014) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2014.6906625 · Cited by 15
neural network methods for error canceling in human-machine manipulation
Ang, W. T., & Riviere, C. N. (2005) · 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2001.1019575 · Cited by 15
A force-sensing surgical drill for real-time force feedback in robotic mastoidectomy
Chen, Y., Goodridge, A., Sahu, M., Kishore, A., Vafaee, S., Mohan, H., Sapozhnikov, K., Creighton, F. X., Taylor, R. H., & Galaiya, D. J. (2023) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-023-02873-7 · Cited by 14
Self-citationIntraoperative Visualization of Anatomical Targets in Retinal Surgery
Fleming, I. N., Voros, S., Vágvölgyi, B., Pezzementi, Z. A., Handa, J., Taylor, R., & Hager, G. D. (2008) · Proceedings · doi:10.1109/wacv.2008.4544034 · Cited by 16
Self-citationThe era of robotics: dexterity for surgery and medical care: narrative review
Balasubramanian, S., Chenniah, J., Gurumurthy, B., & Vellaipandi, V. (2020) · International Surgery Journal · doi:10.18203/2349-2902.isj20201057 · Cited by 14
MODELING OF NEEDLE INSERTION FORCES FOR PERCUTANEOUS THERAPIES
Simone, C. (2002) · Cited by 28
Performance Envelope and Physiological Tremor in Microsurgery
Ibanez, D. O., Baquerin, F. P., Choi, D. Y., & Riviere, C. N. (2006) · IEEE Annual Northeast Bioengineering Conference (NEBEC) · doi:10.1109/nebc.2006.1629782 · Cited by 16
“Several types of engineered accuracyenhancement devices have been or are being developed in order to improve the manipulation accuracy of the microsurgeon , including telerobotic systems [1], the " steady-hand " robotic system [2], and a handheld micromanipulator with active tremor canceling [3].”
Human/robotic interaction: vision limits performance in simulated vitreoretinal surgery
de Smet, M. D., de Jonge, N., Iannetta, D., Faridpooya, K., van Oosterhout, E., Naus, G., Meenink, T. C. M., Mura, M., & Beelen, M. J. (2019) · Acta Ophthalmologica · doi:10.1111/aos.14003 · Cited by 13
Taylor, R. H., & Kazanzides, P. (2008) · Advances in computers · doi:10.1016/s0065-2458(08)00405-1 · Cited by 14
Self-citationOn the Ability of Humans to Apply Controlled Forces to Admittance-Type Devices
Nambi, M., Provancher, W. R., & Abbott, J. J. (2011) · Advanced Robotics · doi:10.1163/016918611x558234 · Cited by 14
Haptic feedback augmentation through position based adaptive force scaling: theory and experiment
Roy, J., Rothbaum, D. L., & Whitcomb, L. L. (2003) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/irds.2002.1041714 · Cited by 13
Self-citationControl methods for guidance virtual fixtures in compliant human-machine interfaces
Marayong, P., Hager, G. D., & Okamura, A. M. (2008) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2008.4650838 · Cited by 13
System to Assess Accuracy of Micromanipulation
Latt, W. T., Tan, U. X., Veluvolu, K. C., Lin, J. K. D., Shee, C. Y., & Ang, W. T. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4353651 · Cited by 13
Gentry, S. E. (2005) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 19
Active Handrest: A large workspace tool for precision manipulation
Fehlberg, M. A., Gleeson, B. T., & Provancher, W. R. (2012) · The International Journal of Robotics Research · doi:10.1177/0278364911432895 · Cited by 12
Mablekos-Alexiou, A., Ourselin, S., da Cruz, L., & Bergeles, C. (2018) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2018.8460921 · Cited by 14
Monocular Vision-Based Retinal Membrane Peeling With a Handheld Robot
Han, Y., Routray, A., Adeghate, J. O., MacLachlan, R. A., Martel, J. N., & Riviere, C. N. (2021) · Journal of Medical Devices · doi:10.1115/1.4051686 · Cited by 12
Robotic assisted microsurgery in hypothenar hammer syndrome: a case report
Facca, S., & Liverneaux, P. A. (2010) · Computer Aided Surgery · doi:10.3109/10929088.2010.507942 · Cited by 12
Direct global adjustment methods for endoscopic mosaicking
Seshamani, S., Smith, M. D., Corso, J. J., Filipovich, M. O., Natarajan, A., & Hager, G. D. (2009) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.812246 · Cited by 12
Intramedullary Nail Distal Hole Axis Estimation using Blob Analysis and Hough Transform
Neatpisarnvanit, C., & Suthakorn, J. (2006) · IEEE Conference on Robotics, Automation and Mechatronics (RAM) · doi:10.1109/ramech.2006.252685 · Cited by 12
Evaluation of a Force-Sensing Handheld Robot for Assisted Retinal Vein Cannulation
Gonenc, B., Patel, N. A., & Iordachita, I. I. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513304 · Cited by 12
“Challenges of RVC procedure such as need for precise needle placement inspired development of robotic assistants aiding in removing hand tremor [7] and non-perceivable needle-vein interaction forces lead to development of micro-force-sensing surgical instruments for providing force feedback [8], [9].”
Statistical Shape Model of the Temporal Bone Using Segmentation Propagation
Ding, A. S., Lu, A., Li, Z., Galaiya, D. J., Ishii, M., Siewerdsen, J. H., Taylor, R. H., & Creighton, F. X. (2022) · Otology & Neurotology · doi:10.1097/mao.0000000000003554 · Cited by 12
Self-citationHand-Held Force Magnifier for Surgical Instruments: Evolution toward a Clinical Device
Lee, R., Wu, B., Klatzky, R. L., Shivaprabhu, V., Galeotti, J., Horvath, S., Siegel, M., Schuman, J. S., Hollis, R. L., & Stetten, G. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-38085-3_9 · Cited by 12
“[6][7].”
Song, C. O., Gehlbach, P. L., & Kang, J. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346202 · Cited by 15
Robot-assisted endoscopic exploration of the spinal cord
Ascari, L., Stefanini, C., Bertocchi, U., & Dario, P. (2010) · Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science · doi:10.1243/09544062jmes2017 · Cited by 12
Adaptive force control of position/velocity controlled robots: theory and experiment
Roy, J., & Whitcomb, L. L. (2002) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2001.976374 · Cited by 12
Self-citationUltrasound-, CT- and MR-Guided Robot-Assisted Interventions
Kettenbach, J., Kronreif, G., Melzer, A., Gabor Fichtinger, A., Stoianovici, D. S., & Cleary, K. (2007) · Springer eBooks · doi:10.1007/978-3-540-49830-8_28 · Cited by 12
Self-citationA micro motion sensing system for micromanipulation tasks
Latt, W. T., Tan, U.-X., Georgiou, A., Sidarta, A., Riviere, C. N., & Ang, W. T. (2011) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2011.09.009 · Cited by 12
“Several types of engineered accuracy enhanceent devices have been or are being developed in order to improve anipulation accuracy of microsurgeons, including telerobotic sysems [6], the “steady-hand” robotic system [7], and fully hand-held”
Intention Recognition in Human Machine Collaborative Systems
Aarno, D. (2007) · KTH Publication Database DiVA (KTH Royal Institute of Technology) · Cited by 12
Teleoperated Micromanipulation System Manufactured by Cut-and-Fold Techniques
Yim, S., Miyashita, S., Rus, D. L., & Kim, S. (2017) · IEEE Transactions on Robotics · doi:10.1109/tro.2016.2636904 · Cited by 13
Chen, C., Chen, H.-C., Yang, H., Zeng, X.-Y., Wu, X., & Chen, P. (2021) · Mechanism and Machine Theory · doi:10.1016/j.mechmachtheory.2021.104568 · Cited by 12
Performance of Surgical Robots with Automatically Generated Spatial Virtual Fixtures
Li, M., & Taylor, R. H. (2006) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2005.1570122 · Cited by 11
“Our experimental system is based on the JHU Steady-Hand Robot [14].”
Self-citationActive Handrest for precision manipulation and ergonomic support
Fehlberg, M. A., Gleeson, B. T., Leishman, L. C., & Provancher, W. R. (2010) · IEEE Haptics Symposium · doi:10.1109/haptic.2010.5444613 · Cited by 11
Hands-on reconfigurable robotic surgical instrument holder arm
Wisanuvej, P., Leibrandt, K., Liu, J., & Yang, G. (2016) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2016.7759385 · Cited by 13
Toward monocular camera-guided retinal vein cannulation with an actively stabilized handheld robot
Mukherjee, S., Yang, S., MacLachlan, R. A., Lobes, L. A., Martel, J. N., & Riviere, C. N. (2017) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2017.7989341 · Cited by 14
“The Steady Hand robot developed at JHU receives input in the form of force/torque and allows voluntary motion while suppressing tremor through selective compliance [3], [4].”
Dual optical coherence tomography sensor guided, two-motor, horizontal SMART micro-scissors
Yeo, C., Park, H.-C., Jang, S., Gehlbach, P. L., & Song, C. O. (2016) · Optics Letters · doi:10.1364/ol.41.004723 · Cited by 11
Towards A Compliant and Accurate Cooperative Micromanipulator using Variable Admittance Control
Li, H.-Y., Nuradha, T., Xavier, S. A., & Tan, U.-X. (2018) · International Conference on Advanced Robotics and Mechatronics (ICARM) · doi:10.1109/icarm.2018.8610853 · Cited by 12
The janus syndrome: a perspective on a new era of computer-enhanced robotic cardiac surgery
Boyd, W. D., & Stahl, K. D. (2003) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(02)73573-3 · Cited by 11
Wide-area haptic guidance: Taking the user by the hand
Arias, A., & Hanebeck, U. D. (2010) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2010.5654382 · Cited by 10
Zhang, Z., Yu, H., & Du, Z. (2015) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2015.7237570 · Cited by 10
Kinematic Analysis of a Mechanism With Dual Remote Centre of Motion and its Potential Application
Bai, G., Qi, P., Althoefer, K. A., Li, D., Kong, X., & Dai, J. S. (2015) · ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference (IDETC/CIE) · doi:10.1115/detc2015-47118 · Cited by 10
Horise, Y., He, X., Gehlbach, P. L., Taylor, R. H., & Iordachita, I. I. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318249 · Cited by 13
Self-citationImage‐Guided Mastoidectomy with a Cooperatively Controlled ENT Microsurgery Robot
Razavi, C. R., Wilkening, P. R., Yin, R., Barber, S. R., Taylor, R. H., Carey, J. P., & Creighton, F. X. (2019) · Otolaryngology · doi:10.1177/0194599819861526 · Cited by 10
Self-citationBridging 3D Slicer and ROS2 for Image-Guided Robotic Interventions
Connolly, L., Deguet, A., Léonard, S., Tokuda, J., Ungi, T., Krieger, A., Kazanzides, P., Mousavi, P., Gabor Fichtinger, A., & Taylor, R. H. (2022) · Sensors · doi:10.3390/s22145336 · Cited by 10
Self-citationAn intelligent hand-held microsurgical instrument for improved accuracy
Ang, W. T., Khosla, P. K., & Riviere, C. N. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2001.1019572 · Cited by 12
Incorporating Geometric Algorithms in Impedance- and Admittance-Type Haptic Rendering
Kikuuwe, R., & FUJIMOTO, H. (2007) · IEEE World Haptics Conference (WHC) · doi:10.1109/whc.2007.75 · Cited by 11
Models of human-centered automation in a debridement task
Nichols, K. A., Murali, A., Sen, S., Goldberg, K., & Okamura, A. M. (2015) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2015.7354198 · Cited by 10
Xiao, J., Wu, Q., Sun, D., He, C., & Chen, Y. (2019) · International Conference on Intelligent Transportation, Big Data & Smart City (ICITBS) · doi:10.1109/icitbs.2019.00122 · Cited by 11
Metadata
- Authors
- Taylor, R., Jensen, P., Whitcomb, L., Barnes, A., Kumar, R., Stoianovici, D., Gupta, P., Wang, Z., Dejuan, E., & Kavoussi, L.
- Affiliations
- Johns Hopkins University (US)
- Wilmer Eye Institute, Johns Hopkins Medical Institutions, Johns Hopkins University, Baltimore, MD, USA
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 1999-12
- Volume
- 18
- Issue
- 12
- Pages
- 1201-1210
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2149985621
- Cited by
- 528
- References
- 43
- Citations by year
- 2026: 8 · 2025: 13 · 2024: 7 · 2023: 15 · 2022: 15 · 2021: 19 · 2020: 29 · 2019: 26 · 2018: 25 · 2017: 13 · 2016: 15 · 2015: 30 · 2014: 21 · 2013: 30 · 2012: 29
- FWCI
- 26.82
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- The International Journal of Robotics Research (publishedVersion)
- Funders
- National Science Foundation
- Johns Hopkins University
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Robot Manipulation and Learning
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Keywords
- microsurgery, force scaling, force sensing, human-robot interaction, tremor suppression, compliant manipulation, eye-hand coordination
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.