Using physiologically-based pharmacokinetic-guided “body-on-a-chip” systems to predict mammalian response to drug and chemical exposure
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
The continued development of in vitro systems that accurately emulate human response to drugs or chemical agents will impact drug development, our understanding of chemical toxicity, and enhance our ability to respond to threats from chemical or biological agents. A promising technology is to build microscale replicas of humans that capture essential elements of physiology, pharmacology, and/or toxicology (microphysiological systems). Here, we review progress on systems for microscale models of mammalian systems that include two or more integrated cellular components. These systems are described as a “body-on-a-chip”, and utilize the concept of physiologically-based pharmacokinetic (PBPK) modeling in the design. These microscale systems can also be used as model systems to predict whole-body responses to drugs as well as study the mechanism of action of drugs using PBPK analysis. In this review, we provide examples of various approaches to construct such systems with a focus on their physiological usefulness and various approaches to measure responses (e.g. chemical, electrical, or mechanical force and cellular viability and morphology). While the goal is to predict human response, other mammalian cell types can be utilized with the same principle to predict animal response. These systems will be evaluated on their potential to be physiologically accurate, to provide effective and efficient platform for analytics with accessibility to a wide range of users, for ease of incorporation of analytics, functional for weeks to months, and the ability to replicate previously observed human responses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250 · cited 3×
“During the past 1–5 years, many systems have been developed with the aim of reproducing specific organ functions, such as the blood vessels (37, 38), liver (39, 40), gastrointestinal tract (41, 42), blood-brain-barrier (43–45), lung (46, 47), kidney (48–50) and heart (51, 52).”
Physiological Parameters in Laboratory Animals and Humans
Davies, B., & Morris, T. (1993) · Pharmaceutical Research · doi:10.1023/a:1018943613122 · Cited by 2,926
The blood-brain barrier/neurovascular unit in health and disease
Hawkins, B. T., & Davis, T. P. (2005) · Pharmacological Reviews · doi:10.1124/pr.57.2.4 · Cited by 2,661 · cited 1×
“Disruption of the barrier tissue integrity leads to increases in permeability and loss of barrier functionality, and it is associated with the development and progression of several diseases, such as gastrointestinal autoimmune diseases or neuroinflammatory diseases (98, 99).”
Pericytes are required for blood–brain barrier integrity during embryogenesis
Daneman, R., Zhou, L., Kebede, A. A., & Barres, B. A. (2010) · Nature · doi:10.1038/nature09513 · Cited by 2,128 · cited 1×
“TEER measurements are traditionally performed using commercially available systems, normally consisting of a pair of Ag/AgCl electrodes, to record the low frequency resistance of confluent cell monolayers grown on porous membranes (100, 101).”
Microscale culture of human liver cells for drug development
Khetani, S. R., & Bhatia, S. N. (2008) · Nature Biotechnology · doi:10.1038/nbt1361 · Cited by 1,219 · cited 2×
“During the past 1–5 years, many systems have been developed with the aim of reproducing specific organ functions, such as the blood vessels (37, 38), liver (39, 40), gastrointestinal tract (41, 42), blood-brain-barrier (43–45), lung (46, 47), kidney (48–50) and heart (51, 52).”
A Human Disease Model of Drug Toxicity–Induced Pulmonary Edema in a Lung-on-a-Chip Microdevice
Huh, D., Leslie, D. C., Matthews, B. D., Fraser, J. P., Jurek, S., Hamilton, G. A., Thorneloe, K. S., McAlexander, M. A., & Ingber, D. E. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004249 · Cited by 993 · cited 1×
“This device was further used to reproduce drug-induced pulmonary edema.(57) Natarajan et al.”
In vitro microvessels for the study of angiogenesis and thrombosis
Zheng, Y., Chen, J., Craven, M., Choi, N. W., Totorica, S., Diaz-Santana, A., Kermani, P., Hempstead, B., Fischbach-Teschl, C., López, J. A., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1201240109 · Cited by 894
Pharmacokinetics and pharmacodynamics of systemically administered glucocorticoids.
Czock, D., Keller, F., Rasche, F. M., & H??ussler, U. (2005) · Clinical Pharmacokinetics · doi:10.2165/00003088-200544010-00003 · Cited by 886 · cited 1×
“A two-compartment model can be used to describe the distribution time of such drugs (10).”
Engineering of functional, perfusable 3D microvascular networks on a chip
Kim, S., Lee, H., Chung, M., & Jeon, N. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41320a · Cited by 872 · cited 1×
“During the past 1–5 years, many systems have been developed with the aim of reproducing specific organ functions, such as the blood vessels (37, 38), liver (39, 40), gastrointestinal tract (41, 42), blood-brain-barrier (43–45), lung (46, 47), kidney (48–50) and heart (51, 52).”
Fasano, A., & Shea-Donohue, T. (2005) · Nature Clinical Practice Gastroenterology & Hepatology · doi:10.1038/ncpgasthep0259 · Cited by 484
Wagner, I., Materne, E.-M., Brincker, S., Süßbier, U., Frädrich, C., Busek, M., Sonntag, F., Sakharov, D. A., Trushkin, E. V., Tonevitsky, A. G., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50234a · Cited by 476 · cited 1×
“Wagner et al reported the development of a multiorgan-on-a-chip for long term cultivation of 3D human liver cells and skin tissue (73).”
In Vitro Perfused Human Capillary Networks
Moya, M. L., Hsu, Y.-H., Lee, A. P., Hughes, C. C. W., & George, S. C. (2013) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2012.0430 · Cited by 387
Zhang, C., Zhao, Z., Abdul Rahim, N. A., van Noort, D., & Yu, H. (2009) · Lab on a Chip · doi:10.1039/b915147h · Cited by 340 · cited 2×
“reported a multi-channel 3D microfluidic system, where aggregates of four different cell types (representing liver, lung, adipose and kidney) were cultured (71).”
Microfluidic Endothelium for Studying the Intravascular Adhesion of Metastatic Breast Cancer Cells
Song, J. W., Cavnar, S. P., Walker, A. C., Luker, K. E., Gupta, M., Tung, Y.-C., Luker, G. D., & Takayama, S. (2009) · PLoS ONE · doi:10.1371/journal.pone.0005756 · Cited by 317 · cited 1×
“Specific systems to emulate biological processes, such as metastasis (53), vasculogenesis (54), angiogenesis (55), and chemotaxis (56) have also been developed.”
van Midwoud, P. M., Merema, M. T., Verpoorte, E., & Groothuis, G. M. M. (2010) · Lab on a Chip · doi:10.1039/c0lc00043d · Cited by 203
Recapitulating maladaptive, multiscale remodeling of failing myocardium on a chip
McCain, M. L., Sheehy, S. P., Grosberg, A., Goss, J. A., & Parker, K. K. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1304913110 · Cited by 163 · cited 1×
“Cardiac myocytes cultured on a stretchable substrate and stretched in longitudinal and transverse directions have been used to measure contractile stress generation (88).”
On being the right size: scaling effects in designing a human-on-a-chip
Moraes, C., Labuz, J. M., Leung, B. M., Inoue, M., Chun, T.-H., & Takayama, S. (2013) · Integrative Biology · doi:10.1039/c3ib40040a · Cited by 134 · cited 2×
“The issue of scaling in body-on-a-chip systems has been discussed in recent studies (7, 27).”
Microfluidic devices for in vitro studies on liver drug metabolism and toxicity
van Midwoud, P. M., Verpoorte, E., & Groothuis, G. M. M. (2011) · Integrative Biology · doi:10.1039/c0ib00119h · Cited by 115 · cited 1×
“Primary hepatocytes also offer good prediction value for in vivo metabolic profiles, but suffer from the absence of nonparenchymal cells and loss of activity upon cell culture (13).”
Cited by
TEER Measurement Techniques for In Vitro Barrier Model Systems
Srinivasan, B., Kolli, A. R., Esch, M. B., Abaci, H. E., Shuler, M. L., & Hickman, J. J. (2015) · SLAS Technology · doi:10.1177/2211068214561025 · Cited by 2,145
Self-citationIn silico toxicology: computational methods for the prediction of chemical toxicity
Raies, A. B., & Bajic, V. B. (2016) · WIREs Computational Molecular Science · doi:10.1002/wcms.1240 · Cited by 744
3D printed microfluidics for biological applications
Ho, C. M. B., Ng, S. H., Li, K. H. H., & Yoon, Y.-J. (2015) · Lab on a Chip · doi:10.1039/c5lc00685f · Cited by 704
Multi-tissue interactions in an integrated three-tissue organ-on-a-chip platform
Skardal, A., Murphy, S. V., Devarasetty, M., Mead, I., Kang, H.-W., Seol, Y.-J., Shrike Zhang, Y., Shin, S.-R., Zhao, L., Aleman, J., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-08879-x · Cited by 623
Organoid-on-a-chip and body-on-a-chip systems for drug screening and disease modeling
Skardal, A., Shupe, T., & Atala, A. (2016) · Drug Discovery Today · doi:10.1016/j.drudis.2016.07.003 · Cited by 512
“There is a considerable need for more accurate human-representative systems to model the effects of drug candidate compounds on the body [1,2].”
Background
Metadata
- Authors
- Sung, J. H., Srinivasan, B., Esch, M. B., McLamb, W. T., Bernabini, C., Shuler, M. L., & Hickman, J. J.
- Venue
- Experimental Biology and Medicine
- Publisher
- Frontiers Media SA
- Published
- 2014-06-20
- Volume
- 239
- Issue
- 9
- Pages
- 1225-1239
- ISSN
- 0071-3384 (ISSN-L)
- 1535-3702
- 1535-3699
- OpenAlex
- W2125828967
- Cited by
- 132
- References
- 18
- FWCI
- 8.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.