Using physiologically-based pharmacokinetic-guided “body-on-a-chip” systems to predict mammalian response to drug and chemical exposure
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
The continued development of in vitro systems that accurately emulate human response to drugs or chemical agents will impact drug development, our understanding of chemical toxicity, and enhance our ability to respond to threats from chemical or biological agents. A promising technology is to build microscale replicas of humans that capture essential elements of physiology, pharmacology, and/or toxicology (microphysiological systems). Here, we review progress on systems for microscale models of mammalian systems that include two or more integrated cellular components. These systems are described as a “body-on-a-chip”, and utilize the concept of physiologically-based pharmacokinetic (PBPK) modeling in the design. These microscale systems can also be used as model systems to predict whole-body responses to drugs as well as study the mechanism of action of drugs using PBPK analysis. In this review, we provide examples of various approaches to construct such systems with a focus on their physiological usefulness and various approaches to measure responses (e.g. chemical, electrical, or mechanical force and cellular viability and morphology). While the goal is to predict human response, other mammalian cell types can be utilized with the same principle to predict animal response. These systems will be evaluated on their potential to be physiologically accurate, to provide effective and efficient platform for analytics with accessibility to a wide range of users, for ease of incorporation of analytics, functional for weeks to months, and the ability to replicate previously observed human responses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250 · cited 3×
“During the past 1–5 years, many systems have been developed with the aim of reproducing specific organ functions, such as the blood vessels (37, 38), liver (39, 40), gastrointestinal tract (41, 42), blood-brain-barrier (43–45), lung (46, 47), kidney (48–50) and heart (51, 52).”
Physiological Parameters in Laboratory Animals and Humans
Davies, B., & Morris, T. (1993) · Pharmaceutical Research · doi:10.1023/a:1018943613122 · Cited by 2,926
The blood-brain barrier/neurovascular unit in health and disease
Hawkins, B. T., & Davis, T. P. (2005) · Pharmacological Reviews · doi:10.1124/pr.57.2.4 · Cited by 2,661 · cited 1×
“Disruption of the barrier tissue integrity leads to increases in permeability and loss of barrier functionality, and it is associated with the development and progression of several diseases, such as gastrointestinal autoimmune diseases or neuroinflammatory diseases (98, 99).”
Pericytes are required for blood–brain barrier integrity during embryogenesis
Daneman, R., Zhou, L., Kebede, A. A., & Barres, B. A. (2010) · Nature · doi:10.1038/nature09513 · Cited by 2,128 · cited 1×
“TEER measurements are traditionally performed using commercially available systems, normally consisting of a pair of Ag/AgCl electrodes, to record the low frequency resistance of confluent cell monolayers grown on porous membranes (100, 101).”
Microscale culture of human liver cells for drug development
Khetani, S. R., & Bhatia, S. N. (2008) · Nature Biotechnology · doi:10.1038/nbt1361 · Cited by 1,219 · cited 2×
“During the past 1–5 years, many systems have been developed with the aim of reproducing specific organ functions, such as the blood vessels (37, 38), liver (39, 40), gastrointestinal tract (41, 42), blood-brain-barrier (43–45), lung (46, 47), kidney (48–50) and heart (51, 52).”
A Human Disease Model of Drug Toxicity–Induced Pulmonary Edema in a Lung-on-a-Chip Microdevice
Huh, D., Leslie, D. C., Matthews, B. D., Fraser, J. P., Jurek, S., Hamilton, G. A., Thorneloe, K. S., McAlexander, M. A., & Ingber, D. E. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004249 · Cited by 993 · cited 1×
“This device was further used to reproduce drug-induced pulmonary edema.(57) Natarajan et al.”
In vitro microvessels for the study of angiogenesis and thrombosis
Zheng, Y., Chen, J., Craven, M., Choi, N. W., Totorica, S., Diaz-Santana, A., Kermani, P., Hempstead, B., Fischbach-Teschl, C., López, J. A., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1201240109 · Cited by 894
Pharmacokinetics and pharmacodynamics of systemically administered glucocorticoids.
Czock, D., Keller, F., Rasche, F. M., & H??ussler, U. (2005) · Clinical Pharmacokinetics · doi:10.2165/00003088-200544010-00003 · Cited by 886 · cited 1×
“A two-compartment model can be used to describe the distribution time of such drugs (10).”
Engineering of functional, perfusable 3D microvascular networks on a chip
Kim, S., Lee, H., Chung, M., & Jeon, N. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41320a · Cited by 872 · cited 1×
“During the past 1–5 years, many systems have been developed with the aim of reproducing specific organ functions, such as the blood vessels (37, 38), liver (39, 40), gastrointestinal tract (41, 42), blood-brain-barrier (43–45), lung (46, 47), kidney (48–50) and heart (51, 52).”
Fasano, A., & Shea-Donohue, T. (2005) · Nature Clinical Practice Gastroenterology & Hepatology · doi:10.1038/ncpgasthep0259 · Cited by 484
Cited by
TEER Measurement Techniques for In Vitro Barrier Model Systems
Srinivasan, B., Kolli, A. R., Esch, M. B., Abaci, H. E., Shuler, M. L., & Hickman, J. J. (2015) · SLAS Technology · doi:10.1177/2211068214561025 · Cited by 2,145
Self-citationIn silico toxicology: computational methods for the prediction of chemical toxicity
Raies, A. B., & Bajic, V. B. (2016) · WIREs Computational Molecular Science · doi:10.1002/wcms.1240 · Cited by 744
3D printed microfluidics for biological applications
Ho, C. M. B., Ng, S. H., Li, K. H. H., & Yoon, Y.-J. (2015) · Lab on a Chip · doi:10.1039/c5lc00685f · Cited by 704
Multi-tissue interactions in an integrated three-tissue organ-on-a-chip platform
Skardal, A., Murphy, S. V., Devarasetty, M., Mead, I., Kang, H.-W., Seol, Y.-J., Shrike Zhang, Y., Shin, S.-R., Zhao, L., Aleman, J., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-08879-x · Cited by 623
Organoid-on-a-chip and body-on-a-chip systems for drug screening and disease modeling
Skardal, A., Shupe, T., & Atala, A. (2016) · Drug Discovery Today · doi:10.1016/j.drudis.2016.07.003 · Cited by 512
“There is a considerable need for more accurate human-representative systems to model the effects of drug candidate compounds on the body [1,2].”
BackgroundOrgan-on-a-chip devices advance to market
Zhang, B., & Radisic, M. (2017) · Lab on a Chip · doi:10.1039/c6lc01554a · Cited by 437
Organ/body-on-a-chip based on microfluidic technology for drug discovery
Kimura, H., Sakai, Y., & Fujii, T. (2018) · Drug Metabolism and Pharmacokinetics · doi:10.1016/j.dmpk.2017.11.003 · Cited by 435
Robotic fluidic coupling and interrogation of multiple vascularized organ chips
Novak, R., Ingram, M., Marquez, S., Das, D., Delahanty, A., Herland, A., Maoz, B. M., Jeanty, S. S. F., Somayaji, M. R., Burt, M., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0497-x · Cited by 427
Microfluidics: reframing biological enquiry
Duncombe, T. A., Tentori, A. M., & Herr, A. E. (2015) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm4041 · Cited by 345
Organ-on-a chip systems: microengineering to biomimic living systems
Zheng, F., Fu, F., Cheng, Y., Wang, C., Zhao, Y., & Gu, Z. (2016) · Small · doi:10.1002/smll.201503208 · Cited by 338
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Drug compound screening in single and integrated multi-organoid body-on-a-chip systems
Skardal, A., Aleman, J., Forsythe, S., Rajan, S., Murphy, S., Devarasetty, M., Pourhabibi Zarandi, N., Nzou, G., Wicks, R., Sadri-Ardekani, H., et al. (2020) · Biofabrication · doi:10.1088/1758-5090/ab6d36 · Cited by 270
The relevance and potential roles of microphysiological systems in biology and medicine
Wikswo, J. P. (2014) · Experimental Biology and Medicine · doi:10.1177/1535370214542068 · Cited by 248
Design and demonstration of a pumpless 14 compartment microphysiological system
Miller, P. G., & Shuler, M. L. (2016) · Biotechnology and Bioengineering · doi:10.1002/bit.25989 · Cited by 238
Self-citationMicrofluidic Organ‐on‐a‐Chip Technology for Advancement of Drug Development and Toxicology
Caplin, J. D., Granados, N. G., James, M. R., Montazami, R., & Hashemi, N. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500040 · Cited by 205
Rajan, S. A. P., Aleman, J., Wan, M., Pourhabibi Zarandi, N., Nzou, G., Murphy, S., Bishop, C. E., Sadri-Ardekani, H., Shupe, T., Atala, A., et al. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.02.015 · Cited by 201
From cardiac tissue engineering to heart-on-a-chip: beating challenges
Zhang, Y. S., Aleman, J., Arneri, A., Bersini, S., Piraino, F., Shin, S. R., Dokmeci, M. R., & Khademhosseini, A. (2015) · Biomedical Materials · doi:10.1088/1748-6041/10/3/034006 · Cited by 189
Satoh, T., Sugiura, S., Shin, K., Onuki-Nagasaki, R., Ishida, S., Kikuchi, K., Kakiki, M., & Kanamori, T. (2018) · Lab on a Chip · doi:10.1039/c7lc00952f · Cited by 181
Prantil-Baun, R., Novak, R., Das, D., Somayaji, M. R., Przekwas, A., & Ingber, D. E. (2018) · Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev-pharmtox-010716-104748 · Cited by 176
Animal tissue culture principles and applications
Verma, A., Verma, M., & Singh, A. (2020) · Animal Biotechnology · doi:10.1016/b978-0-12-811710-1.00012-4 · Cited by 161
Cancer-on-a-chip systems at the frontier of nanomedicine
Zhang, Y. S., Zhang, Y.-N., & Zhang, W. (2017) · Drug Discovery Today · doi:10.1016/j.drudis.2017.03.011 · Cited by 127
Progress, obstacles, and limitations in the use of stem cells in organ-on-a-chip models
Wnorowski, A., Yang, H., & Wu, J. C. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.06.001 · Cited by 124
Human biomimetic liver microphysiology systems in drug development and precision medicine
Gough, A., Soto-Gutierrez, A., Vernetti, L., Ebrahimkhani, M. R., Stern, A. M., & Taylor, D. L. (2021) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/s41575-020-00386-1 · Cited by 117
Self-contained, low-cost Body-on-a-Chip systems for drug development
Wang, Y. I., Oleaga, C., Long, C. J., Esch, M. B., McAleer, C. W., Miller, P. G., Hickman, J. J., & Shuler, M. L. (2017) · Experimental Biology and Medicine · doi:10.1177/1535370217694101 · Cited by 59
“chemical environment surrounding the cells.(2,18) Customized surface composition of cell culture substrates that favors the anchorage of specific cell adhesion molecules prevents phenotype loss and improves specific cellular functions.”
BackgroundMethodSelf-citationArakawa, H., Sugiura, S., Kawanishi, T., Shin, K., Toyoda, H., Satoh, T., Sakai, Y., Kanamori, T., & Kato, Y. (2020) · Lab on a Chip · doi:10.1039/c9lc00884e · Cited by 48
Novelli, G., Spitalieri, P., Murdocca, M., Centanini, E., & Sangiuolo, F. (2023) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2022.1059579 · Cited by 43
“Moreover, a higher level of complexity is pursued by the Sung group, pioneer in this field, that aim to combine different organoids and organoids-on-a-chip in order to get even closer to the reproduction of the human body, also called “human-on-a-chip”, with the purpose of developing a comprehensive model that could a…”
BackgroundCritical Considerations for the Design of Multi-Organ Microphysiological Systems (MPS)
Malik, M., Yang, Y., Fathi, P., Mahler, G. J., & Esch, M. B. (2021) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2021.721338 · Cited by 43
“For more complex systems with more organ mimics, PBPK models are used as a guide to construct MPS (Sung et al., 2014, 2019).”
MethodSelf-citationYou-on-a-chip’ for precision medicine
Low, L. A., & Tagle, D. A. (2018) · Expert Review of Precision Medicine and Drug Development · doi:10.1080/23808993.2018.1456333 · Cited by 18
Metadata
- Authors
- Sung, J. H., Srinivasan, B., Esch, M. B., McLamb, W. T., Bernabini, C., Shuler, M. L., & Hickman, J. J.
- Venue
- Experimental Biology and Medicine
- Publisher
- Frontiers Media SA
- Published
- 2014-06-20
- Volume
- 239
- Issue
- 9
- Pages
- 1225-1239
- ISSN
- 0071-3384 (ISSN-L)
- 1535-3702
- 1535-3699
- OpenAlex
- W2125828967
- Cited by
- 132
- References
- 18
- FWCI
- 8.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.