Consensus Report: The Current Role of Self-Monitoring of Blood Glucose in Non-Insulin-Treated Type 2 Diabetes
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
The Coalition for Clinical Research—Self-Monitoring of Blood Glucose Scientific Board convened a meeting in San Francisco, CA, July 20–21, 2011, to discuss the current practice of self-monitoring of blood glucose (SMBG) in non-insulin-treated (NIT) type 2 diabetes mellitus (T2DM). Twelve physician panel members from academia, practice, and government attended this meeting. These experts came from the United States, Brazil, Canada, France, Germany, Italy, and the United Kingdom. In addition, three consultants from Australia, Germany, and the United States contributed to the group's final report. This coalition was organized by Diabetes Technology Society. Self-monitoring of blood glucose was studied from eight perspectives related to patients with NIT T2DM: (1) epidemiological studies; (2) randomized controlled trials (RCT)s and meta-analyses; (3) targets, timing, and frequency of SMBG use; (4) incidence and role of SMBG in preventing hypoglycemia with single-drug regimens and combination regimens consisting of antihyperglycemic agents other than secretagogues and insulin; (5) comparison of SMBG with continuous glucose monitoring; (6) technological capabilities and limitations of SMBG; (7) barriers to appropriate use of SMBG; and (8) methods and end points for appropriate future clinical trials. The panel emphasized recent studies, which reflect the current approach for applying this intervention. Among the participants there was consensus that: SMBG is an established practice for patients with NIT T2DM, and to be most effective, it should be performed in a structured format where information obtained from this measurement is used to guide treatment; New, high-quality efficacy data from RCTs have demonstrated efficacy of SMBG in NIT T2DM in trials reported since 2008; Both patients and health care professionals require education on how to respond to the data for SMBG to be effective; and Additional well-defined studies are needed to assess the benefits and costs of SMBG with end points not limited to hemoglobin A1c.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nathan, D. M., Buse, J. B., Davidson, M. B., Ferrannini, E., Holman, R. R., Sherwin, R., & Zinman, B. (2009) · Diabetes Care · doi:10.2337/dc08-9025 · Cited by 3,834
Standards of medical care in diabetes—2011
American Diabetes Association (2011) · Diabetes Care · doi:10.2337/dc11-s011 · Cited by 2,880
Buse, J. B., Rosenstock, J., Sesti, G., Schmidt, W. E., Montanya, E., Brett, J. H., Zychma, M., & Blonde, L. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60659-0 · Cited by 1,503
Self-citationMonnier, L., Lapinski, H., & Colette, C. (2003) · Diabetes Care · doi:10.2337/diacare.26.3.881 · Cited by 1,461
Bech, P., Olsen, L. R., Kjoller, M., & Rasmussen, N. K. (2003) · International Journal of Methods in Psychiatric Research · doi:10.1002/mpr.145 · Cited by 1,015
Rodbard, H. W., Jellinger, P. S., Davidson, J. A., Einhorn, D., Garber, A. J., Grunberger, G., Handelsman, Y., Horton, E. S., Lebovitz, H., Levy, P., et al. (2009) · Endocrine Practice · doi:10.4158/ep.15.6.540 · Cited by 942
Zinman, B., Gerich, J., Buse, J. B., Lewin, A., Schwartz, S., Raskin, P., Hale, P. M., Zdravkovic, M., Blonde, L., & the LEAD-4 Study Investigators (2009) · Diabetes Care · doi:10.2337/dc08-2124 · Cited by 848
Self-citationQuinn, C. C., Shardell, M. D., Terrin, M. L., Barr, E. A., Ballew, S. H., & Gruber-Baldini, A. L. (2011) · Diabetes Care · doi:10.2337/dc11-0366 · Cited by 650
Bennett, W. L., Maruthur, N. M., Singh, S., Segal, J. B., Wilson, L. M., Chatterjee, R., Marinopoulos, S. S., Puhan, M. A., Ranasinghe, P., Block, L., et al. (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-154-9-201105030-00336 · Cited by 609
Pickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541
Rosenstock, J., Brazg, R., Andryuk, P. J., Lu, K., & Stein, P. (2006) · Clinical Therapeutics · doi:10.1016/j.clinthera.2006.10.007 · Cited by 514
Handelsman, Y., Mechanick, J. I., Blonde, L., Grunberger, G., Bloomgarden, Z. T., Bray, G. A., Dagogo-Jack, S., Davidson, J. A., Einhorn, D., Ganda, O., et al. (2011) · Endocrine Practice · doi:10.4158/ep.17.s2.1 · Cited by 513
Self-citationGlycemic Variability: A Hemoglobin A1c–Independent Risk Factor for Diabetic Complications
Brownlee, M., & Hirsch, I. B. (2006) · JAMA · doi:10.1001/jama.295.14.1707 · Cited by 482
Polonsky, W. H., Fisher, L., Schikman, C. H., Hinnen, D. A., Parkin, C. G., Jelsovsky, Z., Petersen, B., Schweitzer, M., & Wagner, R. S. (2011) · Diabetes Care · doi:10.2337/dc10-1732 · Cited by 429
Self-citationFarmer, A., Wade, A., Goyder, E., Yudkin, P., French, D., Craven, A., Holman, R., Kinmonth, A.-L., & Neil, A. (2007) · BMJ · doi:10.1136/bmj.39247.447431.be · Cited by 407
Glucose Meters: A Review of Technical Challenges to Obtaining Accurate Results
Tonyushkina, K., & Nichols, J. H. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300446 · Cited by 406
Factors affecting blood glucose monitoring: sources of errors in measurement
Ginsberg, B. H. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300438 · Cited by 348
Psychometric properties of the hypoglycemia fear survey-ii for adults with type 1 diabetes
Gonder-Frederick, L. A., Schmidt, K. M., Vajda, K. A., Greear, M. L., Singh, H., Shepard, J. A., & Cox, D. J. (2011) · Diabetes Care · doi:10.2337/dc10-1343 · Cited by 337
Ziemer, D. C., Kolm, P., Weintraub, W. S., Vaccarino, V., Rhee, M. K., Twombly, J. G., Narayan, K. M. V., Koch, D. D., & Phillips, L. S. (2010) · Annals of Internal Medicine · doi:10.7326/0003-4819-152-12-201006150-00004 · Cited by 326
O’Kane, M. J., Bunting, B., Copeland, M., & Coates, V. E. (2008) · BMJ · doi:10.1136/bmj.39534.571644.be · Cited by 326
Vigersky, R. A., Fonda, S. J., Chellappa, M., Walker, M. S., & Ehrhardt, N. M. (2012) · Diabetes Care · doi:10.2337/dc11-1438 · Cited by 301
Self-citationCharpentier, G., Benhamou, P.-Y., Dardari, D., Clergeot, A., Franc, S., Schaepelynck-Belicar, P., Catargi, B., Melki, V., Chaillous, L., Farret, A., et al. (2011) · Diabetes Care · doi:10.2337/dc10-1259 · Cited by 292
Self-citationMartin, S., Schneider, B., Heinemann, L., Lodwig, V., Kurth, H.-J., Kolb, H., Scherbaum, W. A., & for the ROSSO Study Group (2006) · Diabetologia · doi:10.1007/s00125-005-0083-5 · Cited by 284
Self-citationSelf-monitoring of blood glucose in type 2 diabetes: systematic review
Clar, C., Barnard, K., Cummins, E., Royle, P., & Waugh, N. (2010) · Health Technology Assessment · doi:10.3310/hta14120 · Cited by 274
Asynchronous and synchronous teleconsultation for diabetes care: A systematic literature review
Verhoeven, F., Tanja-Dijkstra, K., Nijland, N., Eysenbach, G., & van Gemert-Pijnen, L. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400323 · Cited by 247
Ehrhardt, N. M., Chellappa, M., Walker, M. S., Fonda, S. J., & Vigersky, R. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500320 · Cited by 199
Self-citationPostprandial Hyperglycemia and Glycemic Variability
Standl, E., Schnell, O., & Ceriello, A. (2011) · Diabetes Care · doi:10.2337/dc11-s206 · Cited by 183
Self-citationLongitudinal study of new and prevalent use of self-monitoring of blood glucose
Karter, A. J., Parker, M. M., Moffet, H. H., Spence, M. M., Chan, J., Ettner, S. L., & Selby, J. V. (2006) · Diabetes Care · doi:10.2337/dc06-2073 · Cited by 139
Franciosi, M., Lucisano, G., Pellegrini, F., Cantarello, A., Consoli, A., Cucco, L., Ghidelli, R., Sartore, G., Sciangula, L., Nicolucci, A., et al. (2011) · Diabetic Medicine · doi:10.1111/j.1464-5491.2011.03268.x · Cited by 137
Self-citationPrediction of Severe Hypoglycemia
Cox, D. J., Gonder-Frederick, L., Ritterband, L., Clarke, W., & Kovatchev, B. P. (2007) · Diabetes Care · doi:10.2337/dc06-1386 · Cited by 129
Poolsup, N., Suksomboon, N., & Rattanasookchit, S. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0091 · Cited by 127
Gerich, J., Raskin, P., Jean-Louis, L., Purkayastha, D., & Baron, M. A. (2005) · Diabetes Care · doi:10.2337/diacare.28.9.2093 · Cited by 116
Efficacy and Safety of Acarbose in Metformin-Treated Patients With Type 2 Diabetes
Rosenstock, J., Brown, A., Fischer, J., Jain, A., Littlejohn, T., Nadeau, D., Sussman, A., Taylor, T., Krol, A., & Magner, J. (1998) · Diabetes Care · doi:10.2337/diacare.21.12.2050 · Cited by 93
Polonsky, W. H., Fisher, L., Schikman, C. H., Hinnen, D. A., Parkin, C. G., Jelsovsky, Z., Axel-Schweitzer, M., Petersen, B., & Wagner, R. S. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0073 · Cited by 85
Self-citationConsensus Report of the Coalition for Clinical Research—Self-Monitoring of Blood Glucose
Klonoff, D. C., Bergenstal, R., Blonde, L., Boren, S. A., Church, T. S., Gaffaney, J., Jovanovič, L., Kendall, D. M., Kollman, C., Kovatchev, B. P., et al. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200612 · Cited by 74
Self-citationDo Race and Ethnicity Impact Hemoglobin A1c Independent of Glycemia?
Herman, W. H. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300406 · Cited by 56
Schnell, O., Alawi, H., Battelino, T., Ceriello, A., Diem, P., Felton, A., Grzeszczak, W., Harno, K., Kempler, P., Satman, I., et al. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0028 · Cited by 47
Self-citationPerera, N. J., Stewart, P. M., Williams, P. F., Chua, E. L., Yue, D. K., & Twigg, S. M. (2011) · Diabetic Medicine · doi:10.1111/j.1464-5491.2011.03362.x · Cited by 33
Research works printed but not linked: 74
- 10.1186/1756-0500-3-318 · DOI
- 10.1111/j.1742-1241.2009.02271.x · DOI
- Kleefstra N, 2010, Neth J Med., 68, 311
- 10.1007/s00125-006-0581-0 · DOI
- 10.1080/02813430701267413 · DOI · Paper page
- 10.1111/j.1464-5491.2011.03258.x · DOI
- 10.1089/dia.2008.0001 · DOI · Paper page
- Towfigh A, 2008, Am J Manag Care, 14, 468
- 10.1016/j.jdiacomp.2009.01.002 · DOI
- 10.1111/j.1753-0407.2010.00081.x · DOI · Paper page
- 10.1177/193229681000400601 · DOI
- 10.1093/bja/aer120 · DOI
- 10.2337/db09-1774 · DOI · Paper page
- 10.1111/j.1463-1326.2007.00839.x · DOI · Paper page
- 10.2337/dc10-0159 · DOI · Paper page
- 10.1186/1472-6823-10-7 · DOI · Paper page
- 10.1111/j.1463-1326.2009.01075.x · DOI · Paper page
- 10.1111/j.1464-5491.2006.01800.x · DOI · Paper page
- 10.7326/0003-4819-121-12-199412150-00004 · DOI · Paper page
- 10.2337/dc09-2009 · DOI · Paper page
- 10.1001/archinte.168.18.1975 · DOI · Paper page
- 10.1111/j.1464-5491.2011.03301.x · DOI · Paper page
- 10.1089/dia.2010.0233 · DOI
- 10.1111/j.1463-1326.2007.00820.x · DOI · Paper page
- 10.1111/j.1365-2753.2009.01280.x · DOI · Paper page
- 10.1016/S0140-6736(10)60590-9 · DOI · Paper page
- 10.1111/j.1463-1326.2010.01251.x · DOI · Paper page
- Jayaram S, 2010, J Assoc Physicians India., 58, 679
- 10.1016/j.jdiacomp.2011.06.004 · DOI
- 10.1016/j.clinthera.2007.01.003 · DOI · Paper page
- 10.4239/wjd.v1.i5.153 · DOI
- 10.1111/j.1463-1326.2006.00704.x · DOI · Paper page
- 10.1111/j.1742-1241.2010.02353.x · DOI · Paper page
- 10.1016/S0002-9343(01)00713-6 · DOI · Paper page
- 10.2165/00002512-200421040-00004 · DOI
- 10.1111/j.1464-5491.2009.02666.x · DOI · Paper page
- 10.1111/j.1463-1326.2007.00744.x · DOI · Paper page
- 10.2165/00044011-200323100-00007 · DOI
- 10.1371/journal.pone.0003087 · DOI · Paper page
- 10.1089/dia.2009.0043 · DOI · Paper page
- 10.1177/193229681100500408 · DOI
- Vigersky RA, Diabetes Care.
- 10.1016/j.cca.2009.03.022 · DOI · Paper page
- 10.1177/193229681000400110 · DOI · Paper page
- 10.2337/dc06-1679 · DOI · Paper page
- 10.1177/193229681000400501 · DOI · Paper page
- Bamberg R, 2005, Clin Lab Sci., 18, 203
- 10.2337/dc06-1679 · DOI · Paper page
- 10.1089/dia.2010.0076 · DOI · Paper page
- 10.1177/193229681000400301 · DOI · Paper page
- 10.1177/193229681100500229 · DOI
- 10.1177/0145721711410718 · DOI
- 10.1177/193229681000400524 · doi:10.1177/193229681000400524
- 10.1177/0145721708329700 · doi:10.1177/0145721708329700
- 10.1089/dia.2008.0111 · DOI · Paper page
- 10.1177/193229680900300619 · DOI · Paper page
- 10.2165/11594270-000000000-00000 · DOI
- 10.1111/j.1742-1241.2009.02277.x · DOI · Paper page
- 10.1186/1472-6963-3-6 · DOI · Paper page
- 10.1016/j.bcp.2010.06.005 · DOI
- 10.1177/193229681100500112 · DOI
- 10.2337/dc10-1661 · DOI · Paper page
- 10.2337/dc11-s216 · DOI · Paper page
- 10.1111/j.1753-0407.2009.00009.x · DOI · Paper page
- 10.1016/j.diabres.2009.12.013 · DOI
- 10.1177/193229680900300408 · DOI
- 10.1177/193229681100500538 · DOI
- 10.1177/193229681100500539 · doi:10.1177/193229681100500539
- 10.1007/s11892-009-0084-8 · DOI
- 10.1016/j.jbi.2010.05.006 · DOI
- 10.1371/journal.pone.0019256 · DOI · Paper page
- 10.2337/diacare.28.3.626 · DOI · Paper page
- 10.1111/j.1524-4733.2009.00571.x · DOI
- Bradley C, 1994, Handbook of psychology and diabetes: A guide to psychological measurement in diabetes research and practice, 111
Cited by
Clinical Practice Guidelines for Multiple Endocrine Neoplasia Type 1 (MEN1)
Thakker, R. V., Newey, P. J., Walls, G. V., Bilezikian, J., Dralle, H., Ebeling, P. R., Melmed, S., Sakurai, A., Tonelli, F., & Brandi, M. L. (2012) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-1230 · Cited by 1,477
Francis, G. L., Waguespack, S. G., Bauer, A. J., Angelos, P., Benvenga, S., Cerutti, J. M., Dinauer, C. A., Hamilton, J., Hay, I. D., Luster, M., et al. (2015) · Thyroid · doi:10.1089/thy.2014.0460 · Cited by 1,238
Garber, A. J., Abrahamson, M. J., Barzilay, J. I., Blonde, L., Bloomgarden, Z. T., Bush, M. A., Dagogo-Jack, S., Davidson, M. B., Einhorn, D., Garvey, W. T., et al. (2013) · Endocrine Practice · doi:10.4158/ep13176.csuppl · Cited by 220
Self-citationGreenwood, D. A., Blozis, S. A., Young, H. M., Nesbitt, T. S., & Quinn, C. C. (2015) · Journal of Medical Internet Research · doi:10.2196/jmir.4112 · Cited by 128
Interferences and Limitations in Blood Glucose Self-Testing: An Overview of the Current Knowledge
Erbach, M., Freckmann, G., Hinzmann, R., Kulzer, B., Ziegler, R., Heinemann, L., & Schnell, O. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816641433 · Cited by 115
“Inappropriate handling of SMBG has been identified as the most common factor affecting BG results; more than 90% of overall inaccuracies result from incorrect use of BG meters.(4,18) Due to the minute blood samples utilized by mod-”
BackgroundInfluentialSelf-citation
Metadata
- Authors
- Klonoff, D. C., Blonde, L., Cembrowski, G., Chacra, A. R., Charpentier, G., Colagiuri, S., Dailey, G., Gabbay, R. A., Heinemann, L., Kerr, D., Nicolucci, A., Polonsky, W., Schnell, O., Vigersky, R., & Yale, J.-F.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2011-11
- Volume
- 5
- Issue
- 6
- Pages
- 1529-1548
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2110750999
- Cited by
- 97
- References
- 38
- FWCI
- 8.47
- Type
- journal article
- Language
- en
- Open access
- bronze
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.