Analytical Performance Requirements for Systems for Self-Monitoring of Blood Glucose With Focus on System Accuracy: Relevant Differences Among ISO 15197:2003, ISO 15197:2013, and Current FDA Recommendations

Open access

The DOI matches its Crossref record, with a small difference in title or year; 35 of the 35 references it cites were found in a registry or an index.

Abstract

In the European Union (EU), the ISO (International Organization for Standardization) 15197 standard is applicable for the evaluation of systems for self-monitoring of blood glucose (SMBG) before the market approval. In 2013, a revised version of this standard was published. Relevant revisions in the analytical performance requirements are the inclusion of the evaluation of influence quantities, for example, hematocrit, and some changes in the testing procedures for measurement precision and system accuracy evaluation, for example, number of test strip lots. Regarding system accuracy evaluation, the most important change is the inclusion of more stringent accuracy criteria. In 2014, the Food and Drug Administration (FDA) in the United States published their own guidance document for the premarket evaluation of SMBG systems with even more stringent system accuracy criteria than stipulated by ISO 15197:2013. The establishment of strict accuracy criteria applicable for the premarket evaluation is a possible approach to further improve the measurement quality of SMBG systems. However, the system accuracy testing procedure is quite complex, and some critical aspects, for example, systematic measurement difference between the reference measurement procedure and a higher-order procedure, may potentially limit the apparent accuracy of a given system. Therefore, the implementation of a harmonized reference measurement procedure for which traceability to standards of higher order is verified through an unbroken, documented chain of calibrations is desirable. In addition, the establishment of regular and standardized post-marketing evaluations of distributed test strip lots should be considered as an approach toward an improved measurement quality of available SMBG systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/1932296815580160

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 4

  1. 10. Richtlinie 98/79/EG Des Europäischen Parlaments Und Des Rates Vom 27. October 1998. Über In-Vitro-Diagnostika. 1998 [Google Scholar]
  2. 15. Freckmann G, Baumstark A, Zschornack E, et al. Evaluation of the system accuracy of 34 blood glucose monitoring systems according to EN ISO 15197. Poster presented at: ADA; June 8-12, 2012; Philadelphia, PA. [Google Scholar]
  3. 32. Freckmann G, Link M, Baumstark A, Schmid C, Pleus S, Haug C. System accuracy evaluation of 10 SMBG systems with 3 lots each following ISO 15197:2013 against 2 different comparison methods. Paper presented at: EASD; September 15-19, 2014; Vienna, Austria. [Google Scholar]
  4. 33. American Diabetes Association. Self-monitoring of blood glucose. Diabetes Care. 1996;19(suppl 1):S62-S66. [Google Scholar]

Cited by

See all 74

Metadata

Authors
Freckmann, G., Schmid, C., Baumstark, A., Rutschmann, M., Haug, C., & Heinemann, L.
Affiliations
  • Institut für Diabetes-Technologie (Germany) (DE)
  • Edingen-Neckarhausen, Germany
  • Profil Institute for Metabolic Research (DE)
Venue
Journal of Diabetes Science and Technology
Published
2015-04-14
Volume
9
Issue
4
Pages
885-894
ISSN
1932-2968 (ISSN-L)
OpenAlex
W2001788756
Cited by
70
References
35
Citations by year
2026: 6 · 2025: 7 · 2024: 6 · 2023: 8 · 2022: 7 · 2021: 7 · 2020: 5 · 2019: 5 · 2018: 10 · 2017: 4 · 2016: 4 · 2015: 1
FWCI
0.96
Type
journal article
Language
en
Open access
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • Journal of Diabetes Science and Technology (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
Universität Ulm
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
Keywords
self-monitoring of blood glucose, system accuracy, ISO 15197, FDA guidance, measurement precision, influence quantities, hematocrit, reference measurement procedure, traceability, calibration chain, post-marketing evaluation, measurement quality
MeSH terms
Blood Glucose, Diabetes Mellitus, Europe, Hematocrit, Humans, Hypoglycemia, United States, United States Food and Drug Administration, Blood Glucose Self-Monitoring, Reproducibility of Results, Guidelines as Topic

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.