Interferences and Limitations in Blood Glucose Self-Testing: An Overview of the Current Knowledge
Open accessThe DOI matches its Crossref record, with a small difference in title or year; 65 of the 65 references it cites were found in a registry or an index.
Abstract
In general, patients with diabetes performing self-monitoring of blood glucose (SMBG) can strongly rely on the accuracy of measurement results. However, various factors such as application errors, extreme environmental conditions, extreme hematocrit values, or medication interferences may potentially falsify blood glucose readings. Incorrect blood glucose readings may lead to treatment errors, for example, incorrect insulin dosing. Therefore, the diabetes team as well as the patients should be well informed about limitations in blood glucose testing. The aim of this publication is to review the current knowledge on limitations and interferences in blood glucose testing with the perspective of their clinical relevance.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Newer blood glucose monitors tend to use a different reagent (glucose dehydrogenase, with or without a cofactor, rather than glucose oxidase). This reduces the susceptibility to interference from haematocrit, the partial pressure of oxygen, and most drugs (aside from icodextrin, a non–glucose-containing peritoneal dialysate).13”
From Blood glucose monitoring devices: current considerations (2023) · cites this paper as [13]
In the citing paper
“Numerous interfering factors have been reported to influence the results of blood glucose meters (135,136).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [135]
Citations
Cites
International Diabetes Federation 2017
Carracher, A. M., Marathe, P. H., & Close, K. L. (2018) · Journal of Diabetes · doi:10.1111/1753-0407.12644 · Cited by 13,418
International Organization for Standardization
(2011) · SpringerReference · doi:10.1007/springerreference_16847 · Cited by 12,534
Standards of Medical Care in Diabetes
Power, D. (2006) · Diabetes Care · doi:10.2337/diacare.29.02.06.dc05-1593 · Cited by 8,673
Cosentino, F., Grant, P. J., Aboyans, V., Bailey, C. J., Ceriello, A., Delgado, V., Federici, M., Filippatos, G., Grobbee, D. E., Hansen, T. B., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz486 · Cited by 4,763
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht108 · Cited by 1,955
(2014) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2013.10.013 · Cited by 609
Standards of Medical Care in Diabetes—2016: Summary of Revisions
(2016) · Diabetes Care · doi:10.2337/dc16-s003 · Cited by 448
Polonsky, W. H., Fisher, L., Schikman, C. H., Hinnen, D. A., Parkin, C. G., Jelsovsky, Z., Petersen, B., Schweitzer, M., & Wagner, R. S. (2011) · Diabetes Care · doi:10.2337/dc10-1732 · Cited by 429
Glucose Meters: A Review of Technical Challenges to Obtaining Accurate Results
Tonyushkina, K., & Nichols, J. H. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300446 · Cited by 406 · cited 5×
“Inappropriate handling of SMBG has been identified as the most common factor affecting BG results; more than 90% of overall inaccuracies result from incorrect use of BG meters.(4,18) Due to the minute blood samples utilized by mod-”
BackgroundInfluentialFactors affecting blood glucose monitoring: sources of errors in measurement
Ginsberg, B. H. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300438 · Cited by 348 · cited 7×
“As a consequence, high levels of triglycerides may result in falsely low BG readings.(23) In BG systems utilizing GO-based test strips, the potential interference of pO 2 has been reported.”
BackgroundInfluential
Research works printed but not linked: 3
- Downie P., 2013, Diabetes Primary Care, 15, 149
- Mortazavi S, 2014, J Biomed Phys Eng, 4, 111
- King DA, 2010, Isr Med Assoc J, 12, 314
Cited by
From pre-diabetes to diabetes: diagnosis, treatments and translational research
Khan, R., Chua, Z., Tan, J., Yang, Y., Liao, Z., & Zhao, Y. (2019) · Medicina · doi:10.3390/medicina55090546 · Cited by 484
“[117] However, what cannot be avoided during the patient’s self-monitoring of blood glucose (SMBC) is the need for finger pricking.”
BackgroundSacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Diabetes Care · doi:10.2337/dci23-0036 · Cited by 351
Glycemic Monitoring and Management in Advanced Chronic Kidney Disease
Galindo, R. J., Beck, R. W., Scioscia, M. F., Umpierrez, G. E., & Tuttle, K. R. (2020) · Endocrine Reviews · doi:10.1210/endrev/bnaa017 · Cited by 202
Sacks, D. B., Arnold, M. A., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvad080 · Cited by 208
Lorestani, F., Zhang, X., Abdullah, A. M., Xin, X., Liu, Y., Rahman, M. M., Biswas, M. A. S., Li, B., Dutta, A., Niu, Z., et al. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202306117 · Cited by 132
Aleppo, G., Laffel, L. M., Ahmann, A. J., Hirsch, I. B., Kruger, D. F., Peters, A., Weinstock, R. S., & Harris, D. R. (2017) · Journal of the Endocrine Society · doi:10.1210/js.2017-00388 · Cited by 123
“There are no indications that environmental factors, such as extreme temperature, altitude, or humidity, impact rtCGM accuracy, but they do affect fingerstick blood glucose monitoring [28].”
BackgroundTaylor, P. J., Thompson, C. H., & Brinkworth, G. D. (2018) · Journal of Diabetes Investigation · doi:10.1111/jdi.12807 · Cited by 105
Approach to Using Trend Arrows in the FreeStyle Libre Flash Glucose Monitoring Systems in Adults
Kudva, Y. C., Ahmann, A. J., Bergenstal, R. M., Gavin, J. R., Kruger, D. F., Midyett, L. K., Miller, E., & Harris, D. R. (2018) · Journal of the Endocrine Society · doi:10.1210/js.2018-00294 · Cited by 97
“There are no indications that environmental factors, such as extreme temperature, altitude, or humidity, impact CGM accuracy, but they do affect fingerstick monitoring values [34].”
BackgroundLorenz, C., Sandoval, W., & Mortellaro, M. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0028 · Cited by 80
“…with CGM systems that use electrochemical-and enzymatic-(i.e., glucose oxidase and glucose dehydrogenase) based methods to measure glucose concentrations, 9,11,12,15,23–25 the Eversense CGM sensor uses an abiotic (non–enzyme based), fluorescent glucose-indicating polymer to measure glucose 26 (Fig.”
Laffel, L. M., Aleppo, G., Buckingham, B. A., Forlenza, G. P., Rasbach, L. E., Tsalikian, E., Weinzimer, S. A., & Harris, D. R. (2017) · Journal of the Endocrine Society · doi:10.1210/js.2017-00389 · Cited by 79
“There are no indications that environmental factors, such as temperature, altitude, or humidity impact rtCGM accuracy, but they do affect fingerstick blood glucose monitoring results [45].”
BackgroundAtchison, C. J., Pristerà, P., Cooper, E., Papageorgiou, V., Redd, R., Piggin, M., Flower, B., Fontana, G., Satkunarajah, S., Ashrafian, H., et al. (2020) · Clinical Infectious Diseases · doi:10.1093/cid/ciaa1178 · Cited by 77
“There are many advantages in terms of uptake, cost, patient activation, and scale [4, 6], but also potential disadvantages in relation to validity, usability, and practicality, which should be explored [6, 7].”
Monitoring of Pediatric Type 1 Diabetes
Marks, B. E., & Wolfsdorf, J. I. (2020) · Frontiers in Endocrinology · doi:10.3389/fendo.2020.00128 · Cited by 72
Effects of a modestly lower carbohydrate diet in gestational diabetes: a randomized controlled trial
Mijatovic, J., Louie, J. C. Y., Buso, M. E., Atkinson, F. S., Ross, G. P., Markovic, T. P., & Brand-Miller, J. C. (2020) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/nqaa137 · Cited by 47
A Review of Safety and Hazards Associated With the Artificial Pancreas
Ramkissoon, C. M., Aufderheide, B., Bequette, B. W., & Vehí, J. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2749038 · Cited by 47
Assessment of glycemia in chronic kidney disease
Hassanein, M., & Shafi, T. (2022) · BMC Medicine · doi:10.1186/s12916-022-02316-1 · Cited by 49
Osuna, V., Aparicio-Martínez, E. P., Dominguez, R. B., & Vega‐Ríos, A. (2024) · Chemosensors · doi:10.3390/chemosensors12080159 · Cited by 32
Metal-organic frameworks (MOFs)-based hybrid structures in developing glucose sensors
Sharifabad, A. H., Safavi‐Mirmahalleh, S., Golshan, M., Sienkiewicz, M., Saeb, M. R., & Salami‐Kalajahi, M. (2025) · Chemical Engineering Journal · doi:10.1016/j.cej.2025.161513 · Cited by 38
Röhling, M., Martin, T., Wonnemann, M., Kragl, M., Klein, H. H., Heinemann, L., Martin, S., & Kempf, K. (2019) · Nutrients · doi:10.3390/nu11102305 · Cited by 32
“, user error on test accuracy, the need for multiple fingerstick blood samples each day, and the limited data available (only a single snap shot of glucose concentrations and not trending data) [14,15]), and has been evaluated in patients without [16] and with type 1 or type 2 diabetes [7,17].”
BackgroundSelf-citationNonadjunctive Use of Continuous Glucose Monitors for Insulin Dosing: Is It Safe?
Shapiro, A. R. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816688303 · Cited by 22
“When comparing CGMs with SMBG readings, it is often noted that SMBG readings can be subject to error due to inadequate user cleansing of the fingerstick site,(7) as well as a variety of other circumstances.(8) Currently, these SMBG readings are used to calibrate CGMs, creating additional sources of potential CGM inacc…”
The Evolution of Diabetes Technology – Options Toward Personalized Care
Zahid, M., Dowlatshahi, S., Kansara, A., & Sadhu, A. (2023) · Endocrine Practice · doi:10.1016/j.eprac.2023.04.007 · Cited by 24
Glucose: Archetypal Biomarker in Diabetes Diagnosis, Clinical Management and Research
Krentz, A. J., & Hompesch, M. (2016) · Biomarkers in Medicine · doi:10.2217/bmm-2016-0170 · Cited by 26
Bietenbeck, A., Geilenkeuser, W. J., Klawonn, F., Spannagl, M., Nauck, M., Petersmann, A., Thaler, M., Winter, C., & Luppa, P. B. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-1142 · Cited by 22
Mohan, V., Joshi, S., Mithal, A., Kesavadev, J., Unnikrishnan, A., Saboo, B., Kumar, P. R. G., Chawla, M. S., Bhograj, A., & KOVIL, R. R. (2023) · Diabetes Therapy · doi:10.1007/s13300-022-01355-4 · Cited by 31
Wang, H.-C., Chang, F., Tsai, T.-M., Chen, C.-H., & Chen, Y. (2020) · Biomedical Optics Express · doi:10.1364/boe.389638 · Cited by 19
MacLeod, K., Katz, L. B., & Cameron, H. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818790228 · Cited by 20
Ghane, N., Broadney, M. M., Davis, E. K., Trenschel, R. W., Collins, S. M., Brady, S. M., & Yanovski, J. A. (2019) · Pediatric Diabetes · doi:10.1111/pedi.12910 · Cited by 21
Strengthening Diabetes Care in Humanitarian Crises in Low- and Middle-income Settings
Kehlenbrink, S., Ansbro, É., Besançon, S., Hassan, S., Roberts, B., & Jobanputra, K. (2022) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgac331 · Cited by 19
Challenges in diagnosing and monitoring diabetes in patients with chronic liver diseases
Silva, T. E., Ronsoni, M. F., & Schiavon, L. D. L. (2017) · Diabetes & Metabolic Syndrome Clinical Research & Reviews · doi:10.1016/j.dsx.2017.12.013 · Cited by 17
Howell, A. P., Parrett, J. L., & Malcom, D. R. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819889638 · Cited by 15
“Intravenous vitamin C has also shown POC interference, particularly associated with falsely elevated POC blood glucose measurements.(14,18,19) POC glucose inaccuracies are documented specifically in burn patients receiving high dose intravenous vitamin C infusions.”
BackgroundWearable smart sensors integration with AI and machine learning for tracking human health
Xianyong, S., Mishra, D. K., Özcan, Ö. Ö., Karahan, M., Panpan, T., Zhongshan, X., & Kumar, P. V. (2025) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2025.100711 · Cited by 31
Wang, Y., Plebani, M., Sciacovelli, L., Zhang, S., Wang, Q., & Zhou, R. (2020) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.23327 · Cited by 16
Ridder, F. D., Braspenning, R., Ordóñez, J., Klarenbeek, G., Lauwers, P., Ledeganck, K. J., Delbeke, D., & Block, C. E. M. D. (2024) · PLoS ONE · doi:10.1371/journal.pone.0301041 · Cited by 13
Pfützner, A., Demircik, F., Kirsch, V., Pfützner, J. W., Strobl, S., Hanna, M., Spatz, J., & Pfützner, A. H. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819841353 · Cited by 11
Practical Guidance on Basal Insulin Initiation and Titration in Asia: A Delphi-Based Consensus
Chan, S. P., Aamir, A. H., Bee, Y. M., Deerochanawong, C., Paz-Pacheco, E. T., Tiu, F., Foo, S. H., Tan, K. E. K., Le, T. Q., Saraswati, M. R., et al. (2022) · Diabetes Therapy · doi:10.1007/s13300-022-01286-0 · Cited by 14
“mended to be implemented in a structured approach [23].”
BackgroundMethodBlood glucose monitoring devices: current considerations
Sly, B., & Taylor, J. (2023) · Australian Prescriber · doi:10.18773/austprescr.2023.013 · Cited by 11
N-Acetylcysteine interference with a glucose dehydrogenase linked glucose meter
Lyon, M. E., & Lyon, A. W. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/1932296821999416 · Cited by 10
“Determination of Partial Regression Coefficients by Linear Regression Models by Ordinary Least Squares for Equations (1) to (3).”
BackgroundMethodInfluentialGamarra, E., Careddu, G., Fazi, A., Turra, V., Morelli, A., Camponovo, C., & Trimboli, P. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0126 · Cited by 11
Mansouri, D., Khayat, E., Khayat, M., Aboawja, M., ASEERI, A., Banah, F., Alsiary, K., Rammal, L., Almalki, A. D., & Hasaballah, M. I. (2020) · Diabetes Metabolic Syndrome and Obesity · doi:10.2147/dmso.s234675 · Cited by 10
Weng, C.-W., Cheng, T., Chen, R. L. C., & Hsieh, B. (2017) · International Journal of Electrochemical Science · doi:10.20964/2017.06.87 · Cited by 9
Update on Patient Self-Testing with Portable and Wearable Devices: Advantages and Limitations
Lippi, G., Pighi, L., & Mattiuzzi, C. (2024) · Diagnostics · doi:10.3390/diagnostics14182037 · Cited by 11
“Altitude differences, especially high altitudes, reduce oxygen levels and thus alter the readings of sensors that utilize some enzymatic reactions [43,44].”
BackgroundKim, D.-S., Sobhan, A., Oh, J., Lee, J. H., Park, C., & Lee, J. (2024) · Biosensors · doi:10.3390/bios14120630 · Cited by 8
Demircik, F., Kirsch, V., Ramljak, S., Vogg, M., Pfützner, A. H., & Pfützner, A. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819841357 · Cited by 9
Kuznowicz, M., Jędrzak, A., & Jesionowski, T. (2023) · Molecules · doi:10.3390/molecules28217281 · Cited by 10
“The low influence of interfering agents is important in the case of medical or environmental research, where many other compounds can be found in addition to the tested compound, which can significantly affect the final measurements [15,16].”
BackgroundMartens, T. W., Beck, R. W., Griffen, C., Di, J., Elkind-Hirsch, K. E., Johnson, M. L., Castle, J. R., Beck, S. E., & Bergenstal, R. M. (2025) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2025-005469 · Cited by 10
Weissenbacher, S., Yang, C., Kuan, T.-C., Demircik, F., Hanna, M., & Pfützner, A. (2019) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2019.1662300 · Cited by 7
Romans, C. W., Day, T. K., & Smith, J. J. (2020) · Journal of Veterinary Emergency and Critical Care · doi:10.1111/vec.12958 · Cited by 7
Phillips, S., Setford, S. J., Grady, M., Liu, Z., & Cameron, H. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211042352 · Cited by 7
Grady, M., Cameron, H., Phillips, S., Smith, G., & Setford, S. J. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819873053 · Cited by 7
Mader, J. K., Baumstark, A., Tüting, J., Sokol, G., Schuebel, R., Tong, Y., Roetschke, J., & Slingerland, R. J. (2024) · Diabetes Therapy · doi:10.1007/s13300-024-01665-9 · Cited by 8
Janfaza, S., Shanmugam, N. R., Jolly, P., Prashanthi, K., Singh, U., MacKay, S., Wishart, D. S., & Ingber, D. E. (2024) · Nanomaterials · doi:10.3390/nano14090796 · Cited by 6
“However, several factors, such as deteriorated test strips, reader’s imprecision, improper storage, interference from multiple medications, and environmental conditions, may impact the reliability of these blood glucose measurements [9–12].”
BackgroundMatthes, A., Bleidorn, J., & Markwart, R. (2022) · Zeitschrift für Evidenz Fortbildung und Qualität im Gesundheitswesen · doi:10.1016/j.zefq.2022.06.002 · Cited by 11
Design and Analysis of a Photonic Crystal Nanocavity Biosensor for Glucose Measurement
Kumar, S., & Sen, M. (2025) · Brazilian Journal of Physics · doi:10.1007/s13538-025-01919-2 · Cited by 10
Glucose Monitoring Techniques and Their Calibration
Yadav, D., Singh, S. P., & Dubey, P. K. (2023) · Springer eBooks · doi:10.1007/978-981-19-1550-5_99-1 · Cited by 8
Knowledge and Practice of Glucose Self-Monitoring Devices among Patients with Diabetes
Mohamed, S., Mukhtar, M., Aseed, K., Osman, D. N., Dawelbait, M., Saeed, A. M., Ahmed, N., Fadul, N., & Idriss, R. (2023) · Sudan Journal of Medical Sciences · doi:10.18502/sjms.v18i2.13598 · Cited by 5
“Blood sugar values must be carefully interpreted as part of said education, sincemaking wrong judgmentsmight arise from inappropriately considering grossly atypical results [11].”
BackgroundCommon but Missed Errors in Blood Glucose Monitoring
Sreelakshmi, R., Ashok, A. D., Unes, Y., & Basanth, A. (2023) · International Journal of Diabetes and Technology · doi:10.4103/ijdt.ijdt_15_24 · Cited by 6
Inman, M., Lyon, A. W., Lyon, O. A. S., & Lyon, M. E. (2020) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2020-0101-ra · Cited by 6
Caswell, M., Brown, D., Frank, J., Wallace, J. F., & Pardo, S. A. (2020) · Current Medical Research and Opinion · doi:10.1080/03007995.2020.1734919 · Cited by 5
Scherer, T., Metz, M., Beghini, M., Bilban, M., Gensthaler, L., Luca, A. C., Kaplanian, M., Eid, S. A., Koldyka, O., Hackl, M. T., et al. (2025) · Science Advances · doi:10.1126/sciadv.adt7366 · Cited by 5
Dallera, G., Alaa, A., El-Osta, A. A. R., Kreindler, J., & Harris, M. J. (2022) · BMJ Open · doi:10.1136/bmjopen-2022-063838 · Cited by 5
Pardo, S. A., Dunne, N., & Simmons, D. A. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817713025 · Cited by 4
“While large errors may result in clinically relevant differences in insulin dosing, even small measurement errors may combine to a substantial total effect due to factors that include human error, meter accuracy, test strip error, environmental and physiological conditions, and concomitant medication.(9,15) Potential…”
BackgroundTsou, C.-S., Liou, C., Cheng, L., & Zhou, H. (2022) · Cogent Engineering · doi:10.1080/23311916.2022.2083475 · Cited by 6
“It is unreasonable to assume that all test strips in use will provide identical or similar measurement results, even they are produced by a same manufacturer (Erbach et al., 2016).”
BackgroundEvaluating the Utilization of a Perioperative Hyperglycemic Protocol: A Quality Improvement Project
Robinson, A., Pham, N. M., Burke, E. J., Long, C., Teschel, D. E., & Aroke, E. N. (2022) · Journal of PeriAnesthesia Nursing · doi:10.1016/j.jopan.2022.09.009 · Cited by 5
Adapting blood glucose meter biosensors for the measurement of lactose in dairy ingredients
Wagner, C. E., Amamcharla, J. K., Rao, A., & Metzger, L. E. (2020) · Journal of Dairy Science · doi:10.3168/jds.2019-17903 · Cited by 5
INTERFERENCE STUDY OF GLUCOSE LEVEL MEASUREMENTS USING GLUCOMETERS BASED ON GLUCOSE OXIDASE
GRECU, A.-G., COSTACHE, G., Sandu, N., Matache, M. L., & Matache, M. (2024) · Revue Roumaine de Chimie · doi:10.33224/rrch.2024.69.10-12.10 · Cited by 3
Vloemans, D., Hileghem, L. V., Ordutowski, H., Dosso, F. D., Spasić, D., & Lammertyn, J. (2024) · Methods in molecular biology · doi:10.1007/978-1-0716-3850-7_1 · Cited by 4
Clair, S. S., Ulyatt, C. M., Corkin, M. T., Lord, L. G., Crowther, C. A., Harding, J. E., & Lin, L. (2024) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2024.114438 · Cited by 7
Kongdee, R., Parsia, B., Thabit, H., & Harper, S. (2025) · Digital Health · doi:10.1177/20552076251332580 · Cited by 7
Erroneous Causes of Point-of-Care Glucose Readings
Majewski, J., Risler, Z. W., & Gupta, K. (2023) · Cureus · doi:10.7759/cureus.36356 · Cited by 5
“These high levels of uric acid can oxidize the electrode and falsely cause hyperglycemic readings [2].”
BackgroundInfluentialIuliano, S., Greco, E. A., Mirabelli, M., CHIEFARI, E. D., Caroleo, P., Puccio, L., Giuliano, S., FOTI, D. P., Brunetti, A., & Aversa, A. (2022) · Minerva Endocrinology · doi:10.23736/s2724-6507.22.03691-0 · Cited by 3
Schweiger, D. Š., & Battelino, T. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-816714-4.00001-6 · Cited by 3
Bakal, V., Gusliakova, О. I., Kartashova, A., Saveleva, М. S., Анатольевна, Д. П., Kozhevnikov, I. O., Ryabov, E. A., Bratashov, D. N., & Сергеевна, П. Е. (2025) · Sensors · doi:10.3390/s25134143 · Cited by 2
“While these devices offer portability and rapid results, they require frequent blood sampling and are susceptible to interference from hematocrit levels, oxygen tension, and other blood components [13].”
Setford, S. J. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251377019 · Cited by 2
Diabetes and metabolic disorders: Early identification and monitoring strategies
Goyat, J., Tiwari, B. K., & Sharma, R. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-33263-0.00001-2 · Cited by 2
Determination of lactose in milk and milk-derived ingredients using biosensor-based techniques
Wagner, C. E., Singh, R., & Amamcharla, J. K. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-96010-6.00017-5 · Cited by 2
Glucometer versus analyzer: comparable results with negligible clinical risk
Gümüş, A., Coşkun, C., Uçar, K. T., Erdin, İ., Tek, S., Evran, B., Çat, A., & Zengi, O. (2025) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2025.2456917 · Cited by 3
Kongdee, R., Parsia, B., Thabit, H., & Harper, S. (2025) · Therapeutic Advances in Endocrinology and Metabolism · doi:10.1177/20420188251362089 · Cited by 2
“6 Studies have shown that people with T1DM face challenges in understanding and making appropriate treatment decisions, based on their glucose monitoring system, as it is overwhelming and difficult to review.”
Mills, K., & Roetschke, J. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211050370 · Cited by 2
Lin, S., Lin, W.-Y., Chang, J.-T., & Chu, C.-F. (2017) · PLoS ONE · doi:10.1371/journal.pone.0180617 · Cited by 3
Chundawat, S. P. S. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.05.21.106468 · Cited by 2
Kim, D. S., Sobhan, A., Oh, J., & Lee, J. (2024) · Preprints.org · doi:10.20944/preprints202405.0519.v1 · Cited by 2
Pseudohyperglycemia due to glucometer interference in galactosemia
Decru, B., Blanckaert, H., Naulaers, G., Vanhole, C., Rymen, D., Witters, P., Wambeke, I. V., Gillard, P., & Vermeersch, P. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-1304 · Cited by 1
Baumstark, A., Pleus, S., Mende, J., Jendrike, N. R. M., Tesar, M., Schauer, S., Sugiyama, T., Aoki, T., Sugiura, M., Freckmann, G., et al. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241231294 · Cited by 2
Self-citationNanomaterial-based Approaches for Non-invasive Diabetes Management: The Future of Glycaemic Control
Baishya, D., Deka, H., Hoque, N., Bhairam, M., & Choudhury, A. (2025) · Drug Delivery Letters · doi:10.2174/0122103031324954250324182308 · Cited by 1
Varga, B., Nemes-Nagy, E., Mikes-Jakab, B., & Kórodi, M. (2025) · Revista română de medicină de laborator · doi:10.2478/rrlm-2025-0020 · Cited by 1
Scoping review of subcutaneous glucose monitoring techniques
Hrubá, E., Kubíček, J., & Augustýnek, M. (2025) · Measurement · doi:10.1016/j.measurement.2025.119940 · Cited by 1
Jemai, C., Htira, Y., Salem, A., Ali, Z. H., Lajili, O., Hedfi, I., Amara, S. B., & Mami, F. B. (2026) · Nutrition and Metabolic Insights · doi:10.1177/11786388251408962 · Cited by 2
Kobos, E., Kostrzewa-Zabłocka, E., Ławnik, A. J., & Hornik, B. (2026) · Scientific Reports · doi:10.1038/s41598-026-42065-2 · Cited by 1
“Other authors indicated that the result of the measurement might be influenced by repeated squeezing of blood drops, and diluting the collected blood drop with foreign fluid at the test site was associated with pseudohypoglycemia 26,44,45 .”
Patra, S., Sahu, K. M., & Swain, S. K. (2026) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2026.151286 · Cited by 1
Ateko, R. O., Decker, A., Nyarko, E. N. Y., Kumahor, E. K., Thomford, N. E., Adjei, A. B., Kumi, J., Adadey, S. M., Atiase, Y., & Asare‐Anane, H. (2026) · Diabetology & Metabolic Syndrome · doi:10.1186/s13098-026-02213-0 · Cited by 1
“However, OGTT is time-consuming, sensitive to recent diet, physical activity, illness, and medication use, and may be poorly tolerated due to gastrointestinal side effects [28, 34, 62].”
Young, A. C., Hollowbread, A., & Wayman, M. (2018) · Practical Diabetes · doi:10.1002/pdi.2199 · Cited by 1
Tebaibia, A., Malek, R., Griene, L., Haddam, A. E. M., Nouri, N., Cherrak, A., Belkacem, K., Abrouk, S., Semrouni, M., Gasmi, K., et al. (2023) · Médecine des Maladies Métaboliques · doi:10.1016/j.mmm.2023.04.002 · Cited by 1
Commercialized Enzymatic Biosensors in Healthcare Against the Conventional Methods
Satyaprasad, A. U. (2023) · Springer eBooks · doi:10.1007/978-981-15-6982-1_14 · Cited by 2
Nanomaterials-Modified Electrodes for Glucose Sensing
Urgunde, A. B. (2024) · Nanostructure science and technology · doi:10.1007/978-3-031-67176-0_11 · Cited by 1
Kuboi, T., Sugino, M., Sadamura, T., Kawaguchi, N., Tadatomo, Y., Takada, K., Okamoto, N., Miyamoto, K., Nakano, A., Miura, N., et al. (2025) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/00045632251326460 · Cited by 1
“3,4 When such interference is suspected, a con fi rmatory test is performed using a blood gas analyser, which is the most common method used to screen for neonatal hypoglycemia.”
Marquant, M., Gessler, S., Diechtierow, M., Gerber, J., & Oeztuerk, Z. A. N. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251319344 · Cited by 2
Glucose Monitoring Techniques and Their Calibration
Yadav, D., Singh, S. P., & Dubey, P. K. (2023) · Springer eBooks · doi:10.1007/978-981-99-2074-7_99 · Cited by 1
An Approach to Pseudohyperglycemia in Point-of-Care-Testing Glucose Monitoring
Saparamadu, A. A. D. N. S., Lam, C. W., & Lee, J. (2018) · Point of Care The Journal of Near-Patient Testing & Technology · doi:10.1097/poc.0000000000000171
Pardo, S. A., Dunne, N., & Simmons, D. A. (2019) · Therapeutic Delivery · doi:10.4155/tde-2019-0047
Needle Optimization for Wrist-Based Electronic Mosquito Pilot Human Testing
Teixeira, J., Wilkes, R., Yadid-Pecht, O., & Mintchev, M. P. (2019) · IEEE International Conference on Bioinformatics and Bioengineering (BIBE) · doi:10.1109/bibe.2019.00094
“These include the following four: (a) lack of autonomicity; (b) invasive blood sampling; (c) indiscrete equipment and patient alienation; and (d) inaccurate glucose readings [4, 5, 6].”
Paradigmenwechsel in der Glukosekontrolle: Urin-, Blut-, interstitielle Glukosemessung
Forst, T. M. (2022) · Diabetologie und Stoffwechsel · doi:10.1055/a-1225-8678
Metadata
- Authors
- Erbach, M., Freckmann, G., Hinzmann, R., Kulzer, B., Ziegler, R., Heinemann, L., & Schnell, O.
- Affiliations
- Sciarc Institute, Baierbrunn, Germany
- Institut für Diabetes-Technologie (Germany) (DE)
- Roche Diabetes Care GmbH (Germany) (DE)
- Forschungsinstitut der Diabetes Akademie Mergentheim (DE)
- Diabetes Clinic for Children and Adolescents, Muenster, Germany
- Science & Co GmbH, Düsseldorf, Germany
- Forschergruppe Diabetes e.V., Munich-Neuherberg, Germany
- Corresponding author
- Schnell, Oliver
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2016-07-09
- Volume
- 10
- Issue
- 5
- Pages
- 1161-1168
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC5032951
- OpenAlex
- W2340313604
- Cited by
- 115
- References
- 65
- Citations by year
- 2026: 12 · 2025: 18 · 2024: 16 · 2023: 18 · 2022: 9 · 2021: 3 · 2020: 13 · 2019: 10 · 2018: 7 · 2017: 8 · 2016: 1
- FWCI
- 1.28
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- self-monitoring of blood glucose, blood glucose monitoring, measurement interference, diabetes mellitus, insulin dosing errors, hematocrit, environmental factors, patient education, treatment errors
- MeSH terms
- Blood Glucose, Diabetes Mellitus, Female, Humans, Male, Blood Glucose Self-Monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.