The Simoa HD-1 Analyzer: A Novel Fully Automated Digital Immunoassay Analyzer with Single-Molecule Sensitivity and Multiplexing
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Disease detection at the molecular level is driving the emerging revolution of early diagnosis and treatment. A challenge facing the field is that protein biomarkers for early diagnosis can be present in very low abundance. The lower limit of detection with conventional immunoassay technology is the upper femtomolar range (10(-13) M). Digital immunoassay technology has improved detection sensitivity three logs, to the attomolar range (10(-16) M). This capability has the potential to open new advances in diagnostics and therapeutics, but such technologies have been relegated to manual procedures that are not well suited for efficient routine use. We describe a new laboratory instrument that provides full automation of single-molecule array (Simoa) technology for digital immunoassays. The instrument is capable of single-molecule sensitivity and multiplexing with short turnaround times and a throughput of 66 samples/h. Singleplex and multiplexed digital immunoassays were developed for 16 proteins of interest in cardiovascular, cancer, infectious disease, neurology, and inflammation research. The average sensitivity improvement of the Simoa immunoassays versus conventional ELISA was >1200-fold, with coefficients of variation of <10%. The potential of digital immunoassays to advance human diagnostics was illustrated in two clinical areas: traumatic brain injury and early detection of infectious disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanoparticle-Based Bio-Bar Codes for the Ultrasensitive Detection of Proteins
Nam, J.-M., Thaxton, C. S., & Mirkin, C. A. (2003) · Science · doi:10.1126/science.1088755 · Cited by 2,390
Rissin, D. M., Kan, C. W., Campbell, T. G., Howes, S. C., Fournier, D. R., Song, L., Piech, T., Patel, P. P., Chang, L., Rivnak, A. J., et al. (2010) · Nature Biotechnology · doi:10.1038/nbt.1641 · Cited by 2,119 · cited 4×
“The ultrahigh sensitivity enabled by Simoa digital immunoassays has been discussed previously.(22) In brief, the enzyme–substrate reaction in analog immunoassays is conducted in relatively large reaction volumes (50–100 μL) that dilute product molecules during the signal generation step.”
BackgroundMethodSelf-citationNanoparticle-Based Bio-Barcodes for the Ultrasensitive Detection of Proteins*
Nam, J.-M., Thaxton, C. S., & Mirkin, C. A. (2020) · Spherical Nucleic Acids · doi:10.1201/9781003056713-94 · Cited by 2,035
Protein biomarker discovery and validation: the long and uncertain path to clinical utility
Rifai, N., Gillette, M. A., & Carr, S. A. (2006) · Nature Biotechnology · doi:10.1038/nbt1235 · Cited by 1,867
Plasmonic ELISA for the ultrasensitive detection of disease biomarkers with the naked eye
de la Rica, R., & Stevens, M. M. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.186 · Cited by 873
Grubisha, D. S., Lipert, R. J., Park, H.-Y., Driskell, J., & Porter, M. D. (2003) · Analytical Chemistry · doi:10.1021/ac034356f · Cited by 779
The Clinical Plasma Proteome: A Survey of Clinical Assays for Proteins in Plasma and Serum
Anderson, N. L. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.126706 · Cited by 562
Thaxton, C. S., Elghanian, R., Thomas, A. D., Stoeva, S. I., Lee, J.-S., Smith, N. D., Schaeffer, A. J., Klocker, H., Horninger, W., Bartsch, G., et al. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0904719106 · Cited by 388
Drucker, E., & Krapfenbauer, K. (2013) · EPMA Journal · doi:10.1186/1878-5085-4-7 · Cited by 349
Ultrasensitive Flow-based Immunoassays Using Single-Molecule Counting
Todd, J., Freese, B., Lu, A., Held, D., Morey, J., Livingston, R., & Goix, P. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2007.091181 · Cited by 289
Cited by
Aspergillus fumigatus and Aspergillosis in 2019
Latgé, J.-P., & Chamilos, G. (2019) · Clinical Microbiology Reviews · doi:10.1128/cmr.00140-18 · Cited by 1,400
Nolan, J. P., Sandroni, C., Böttiger, B. W., Cariou, A., Cronberg, T., Friberg, H., Genbrugge, C., Haywood, K., Lilja, G., Moulaert, V. R. M., et al. (2021) · Intensive Care Medicine · doi:10.1007/s00134-021-06368-4 · Cited by 1,078
Nolan, J. P., Soar, J., Cariou, A., Cronberg, T., Moulaert, V. R. M., Deakin, C. D., Bottiger, B. W., Friberg, H., Sunde, K., & Sandroni, C. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-4051-3 · Cited by 943
Tumor-Derived Exosomes and Their Role in Cancer Progression
(2016) · Advances in Clinical Chemistry · doi:10.1016/bs.acc.2015.12.005 · Cited by 755
Kuhle, J., Barro, C., Andreasson, U., Derfuss, T., Lindberg, R., Sandelius, Å., Liman, V., Norgren, N., Blennow, K., & Zetterberg, H. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-1195 · Cited by 740
Nolan, J. P., Sandroni, C., Böttiger, B. W., Cariou, A., Cronberg, T., Friberg, H., Genbrugge, C., Haywood, K., Lilja, G., Moulaert, V. R. M., et al. (2021) · Resuscitation · doi:10.1016/j.resuscitation.2021.02.012 · Cited by 707
Ultrasensitive and Highly Specific Lateral Flow Assays for Point-of-Care Diagnosis
Liu, Y., Zhan, L., Qin, Z., Sackrison, J., & Bischof, J. C. (2021) · ACS Nano · doi:10.1021/acsnano.0c10035 · Cited by 626
Neurofilaments as biomarkers in neurological disorders — towards clinical application
Khalil, M., Teunissen, C. E., Lehmann, S., Otto, M., Piehl, F., Ziemssen, T., Bittner, S., Sormani, M. P., Gattringer, T., Abu-Rumeileh, S., et al. (2024) · Nature Reviews Neurology · doi:10.1038/s41582-024-00955-x · Cited by 446
Detection of interferon alpha protein reveals differential levels and cellular sources in disease
Rodero, M. P., Decalf, J., Bondet, V., Hunt, D., Rice, G. I., Werneke, S., McGlasson, S. L., Alyanakian, M.-A., Bader-Meunier, B., Barnerias, C., et al. (2017) · Journal of Experimental Medicine · doi:10.1084/jem.20161451 · Cited by 375
Self-citationType I interferon in rheumatic diseases
Muskardin, T. L. W., & Niewold, T. B. (2018) · Nature Reviews Rheumatology · doi:10.1038/nrrheum.2018.31 · Cited by 308
Blood neurofilament light: a critical review of its application to neurologic disease
Barro, C., Chitnis, T., & Weiner, H. L. (2020) · Annals of Clinical and Translational Neurology · doi:10.1002/acn3.51234 · Cited by 296
Neurofilament light chain in serum for the diagnosis of amyotrophic lateral sclerosis
Verde, F., Steinacker, P., Weishaupt, J. H., Kassubek, J., Oeckl, P., Halbgebauer, S., Tumani, H., von Arnim, C. A. F., Dorst, J., Feneberg, E., et al. (2019) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp-2018-318704 · Cited by 272
Serum Neurofilament Light Chain for Prognosis of Outcome After Cardiac Arrest
Moseby-Knappe, M., Mattsson, N., Nielsen, N., Zetterberg, H., Blennow, K., Dankiewicz, J., Dragancea, I., Friberg, H., Lilja, G., Insel, P. S., et al. (2019) · JAMA Neurology · doi:10.1001/jamaneurol.2018.3223 · Cited by 264
Cohen, L., Cui, N., Cai, Y., Garden, P. M., Li, X., Weitz, D. A., & Walt, D. R. (2020) · ACS Nano · doi:10.1021/acsnano.0c02378 · Cited by 263
Verberk, I. M. W., Thijssen, E., Koelewijn, J., Mauroo, K., Vanbrabant, J., de Wilde, A., Zwan, M. D., Verfaillie, S. C. J., Ossenkoppele, R., Barkhof, F., et al. (2020) · Alzheimer's Research & Therapy · doi:10.1186/s13195-020-00682-7 · Cited by 258
Rapid SARS-CoV-2 Detection Using Electrochemical Immunosensor
Mojsoska, B., Larsen, S., Olsen, D. A., Madsen, J. S., Brandslund, I., & Alatraktchi, F. A. (2021) · Sensors · doi:10.3390/s21020390 · Cited by 206
Monitoring wastewater for assessing community health: Sewage Chemical-Information Mining (SCIM)
Daughton, C. G. (2018) · Science of The Total Environment · doi:10.1016/j.scitotenv.2017.11.102 · Cited by 178
Hoiland, R. L., Fergusson, N. A., Mitra, A. R., Griesdale, D. E. G., Devine, D. V., Stukas, S., Cooper, J., Thiara, S., Foster, D., Chen, L. Y. C., et al. (2020) · Blood Advances · doi:10.1182/bloodadvances.2020002623 · Cited by 170
An Update on Blood-Based Markers of Alzheimer’s Disease Using the SiMoA Platform
Li, D., & Mielke, M. M. (2019) · Neurology and Therapy · doi:10.1007/s40120-019-00164-5 · Cited by 147
Blood Neurofilament Light Chain: The Neurologist’s Troponin?
Thebault, S., Booth, R. A., & Freedman, M. S. (2020) · Biomedicines · doi:10.3390/biomedicines8110523 · Cited by 101
Anti-tau antibody administration increases plasma tau in transgenic mice and patients with tauopathy
Yanamandra, K., Patel, T. K., Jiang, H., Schindler, S., Ulrich, J. D., Boxer, A. L., Miller, B. L., Kerwin, D. R., Gallardo, G., Stewart, F., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aal2029 · Cited by 100
Wojdała, A. L., Bellomo, G., Gaetani, L., Toja, A., Chipi, E., Shan, D., Chiasserini, D., & Parnetti, L. (2023) · Neurobiology of Disease · doi:10.1016/j.nbd.2023.106356 · Cited by 70
“Statistical analysis was performed with the use of the GraphPad Prism software version 9.5.0 (USA) and R software version 4.2.2.”
MethodInfluentialPlasma alpha‐synuclein detected by single molecule array is increased in PD
Ng, A. S. L., Tan, Y. J., Lu, Z., Ng, E. Y. L., Ng, S. Y. E., Chia, N. S. Y., Setiawan, F., Xu, Z., Tay, K. Y., Prakash, K. M., et al. (2019) · Annals of Clinical and Translational Neurology · doi:10.1002/acn3.729 · Cited by 53
“Total alphasynuclein levels were measured using ultrasensitive single molecule array (Simoa) Human Alpha-synuclein assay and Simoa HD-1 Analyzer (Quanterix, MA), according to the manufacturer’s protocol.(10) This assay was developed with two monoclonal antibodies specific to alpha synuclein protein.”
MethodTau and neurofilament light‐chain as fluid biomarkers in spinocerebellar ataxia type 3
Garcia‐Moreno, H., Prudencio, M., Thomas‐Black, G., Solanky, N., Jansen‐West, K. R., Hanna AL‐Shaikh, R., Heslegrave, A., Zetterberg, H., Santana, M. M., Pereira de Almeida, L., et al. (2022) · European Journal of Neurology · doi:10.1111/ene.15373 · Cited by 49
Blood Biomarkers for Alzheimer’s Disease: Much Promise, Cautious Progress
Keshavan, A., Heslegrave, A., Zetterberg, H., & Schott, J. M. (2017) · Molecular Diagnosis & Therapy · doi:10.1007/s40291-016-0241-0 · Cited by 34
Fertan, E., Böken, D., Murray, A., Danial, J. S. H., Lam, J. Y. L., Wu, Y., Goh, P. A., Alić, I., Cheetham, M. R., Lobanova, E., et al. (2024) · Molecular Psychiatry · doi:10.1038/s41380-023-02333-3 · Cited by 31
The relevance of BDNF for neuroprotection and neuroplasticity in multiple sclerosis
Maiworm, M. (2024) · Frontiers in Neurology · doi:10.3389/fneur.2024.1385042 · Cited by 27
Neurofilament light level correlates with brain atrophy, and cognitive and motor performance
Kartau, M., Melkas, S., Kartau, J., Arola, A., Laakso, H., Pitkänen, J., Lempiäinen, J., Koikkalainen, J., Lötjönen, J., Korvenoja, A., et al. (2023) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2022.939155 · Cited by 16
Metadata
- Authors
- Wilson, D. H., Rissin, D. M., Kan, C. W., Fournier, D. R., Piech, T., Campbell, T. G., Meyer, R. E., Fishburn, M. W., Cabrera, C., Patel, P. P., Frew, E., Chen, Y., Chang, L., Ferrell, E. P., von Einem, V., McGuigan, W., Reinhardt, M., Sayer, H., Vielsack, C., & Duffy, D. C.
- Venue
- SLAS Technology
- Publisher
- Elsevier BV
- Published
- 2016-08
- Volume
- 21
- Issue
- 4
- Pages
- 533-547
- ISSN
- 2472-6303 (ISSN-L)
- OpenAlex
- W573909598
- Cited by
- 470
- References
- 29
- FWCI
- 8.36
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.