The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
The Simoa HD-1 Analyzer: A Novel Fully Automated Digital Immunoassay Analyzer with Single-Molecule Sensitivity and Multiplexing
Open accessAbstract
Disease detection at the molecular level is driving the emerging revolution of early diagnosis and treatment. A challenge facing the field is that protein biomarkers for early diagnosis can be present in very low abundance. The lower limit of detection with conventional immunoassay technology is the upper femtomolar range (10(-13) M). Digital immunoassay technology has improved detection sensitivity three logs, to the attomolar range (10(-16) M). This capability has the potential to open new advances in diagnostics and therapeutics, but such technologies have been relegated to manual procedures that are not well suited for efficient routine use. We describe a new laboratory instrument that provides full automation of single-molecule array (Simoa) technology for digital immunoassays. The instrument is capable of single-molecule sensitivity and multiplexing with short turnaround times and a throughput of 66 samples/h. Singleplex and multiplexed digital immunoassays were developed for 16 proteins of interest in cardiovascular, cancer, infectious disease, neurology, and inflammation research. The average sensitivity improvement of the Simoa immunoassays versus conventional ELISA was >1200-fold, with coefficients of variation of <10%. The potential of digital immunoassays to advance human diagnostics was illustrated in two clinical areas: traumatic brain injury and early detection of infectious disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanoparticle-Based Bio-Bar Codes for the Ultrasensitive Detection of Proteins
Nam, J.-M., Thaxton, C. S., & Mirkin, C. A. (2003) · Science · doi:10.1126/science.1088755 · Cited by 2,390
Rissin, D. M., Kan, C. W., Campbell, T. G., Howes, S. C., Fournier, D. R., Song, L., Piech, T., Patel, P. P., Chang, L., Rivnak, A. J., et al. (2010) · Nature Biotechnology · doi:10.1038/nbt.1641 · Cited by 2,119 · cited 4×
“The ultrahigh sensitivity enabled by Simoa digital immunoassays has been discussed previously.(22) In brief, the enzyme–substrate reaction in analog immunoassays is conducted in relatively large reaction volumes (50–100 μL) that dilute product molecules during the signal generation step.”
BackgroundMethodSelf-citationNanoparticle-Based Bio-Barcodes for the Ultrasensitive Detection of Proteins*
Nam, J.-M., Thaxton, C. S., & Mirkin, C. A. (2020) · Spherical Nucleic Acids · doi:10.1201/9781003056713-94 · Cited by 2,035
Protein biomarker discovery and validation: the long and uncertain path to clinical utility
Rifai, N., Gillette, M. A., & Carr, S. A. (2006) · Nature Biotechnology · doi:10.1038/nbt1235 · Cited by 1,867
Plasmonic ELISA for the ultrasensitive detection of disease biomarkers with the naked eye
de la Rica, R., & Stevens, M. M. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.186 · Cited by 873
Grubisha, D. S., Lipert, R. J., Park, H.-Y., Driskell, J., & Porter, M. D. (2003) · Analytical Chemistry · doi:10.1021/ac034356f · Cited by 779
The Clinical Plasma Proteome: A Survey of Clinical Assays for Proteins in Plasma and Serum
Anderson, N. L. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.126706 · Cited by 562
Thaxton, C. S., Elghanian, R., Thomas, A. D., Stoeva, S. I., Lee, J.-S., Smith, N. D., Schaeffer, A. J., Klocker, H., Horninger, W., Bartsch, G., et al. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0904719106 · Cited by 388
Drucker, E., & Krapfenbauer, K. (2013) · EPMA Journal · doi:10.1186/1878-5085-4-7 · Cited by 349
Ultrasensitive Flow-based Immunoassays Using Single-Molecule Counting
Todd, J., Freese, B., Lu, A., Held, D., Morey, J., Livingston, R., & Goix, P. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2007.091181 · Cited by 289
Rissin, D. M., Fournier, D. R., Piech, T., Kan, C. W., Campbell, T. G., Song, L., Chang, L., Rivnak, A. J., Patel, P. P., Provuncher, G. K., et al. (2011) · Analytical Chemistry · doi:10.1021/ac103161b · Cited by 255
Self-citationRandall, J., Mörtberg, E., Provuncher, G. K., Fournier, D. R., Duffy, D. C., Rubertsson, S., Blennow, K., Zetterberg, H., & Wilson, D. H. (2013) · Resuscitation · doi:10.1016/j.resuscitation.2012.07.027 · Cited by 230
Self-citationSingle molecule enzyme-linked immunosorbent assays: Theoretical considerations
Chang, L., Rissin, D. M., Fournier, D. R., Piech, T., Patel, P. P., Wilson, D. H., & Duffy, D. C. (2012) · Journal of Immunological Methods · doi:10.1016/j.jim.2012.02.011 · Cited by 185
Self-citationLiu, R., Liu, X., Tang, Y., Wu, L., Hou, X., & Lv, Y. (2011) · Analytical Chemistry · doi:10.1021/ac103265z · Cited by 160
Multiplexed single molecule immunoassays
Rissin, D. M., Kan, C. W., Song, L., Rivnak, A. J., Fishburn, M. W., Shao, Q., Piech, T., Ferrell, E. P., Meyer, R. E., Campbell, T. G., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50416f · Cited by 159
Self-citationGenomic and proteomic biomarkers for cancer: A multitude of opportunities
Tainsky, M. A. (2009) · Biochimica et Biophysica Acta (BBA) - Reviews on Cancer · doi:10.1016/j.bbcan.2009.04.004 · Cited by 150
Detection of Protein Analytes via Nanoparticle-Based Bio Bar Code Technology
Bao, Y. P., Wei, T.-F., Lefebvre, P., An, H., He, L., Kunkel, G. T., & Müller, U. R. (2006) · Analytical Chemistry · doi:10.1021/ac051798d · Cited by 149
Kan, C. W., Rivnak, A. J., Campbell, T. G., Piech, T., Rissin, D. M., Mösl, M., Peterça, A., Niederberger, H.-P., Minnehan, K. A., Patel, P. P., et al. (2011) · Lab on a Chip · doi:10.1039/c2lc20744c · Cited by 139
Self-citationThe State of the Human Proteome in 2012 as Viewed through PeptideAtlas
Farrah, T., Deutsch, E. W., Hoopmann, M. R., Hallows, J. L., Sun, Z., Huang, C., & Moritz, R. L. (2012) · Journal of Proteome Research · doi:10.1021/pr301012j · Cited by 127
The Citicoline Brain Injury Treatment (COBRIT) Trial: Design and Methods
ZAFONTE, R. D., Friedewald, W. T., Lee, S. M., Levin, B. L., Diaz-Arrastia, R. R., Ansel, B. M., Eisenberg, H. M., Timmons, S. D., Temkin, N. R., Novack, T. A., et al. (2009) · Journal of Neurotrauma · doi:10.1089/neu.2009.1015 · Cited by 94
The New Era of Automated Immunoassay
Bock, J. L. (2000) · American Journal of Clinical Pathology · doi:10.1309/dudm-3y6l-3r1l-qp15 · Cited by 91
Analyte detection with DNA-labeled antibodies and polymerase chain reaction
Joerger, R. D., Truby, T. M. H., Hendrickson, E. R., Young, R. M., & Ebersole, R. C. (1995) · Clinical Chemistry · doi:10.1093/clinchem/41.9.1371 · Cited by 89
Computational prediction of human proteins that can be secreted into the bloodstream
Cui, J., Liu, Q., Puett, D., & Xu, Y. (2008) · Bioinformatics · doi:10.1093/bioinformatics/btn418 · Cited by 64
Genomic biomarkers in predictive medicine. An interim analysis
Simon, R. M. (2011) · EMBO Molecular Medicine · doi:10.1002/emmm.201100153 · Cited by 59
Chang, L., Song, L., Fournier, D. R., Kan, C. W., Patel, P. P., Ferrell, E. P., Pink, B. A., Minnehan, K. A., Hanlon, D., Duffy, D. C., et al. (2012) · Journal of Virological Methods · doi:10.1016/j.jviromet.2012.08.017 · Cited by 53
Self-citationGomez, E., Jespersen, D. J., Harring, J. A., & Binnicker, M. J. (2010) · Clinical and Vaccine Immunology · doi:10.1128/cvi.00086-10 · Cited by 46
Nucleic Acid Detection Immunoassay for Prostate-Specific Antigen Based on Immuno-PCR Methodology
McDermed, J. E., Sanders, R., Fait, S., Klem, R. E., Sarno, M., Adams, T. H., & Diamandis, E. P. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2011.170290 · Cited by 34
Measurement of Single Protein Molecules Using Digital ELISA
Rissin, D. M., Wilson, D. H., & Duffy, D. C. (2013) · Elsevier eBooks · doi:10.1016/b978-0-08-097037-0.00016-6 · Cited by 23
Self-citationThe optics inside an automated single molecule array analyzer
McGuigan, W., Fournier, D. R., Watson, G. W., Walling, L., Gigante, B., Duffy, D. C., Rissin, D. M., Kan, C. W., Meyer, R. E., Piech, T., et al. (2014) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2041706 · Cited by 9
Self-citation
Cited by
Aspergillus fumigatus and Aspergillosis in 2019
Latgé, J.-P., & Chamilos, G. (2019) · Clinical Microbiology Reviews · doi:10.1128/cmr.00140-18 · Cited by 1,400
Nolan, J. P., Sandroni, C., Böttiger, B. W., Cariou, A., Cronberg, T., Friberg, H., Genbrugge, C., Haywood, K., Lilja, G., Moulaert, V. R. M., et al. (2021) · Intensive Care Medicine · doi:10.1007/s00134-021-06368-4 · Cited by 1,078
Nolan, J. P., Soar, J., Cariou, A., Cronberg, T., Moulaert, V. R. M., Deakin, C. D., Bottiger, B. W., Friberg, H., Sunde, K., & Sandroni, C. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-4051-3 · Cited by 943
Tumor-Derived Exosomes and Their Role in Cancer Progression
(2016) · Advances in Clinical Chemistry · doi:10.1016/bs.acc.2015.12.005 · Cited by 755
Kuhle, J., Barro, C., Andreasson, U., Derfuss, T., Lindberg, R., Sandelius, Å., Liman, V., Norgren, N., Blennow, K., & Zetterberg, H. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-1195 · Cited by 740
Metadata
- Authors
- Wilson, D. H., Rissin, D. M., Kan, C. W., Fournier, D. R., Piech, T., Campbell, T. G., Meyer, R. E., Fishburn, M. W., Cabrera, C., Patel, P. P., Frew, E., Chen, Y., Chang, L., Ferrell, E. P., von Einem, V., McGuigan, W., Reinhardt, M., Sayer, H., Vielsack, C., & Duffy, D. C.
- Venue
- SLAS Technology
- Publisher
- Elsevier BV
- Published
- 2016-08
- Volume
- 21
- Issue
- 4
- Pages
- 533-547
- ISSN
- 2472-6303 (ISSN-L)
- OpenAlex
- W573909598
- Cited by
- 470
- References
- 29
- FWCI
- 8.36
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.