Abstract
INTRODUCTION: Tremor is the most common movement disorder, affecting 5.6% of the population with Parkinson's disease or essential tremor over the age of 65. Conventionally, tremor diseases like Parkinson's are treated with medication. An alternative non-invasive symptom treatment is the mechanical suppression of the oscillation movement. The purpose of this review is to identify the weaknesses of past wearable tremor-suppression orthoses for the upper limb and identify the need for further research and developments. METHOD: A systematic literature search was conducted by performing a keyword combination search of the title, abstract and keyword sections in the four databases Web of Science, MedLine, Scopus, and ProQuest. Initially, the retrieved articles were selected by title and abstract using selection criteria. The same criteria were then applied to the full publication text. After the selection process, relevant information on the retrieved orthoses was isolated, sorted and analysed systematically. RESULTS: Forty-six papers, representing 21 orthoses, were identified and analysed according to the mechanical and ergonomic properties. The identified orthoses can be divided into 5 concepts and 16 functional prototypes, then subdivided further based upon their use of passive, semi-active, or active suppression mechanisms. Most of the orthoses concentrate on the wrist and elbow flexion and extension. They mainly rely on rigid structures and actuators while having tremor-suppression efficacies for tremorous subjects from 30 to 98% using power spectral density or other methods. CONCLUSION: The comparison of tremor-suppression orthoses considered and mapped their various mechanical and ergonomic properties, including the degrees of freedom, weight, suppression characteristics, and efficacies. This review shows that most of the orthoses are bulky and heavy, with a non-adapted human-machine interface which can cause rejection by the user. The main challenge of the design of an effective, minimally intrusive and portable tremor-suppressing orthosis is the integration of compact, powerful, lightweight, and non-cumbersome suppression mechanisms. None of the existing prototypes combine all the desired characteristics. Future research should focus on novel suppression orthoses and mechanisms with compact dimensions and light weight in order to be less cumbersome while giving a good tremor-suppression performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Parkinson's disease: clinical features and diagnosis
Jankovic, J. (2008) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2007.131045 · Cited by 5,720
Consensus Statement of the Movement Disorder Society on Tremor
Deuschl, G., Bain, P., & Brin, M. (2008) · Movement Disorders · doi:10.1002/mds.870131303 · Cited by 1,981
A Randomized Trial of Focused Ultrasound Thalamotomy for Essential Tremor
Elias, W. J., Lipsman, N., Ondo, W. G., Ghanouni, P., Kim, Y. G., Lee, W., Schwartz, M., Hynynen, K., Lozano, A. M., Shah, B. B., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1600159 · Cited by 1,167
Louis, E. D., & Ferreira, J. J. (2010) · Movement Disorders · doi:10.1002/mds.22838 · Cited by 906
Older people, assistive technologies, and the barriers to adoption: A systematic review
Yusif, S., Soar, J., & Hafeez-Baig, A. (2016) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2016.07.004 · Cited by 548
Consumer design priorities for upper limb prosthetics
Biddiss, E., Beaton, D., & Chau, T. (2007) · Disability and Rehabilitation: Assistive Technology · doi:10.1080/17483100701714733 · Cited by 519
Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349
Cohen, O., Pullman, S., Jurewicz, E., Watner, D., & Louis, E. D. (2003) · Archives of Neurology · doi:10.1001/archneur.60.3.405 · Cited by 298
A piezoelectric fibre composite based energy harvesting device for potential wearable applications
Swallow, L. M., Luo, J. K., Siores, E., Patel, I., & Dodds, D. (2008) · Smart Materials and Structures · doi:10.1088/0964-1726/17/2/025017 · Cited by 208
Chang, J. W., Park, C. K., Lipsman, N., Schwartz, M. L., Ghanouni, P., Henderson, J. M., Gwinn, R., Witt, J., Tierney, T. S., Cosgrove, G. R., et al. (2018) · Annals of Neurology · doi:10.1002/ana.25126 · Cited by 178
Pathological tremor management: modelling, compensatory technology and evaluation
Rocon, E., Belda-Lois, J. M., Sanchez-Lacuesta, J. J., & Pons, J. L. (2004) · Technology and Disability · doi:10.3233/tad-2004-16102 · Cited by 89
Rehabilitation Robotics: a Wearable Exo-Skeleton for Tremor Assessment and Suppression
Rocon, E., Ruiz, A. F., Pons, J. L., Belda-Lois, J. M., & Sanchez-Lacuesta, J. J. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570451 · Cited by 87
A neuroprosthesis for tremor management through the control of muscle co-contraction
Gallego, J. Á., Rocon, E., Belda-Lois, J. M., & Pons, J. L. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-36 · Cited by 81
Loureiro, R. C. V., Belda-Lois, J. M., Lima, E. R., Pons, J. L., Sanchez-Lacuesta, J. J., & Harwin, W. S. (2005) · 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005. · doi:10.1109/icorr.2005.1501065 · Cited by 70 · cited 1×
“a #4 WOTAS –active attenuator with electrical motor [54]; b #8 Pneumatic Actuator –active attenuator with pneumatic piston-coil system [64]; c #12 DVB Orthosis –semi-active attenuator using tuneable viscous shear resistance [73]; d #21”
BackgroundDiaz, N. L., & Louis, E. D. (2010) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2010.07.011 · Cited by 69
Mechanical suppression of essential tremor
Rocon, E., Manto, M., Pons, J., Camut, S., & Belda, J. M. (2007) · The Cerebellum · doi:10.1080/14734220601103037 · Cited by 68
Electrical stimulation of afferent pathways for the suppression of pathological tremor
Dideriksen, J. L., Laine, C. M., Dosen, S., Muceli, S., Rocon, E., Pons, J. L., Benito-Leon, J., & Farina, D. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00178 · Cited by 67 · cited 2×
“Furthermore, over long-term use the efficacy may be impaired by neural adaptation [89].”
BackgroundA longitudinal study of tremor frequencies in Parkinson’s disease and essential tremor
Hellwig, B., Mund, P., Schelter, B., Guschlbauer, B., Timmer, J., & Lücking, C. H. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.11.002 · Cited by 65
Non-pharmacological and non-surgical interventions for tremor: A systematic review
O’Connor, R. J., & Kini, M. U. (2011) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2010.12.016 · Cited by 55
Adaptive Suppression of Severe Pathological Tremor by Torque Estimation Method
Taheri, B., Case, D., & Richer, E. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2014.2317948 · Cited by 53
Voluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression
Herrnstadt, G., & Menon, C. (2016) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2016.00029 · Cited by 49
Zhou, Y., Naish, M. D., Jenkins, M. E., & Trejos, A. L. (2017) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2016.12.009 · Cited by 46
Ando, T., Robotics and Design for Innovative Healthcare, G. S. O. M., Watanabe, M., Nishimoto, K., Matsumoto, Y., Seki, M., Fujie, M. G., & Graduate School of Creative Science and Engineering, F. O. S. A. E. (2012) · Journal of Robotics and Mechatronics · doi:10.20965/jrm.2012.p0141 · Cited by 27
Development of an Exoskeleton to Support Eating Movements in Patients with Essential Tremor
Matsumoto, Y., Waseda University, 3.-4.-1. O., Seki, M., Ando, T., Kobayashi, Y., Nakashima, Y., Iijima, H., Nagaoka, M., Fujie, M. G., MONOZUKURI Mechatronics Laboratory, K. S. C., et al. (2013) · Journal of Robotics and Mechatronics · doi:10.20965/jrm.2013.p0949 · Cited by 23
Active tremor estimation and suppression in human elbow joint
Taheri, B., Case, D., & Richer, E. (2011) · ASME 2011 Dynamic Systems and Control Conference and Bath/ASME Symposium on Fluid Power and Motion Control, Volume 2 · doi:10.1115/dscc2011-6185 · Cited by 18
Tremor Suppression Using Smart Textile Fibre Systems
Wang, L. (2008) · Journal of Fiber Bioengineering and Informatics · doi:10.3993/jfbi03200902 · Cited by 18 · cited 2×
“17 Piezoelectric Fibre Glove [77, 78] active Piezoelectric fibre composites [77, 78] 2/2 (WFE, WD) [77, 78]”
Background
Cited by
Peripheral electrical stimulation to reduce pathological tremor: a review
Pascual-Valdunciel, A., Hoo, G. W., Avrillon, S., Barroso, F. O., Goldman, J. G., Hernandez-Pavon, J. C., & Pons, J. L. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00811-9 · Cited by 66
“Interest in orthoses based on mechanical tremor reduction has grown over the years, but to date for some interventions patient perception of their use is poor and real-life applications are limited or impractical [14, 15].”
BackgroundA Soft Exoskeleton for Tremor Suppression Equipped with Flexible Semiactive Actuator
Zahedi, A., Zhang, B., Yi, A., & Zhang, D. (2021) · Soft Robotics · doi:10.1089/soro.2019.0194 · Cited by 57
A Novel Soft Glove for Hand Tremor Suppression: Evaluation of Layer Jamming Actuator Placement
Awantha, W. V. I., Wanasinghe, A. T., Kavindya, A. G. P., Kulasekera, A. L., & Chathuranga, D. S. (2020) · 2020 3rd IEEE International Conference on Soft Robotics (RoboSoft) · doi:10.1109/robosoft48309.2020.9115994 · Cited by 31
Metadata
- Authors
- Fromme, N. P., Camenzind, M., Riener, R., & Rossi, R. M.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2019-07-18
- Volume
- 16
- Issue
- 1
- Pages
- 93-93
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2957043630
- Cited by
- 62
- References
- 26
- FWCI
- 0.84
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.