State of the art in total body PET
Open accessThe DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Abstract
The idea of a very sensitive positron emission tomography (PET) system covering a large portion of the body of a patient already dates back to the early 1990s. In the period 2000–2010, only some prototypes with long axial field of view (FOV) have been built, which never resulted in systems used for clinical research. One of the reasons was the limitations in the available detector technology, which did not yet have sufficient energy resolution, timing resolution or countrate capabilities for fully exploiting the benefits of a long axial FOV design. PET was also not yet as widespread as it is today: the growth in oncology, which has become the major application of PET, appeared only after the introduction of PET-CT (early 2000).The detector technology used in most clinical PET systems today has a combination of good energy and timing resolution with higher countrate capabilities and has now been used since more than a decade to build time-of-flight (TOF) PET systems with fully 3D acquisitions. Based on this technology, one can construct total body PET systems and the remaining challenges (data handling, fast image reconstruction, detector cooling) are mostly related to engineering. The direct benefits of long axial FOV systems are mostly related to the higher sensitivity. For single organ imaging, the gain is close to the point source sensitivity which increases linearly with the axial length until it is limited by solid angle and attenuation of the body. The gains for single organ (compared to a fully 3D PET 20-cm axial FOV) are limited to a factor 3–4. But for long objects (like body scans), it increases quadratically with scanner length and factors of 10–40 × higher sensitivity are predicted for the long axial FOV scanner. This application of PET has seen a major increase (mostly in oncology) during the last 2 decades and is now the main type of study in a PET centre. As the technology is available and the full body concept also seems to match with existing applications, the old concept of a total body PET scanner is seeing a clear revival. Several research groups are working on this concept and after showing the potential via extensive simulations; construction of these systems has started about 2 years ago. In the first phase, two PET systems with long axial FOV suitable for large animal imaging were constructed to explore the potential in more experimental settings. Recently, the first completed total body PET systems for human use, a 70-cm-long system, called PennPET Explorer, and a 2-m-long system, called uExplorer, have become reality and first clinical studies have been shown. These results illustrate the large potential of this concept with regard to low-dose imaging, faster scanning, whole-body dynamic imaging and follow-up of tracers over longer periods. This large range of possible technical improvements seems to have the potential to change the current clinical routine and to expand the number of clinical applications of molecular imaging. The J-PET prototype is a prototype system with a long axial FOV built from axially arranged plastic scintillator strips.This paper gives an overview of the recent technical developments with regard to PET scanners with a long axial FOV covering at least the majority of the body (so called total body PET systems). After explaining the benefits and challenges of total body PET systems, the different total body PET system designs proposed for large animal and clinical imaging are described in detail. The axial length is one of the major factors determining the total cost of the system, but there are also other options in detector technology, design and processing for reducing the cost these systems. The limitations and advantages of different designs for research and clinical use are discussed taking into account potential applications and the increased cost of these systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Attenuation correction for a combined 3D PET/CT scanner
Kinahan, P. E., Townsend, D. W., Beyer, T., & Sashin, D. (1998) · Medical Physics · doi:10.1118/1.598392 · Cited by 946
National electrical manufacturers association
(1926) · Journal of the A.I.E.E. · doi:10.1109/jaiee.1926.6537344 · Cited by 860
Analytic 3D image reconstruction using all detected events
Kinahan, P. E., & Rogers, J. G. (1989) · IEEE Transactions on Nuclear Science · doi:10.1109/23.34585 · Cited by 767
Cherry, S. R., Jones, T., Karp, J. S., Qi, J., Moses, W. W., & Badawi, R. D. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.184028 · Cited by 763
Self-citationFirst Human Imaging Studies with the EXPLORER Total-Body PET Scanner*
Badawi, R. D., Shi, H., Hu, P., Chen, S., Xu, T., Price, P. M., Ding, Y., Spencer, B. A., Nardo, L., Liu, W., et al. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.119.226498 · Cited by 722
Surti, S., Kuhn, A., Werner, M. E., Perkins, A. E., Kolthammer, J. A., & Karp, J. S. (2007) · PubMed · Cited by 639
Self-citationDevelopment of new scintillators for medical applications
Lecoq, P. (2016) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2015.08.041 · Cited by 610
Benefit of Time-of-Flight in PET: Experimental and Clinical Results
Karp, J. S., Surti, S., Daube-Witherspoon, M. E., & Muehllehner, G. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.044834 · Cited by 584
Self-citationLevin, C. S., & Hoffman, E. J. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/3/019 · Cited by 551
Image Reconstruction is a New Frontier of Machine Learning
Wang, G., Ye, J. C., Mueller, K., & Fessler, J. A. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2833635 · Cited by 525
Recent developments in time-of-flight PET
Vandenberghe, S., Mikhaylova, E., D’Hoe, E., Mollet, P., & Karp, J. S. (2016) · EJNMMI Physics · doi:10.1186/s40658-016-0138-3 · Cited by 368
Self-citationRecent developments in PET detector technology
Lewellen, T. K. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/17/r01 · Cited by 336
Pushing the Limits in Time-of-Flight PET Imaging
Lecoq, P. (2017) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2017.2756674 · Cited by 302
Muehllehner, G., & Karp, J. S. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/13/r08 · Cited by 288
Self-citationTime-of-flight positron emission tomography: status relative to conventional PET.
Budinger, T. F. (1983) · PubMed · Cited by 283
PET-MRI: a review of challenges and solutions in the development of integrated multimodality imaging
Vandenberghe, S., & Marsden, P. K. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/4/r115 · Cited by 258
Self-citationUltra–Low-Dose18F-Florbetaben Amyloid PET Imaging Using Deep Learning with Multi-Contrast MRI Inputs
Chen, K. T., Gong, E., de Carvalho Macruz, F. B., Xu, J., Boumis, A., Khalighi, M., Poston, K. L., Sha, S. J., Greicius, M. D., Mormino, E., et al. (2019) · Radiology · doi:10.1148/radiol.2018180940 · Cited by 248
Application of Silicon Photomultipliers to Positron Emission Tomography
Roncali, E., & Cherry, S. R. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0266-9 · Cited by 239
Scintillation crystals for PET.
Melcher, C. L. (2000) · PubMed · Cited by 228
PennPET Explorer: Design and Preliminary Performance of a Whole-Body Imager
Karp, J. S., Viswanath, V., Geagan, M. J., Muehllehner, G., Pantel, A. R., Parma, M. J., Perkins, A. E., Schmall, J. P., Werner, M. E., & Daube-Witherspoon, M. E. (2020) · Journal of Nuclear Medicine · doi:10.2967/jnumed.119.229997 · Cited by 198
Self-citationJ-PET: A New Technology for the Whole-body PET Imaging
Niedźwiecki, S., Białas, P., Curceanu, C., Czerwiński, E., Dulski, K., Gajos, A., Głowacz, B., Gorgol, M., Hiesmayr, B. C., Jasińska, B., et al. (2017) · Acta Physica Polonica B · doi:10.5506/aphyspolb.48.1567 · Cited by 197
Self-citationFully three-dimensional reconstruction for a PET camera with retractable septa
Townsend, D. W., Geissbuhler, A., Defrise, M., Hoffman, E. J., Spinks, T. J., Bailey, D. L., Gilardi, M.-C., & Jones, T. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.108584 · Cited by 193
Advances in time-of-flight PET
Surti, S., & Karp, J. S. (2016) · Physica Medica · doi:10.1016/j.ejmp.2015.12.007 · Cited by 173
Self-citationBGO as a hybrid scintillator / Cherenkov radiator for cost-effective time-of-flight PET
Brünner, S., & Schaart, D. R. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa6a49 · Cited by 173
Investigation of time-of-flight benefit for fully 3-DPET
Surti, S., Karp, S., Popescu, L. M., Daube-Witherspoon, E., & Werner, M. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.871419 · Cited by 166
Full-Dose PET Image Estimation from Low-Dose PET Image Using Deep Learning: a Pilot Study
Kaplan, S., & Zhu, Y.-M. (2019) · Journal of Digital Imaging · doi:10.1007/s10278-018-0150-3 · Cited by 165
First experimental results of time-of-flight reconstruction on an LSO PET scanner
Conti, M., Bendriem, B., Casey, M., Chen, M., Kehren, F., Michel, C., & Panin, V. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/19/006 · Cited by 164
Chen, K. T., Gong, E., de Carvalho Macruz, F. B., Xu, J., Boumis, A., Khalighi, M., Poston, K. L., Sha, S. J., Greicius, M. D., Mormino, E., et al. (2020) · Radiology · doi:10.1148/radiol.2020202527 · Cited by 147
A proposal of an open PET geometry
Yamaya, T., Inaniwa, T., Minohara, S., Yoshida, E., Inadama, N., Nishikido, F., Shibuya, K., Lam, C. F., & Murayama, H. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/3/015 · Cited by 143
Krishnamoorthy, S., Blankemeyer, E., Mollet, P., Surti, S., Van Holen, R., & Karp, J. S. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aacec3 · Cited by 141
Self-citationQuantitative image reconstruction for total-body PET imaging using the 2-meter long EXPLORER scanner
Zhang, X., Zhou, J., Cherry, S. R., Badawi, R. D., & Qi, J. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa5e46 · Cited by 130
Poon, J. K., Dahlbom, M. L., Moses, W. W., Balakrishnan, K., Wang, W., Cherry, S. R., & Badawi, R. D. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/13/4077 · Cited by 129
Small-Animal PET: What Is It, and Why Do We Need It?
Yao, R., Lecomte, R., & Crawford, E. S. (2012) · Journal of Nuclear Medicine Technology · doi:10.2967/jnmt.111.098632 · Cited by 127
Photon Time-of-Flight-Assisted Positron Emission Tomography
Ter-Pogossian, M. M., Mullani, N. A., Ficke, D. C., Markham, J., & Snyder, D. L. (1981) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198104000-00014 · Cited by 116
Recent Developments in PET Instrumentation
Peng, H., & Levin, C. S. (2010) · Current Pharmaceutical Biotechnology · doi:10.2174/138920110792246555 · Cited by 112
Evaluation of Single-Chip, Real-Time Tomographic Data Processing on FPGA SoC Devices
Korcyl, G., Hiesmayr, B. C., Jasinska, B., Kacprzak, K., Kajetanowicz, M., Kisielewska, D., Kowalski, P., Kozik, T., Krawczyk, N., Krzemień, W., et al. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2837741 · Cited by 111
Self-citationUsing convolutional neural networks to estimate time-of-flight from PET detector waveforms
Berg, E., & Cherry, S. R. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa9dc5 · Cited by 108
Bismuth germanate coupled to near ultraviolet silicon photomultipliers for time-of-flight PET
Kwon, S. I., Gola, A. G., Ferri, A., Piemonte, C., & Cherry, S. R. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/18/l38 · Cited by 94
Fast reconstruction of 3D time-of-flight PET data by axial rebinning and transverse mashing
Vandenberghe, S., Daube-Witherspoon, M. E., Lewitt, R. M., & Karp, J. S. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/6/017 · Cited by 87
Self-citationMatej, S., Surti, S., Jayanthi, S., Daube-Witherspoon, M. E., Lewitt, R. M., & Karp, J. S. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2012034 · Cited by 85
Self-citationYamamoto, M., Ficke, D. C., & Ter‐Pogossian, M. M. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307571 · Cited by 79
Performance Characteristics of the Whole-Body Discovery IQ PET/CT System
Reynés-Llompart, G., Gámez-Cenzano, C., Romero-Zayas, I., Rodríguez-Bel, L., Vercher-Conejero, J. L., & Martí-Climent, J. M. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.185561 · Cited by 78
Parallax error in long-axial field-of-view PET scanners—a simulation study
Schmall, J. P., Karp, J. S., Werner, M. E., & Surti, S. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/14/5443 · Cited by 77
Self-citationAn investigation of sensitivity limits in PET scanners
Eriksson, L., Townsend, D. W., Conti, M., Eriksson, M., Rothfuß, H., Schmand, M. J., Casey, M. E., & Bendriem, B. (2007) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2007.06.112 · Cited by 65
Surti, S., & Karp, J. S. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/13/5343 · Cited by 57
Self-citationBerg, E., Zhang, X., Bec, J., Judenhofer, M. S., Patel, B., Peng, Q., Kapusta, M., Schmand, M. J., Casey, M., Tarantal, A. F., et al. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.200519 · Cited by 54
Surti, S., Werner, M. E., & Karp, J. S. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/12/3995 · Cited by 48
Self-citationPerformance of a high sensitivity PET scanner based on LSO panel detectors
Conti, M., Bendriem, B., Casey, M. E., Eriksson, L., Jakoby, B., Jones, W. F., Jones, J. P., Michel, C. J., Nahmias, C., Panin, V., et al. (2006) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2006.875153 · Cited by 46
Characterisation of Geiger-mode avalanche photodiodes for medical imaging applications
Britvitch, I., Johnson, I., Renker, D., Stoykov, A., & Eckart Lorenz, G. (2006) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2006.10.089 · Cited by 37
Sparse Detector Configuration in SiPM Digital Photon Counting PET: a Feasibility Study
Zhang, J., Knopp, M. I., & Knopp, M. V. (2018) · Molecular Imaging and Biology · doi:10.1007/s11307-018-1250-7 · Cited by 36
The Dawn of a New Era in Low-Dose PET Imaging
Catana, C. (2018) · Radiology · doi:10.1148/radiol.2018182573 · Cited by 33
Karp, J. S., & Muehllehner, G. (1988) · Springer eBooks · doi:10.1007/978-1-4612-3866-9_4 · Cited by 32
Self-citationMikhaylova, E., Tabacchini, V., Borghi, G., Mollet, P., D‘Hoe, E., Schaart, D. R., & Vandenberghe, S. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa8eb2 · Cited by 20
Self-citationThe 3D complete body screening (3D-CBS) features and implementation
CROSETTO, D. B. (2004) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2003.1352382 · Cited by 18
Abstracts of the Total Body PET conference 2018: Ghent, Belgium. 30 June - 2 July 2018
Caribé, P. R. R. D. V., Koole, M., Bertin, H., D’Asseler, Y., & Vandenberghe, S. (2018) · EJNMMI Physics · doi:10.1186/s40658-018-0218-7 · Cited by 10
Self-citation
Cited by
Limitations and Pitfalls of FDG-PET/CT in Infection and Inflammation
Pijl, J. P., Nienhuis, P. H., Kwee, T. C., Glaudemans, A. W. J. M., Slart, R. H. J. A., & Gormsen, L. C. (2021) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2021.06.008 · Cited by 229
Advanced Monte Carlo simulations of emission tomography imaging systems with GATE
Sarrut, D., Bała, M., Bardiès, M., Bert, J., Chauvin, M., Chatzipapas, K., Dupont, M., Etxebeste, A., M Fanchon, L., Jan, S., et al. (2021) · Physics in Medicine & Biology · doi:10.1088/1361-6560/abf276 · Cited by 204
Self-citationPositronium imaging with the novel multiphoton PET scanner
Moskal, P., Dulski, K., Chug, N., Curceanu, C., Czerwiński, E., Dadgar, M., Gajewski, J., Gajos, A., Grudzień, G., Hiesmayr, B. C., et al. (2021) · Science Advances · doi:10.1126/sciadv.abh4394 · Cited by 180
“The state-of-the-art PET systems (12) [including uEXPLORER, the first total-body PET (13)] use only the information about the location of the positron-electron annihilation and are insensitive to the processes that influence the positron annihilation inside the molecules, which may provide information about the altera…”
Self-citationNew PET technologies – embracing progress and pushing the limits
Aide, N., Lasnon, C., Kesner, A., Levin, C. S., Buvat, I., Iagaru, A., Hermann, K., Badawi, R. D., Cherry, S. R., Bradley, K. M., et al. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05390-4 · Cited by 73
Role of Artificial Intelligence in Theranostics
Brosch-Lenz, J., Yousefirizi, F., Zukotynski, K., Beauregard, J.-M., Gaudet, V., Saboury, B., Rahmim, A., & Uribe, C. (2021) · PET Clinics · doi:10.1016/j.cpet.2021.06.002 · Cited by 42
Metadata
- Authors
- Vandenberghe, S., Moskal, P., & Karp, J. S.
- Venue
- EJNMMI Physics
- Published
- 2020-05-25
- Volume
- 7
- Issue
- 1
- Pages
- 35-35
- ISSN
- 2197-7364 (ISSN-L)
- OpenAlex
- W3030779614
- Cited by
- 390
- References
- 55
- FWCI
- 24.65
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.