Compressed sensing MRI: a review from signal processing perspective
Open accessThe DOI matches its Crossref record; 95 of the 95 references it cites were found in a registry or an index.
Abstract
Magnetic resonance imaging (MRI) is an inherently slow imaging modality, since it acquires multi-dimensional k-space data through 1-D free induction decay or echo signals. This often limits the use of MRI, especially for high resolution or dynamic imaging. Accordingly, many investigators has developed various acceleration techniques to allow fast MR imaging. For the last two decades, one of the most important breakthroughs in this direction is the introduction of compressed sensing (CS) that allows accurate reconstruction from sparsely sampled k-space data. The recent FDA approval of compressed sensing products for clinical scans clearly reflect the maturity of this technology. Therefore, this paper reviews the basic idea of CS and how this technology have been evolved for various MR imaging problems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,591
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639 · cited 5×
“Most of the compressed sensing theories have been developed to address the so-called single measurement vector (SMV) problems [12, 16, 17].”
BackgroundMethodInfluential$rm K$-SVD: An Algorithm for Designing Overcomplete Dictionaries for Sparse Representation
Aharon, M., Elad, M., & Bruckstein, A. (2006) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2006.881199 · Cited by 9,451
Decoding by Linear Programming
Candes, E. J., & Tao, T. (2005) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.858979 · Cited by 7,121
Stable signal recovery from incomplete and inaccurate measurements
Candès, E. J., Romberg, J. K., & Tao, T. (2006) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20124 · Cited by 7,036 · cited 2×
“Compressed sensing (CS) theory [12, 16, 17] addresses the accurate recovery of unknown sparse signals from underdetermined linear measurements and has become one of the main research topics in the signal processing area for the last two decades [18–23].”
BackgroundSparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952 · cited 5×
“[14] showed that the incoherence can be optimized by generalizing the notion of PSF to Transform Point Spread Function (TPSF).”
MethodInfluentialAtomic Decomposition by Basis Pursuit
Chen, S. S., Donoho, D. L., & Saunders, M. A. (1998) · SIAM Journal on Scientific Computing · doi:10.1137/s1064827596304010 · Cited by 6,845 · cited 1×
“Since (P0) requires a computationally expensive combinatorial optimization, greedy methods [24], reweighted norm algorithms [25, 26], or convex relaxation using the l1 norm [12, 27] have been widely investigated as alternatives.”
MethodSENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
A Singular Value Thresholding Algorithm for Matrix Completion
Cai, J.-F., Candès, E. J., & Shen, Z. (2010) · SIAM Journal on Optimization · doi:10.1137/080738970 · Cited by 5,809 · cited 1×
“The problem was solved using the iterative singular value shrinkage method [94].”
MethodGeneralized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303 · cited 18×
“Combination with CS and parallel imaging using GRAPPA type constraints was pioneered by Lustig et al. [40].”
BackgroundMethodInfluentialExact Matrix Completion via Convex Optimization
Candès, E. J., & Recht, B. (2009) · Foundations of Computational Mathematics · doi:10.1007/s10208-009-9045-5 · Cited by 4,877
Enhancing Sparsity by Reweighted ℓ 1 Minimization
Candès, E. J., Wakin, M. B., & Boyd, S. P. (2008) · Journal of Fourier Analysis and Applications · doi:10.1007/s00041-008-9045-x · Cited by 4,863
A First-Order Primal-Dual Algorithm for Convex Problems with Applications to Imaging
Chambolle, A., & Pock, T. (2011) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-010-0251-1 · Cited by 4,336
The Split Bregman Method for L1-Regularized Problems
Goldstein, T., & Osher, S. (2009) · SIAM Journal on Imaging Sciences · doi:10.1137/080725891 · Cited by 4,282 · cited 1×
“For example, the popular op- timization methods such as forward-backward splitting (FBS) [29], split Bregman iteration [30], alternating directional method of multiplier (ADMM) [31], Douglas- Rachford splitting algorithm [32], and primal-dual algorithm [33] have been devel- oped to solve compressed sensing problems.”
MethodConvex Analysis and Monotone Operator Theory in Hilbert Spaces
Bauschke, H. H., & Combettes, P. L. (2017) · CMS Books in Mathematics · doi:10.1007/978-3-319-48311-5 · Cited by 3,307 · cited 1×
“This leads to the development of various techniques, which are culminated as the new type of convex optimizaton theory called proximal optimization [28].”
MethodConvex Analysis and Monotone Operator Theory in Hilbert Spaces
Bauschke, H. H., & Combettes, P. L. (2011) · CMS Books in Mathematics · doi:10.1007/978-1-4419-9467-7 · Cited by 2,962
Signal Recovery by Proximal Forward-Backward Splitting
Combettes, P. L., & Wajs, V. R. (2005) · Multiscale Modeling & Simulation · doi:10.1137/050626090 · Cited by 2,678
Lustig, M., Donoho, D. L., Santos, J. M., & Pauly, J. M. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914728 · Cited by 2,246 · cited 1×
“[14, 15], the compressed sensing MRI has become the essential tools in modern MR imaging researches.”
MethodSimultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
MPEG: a video compression standard for multimedia applications
Le Gall, D. (1991) · Communications of the ACM · doi:10.1145/103085.103090 · Cited by 2,013
A New Alternating Minimization Algorithm for Total Variation Image Reconstruction
Wang, Y., Yang, J., Yin, W., & Zhang, Y. (2008) · SIAM Journal on Imaging Sciences · doi:10.1137/080724265 · Cited by 1,975 · cited 8×
“In order to apply ADMM for (12), we need to focus on the primal formulation of the total variation penalty: TV xð Þ ¼ ∇xk k1;p ¼ Xn i¼1 ∇x ið Þk kp ð14Þ Now, we define a splitting variable u(i) =∇x(i) ∈ Rd.”
MethodInfluentialSparse signal reconstruction from limited data using FOCUSS: a re-weighted minimum norm algorithm
Gorodnitsky, I. F., & Rao, B. D. (1997) · IEEE Transactions on Signal Processing · doi:10.1109/78.558475 · Cited by 1,834 · cited 1×
“Since (P0) requires a computationally expensive combinatorial optimization, greedy methods [24], reweighted norm algorithms [25, 26], or convex relaxation using the l1 norm [12, 27] have been widely investigated as alternatives.”
MethodLearning a variational network for reconstruction of accelerated MRI data
Hammernik, K., Klatzer, T., Kobler, E., Recht, M. P., Sodickson, D. K., Pock, T., & Knoll, F. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26977 · Cited by 1,713
Image reconstruction by domain-transform manifold learning
Zhu, B., Liu, J. Z., Cauley, S. F., Rosen, B. R., & Rosen, M. S. (2018) · Nature · doi:10.1038/nature25988 · Cited by 1,694
Just relax: convex programming methods for identifying sparse signals in noise
Tropp, J. A. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.864420 · Cited by 1,407 · cited 1×
“Since (P0) requires a computationally expensive combinatorial optimization, greedy methods [24], reweighted norm algorithms [25, 26], or convex relaxation using the l1 norm [12, 27] have been widely investigated as alternatives.”
MethodESPIRiT—an eigenvalue approach to autocalibrating parallel MRI: Where SENSE meets GRAPPA
Uecker, M., Lai, P., Murphy, M. J., Virtue, P., Elad, M., Pauly, J. M., Vasanawala, S. S., & Lustig, M. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24751 · Cited by 1,392 · cited 1×
“[85] developed a novel eigen space method to extract the coil sensitivity maps directly from the k-space data, which is one of the most popular methods widely used by MR researchers.”
MethodA deep cascade of convolutional neural networks for dynamic MR image reconstruction
Schlemper, J., Caballero, J., Hajnal, J. V., Price, A. N., & Rueckert, D. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2760978 · Cited by 1,338
Chen, G.-H., Tang, J., & Leng, S. (2008) · Medical Physics · doi:10.1118/1.2836423 · Cited by 1,141
Sampling signals with finite rate of innovation
Vetterli, M., Marziliano, P., & Blu, T. (2002) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2002.1003065 · Cited by 1,079
MR Image Reconstruction From Highly Undersampled k-Space Data by Dictionary Learning
Ravishankar, S., & Bresler, Y. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2090538 · Cited by 1,059 · cited 4×
“[48] employed the following two-step alternating minimization algorithm.”
BackgroundMethodInfluentialSingle disperser design for coded aperture snapshot spectral imaging
Wagadarikar, A., John, R., Willett, R., & Brady, D. (2008) · Applied Optics · doi:10.1364/ao.47.000b44 · Cited by 1,047
Fast Spiral Coronary Artery Imaging
Meyer, C. H., Hu, B. S., Nishimura, D. G., & Macovski, A. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910280204 · Cited by 866
Block, K. T., Uecker, M., & Frahm, J. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21236 · Cited by 824 · cited 1×
“[37] by combining total variation penalty and parallel imaging; and by Liang et al.”
MethodSPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary k‐space
Lustig, M., & Pauly, J. M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22428 · Cited by 822 · cited 2×
“On the other hand, l1-SPIRiT (l1-iTerative Self-consistent Parallel Imaging Re- construction) [40] utilizes the GRAPPA type constraint as an additional constraint for a compressed sensing problem:”
MethodAccelerating magnetic resonance imaging via deep learning
Wang, S., Su, Z., Ying, L., Peng, X., Zhu, S., Liang, F., Feng, D., & Liang, D. (2016) · 2016 IEEE 13th International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2016.7493320 · Cited by 800
k‐t BLAST and k‐t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
Tsao, J., Boesiger, P., & Pruessmann, K. P. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10611 · Cited by 794 · cited 7×
“This observation suggested that the improvement by the classical k-t algorithms such as k-t BLAST/SENSE [5] was not from the Bayesian perspective as the original authors of [5] had claimed, but indeed is originated from exploiting the sparsity int the spatio-temporal domain [18, 20].”
MethodInfluentialFeng, L., Grimm, R., Block, K. T., Chandarana, H., Kim, S., Xu, J., Axel, L., Sodickson, D. K., & Otazo, R. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24980 · Cited by 718 · cited 1×
“[42] later combined compressed sensing, parallel imaging, and golden-angle radial sampling for fast and flexible dynamic volumetric MRI, which has been approved for clinical use.”
MethodSparse channel estimation via matching pursuit with application to equalization
Cotter, S. F., & Rao, B. D. (2002) · IEEE Transactions on Communications · doi:10.1109/26.990897 · Cited by 671
k‐t FOCUSS: A general compressed sensing framework for high resolution dynamic MRI
Jung, H., Sung, K., Nayak, K. S., Kim, E. Y., & Ye, J. C. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21757 · Cited by 669 · cited 24×
“However, there exists two additional novel- ties in the k-t FOCUSS.”
BackgroundMethodResultInfluentialSelf-citationAccelerated Dynamic MRI Exploiting Sparsity and Low-Rank Structure: k-t SLR
Lingala, S. G., Hu, Y., DiBella, E., & Jacob, M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2100850 · Cited by 664
Second order total generalized variation (TGV) for MRI
Knoll, F., Bredies, K., Pock, T., & Stollberger, R. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22595 · Cited by 634 · cited 1×
“[45, 46] proposed a generalized total variation approaches, and Sung et al.”
BackgroundOtazo, R., Kim, D., Axel, L., & Sodickson, D. K. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22463 · Cited by 571
Compressed sensing in dynamic MRI
Gamper, U., Boesiger, P., & Kozerke, S. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21477 · Cited by 569 · cited 2×
“Preliminary CS dynamic MRI approaches [36, 88] were seemingly different from the classical k-t approach such as k-t BLAST/SENSE [5].”
BackgroundMethodA Douglas–Rachford Splitting Approach to Nonsmooth Convex Variational Signal Recovery
Combettes, P. L., & Pesquet, J.-C. (2007) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2007.910264 · Cited by 490 · cited 1×
“For example, the popular op- timization methods such as forward-backward splitting (FBS) [29], split Bregman iteration [30], alternating directional method of multiplier (ADMM) [31], Douglas- Rachford splitting algorithm [32], and primal-dual algorithm [33] have been devel- oped to solve compressed sensing problems.”
MethodHighly Undersampled Magnetic Resonance Image Reconstruction via Homotopic $\ell_{0}$-Minimization
Trzasko, J., & Manduca, A. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.927346 · Cited by 490
Accelerating SENSE using compressed sensing
Liang, D., Liu, B., Wang, J., & Ying, L. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22161 · Cited by 474 · cited 2×
“One of the most simplest approaches can be a SENSE type approach that explic- itly utilizes the estimated coil maps to obtain an augmented compressed sensing problem [18, 20, 38, 84].”
MethodMadore, B., Glover, G. H., & Pelc, N. J. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<813::aid-mrm1>3.0.co;2-s · Cited by 433
Sampling Moments and Reconstructing Signals of Finite Rate of Innovation: Shannon Meets Strang–Fix
Dragotti, P. L., Vetterli, M., & Blu, T. (2007) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2006.890907 · Cited by 428
Calibrationless parallel imaging reconstruction based on structured low-rank matrix completion
Shin, P. J., Larson, P. E. Z., Ohliger, M. A., Elad, M., Pauly, J. M., Vigneron, D. B., & Lustig, M. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24997 · Cited by 391 · cited 7×
“Therefore, SAKE solves the following low- rank matrix completion problem to interpolate the missing k-space data: min M rank H Mð Þð Þ subject to PΩ m i ¼ PΩ yi ; i ¼ 1;⋯;C; where PΩ(·) denotes the projection on the measured k-space samples on the index set Ω.”
BackgroundMethodInfluentialDeep Convolutional Framelets: A General Deep Learning Framework for Inverse Problems
Ye, J. C., Han, Y., & Cha, E. (2018) · SIAM Journal on Imaging Sciences · doi:10.1137/17m1141771 · Cited by 330
Self-citationHaldar, J. P. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2293974 · Cited by 326
k-t SPARSE: High frame rate dynamic MRI exploiting spatio-temporal sparsity
Lustig, M. S., Santos, J. M., Donoho, D. L., & Pauly, J. M. (2006) · Cited by 313
Compressed-Sensing MRI With Random Encoding
Haldar, J. P., Hernando, D., & Liang, Z.-P. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2085084 · Cited by 308 · cited 1×
“[82] and Ye BMC Biomedical Engineering (2019) 1:8 Page 6 of 17”
BackgroundZhao, B., Haldar, J. P., Christodoulou, A. G., & Liang, Z.-P. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2203921 · Cited by 295
Deep learning with domain adaptation for accelerated projection‐reconstruction MR
Han, Y., Yoo, J., Kim, H. H., Shin, H. J., Sung, K., & Ye, J. C. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27106 · Cited by 294
Self-citationCoil compression for accelerated imaging with Cartesian sampling
Zhang, T., Pauly, J. M., Vasanawala, S. S., & Lustig, M. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24267 · Cited by 273 · cited 1×
“Coil compression techniques have been also investigated to reduce the number of coils for CS reconstruction [41].”
BackgroundSampling and reconstruction of signals with finite rate of innovation in the presence of noise
Maravić, I., & Vetterli, M. (2005) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2005.850321 · Cited by 256
Improved k–t BLAST and k–t SENSE using FOCUSS
Jung, H., Ye, J. C., & Kim, E. Y. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/11/018 · Cited by 250 · cited 20×
“However, there exists two additional novel- ties in the k-t FOCUSS.”
MethodResultInfluentialSelf-citationChandarana, H., Feng, L., Block, T. K., Rosenkrantz, A. B., Lim, R. P., Babb, J. S., Sodickson, D. K., & Otazo, R. (2013) · Investigative Radiology · doi:10.1097/rli.0b013e318271869c · Cited by 248
Jin, K. H., Lee, D., & Ye, J. C. (2016) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2016.2601296 · Cited by 245 · cited 6×
“[57] and its theoretical performance guarantees was also given in [62].”
BackgroundMethodInfluentialSelf-citationHighly accelerated real‐time cardiac cine MRI using k–t SPARSE‐SENSE
Feng, L., Srichai, M. B., Lim, R. P., Harrison, A., King, W., Adluru, G., Dibella, E. V. R., Sodickson, D. K., Otazo, R., & Kim, D. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24440 · Cited by 232 · cited 1×
“[39] are among the first that combine the SENSE type parallel imaging with the k-t domain compressed sensing.”
MethodParallel MR Image Reconstruction Using Augmented Lagrangian Methods
Ramani, S., & Fessler, J. A. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2093536 · Cited by 227 · cited 2×
“Algorithm 2 summarises the TV-ADMM algorithm, where shrinkvec,2(x) for x ∈ Rd denotes the vector shrinkage [34]:”
BackgroundMethodLarson, P. E. Z., Hu, S., Lustig, M., Kerr, A. B., Nelson, S. J., Kurhanewicz, J., Pauly, J. M., & Vigneron, D. B. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22650 · Cited by 192 · cited 1×
“[106] developed a CS method for acquiring hyperpolarized 13C data using multiband excitation pulses and achieved 2 s temporal resolution with full volumetric coverage of a mouse.”
MethodSpiral phyllotaxis: The natural way to construct a 3D radial trajectory in MRI
Piccini, D., Littmann, A., Nielles‐Vallespin, S., & Zenge, M. O. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22898 · Cited by 179
Rank-Constrained Solutions to Linear Matrix Equations Using PowerFactorization
Haldar, J. P., & Hernando, D. (2009) · IEEE Signal Processing Letters · doi:10.1109/lsp.2009.2018223 · Cited by 168 · cited 2×
“Because the exact rank of B is not known, the authors proposed the incremented powerFactorization (IRFP) algorithm [92], where (40) starts with L = 1 by increasing order with the initialization of the power factorization of L + 1 from that of L.”
BackgroundCompressed Sensing Single–Breath-Hold CMR for Fast Quantification of LV Function, Volumes, and Mass
Vincenti, G. M., Monney, P. A., Chaptinel, J., Rutz, T., Coppo, S., Zenge, M. O., Schmidt, M., Nadar, M. S., Piccini, D., Chèvre, P., et al. (2014) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2014.04.016 · Cited by 165
A parallel MR imaging method using multilayer perceptron
Kwon, K., Kim, D., & Park, H. (2017) · Medical Physics · doi:10.1002/mp.12600 · Cited by 164
Akçakaya, M., Basha, T., Goddu, B., Goepfert, L. A., Kissinger, K. V., Tarokh, V., Manning, W. J., & Nezafat, R. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22841 · Cited by 158
Off-the-Grid Recovery of Piecewise Constant Images from Few Fourier Samples
Ongie, G., & Jacob, M. (2016) · SIAM Journal on Imaging Sciences · doi:10.1137/15m1042280 · Cited by 134
Ravishankar, S., & Bresler, Y. (2015) · SIAM Journal on Imaging Sciences · doi:10.1137/141002293 · Cited by 131 · cited 2×
“Ravishankar and his colleagues pioneered two distinct approaches - synthesis dictionary learning [48] and analysis transform learning [86] - when the underlying sparsifying transform is unknown a priori.”
BackgroundMethodProjection reconstruction MR imaging using FOCUSS
Ye, J. C., Tak, S., Han, Y., & Park, H. W. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21202 · Cited by 126
Self-citationResolution of crossing fibers with constrained compressed sensing using diffusion tensor MRI
Landman, B. A., Bogovic, J. A., Wan, H., ElShahaby, F. E. Z., Bazin, P.-L., & Prince, J. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.011 · Cited by 124 · cited 1×
“[104] showed that CS reconstruction using standard data can resolve crossing fibers similar to a standard q-ball approach using much richer data with longer acquisition time.”
MethodA new design and rationale for 3D orthogonally oversampled k‐space trajectories
Pipe, J. G., Zwart, N. R., Aboussouan, E., Robison, R. K., Devaraj, A., & Johnson, K. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22918 · Cited by 115
Parallel imaging with nonlinear reconstruction using variational penalties
Knöll, F., Clason, C., Bredies, K., Uecker, M., & Stollberger, R. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22964 · Cited by 113 · cited 1×
“[45, 46] proposed a generalized total variation approaches, and Sung et al.”
BackgroundMotion-adaptive spatio-temporal regularization for accelerated dynamic MRI
Asif, M. S., Hamilton, L., Brummer, M. E., & Romberg, J. K. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24524 · Cited by 112
Acceleration of MR parameter mapping using annihilating filter‐based low rank hankel matrix (ALOHA)
Lee, D., Jin, K. H., Kim, E. Y., Park, S., & Ye, J. C. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26081 · Cited by 110 · cited 9×
“Lee J, Jin KH, Ye JC. Reference-free single-pass EPI Nyquist ghost correction using annihilating filter-based low rank Hankel matrix (ALOHA).”
BackgroundMethodInfluentialSelf-citationSpread Spectrum Magnetic Resonance Imaging
Puy, G., Marques, J. P., Gruetter, R., Thiran, J., Ville, D. V. D., Vandergheynst, P., & Wiaux, Y. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2173698 · Cited by 103 · cited 1×
“[83] proposed random phase encod- ing scheme to maximize the incoherency of the sensing matrix.”
BackgroundHsiao, A., Lustig, M. S., Alley, M. T., Murphy, M., Chan, F. P., Herfkens, R. J., & Vasanawala, S. S. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.11.6969 · Cited by 102 · cited 1×
“[100] applied combined parallel imaging and compressed sensing to achieve 4D phase contrast for the quantification of cardiac flow and ventricular volumes pediatric patients during congenital heart MRI examinations.”
Methodk‐tISD: Dynamic cardiac MR imaging using compressed sensing with iterative support detection
Liang, D., DiBella, E., Chen, R., & Ying, L. L. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23197 · Cited by 100
Simple method for MR gradient system characterization and k ‐space trajectory estimation
Addy, N. O., Wu, H. H., & Nishimura, D. G. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23217 · Cited by 97
Jung, H., & Ye, J. C. (2010) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.20231 · Cited by 96
Self-citationSingle shot concentric shells trajectories for ultra fast fMRI
Zahneisen, B., Hugger, T., Lee, K. J., LeVan, P., Reisert, M., Lee, H., Assländer, J., Zaitsev, M., & Hennig, J. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23256 · Cited by 88
Compressive Sampling Using Annihilating Filter-Based Low-Rank Interpolation
Ye, J. C., Kim, J., Jin, K. H., & Lee, K. (2016) · IEEE Transactions on Information Theory · doi:10.1109/tit.2016.2629078 · Cited by 88 · cited 5×
“[57] and its theoretical performance guarantees was also given in [62].”
BackgroundMethodResultInfluentialSelf-citationKuhnt, D., Bauer, M., Egger, J., Richter, M., Kapur, T., Sommer, J. B., Merhof, D., & Nimsky, C. (2012) · Neurosurgery · doi:10.1227/neu.0b013e318270d9fb · Cited by 78 · cited 1×
“[105] showed that High Angular Resolution Diffusion Imaging (HARDI) + CS is a promising approach for fiber tractography in clinical practice.”
BackgroundMotion Adaptive Patch-Based Low-Rank Approach for Compressed Sensing Cardiac Cine MRI
Yoon, H., Kim, K. S., Kim, D. J., Bresler, Y., & Ye, J. C. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2330426 · Cited by 70
Self-citationLee, J., Jin, K. H., & Ye, J. C. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26077 · Cited by 68 · cited 5×
“Lee J, Jin KH, Ye JC. Reference-free single-pass EPI Nyquist ghost correction using annihilating filter-based low rank Hankel matrix (ALOHA).”
MethodInfluentialSelf-citationUnser, M. A., Tafti, P. D., & Sun, Q. (2014) · IEEE Transactions on Information Theory · doi:10.1109/tit.2014.2298453 · Cited by 63
A Self-Referencing Level-Set Method for Image Reconstruction from Sparse Fourier Samples
Ye, J. C., Bresler, Y., & Moulin, P. (2002) · International Journal of Computer Vision · doi:10.1023/a:1020822324006 · Cited by 57
Self-citationCompressive Sensing Could Accelerate1H MR Metabolic Imaging in the Clinic
Geethanath, S., Baek, H., Ganji, S., Ding, Y., Maher, E. A., Sims, R. D., Choi, C., Lewis, M. A., & Kodibagkar, V. D. (2012) · Radiology · doi:10.1148/radiol.11111098 · Cited by 55 · cited 1×
“[107] demonstrated a potential reduction in acquisition time by up to 80% or more for hydrogen 1 MR spectroscopic imaging using CS, with negligible loss of clinical information.”
BackgroundImproved least squares MR image reconstruction using estimates of k‐Space data consistency
Johnson, K. M., Block, W. F., Reeder, S. B., & Samsonov, A. A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23144 · Cited by 52
Sparse‐CAPR: Highly accelerated 4D CE‐MRA with parallel imaging and nonconvex compressive sensing
Trzasko, J. D., Haider, C. R., Borisch, E. A., Campeau, N. G., Glockner, J. F., Riederer, S. J., & Manduca, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22892 · Cited by 49 · cited 1×
“[43, 44] proposed a direct l0 mimimization approaches, whereas Knoll et al.”
MethodA Unified Formulation of Gaussian Versus Sparse Stochastic Processes—Part II: Discrete-Domain Theory
Unser, M. A., Tafti, P. D., Amini, A., & Kirshner, H. (2014) · IEEE Transactions on Information Theory · doi:10.1109/tit.2014.2311903 · Cited by 44
Improving GRAPPA using cross‐sampled autocalibration data
Wang, H., Liang, D., King, K. F., Nagarsekar, G., Chang, Y., & Ying, L. L. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23083 · Cited by 22
Sparsity and low‐contrast object detectability
Trzasko, J. D., Bao, Z., Manduca, A., McGee, K. P., & Bernstein, M. A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23084 · Cited by 11
Metadata
- Authors
- Ye, J. C.
- Venue
- BMC Biomedical Engineering
- Published
- 2019-03-29
- Volume
- 1
- Issue
- 1
- Pages
- 8-8
- ISSN
- 2524-4426 (ISSN-L)
- OpenAlex
- W2944761405
- Cited by
- 208
- References
- 95
- FWCI
- 11.10
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.