A Multicenter Study of Bispectral Electroencephalogram Analysis for Monitoring Anesthetic Effect
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Bispectral analysis (BIS) of the electroencephalogram (EEG) has been shown in retrospective studies to predict whether patients will move in response to skin incision.This prospective multicenter study was designed to evaluate the real-time utility of BIS in predicting movement response to skin incision using a variety of general anesthetic techniques. Three hundred patients from seven study sites received an anesthetic regimen expected to give an approximately 50% movement response at skin incision. EEG was continuously recorded via an Aspect B-500 monitor and BIS was calculated in real time from bilateral frontocentral channels displayed on the monitor. Half of the patients were randomized to a treatment group in which anesthetic drug doses were increased to produce a lower BIS. In the control group, BIS was recorded, but no action taken on the data displayed. A determination of movement in response to skin incision was made in the 2 min succeeding incision. Retrospective pharmacodynamic modeling was performed using STANPUMP to estimate effect-site concentrations of intravenously administered anesthetics. BIS values were significantly higher in the control group (66 +/- 19) versus the BIS-guided group, in which additional anesthesia was administered to produce a lower BIS (51 +/- 19). The movement response rate was significantly higher in the control group at 43% compared with 13% in the BIS-guided group, but response rates were low at sites which used larger doses of opioids. Logistic regression analysis showed that BIS, estimated opioid effect-site concentrations, and heart rate (in that order) were the best predictors of movement at skin incision. This study demonstrates that dosing anesthetic drugs to lower BIS values achieves a lower probability of movement in response to surgical stimulation. BIS is a significant predictor of patient response to incision, but the utility of the BIS depends on the anesthetic technique being used. When drugs such as propofol or isoflurane are used as the primary anesthetic, changes in BIS correlate with the probability of response to skin incision. When opioid analgesics are used, the correlation to patient movement becomes much less significant, so that patients with apparently "light" EEG profiles may not move or otherwise respond to incision. Therefore, the adjunctive use of opioid analgesics confounds the use of BIS as a measure of anesthetic adequacy when movement response to skin incision is used as the primary end point. (Anesth Analg 1997;84:891-99)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Minimum Alveolar Anesthetic Concentration: A Standard of Anesthetic Potency
Eger, E. I., Saidman, L. J., & Brandstater, B. (1965) · Anesthesiology · doi:10.1097/00000542-196511000-00010 · Cited by 853
An introduction to bispectral analysis for the electroencephalogram
Sigl, J. C., & Chamoun, N. G. (1994) · Journal of Clinical Monitoring · doi:10.1007/bf01618421 · Cited by 804
Pharmacokinetics, Pharmacodynamics, and Rational Opioid Selection
Shafer, S. L., & Varvel, J. R. (1991) · Anesthesiology · doi:10.1097/00000542-199101000-00010 · Cited by 601
Anesthetic Potency (MAC) Is Independent of Forebrain Structures in the Rat
Rampil, I. J., Mason, P., & Singh, H. (1993) · Anesthesiology · doi:10.1097/00000542-199304000-00014 · Cited by 521
Self-citationExaggerated Anesthetic Requirements in the Preferentially Anesthetized Brain
Antognini, J. F., & Schwartz, K. (1993) · Anesthesiology · doi:10.1097/00000542-199312000-00015 · Cited by 506
EEG Quantitation of Narcotic Effect: The Comparative Pharmacodynamics of Fentanyl and Alfentanil
Scott, J. C., Ponganis, K. V., & Stanski, D. R. (1985) · Anesthesiology · doi:10.1097/00000542-198503000-00005 · Cited by 492
Anesthetic Potency Is Not Altered after Hypothermic Spinal Cord Transection in Rats
Rampil, I. J. (1994) · Anesthesiology · doi:10.1097/00000542-199403000-00017 · Cited by 377
Self-citationAwareness and Recall during General Anesthesia: Facts and Feelings
Moerman, N., Bonke, B., & Oosting, J. (1993) · Anesthesiology · doi:10.1097/00000542-199309000-00007 · Cited by 310
Awareness and recall during general anesthesia
Chung, H. S. (2014) · Korean Journal of Anesthesiology · doi:10.4097/kjae.2014.66.5.339 · Cited by 298
CLOSED-LOOP FEEDBACK CONTROL OF PROPOFOL ANAESTHESIA BY QUANTITATIVE EEG ANALYSIS IN HUMANS
SCHWILDEN, H., STOECKEL, H., & SCHÜTTLER, J. (1989) · British Journal of Anaesthesia · doi:10.1093/bja/62.3.290 · Cited by 228
Cited by
A Primer for EEG Signal Processing in Anesthesia
Rampil, I. J. (1998) · Anesthesiology · doi:10.1097/00000542-199810000-00023 · Cited by 1,503
Self-citationDevelopment and Clinical Application of Electroencephalographic Bispectrum Monitoring
Johansen, J. W., Sebel, P. S., & Fisher, D. M. (2000) · Anesthesiology · doi:10.1097/00000542-200011000-00029 · Cited by 599
Self-citationBispectral index for improving anaesthetic delivery and postoperative recovery
Punjasawadwong, Y., Phongchiewboon, A., & Bunchungmongkol, N. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003843.pub3 · Cited by 449
Song, D., Joshi, G. P., & White, P. F. (1997) · Anesthesiology · doi:10.1097/00000542-199710000-00018 · Cited by 412
Self-citationBouillon, T. W., Bruhn, J., Radulescu, L., Andresen, C., Shafer, T. J., Cohane, C., & Shafer, S. L. (2004) · Anesthesiology · doi:10.1097/00000542-200406000-00006 · Cited by 375
Guignard, B., Menigaux, C., Dupont, X., Fletcher, D., & Chauvin, M. (2000) · Anesthesia & Analgesia · doi:10.1097/00000539-200001000-00034 · Cited by 360
Katoh, T., Suzuki, A., & Ikeda, K. (1998) · Anesthesiology · doi:10.1097/00000542-199803000-00014 · Cited by 333
Update on Bispectral Index monitoring
Johansen, J. W. (2006) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2005.08.004 · Cited by 313
Invariant Reversible QEEG Effects of Anesthetics
John, E. R., Prichep, L. S., Kox, W., Valdés-Sosa, P., Bosch-Bayard, J., Aubert, E., Tom, M., diMichele, F., & Gugino, L. D. (2001) · Consciousness and Cognition · doi:10.1006/ccog.2001.0507 · Cited by 274
Iselin-Chaves, I. A., Flaishon, R., Sebel, P. S., Howell, S., Gan, T. J., Sigl, J., Ginsberg, B., & Glass, P. S. A. (1998) · Anesthesia & Analgesia · doi:10.1097/00000539-199810000-00038 · Cited by 267
Self-citationThe neurophysics of consciousness
John, E. R. (2002) · Brain Research Reviews · doi:10.1016/s0165-0173(02)00142-x · Cited by 262
The Bispectral Index Declines During Neuromuscular Block in Fully Awake Persons
Messner, M., Beese, U., Romstöck, J., Dinkel, M., & Tschaikowsky, A. K. (2003) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000072741.78244.c0 · Cited by 261
Romero, L. M., & Remage-Healey, L. (2000) · General and Comparative Endocrinology · doi:10.1006/gcen.2000.7491 · Cited by 259
Bispectral Index Monitoring during Sedation with Sevoflurane, Midazolam, and Propofol
Ibrahim, A. E., Taraday, J. K., & Kharasch, E. D. (2001) · Anesthesiology · doi:10.1097/00000542-200111000-00019 · Cited by 259
The Anesthetic Cascade: A Theory of How Anesthesia Suppresses Consciousness
John, E. R., & Prichep, L. S. (2005) · Anesthesiology · doi:10.1097/00000542-200502000-00030 · Cited by 250
A field theory of consciousness.
John, E. R. (2001) · Consciousness and Cognition · doi:10.1006/ccog.2001.0508 · Cited by 214
“A recently developed anesthesia monitor, which has undergone extensive investigation, combines a variety of EEG features from one or two electrodes into a single number, the bispectral or ‘‘BIS’’ index (Sebel et al., 1997).”
BackgroundAbsalom, A. R., Sutcliffe, N., & Kenny, G. N. (2002) · Anesthesiology · doi:10.1097/00000542-200201000-00017 · Cited by 212
Depth of Anesthesia and Bispectral Index Monitoring
Kissin, I. (2000) · Anesthesia & Analgesia · doi:10.1097/00000539-200005000-00021 · Cited by 197
“When opioid analgesics are used as adjuncts before incision, the correlation to patient movement becomes much less significant, so that patients with apparently “light” EEG profiles may not move at incision (35).”
BackgroundContinuous EEG Monitoring in the Intensive Care Unit: Early Findings and Clinical Efficacy
Vespa, P. M., Nenov, V., & Nuwer, M. R. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199901000-00001 · Cited by 188
Modeling the effects of anesthesia on the electroencephalogram
Bojak, I., & Liley, D. T. J. (2005) · Physical Review E · doi:10.1103/physreve.71.041902 · Cited by 185
Larsen, B., Seitz, A., & Larsen, R. (2000) · Anesthesia & Analgesia · doi:10.1097/00000539-200001000-00035 · Cited by 173
Frenzel, D., Greim, C.-A., Sommer, C., Bauerle, K., & Roewer, N. (2002) · Intensive Care Medicine · doi:10.1007/s00134-001-1183-4 · Cited by 159
“graphy (EEG) could be an alternative objective parameter [2, 3, 4], making this index as a promising approach for assessing the depth of hypnosis during anesthesia [5,6,7,8, 9].”
BackgroundCurrent status of EEG-based depth-of-consciousness monitoring during general anesthesia
Musialowicz, T., & Lahtinen, P. (2014) · Current Anesthesiology Reports · doi:10.1007/s40140-014-0061-x · Cited by 33
“Another multicenter study [20], which monitored the effects of anesthesia on BIS values, demonstrated that dosing anesthetic drugs with the goal of lowering BIS 252 Curr Anesthesiol Rep (2014) 4:251–260”
Background
Metadata
- Authors
- Sebel, P. S., Lang, E., Rampil, I. J., White, P. F., Cork, R., Jopling, M., Smith, N. T., Glass, P. S. A., & Manberg, P.
- Venue
- Anesthesia & Analgesia
- Published
- 1997-04
- Volume
- 84
- Issue
- 4
- Pages
- 891-899
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W4234143596
- Cited by
- 302
- References
- 20
- FWCI
- 17.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.