Bilateral Subthalamic Nucleus Stimulation for Parkinson's Disease: A Systematic Review of the Clinical Literature
The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate the benefits and adverse effects of bilateral subthalamic nucleus stimulation in the treatment of Parkinson's disease (PD) by systematically reviewing the published literature. METHODS: A search of the PubMed database using the key words subthalamic, nucleus, and stimulation yielded 624 articles published between 1966 and December 2003. Only articles that included original, nonduplicated descriptions of patients with PD treated with bilateral subthalamic nucleus stimulation were selected for further analysis. RESULTS: A total of 38 studies from 34 neurosurgical centers in 13 countries were identified for critical review. The outcomes for 471 patients with PD treated with bilateral subthalamic nucleus stimulation were assessed according to the Unified Parkinson's Disease Rating Scale in both on-medication and off-medication conditions. With stimulation, Unified Parkinson's Disease Rating Scale motor scores in the off-medication condition improved by 50% after 6 months, 56% after 12 months, 51% after 2 years, and 49% after 5 years compared with preoperative off-medication scores. At 12 months of subthalamic nucleus stimulation, the mean improvement in tremor was 81%, in rigidity was 63%, in bradykinesia was 52%, in gait was 64%, and in postural instability was 69% when compared with preoperative off-medication subscores. On-medication dyskinesias were reduced by 94%, as assessed 12 months after stimulation using the Unified Parkinson's Disease Rating Scale IV complications of therapy score. There was an overall 52% reduction in the l-dopa-equivalent dose intake after 12 months of stimulation. Most adverse effects were mild to moderate. There was a 1 to 2% incidence of severe adverse effects (death or permanent neurological deficits related to intracerebral hemorrhages). Nineteen percent of the patients had adverse effects related to stimulation that could be reversed by changing stimulation parameters. There was a 9% incidence of adverse effects related to the hardware (infections, lead and pulse generator problems). CONCLUSION: Bilateral subthalamic nucleus stimulation is effective in the treatment of PD. Further refinements in patient selection and surgical technique may lessen the incidence of complications associated with this procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Krack, P., Batir, A., Van Blercom, N., Chabardes, S., Fraix, V., Ardouin, C., Koudsie, A., Limousin, P. D., Benazzouz, A., LeBas, J. F., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035275 · Cited by 2,249
(2001) · New England Journal of Medicine · doi:10.1056/nejmoa000827 · Cited by 1,514
What contributes to quality of life in patients with Parkinson's disease?
Schrag, A. (2000) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.69.3.308 · Cited by 1,380
Core assessment program for intracerebral transplantations (CAPIT)
Langston, J. W., Widner, H., Goetz, C. G., Brooks, D., Fahn, S., Freeman, T., & Watts, R. (1992) · Movement Disorders · doi:10.1002/mds.870070103 · Cited by 1,008
The impact on Parkinson’s disease of electrical parameter settings in STN stimulation
Moro, E., Esselink, R. J. A., Xie, J., Hommel, M., Benabid, A. L., & Pollak, P. (2002) · Neurology · doi:10.1212/wnl.59.5.706 · Cited by 500
Clinical predictive factors of subthalamic stimulation in Parkinson's disease
Welter, M. L., Houeto, J. L., Tezenas du Montcel, S., Mesnage, V., Bonnet, A. M., Pillon, B., Arnulf, I., Pidoux, B., Dormont, D., Cornu, P., et al. (2002) · Brain · doi:10.1093/brain/awf050 · Cited by 426
Safety and efficacy of pallidal or subthalamic nucleus stimulation in advanced PD
Volkmann, J., Allert, N., Voges, J., Weiss, P. H., Freund, H.-J., & Sturm, V. (2001) · Neurology · doi:10.1212/wnl.56.4.548 · Cited by 425
Starr, P. A., Christine, C. W., Theodosopoulos, P. V., Lindsey, N., Byrd, D., Mosley, A., & Marks, W. J. (2002) · Journal of Neurosurgery · doi:10.3171/jns.2002.97.2.0370 · Cited by 415
Long-term Hardware-related Complications of Deep Brain Stimulation
Oh, M. Y., Abosch, A., Kim, S. H., Lang, A. E., & Lozano, A. M. (2002) · Neurosurgery · doi:10.1097/00006123-200206000-00017 · Cited by 405
Self-citationBurchiel, K. J., Anderson, V. C., Favre, J., & Hammerstad, J. P. (1999) · Neurosurgery · doi:10.1097/00006123-199912000-00024 · Cited by 371
Cited by
Deep brain stimulation of the subthalamic nucleus for the treatment of Parkinson's disease
Benabid, A. L., Chabardes, S., Mitrofanis, J., & Pollak, P. (2009) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70291-6 · Cited by 1,285
Probing and regulating dysfunctional circuits using deep brain stimulation
Lozano, A. M., & Lipsman, N. (2013) · Neuron · doi:10.1016/j.neuron.2013.01.020 · Cited by 665
Self-citationMR-guided focused ultrasound thalamotomy for essential tremor: a proof-of-concept study
Lipsman, N., Schwartz, M. L., Huang, Y., Lee, L., Sankar, T., Chapman, M., Hynynen, K., & Lozano, A. M. (2013) · The Lancet Neurology · doi:10.1016/s1474-4422(13)70048-6 · Cited by 604
Self-citationA multicentre study on suicide outcomes following subthalamic stimulation for Parkinson's disease
Voon, V., Krack, P., Lang, A. E., Lozano, A. M., Dujardin, K., Schüpbach, M., D’Ambrosia, J., Thobois, S., Tamma, F., Herzog, J., et al. (2008) · Brain · doi:10.1093/brain/awn214 · Cited by 472
Self-citationTreatment of motor and non-motor features of Parkinson's disease with deep brain stimulation
Fasano, A., Daniele, A., & Albanese, A. (2012) · The Lancet Neurology · doi:10.1016/s1474-4422(12)70049-2 · Cited by 437
Zrinzo, L., Foltynie, T., Limousin, P., & Hariz, M. I. (2012) · Journal of Neurosurgery · doi:10.3171/2011.8.jns101407 · Cited by 366
Adaptive deep brain stimulation (aDBS) controlled by local field potential oscillations
Priori, A., Foffani, G., Rossi, L., & Marceglia, S. (2013) · Experimental Neurology · doi:10.1016/j.expneurol.2012.09.013 · Cited by 331
Subcortical processes of motor response inhibition during a stop signal task
Ray Li, C.-S., Yan, P., Sinha, R., & Lee, T.-W. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.04.023 · Cited by 307
Lee, D. J., Lozano, C. S., Dallapiazza, R. F., & Lozano, A. M. (2019) · Journal of Neurosurgery · doi:10.3171/2019.4.jns181761 · Cited by 302
Self-citationAxial disability and deep brain stimulation in patients with Parkinson disease
Fasano, A., Aquino, C. C., Krauss, J. K., Honey, C. R., & Bloem, B. R. (2015) · Nature Reviews Neurology · doi:10.1038/nrneurol.2014.252 · Cited by 300
Review: Deep brain stimulation in Parkinson’s disease
Groiss, S. J., Wojtecki, L., Südmeyer, M., & Schnitzler, A. (2009) · Therapeutic Advances in Neurological Disorders · doi:10.1177/1756285609339382 · Cited by 280
Bilateral stimulation of the caudal zona incerta nucleus for tremor control
Plaha, P., Khan, S., & Gill, S. S. (2008) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2006.112334 · Cited by 267
First experience with MR-guided focused ultrasound in the treatment of Parkinson's disease
Magara, A., Bühler, R., Moser, D., Kowalski, M., Pourtehrani, P., & Jeanmonod, D. (2014) · Journal of Therapeutic Ultrasound · doi:10.1186/2050-5736-2-11 · Cited by 263
MRI-guided STN DBS in Parkinson's disease without microelectrode recording: efficacy and safety
Foltynie, T., Zrinzo, L., Martinez-Torres, I., Tripoliti, E., Petersen, E., Holl, E., Aviles-Olmos, I., Jahanshahi, M., Hariz, M., & Limousin, P. (2011) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2010.205542 · Cited by 252
Koeglsperger, T., Palleis, C., Hell, F., Mehrkens, J. H., & Bötzel, K. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00410 · Cited by 235
Advances in closed-loop deep brain stimulation devices
Parastarfeizabadi, M., & Kouzani, A. Z. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0295-1 · Cited by 232
“[1] stated that adjusting the stimulation * Correspondence: mparasta@deakin.”
BackgroundHardware-Related Complications of Deep Brain Stimulation: A Review of the Published Literature
Hamani, C., & Lozano, A. M. (2006) · Stereotactic and Functional Neurosurgery · doi:10.1159/000096499 · Cited by 212
“These variables were not taken into account in some of the studies we reviewed. Discussion Hardware-related adverse effects are a major concern for physicians and patients undergoing DBS. Their treatment often requires a prolonged course of antibiotics and surgical procedures to reposition electrodes and to remove and…”
BackgroundSelf-citationFocused ultrasound for neuromodulation
Darrow, D. P. (2019) · Neurotherapeutics · doi:10.1007/s13311-018-00691-3 · Cited by 190
Videnovic, A., & Metman, L. V. (2008) · Movement Disorders · doi:10.1002/mds.21753 · Cited by 172
Cho, Z.-H., Min, H.-K., Oh, S.-H., Han, J.-Y., Park, C.-W., Chi, J.-G., Kim, Y.-B., Paek, S. H., Lozano, A. M., & Lee, K. H. (2010) · Journal of Neurosurgery · doi:10.3171/2010.3.jns091385 · Cited by 169
Self-citationCurrent applications and limitations of surgical treatments for movement disorders
Krack, P., Martinez‐Fernandez, R., del Alamo, M., & Obeso, J. A. (2017) · Movement Disorders · doi:10.1002/mds.26890 · Cited by 122
“There was a 9% incidence of hardware-related adverse events (infections, lead and pulse generator problems).(44) In a series of 1096 patients from the 6 largest available controlled studies on STN and GPi, fatal outcomes related to hemorrhage (0.”
BackgroundDeep brain stimulation: current and future perspectives
Awan, N. R., Lozano, A., & Hamani, C. (2009) · Neurosurgical Focus · doi:10.3171/2009.4.focus0982 · Cited by 83
Self-citation
Metadata
- Authors
- Hamani, C., Richter, E., Schwalb, J. M., & Lozano, A. M.
- Venue
- Neurosurgery
- Published
- 2005-06-01
- Volume
- 56
- Issue
- 6
- Pages
- 1313-1324
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W2037936617
- Cited by
- 280
- References
- 45
- FWCI
- 1.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.