Reports of differing failure rates of total hip prostheses made of various metals prompted us to measure the size of metallic and polyethylene particulate debris around failed cemented arthroplasties. We used an isolation method, in which metallic debris was extracted from the tissues, and a non-isolation method of routine preparation for light and electron microscopy. Specimens were taken from 30 cases in which the femoral component was of titanium alloy (10), cobalt-chrome alloy (10), or stainless steel (10). The mean size of metallic particles with the isolation method was 0.8 to 1.0 microns by 1.5 to 1.8 microns. The non-isolation method gave a significantly smaller mean size of 0.3 to 0.4 microns by 0.6 to 0.7 microns. For each technique the particle sizes of the three metals were similar. The mean size of polyethylene particles was 2 to 4 microns by 8 to 13 microns. They were larger in tissue retrieved from failed titanium-alloy implants than from cobalt-chrome and stainless-steel implants. Our results suggest that factors other than the size of the metal particles, such as the constituents of the alloy, and the amount and speed of generation of debris, may be more important in the failure of hip replacements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldring, S. R., Schiller, A. L., Roelke, M., Rourke, C. M., OʼNeil, D. A., & Harris, W. H. (1983) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198365050-00001 · Cited by 849
The initiation of failure in cemented femoral components of hip arthroplasties
Jasty, M., Maloney, W. J., Bragdon, C. R., O'Connor, D., Haire, T., & Wh, H. (1991) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.73b4.2071634 · Cited by 561
Agins, H. J., Alcock, N. W., Bansal, M., Salvati, E. A., Wilson, P. D., Pellicci, P. M., & Bullough, P. G. (1988) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198870030-00005 · Cited by 496
Self-citationSensitivity to titanium. A cause of implant failure?
Lalor, P., Revell, P., Gray, A., Wright, S., Railton, G., & Freeman, M. (1991) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.73b1.1991768 · Cited by 393
Endosteal erosion in association with stable uncemented femoral components.
Maloney, W. J., Jasty, M., Harris, W. H., Galante, J. O., & Callaghan, J. J. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072070-00011 · Cited by 369
The Pathology of Failed Total Joint Arthroplasty
MIRRA, J. M., MARDER, R. A., & AMSTUTZ, H. C. (1982) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198210000-00023 · Cited by 296
Tissue response to implanted polymers: The significance of sample shape
Matlaga, B. F., Yasenchak, L. P., & Salthouse, T. N. (1976) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820100308 · Cited by 295
Black, J., Sherk, H., Bonini, J., Rostoker, W. R., Schajowicz, F., & Galante, J. O. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072010-00021 · Cited by 187
Some aspects of macrophage behavior at the implant interface
Salthouse, T. N. (1984) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820180407 · Cited by 176
Metal wear and tissue response in failed titanium alloy total hip replacements
Witt, J., & Swann, M. (1991) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.73b4.2071635 · Cited by 161
Cited by
The potential environmental impact of engineered nanomaterials
Colvin, V. L. (2003) · Nature Biotechnology · doi:10.1038/nbt875 · Cited by 2,158
Biological reactions to wear debris in total joint replacement
Ingham, E., & Fisher, J. (2000) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411001535219 · Cited by 708
Biocompatibility of dental casting alloys: A review
Wataha, J. C. (2000) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(00)80016-5 · Cited by 514
Widespread dissemination of metal debris from implants
Case, C., Langkamer, V., James, C., Palmer, M., Kemp, A., Heap, P., & Solomon, L. (1994) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.76b5.8083255 · Cited by 444
Doorn, P. F., Campbell, P. A., Worrall, J., Benya, P. D., McKellop, H. A., & Amstutz, H. C. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199810)42:1<103::aid-jbm13>3.0.co;2-m · Cited by 431
Haynes, D. R., Rogers, S. D., Hay, S., Pearcy, M. J., & Howie, D. W. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199306000-00004 · Cited by 425
Composition and morphology of wear debris in failed uncemented total hip replacement
Shanbhag, A., Jacobs, J., Glant, T., Gilbert, J., Black, J., & Galante, J. (1994) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.76b1.8300684 · Cited by 387
Isolation of predominantly submicron‐sized UHMWPE wear particles from periprosthetic tissues
Campbell, P., Ma, S., Yeom, B., McKellop, H., Schmalzried, T. P., & Amstutz, H. C. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290118 · Cited by 352
Maloney, W. J., Smith, R. L., Schmalzried, T. P., Chiba, J., Huene, D., & Rubash, H. (1995) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199509000-00002 · Cited by 307
Isolation and characterization of debris in membranes around total joint prostheses.
Margevicius, K. J., Bauer, T. W., McMahon, J. T., Brown, S. A., & Merritt, K. (1994) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199411000-00010 · Cited by 270
HUBER, M., REINISCH, G., TRETTENHAHN, G., ZWEYMULLER, K., & LINTNER, F. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.07.032 · Cited by 180
Osteolysis in Association with a Total Hip Arthroplasty with Ceramic Bearing Surfaces*
YOON, T. R., ROWE, S. M., JUNG, S. T., SEON, K. J., & MALONEY, W. J. (1998) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199810000-00007 · Cited by 169
IN VITRO HUMAN MONOCYTE RESPONSE TO WEAR PARTICLES OF TITANIUM ALLOY CONTAINING VANADIUM OR NIOBIUM
Rogers, S. D., Howie, D. W., Graves, S. E., Pearcy, M. J., & Haynes, D. R. (1997) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.79b2.0790311 · Cited by 161
“In our study the wear particles of each material were of comparable size to those found in vivo.(28,30-33) Studies have shown that tissues retrieved during revision surgery for aseptic loosening have had an average of 818 g titanium per gram of tissue.”
Result
Metadata
- Authors
- Lee, J., Salvati, E., Betts, F., DiCarlo, E., Doty, S., & Bullough, P.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 1992-05
- Volume
- 74-B
- Issue
- 3
- Pages
- 380-384
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W2138494900
- Cited by
- 176
- References
- 12
- FWCI
- 11.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.