The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Fourier Domain Mode Locking (FDML): A new laser operating regime and applications for optical coherence tomography
Open accessAbstract
We demonstrate a new technique for frequency-swept laser operation--Fourier domain mode locking (FDML)--and its application for swept-source optical coherence tomography (OCT) imaging. FDML is analogous to active laser mode locking for short pulse generation, except that the spectrum rather than the amplitude of the light field is modulated. High-speed, narrowband optical frequency sweeps are generated with a repetition period equal to the fundamental or a harmonic of cavity round-trip time. An FDML laser is constructed using a long fiber ring cavity, a semiconductor optical amplifier, and a tunable fiber Fabry-Perot filter. Effective sweep rates of up to 290 kHz are demonstrated with a 105 nm tuning range at 1300 nm center wavelength. The average output power is 3mW directly from the laser and 20 mW after post-amplification. Using the FDML laser for swept-source OCT, sensitivities of 108 dB are achieved and dynamic linewidths are narrow enough to enable imaging over a 7 mm depth with only a 7.5 dB decrease in sensitivity. We demonstrate swept-source OCT imaging with acquisition rates of up to 232,000 axial scans per second. This corresponds to 906 frames/second with 256 transverse pixel images, and 3.5 volumes/second with a 256x128x256 voxel element 3-DOCT data set. The FDML laser is ideal for swept-source OCT imaging, thus enabling high imaging speeds and large imaging depths.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Self-citationSensitivity advantage of swept source and Fourier domain optical coherence tomography
Choma, M., Sarunic, M., Yang, C., & Izatt, J. (2003) · Optics Express · doi:10.1364/oe.11.002183 · Cited by 1,794
Measurement of intraocular distances by backscattering spectral interferometry
Fercher, A. F., Hitzenberger, C. K., Kamp, G., & El-Zaiat, S. Y. (1995) · Optics Communications · doi:10.1016/0030-4018(95)00119-s · Cited by 1,212
In vivo human retinal imaging by Fourier domain optical coherence tomography
Wojtkowski, M., Leitgeb, R., Kowalczyk, A., Bajraszewski, T., & Fercher, A. F. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1482379 · Cited by 913
Self-citationHigh-speed optical frequency-domain imaging
Yun, S., Tearney, G., de Boer, J., Iftimia, N., & Bouma, B. (2003) · Optics Express · doi:10.1364/oe.11.002953 · Cited by 865
Optical coherence tomography using a frequency-tunable optical source
Chinn, S. R., Swanson, E. A., & Fujimoto, J. G. (1997) · Optics Letters · doi:10.1364/ol.22.000340 · Cited by 666
Self-citationHigh-speed spectral-domain optical coherence tomography at 13 μm wavelength
Yun, S., Tearney, G., Bouma, B., Park, B., & de Boer, J. (2003) · Optics Express · doi:10.1364/oe.11.003598 · Cited by 399
Wavelength-tuning interferometry of intraocular distances
Lexer, F., Hitzenberger, C. K., Fercher, A. F., & Kulhavy, M. (1997) · Applied Optics · doi:10.1364/ao.36.006548 · Cited by 182
Experimental and theoretical investigations of coherent OFDR with semiconductor laser sources
Passy, R., Gisin, N., von der Weid, J. P., & Gilgen, H. H. (1994) · Journal of Lightwave Technology · doi:10.1109/50.320946 · Cited by 182
Bol’shakov, A. A., Cruden, B. A., & Sharma, S. P. (2004) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/13/4/019 · Cited by 37
Cited by
Imaging and Photodynamic Therapy: Mechanisms, Monitoring, and Optimization
Celli, J. P., Spring, B. Q., Rizvi, I., Evans, C. L., Samkoe, K. S., Verma, S., Pogue, B. W., & Hasan, T. (2010) · Chemical Reviews · doi:10.1021/cr900300p · Cited by 2,324
State-of-the-art retinal optical coherence tomography
DREXLER, W., & FUJIMOTO, J. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2007.07.005 · Cited by 906
Self-citationInfrared laser-absorption sensing for combustion gases
Goldenstein, C. S., Spearrin, R. M., Jeffries, J. B., & Hanson, R. K. (2017) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2016.12.002 · Cited by 701
Optical coherence tomography: a review of clinical development from bench to bedside
Zysk, A. M., Nguyen, F. T., Oldenburg, A. L., Marks, D. L., & Boppart, S. A. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2793736 · Cited by 547
Optical coherence tomography today: speed, contrast, and multimodality
Drexler, W., Liu, M., Kumar, A., Kamali, T., Unterhuber, A., & Leitgeb, R. A. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.7.071412 · Cited by 473
The Development, Commercialization, and Impact of Optical Coherence Tomography
Fujimoto, J., & Swanson, E. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19963 · Cited by 472
Self-citationOptical coherence tomography (OCT): principle and technical realization
Aumann, S., Donner, S., Fischer, J., & Müller, F. (2019) · High Resolution Imaging in Microscopy and Ophthalmology · doi:10.1007/978-3-030-16638-0_3 · Cited by 449
Doppler Optical Coherence Tomography
Leitgeb, R. A., Werkmeister, R. M., Blatter, C., & Schmetterer, L. (2014) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2014.03.004 · Cited by 444
Herink, G., Jalali, B., Ropers, C., & Solli, D. R. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.38 · Cited by 390
Megahertz OCT for ultrawide-field retinal imaging with a 1050nm Fourier domain mode-locked laser
Klein, T., Wieser, W., Eigenwillig, C. M., Biedermann, B. R., & Huber, R. (2011) · Optics Express · doi:10.1364/oe.19.003044 · Cited by 318
Self-citationGrulkowski, I., Liu, J. J., Potsaid, B., Jayaraman, V., Lu, C. D., Jiang, J., Cable, A. E., Duker, J. S., & Fujimoto, J. G. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.002733 · Cited by 308
Self-citationTomographic absorption spectroscopy for the study of gas dynamics and reactive flows
Cai, W., & Kaminski, C. F. (2017) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2016.11.002 · Cited by 280
Time-stretch LiDAR as a spectrally scanned time-of-flight ranging camera
Jiang, Y., Karpf, S., & Jalali, B. (2020) · Nature Photonics · doi:10.1038/s41566-019-0548-6 · Cited by 260
Optical coherence tomography – development, principles, applications
Fercher, A. F. (2010) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2009.11.002 · Cited by 259
Tunable diode laser spectroscopy as a technique for combustion diagnostics
Bolshov, M. A., Kuritsyn, Y. A., & Romanovskii, Y. V. (2015) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2015.01.010 · Cited by 255
Metadata
- Authors
- Huber, R., Wojtkowski, M., & Fujimoto, J. G.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2006-04-17
- Volume
- 14
- Issue
- 8
- Pages
- 3225
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2052802257
- Cited by
- 982
- References
- 10
- FWCI
- 42.42
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.