Unscented Kalman Filter for Brain-Machine Interfaces
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Brain machine interfaces (BMIs) are devices that convert neural signals into commands to directly control artificial actuators, such as limb prostheses. Previous real-time methods applied to decoding behavioral commands from the activity of populations of neurons have generally relied upon linear models of neural tuning and were limited in the way they used the abundant statistical information contained in the movement profiles of motor tasks. Here, we propose an n-th order unscented Kalman filter which implements two key features: (1) use of a non-linear (quadratic) model of neural tuning which describes neural activity significantly better than commonly-used linear tuning models, and (2) augmentation of the movement state variables with a history of n-1 recent states, which improves prediction of the desired command even before incorporating neural activity information and allows the tuning model to capture relationships between neural activity and movement at multiple time offsets simultaneously. This new filter was tested in BMI experiments in which rhesus monkeys used their cortical activity, recorded through chronically implanted multielectrode arrays, to directly control computer cursors. The 10th order unscented Kalman filter outperformed the standard Kalman filter and the Wiener filter in both off-line reconstruction of movement trajectories and real-time, closed-loop BMI operation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 2×
“The Wiener filter has been used in many studies [3,17,18,19,20,44] and remains a staple of BMI research because of its relative simplicity and efficacy.”
MethodBabyak, M. A. (2004) · Psychosomatic Medicine · doi:10.1097/01.psy.0000127692.23278.a9 · Cited by 2,061
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875 · cited 1×
“Research on brain-machine interfaces (BMI) – devices that directly link the brain to artificial actuators [1,2,3] – has experienced rapid development during the last decade primarily because of the expectation that such devices may eventually cure severe body paralysis caused by injury or neurodegenerative disease [4,…”
BackgroundSelf-citationLearning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761 · cited 2×
“The Wiener filter has been used in many studies [3,17,18,19,20,44] and remains a staple of BMI research because of its relative simplicity and efficacy.”
MethodSelf-citationCortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591 · cited 1×
“These include the population vector method [10,11,12,13,14,15,16], the Wiener filter [3,17,18,19,20], the Kalman filter [21,22,23,24], the particle filter [25,26,27,28], point process methods [29,30,31,32], artificial neural networks [18,33,34,35], and discrete state Bayesian approaches [18,36,37,38].”
MethodBashashati, A., Fatourechi, M., Ward, R. K., & Birch, G. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r03 · Cited by 907
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
A high-performance brain–computer interface
Santhanam, G., Ryu, S. I., Yu, B. M., Afshar, A., & Shenoy, K. V. (2006) · Nature · doi:10.1038/nature04968 · Cited by 698 · cited 1×
“These include the population vector method [10,11,12,13,14,15,16], the Wiener filter [3,17,18,19,20], the Kalman filter [21,22,23,24], the particle filter [25,26,27,28], point process methods [29,30,31,32], artificial neural networks [18,33,34,35], and discrete state Bayesian approaches [18,36,37,38].”
MethodCognitive Control Signals for Neural Prosthetics
Musallam, S., Corneil, B. D., Greger, B., Scherberger, H., & Andersen, R. A. (2004) · Science · doi:10.1126/science.1097938 · Cited by 663 · cited 1×
“These include the population vector method [10,11,12,13,14,15,16], the Wiener filter [3,17,18,19,20], the Kalman filter [21,22,23,24], the particle filter [25,26,27,28], point process methods [29,30,31,32], artificial neural networks [18,33,34,35], and discrete state Bayesian approaches [18,36,37,38].”
Method
Cited by
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Self-citationActive tactile exploration using a brain–machine–brain interface
O’Doherty, J. E., Lebedev, M. A., Ifft, P. J., Zhuang, K. Z., Shokur, S., Bleuler, H., & Nicolelis, M. A. L. (2011) · Nature · doi:10.1038/nature10489 · Cited by 629
Self-citationChronic, wireless recordings of large-scale brain activity in freely moving rhesus monkeys
Schwarz, D. A., Lebedev, M. A., Hanson, T. L., Dimitrov, D. F., Lehew, G., Meloy, J., Rajangam, S., Subramanian, V., Ifft, P. J., Li, Z., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2936 · Cited by 348
Self-citationSensors and Decoding for Intracortical Brain Computer Interfaces
Homer, M. L., Nurmikko, A. V., Donoghue, J. P., & Hochberg, L. R. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124640 · Cited by 121
“By combining the two types of model refinements, animals were able to operate iBCIs within an unscented Kalman filter framework, yielding improved performance (94).”
Brain-machine interfaces: an overview.
Lebedev, M. (2014) · Translational Neuroscience · doi:10.2478/s13380-014-0212-z · Cited by 112
Self-citationDesign and analysis of closed-loop decoder adaptation algorithms for brain-machine interfaces
Dangi, S., Orsborn, A. L., Moorman, H. G., & Carmena, J. M. (2013) · Neural Computation · doi:10.1162/neco_a_00460 · Cited by 103
Shanechi, M. M., Hu, R. C., Powers, M., Wornell, G. W., Brown, E. N., & Williams, Z. M. (2012) · Nature Neuroscience · doi:10.1038/nn.3250 · Cited by 96
Robust and accurate decoding of hand kinematics from entire spiking activity using deep learning
Ahmadi, N., Constandinou, T. G., & Bouganis, C.-S. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abde8a · Cited by 69
Computing Arm Movements with a Monkey Brainet
Ramakrishnan, A., Ifft, P. J., Pais-Vieira, M., Byun, Y. W., Zhuang, K. Z., Lebedev, M. A., & Nicolelis, M. A. L. (2015) · Scientific Reports · doi:10.1038/srep10767 · Cited by 54
“The neural decoding algorithm used throughout this study was the unscented Kalman filter (UKF) 37 .”
MethodSelf-citationRecording and decoding for neural prostheses
Warren, D. J., Kellis, S., Nieveen, J. G., Wendelken, S. M., Dantas, H., Davis, T. S., Hutchinson, D. T., Normann, R. A., Clark, G. A., & Mathews, V. J. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2507180 · Cited by 52
Algorithm and hardware considerations for real-time neural signal on-implant processing
Zhang, Z., Savolainen, O. W., & Constandinou, T. G. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac5268 · Cited by 25
“Conventional decoding approaches are adaptive filters like the Wiener filter [39], Wiener cascade filter [40], Kalman filter [41] and unscented Kalman filter [42].”
MethodWillett, F. R., Murphy, B. A., Memberg, W. D., Blabe, C. H., Pandarinath, C., Walter, B. L., Sweet, J. A., Miller, J. P., Henderson, J. M., Shenoy, K. V., et al. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa5990 · Cited by 16
“…a linear decoder increases steadily as a function of the number of electrodes used, though it does so rather slowly (logarithmically) as a function of the number of electrodes, echoing what others have observed (Carmena et al 2003, Fitzsimmons et al 2009, Li et al 2009, Lebedev and Nicolelis 2011).”
Background
Metadata
- Authors
- Li, Z., O'Doherty, J. E., Hanson, T. L., Lebedev, M. A., Henriquez, C. S., & Nicolelis, M. A. L.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2009-07-15
- Volume
- 4
- Issue
- 7
- Pages
- e6243
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2127252652
- Cited by
- 186
- References
- 9
- FWCI
- 4.57
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.