The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Steroid Hormone Analysis by Tandem Mass Spectrometry
Open accessAbstract
Background: New high-performance liquid chromatography/tandem mass spectrometry (LC-MS/MS) methods are among the most successful approaches to improve specificity problems inherent in many immunoassays. Content: We emphasize problems with immunoassays for the measurement of steroids and review the emerging role of LC-MS/MS in the measurement of clinically relevant steroids. The latest generation of tandem mass spectrometers has superior limits of quantification, permitting omission of previously employed derivatization steps. The measurement of steroid profiles in the diagnosis and treatment of congenital adrenal hyperplasia, adrenal insufficiency, chronic pelvic pain and prostatitis, oncology (breast cancer), and athletes has important new applications. Conclusions: LC-MS/MS now affords the specificity, imprecision, and limits of quantification necessary for the reliable measurement of steroids in human fluids, enhancing diagnostic capabilities, particularly when steroid profiles are available.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical review 62: Laboratory assessment of adrenal insufficiency.
Grinspoon, S. K., & Biller, B. M. (1994) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.79.4.7962298 · Cited by 442
Nelson, R. E., Grebe, S. K., O’Kane, D. J., & Singh, R. J. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.025478 · Cited by 359
Carter, G. D., Carter, R., Jones, J., & Berry, J. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.040683 · Cited by 306
Xu, X., Roman, J. M., Issaq, H. J., Keefer, L. K., Veenstra, T. D., & Ziegler, R. G. (2007) · Analytical Chemistry · doi:10.1021/ac070494j · Cited by 260
Guo, T., Taylor, R. L., Singh, R. J., & Soldin, S. J. (2006) · Clinica Chimica Acta · doi:10.1016/j.cca.2006.03.034 · Cited by 227
Self-citationLacey, J. M., Minutti, C. Z., Magera, M. J., Tauscher, A. L., Casetta, B., McCann, M., Lymp, J., Hahn, S. H., Rinaldo, P., & Matern, D. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.027193 · Cited by 216
Standardization of Steroid Hormone Assays: Why, How, and When?
Stanczyk, F. Z., Lee, J. S., & Santen, R. J. (2007) · Cancer Epidemiology, Biomarkers & Prevention · doi:10.1158/1055-9965.epi-06-0765 · Cited by 212
Janzen, N., Peter, M., Sander, S., Steuerwald, U., Terhardt, M., Holtkamp, U., & Sander, J. (2007) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2006-2890 · Cited by 211
Reproducibility of Serum Sex Steroid Assays in Men by RIA and Mass Spectrometry
Hsing, A. W., Stanczyk, F. Z., Bélanger, A., Schroeder, P., Chang, L., Falk, R. T., & Fears, T. R. (2007) · Cancer Epidemiology, Biomarkers & Prevention · doi:10.1158/1055-9965.epi-06-0792 · Cited by 190
Soldin, O. P., Guo, T., Weiderpass, E., Tractenberg, R. E., Hilakivi-Clarke, L., & Soldin, S. J. (2005) · Fertility and Sterility · doi:10.1016/j.fertnstert.2005.02.045 · Cited by 185
Self-citation
Cited by
Urine steroid metabolomics as a biomarker tool for detecting malignancy in adrenal tumors
Arlt, W., Biehl, M., Taylor, A. E., Hahner, S., Libé, R., Hughes, B. A., Schneider, P., Smith, D. J., Stiekema, H., Krone, N., et al. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2011-1565 · Cited by 458
Krone, N., Hughes, B. A., Lavery, G. G., Stewart, P. M., Arlt, W., & Shackleton, C. H. L. (2010) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2010.04.010 · Cited by 434
Kushnir, M. M., Blamires, T., Rockwood, A. L., Roberts, W. L., Yue, B., Erdogan, E., Bunker, A. M., & Meikle, A. W. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2010.143222 · Cited by 283
Wudy, S. A., Schuler, G., Sánchez-Guijo, A., & Hartmann, M. F. (2018) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2017.09.003 · Cited by 236
Krasowski, M. D., Drees, D., Morris, C. S., Maakestad, J., Blau, J. L., & Ekins, S. (2014) · BMC Clinical Pathology · doi:10.1186/1472-6890-14-33 · Cited by 212
“Cross-reactivity to endogenous or exogenous compounds other than the target steroid hormone of the assay may also contribute to differences between immunoassay and LC/MS/MS [4,7,34,60,61].”
Peitzsch, M., Dekkers, T., Haase, M., Sweep, F. C. G. J., Quack, I., Antoch, G., Siegert, G., Lenders, J. W. M., Deinum, J., Willenberg, H. S., et al. (2015) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2014.10.006 · Cited by 169
LC–MS/MS analysis of steroids in the clinical laboratory
Keevil, B. G. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.04.009 · Cited by 149
Standardization of testosterone measurements in humans
Vesper, H. W., & Botelho, J. C. (2010) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2010.03.032 · Cited by 113
Monaghan, P. J., Owen, L. J., Trainer, P. J., Brabant, G., Keevil, B. G., & Darby, D. (2011) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2011.011014 · Cited by 111
A 13-steroid serum panel based on LC-MS/MS: use in detection of adrenocortical carcinoma
Taylor, D. R., Ghataore, L., Couchman, L., Vincent, R. P., Whitelaw, B., Lewis, D., Diaz-Cano, S., Galata, G., Schulte, K.-M., Aylwin, S., et al. (2017) · Clinical Chemistry · doi:10.1373/clinchem.2017.277624 · Cited by 109
Carvalho, V. M. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.08.027 · Cited by 90
Marcos, J., Renau, N., Casals, G., Segura, J., Ventura, R., & Pozo, O. J. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.12.030 · Cited by 76
Jones, R. L., Owen, L. J., Adaway, J. E., & Keevil, B. G. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.11.036 · Cited by 69
Kyriakopoulou, L., Yazdanpanah, M., Colantonio, D. A., Chan, M. K., Daly, C. H., & Adeli, K. (2013) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2013.01.002 · Cited by 68
Janzen, N., Sander, S., Terhardt, M., Steuerwald, U., Peter, M., Das, A. M., & Sander, J. (2011) · Steroids · doi:10.1016/j.steroids.2011.07.013 · Cited by 66
Galuska, C. E., Hartmann, M. F., Sánchez-Guijo, A., Bakhaus, K., Geyer, J., Schuler, G., Zimmer, K.-P., & Wudy, S. A. (2013) · The Analyst · doi:10.1039/c3an36817c · Cited by 64
Prasad, S., Lassetter, B., Welker, K. M., & Mehta, P. H. (2019) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2019.104373 · Cited by 41
“Moreover, MS demonstrates greater specificity and sensitivity in hormone measurement and is free of some of the limitations found in EIAs (Hoofnagle and Wener, 2009; Soldin & Soldin, 2009), thereby making it a highly accurate reference method.”
BackgroundLi, Z.-M., & Kannan, K. (2022) · Toxics · doi:10.3390/toxics10110687 · Cited by 37
“These method are highly sensitive, but lack s lectivity due to nonspecific antigen-antibody inter c ons [15].”
BackgroundMethodHawley, J. M., Owen, L. J., MacKenzie, F., Mussell, C., Cowen, S., & Keevil, B. G. (2016) · Clinical Chemistry · doi:10.1373/clinchem.2015.243576 · Cited by 36
Kim, B., Lee, M.-N., Park, H.-D., Kim, J. W., Chang, Y. S., Park, W. S., & Lee, S.-Y. (2015) · Annals of Laboratory Medicine · doi:10.3343/alm.2015.35.6.578 · Cited by 32
Kalogera, E., Pistos, C., Provatopoulou, X., Athanaselis, S., Spiliopoulou, C., & Gounaris, A. (2013) · Journal of Chromatography B · doi:10.1016/j.jchromb.2013.09.022 · Cited by 31
Zang, T., Tamae, D., Mesaros, C., Wang, Q., Huang, M., Blair, I. A., & Penning, T. M. (2017) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2016.08.001 · Cited by 29
Metadata
- Authors
- Soldin, S. J., & Soldin, O. P.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-06-01
- Volume
- 55
- Issue
- 6
- Pages
- 1061-1066
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2102203236
- Cited by
- 264
- References
- 44
- FWCI
- 18.05
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.