The DOI matches its Crossref record; 92 of the 92 references it cites were found in a registry or an index; 19 of the 46 sources its claims cite were checked for support.
The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments
Open accessAbstract
Background: Currently, a lack of consensus exists on how best to perform and interpret quantitative real-time PCR (qPCR) experiments. The problem is exacerbated by a lack of sufficient experimental detail in many publications, which impedes a reader’s ability to evaluate critically the quality of the results presented or to repeat the experiments. Content: The Minimum Information for Publication of Quantitative Real-Time PCR Experiments (MIQE) guidelines target the reliability of results to help ensure the integrity of the scientific literature, promote consistency between laboratories, and increase experimental transparency. MIQE is a set of guidelines that describe the minimum information necessary for evaluating qPCR experiments. Included is a checklist to accompany the initial submission of a manuscript to the publisher. By providing all relevant experimental conditions and assay characteristics, reviewers can assess the validity of the protocols used. Full disclosure of all reagents, sequences, and analysis methods is necessary to enable other investigators to reproduce results. MIQE details should be published either in abbreviated form or as an online supplement. Summary: Following these guidelines will encourage better experimental practice, allowing more reliable and unequivocal interpretation of qPCR results.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
19 of 46 cited sources checked · 13 supported · 0 flagged · accuracy not yet measured
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“If multiple reactions are performed, however, accurate quantification of lower concentrations can be obtained via digital PCR (29,63,64 )”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > 7.4.3. LOD.
What the sources say
- Not checked — no full text of the sourcecites [29] 2008, Nat Protoc source
- Supportedcites [63] 2008, PLoS ONE source
The Results section explains that digital PCR partitions a sample into hundreds of reaction chambers. At low target concentrations, counting positive chambers closely approximates the true concentration, supporting the claim that multiple reactions enable accurate quantification at lower concentrations. (LLM, conf=0.92)
- Supportedcites [64] 1999, Proc Natl Acad Sci U S A source
The Discussion (page not provided) says digital PCR can detect mutations at relatively low levels and that its detection limit depends on the number of wells analyzed. It also describes quantitative analysis of PCR products, supporting the claim that multiple reactions enable quantification at low levels; the paper’s example concerns rare variants within a sample. (LLM, conf=0.86)
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesEvery source the paper cites for this claim was checked and supports it.
In the paper
“Consequently, many molecular analyses still contain qPCR data that are poorly normalized.”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > 8.1. NORMALIZATION
What the sources say
- Supportedcites [70] 2008, Plant Biotechnol J source
The Introduction (page not provided) reports that more than 95% of RT-PCR analyses surveyed in three plant journals used improperly validated reference genes. This supports the claim that many analyses contained qPCR data at risk of poor normalization, though the paper’s evidence concerns plant research. (LLM, conf=0.91)
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passes- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“which is particularly true for mRNAs that specify proteins that are part of multifunction protein complexes (37 ).”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > 2. Conceptual Considerations
What the sources say
- Partly supportedcites [37] 2007, Mol Syst Biol sourceExperimental — accuracy not yet measured
The Functional pathway analysis reports very low or negative protein–mRNA correlations for most multisubunit protein complexes, supporting the claim of poor concordance for their subunits. It does not establish that these complexes are multifunctional; that qualifier differs from the paper’s “multisubunit.” (LLM, conf=0.82)
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passes- Partly supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“these splicing variants specify alternative protein isoforms”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > 2. Conceptual Considerations
What the sources say
- Supportedcites [31] 2007, BMC Bioinformatics source
The Background states that a given transcript can be predicted to produce a particular protein isoform, supporting the claim that splicing variants specify alternative isoforms. It also cautions that a transcript may not actually be translated, a distinction the claim does not rule out. (LLM, conf=0.90)
- Not checked — no full text of the sourcecites [32] 2008, J Biol Chem source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passes- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“a systematic evaluation has revealed that qPCR data-analysis methods differ substantially in their performance (68 )”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > 8. Data Analysis
What the sources say
- Supportedcites [68] 2007, BMC Bioinformatics source
The Abstract Conclusion states that qPCR data-analysis methods differ significantly in performance. The Discussion’s evaluation of calculation models identifies differences in resolution, precision, and robustness, supporting the citing sentence’s summary. (LLM, conf=0.95)
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passes- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“with variation in splicing patterns reported in different tissues or at different developmental stages.”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > 2. Conceptual Considerations
What the sources say
- Partly supportedcites [31] 2007, BMC Bioinformatics sourceExperimental — accuracy not yet measured
The Utility section describes an exon occurring specifically in muscular, and possibly nervous, tissue; the Construction and content section also describes charts of tissue distribution for splicing events. These passages support variation across tissues, but our copy does not report variation across developmental stages (searched: developmental stages, developmentally regulated splicing). No page numbers are available in the indexed passages. (LLM, conf=0.85)
- Not checked — no full text of the sourcecites [32] 2008, J Biol Chem source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passes- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“no inhibitors copurified with the DNA will distort results, e.g., pathogen detection and their quantification (55 ).”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > 5.2. DNA SAMPLES
What the sources say
- Supportedcites [55] 2005, J Virol Methods source
The Discussion says the internal control reveals PCR inhibitors, while the Abstract says it prevents false-negative results and under-reporting caused by problems with PCR amplification. Together, these passages support the claim that inhibitors carried through DNA preparation can distort pathogen detection and quantification. (LLM, conf=0.90)
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passes- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“different PCR reactions may not be equally susceptible to inhibition by substances copurified in nucleic acid extracts (56,57 ).”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > 5.2. DNA SAMPLES
What the sources say
- Supportedcites [56] 2008, BMC Res Notes source
The Discussion states that inhibitors copurified during nucleic acid extraction can affect different PCR reactions differently. This directly supports the citing sentence. (LLM, conf=0.95)
- Supportedcites [57] 2003, Clin Chem source
The discussion on p. 8 says that inhibitory components in biological samples need not affect all PCRs equally. It also reports a patient sample in which the IgL λ reaction was strongly inhibited while the IgL κ reaction retained its expected efficiency. (LLM, conf=0.94)
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passes- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“variations in tissue-preparation procedures have a substantial effect on both RNA yield and quality (47 ).”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > 4. Sample Acquisition, Handling, and Preparation
What the sources say
- Supportedcites [47] 2007, Biotechniques source
The passage labeled References (page not provided) explicitly says that variations in tissue preparation affected both RNA quality and quantity. It reports RNA yields of 28.3%–97.1% of expected and poststaining quality scores of 2.3–7.9 across protocols. (LLM, conf=0.94)
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passes- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“autosomal nonimprinted genes that display allelic imbalance in their expression have been described (33 ).”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > 2. Conceptual Considerations
What the sources say
- Supportedcites [33] 2008, Genome Res source
The Discussion reports two nonimprinted genes with allele-specific expression imbalance under sequence-dependent cis regulation. The parent-of-origin analysis gives ERAP2 as an example: its allelic skewing depended on the C allele, not parental origin. (LLM, conf=0.94)
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passes- Supported
- It may state two separate claims as one. 12
- Probably not a substantial claim. 6
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“only a couple of interlaboratory comparisons have been performed, and both of these studies emphasized the need for standardization of qPCR diagnostic assays (44,45 ).”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > 3. Research vs Diagnostic Applications
What the sources say
- Not checked — no full text of the sourcecites [44] 2006, Clin Chem source
- Partly supportedcites [45] 2008, J Clin Microbiol sourceExperimental — accuracy not yet measured
The discussion (p. 4) describes this study as the first international evaluation of HIV-2 RNA quantification assays and says the collaboration is working toward standardization because results varied between laboratories. It does not establish that only a couple of interlaboratory comparisons of qPCR diagnostic assays had been performed generally. (LLM, conf=0.85)
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
Every source the paper cites for this claim was checked and supports it.
In the paper
“although qPCR has frequently been proclaimed a touchstone or a gold standard, in practice this “standard” is a variable one, and the reporting of results requires considerable sophistication of analysis and interpretation (43 ).”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > 2. Conceptual Considerations
What the sources say
- Supportedcites [43] 2005, J Mol Endocrinol source
The Introduction says real-time RT-PCR is not an established, standardised technology, while the Normalisation section describes variable results and multiple ways of presenting data. The Conclusion calls the results subjective and urges guidelines for their analysis and reporting. Together, these passages support the claim's characterization of qPCR as a variable standard requiring careful interpretation. (LLM, conf=0.90)
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Rests on an assumption: A large part of the variance in reported RT-qPCR expression values comes from data-processing algorithm corrections rather than solely from protocol variation.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The transcripts of most human genes and many genes in other multicellular organisms are alternatively spliced (31,32 ),”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > 2. Conceptual Considerations
What the sources say
- Partly supportedcites [31] 2007, BMC Bioinformatics sourceExperimental — accuracy not yet measured
The Utility section reports that 61% of the human genes in the database were estimated to undergo alternative splicing, supporting the claim about most human genes. The passages found do not establish the claim about genes in other multicellular organisms; the paper’s analysis here concerns human genes. (LLM, conf=0.86)
- Not checked — no full text of the sourcecites [32] 2008, J Biol Chem source
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Unfortunately, although there is an increased awareness of the importance of systematic validation and although the potentially highly misleading effects of the use of inappropriate reference genes for normalization are widely known, these considerations also are still widely disregarded (70 ).”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > 8.1. NORMALIZATION
What the sources say
- Partly supportedcites [70] 2008, Plant Biotechnol J sourceExperimental — accuracy not yet measured
The Introduction (page not provided) says that improperly validated reference genes remained widely used in plant RT-PCR and that their use may lead to misinterpretation; the paper also demonstrates a misleading normalization result. But it says the importance of earlier findings did not appear to have been recognized, rather than establishing increased awareness or that the risks were widely known. (LLM, conf=0.86)
Load-bearingStrength:boosted· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“alternative, more generalized quantitative models have been developed to correct for differences in amplification efficiency (62 ) and to allow the use of multiple reference genes (30 ).”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > 7.4.1. PCR efficiency.
What the sources say
- Supportedcites [62] 2001, Nucleic Acids Res source
The citation to Pfaffl is attached to the claim about correcting for differences in amplification efficiency, not the separate claim about multiple reference genes. In “Mathematical model for relative quantification in realtime PCR” (page unavailable), the model uses individual efficiencies for the target and reference transcripts; the Discussion contrasts it with a method that presumes identical efficiencies. (LLM, conf=0.92)
- Supportedcites [30] 2007, Genome Biol source
The citation to this source is attached to the use of multiple reference genes. In Results and discussion (§ qBase), the paper describes its generalized model as providing multiple-reference-gene normalization; the Conclusion also states that the model allows normalization with multiple reference genes. (LLM, conf=0.94)
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The necessity for ensuring quality-assurance measures for qPCR and RT-qPCR assays is well recognized (25,44,(75)(76)(77)(78)(79)(80)(81)(82)(83)(84)(85)(86).”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > Conclusions
What the sources say
- Partly supportedcites [25] 2006, BMC Biotechnol sourceExperimental — accuracy not yet measured
The Background (page unavailable) describes measures to improve the reliability of low-level DNA quantification by qPCR. The methods section headed “Reverse primer” (page unavailable) also reports contamination controls and checks on standard-curve quality. These support the need for quality assurance in qPCR, but the paper does not address reverse-transcription qPCR (RT-qPCR). (LLM, conf=0.86)
- Not checked — no full text of the sourcecites [44] 2006, Clin Chem source
- Not checked — no full text of the sourcecites [75] 2005, J Clin Microbiol source
Load-bearingStrength:boosted· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesProbably not a substantial claim.
- Partly supported
In the paper
“however, the use of such arbitrary C q cutoffs is not ideal, because they may be either too low (eliminating valid results) or too high (increasing false-positive results) (26 )”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > 7.4.1. PCR efficiency.
What the sources say
- Not checked — no full text of the sourcecites [26] 2008, Eur Food Res Technol source
Strength:hedged· not yet calibratedCausal:conditional· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“knowledge of the presence and function of specific microRNAs is as important to understanding gene expression as being able to quantify the mRNA species (38 ).”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > 2. Conceptual Considerations
What the sources say
- Not matchedcites [38] 2008, Carcinogenesis
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Strength:boosted· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✗ Checkable: fails✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. It may be too vague to check against evidence. The paper’s conclusions may not depend on it.
- Not matched
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“calculations of relative concentrations will be inaccurate, yielding misleading results.”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > 7.4.1. PCR efficiency.
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“single exon-based RT-qPCR assays may detect a number of splice variants, whereas intron-spanning primers may be more selective but may miss some splice variants altogether.”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > 2. Conceptual Considerations
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
In the paper
“Use of a 3Ј:5Ј assay requires that the PCR efficiencies of both assays be virtually identical (51 ) and not be subject to differential inhibition.”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > 5.1. RNA SAMPLES
What the sources say
- Not checked — no full text of the sourcecites [51] 2006, Nat Protoc source
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Although differences between biological replicates may be large, sufficient numbers may allow smaller experimental differences to be discerned.”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > 8.2. VARIABILITY
Strength:hedged· not yet calibratedCausal:conditional· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Rests on an assumption: The inherent variability of biological systems may rival or exceed experimental differences between groups.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Thus, the reference genes or materials used for standardization are critical, and any assessment of the validity of an RT-qPCR experiment must also consider the appropriateness of the relative-quantification reference.”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > 2. Conceptual Considerations
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
- Rests on an assumption: Most quantitative RNA measurements are relative, not absolute.
In the paper
“The methods produce different results, making it unwise to try to compare data obtained with the different methods (48 ).”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > 5.1. RNA SAMPLES
What the sources say
- Not checked — no full text of the sourcecites [48] 2005, Expert Rev Mol Diagn source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Consequently, power analysis is useful for determining the number of samples necessary for valid conclusions.”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > 8.2. VARIABILITY
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Rests on an assumption: Many factors contribute to experimental variation and influence the number of biological replicates necessary to achieve a given statistical power.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“This difference must be clearly recognized, and one cannot assume that legacy PCR assays can translate directly into the qPCR format.”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > Conclusions
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesProbably not a substantial claim.
- Rests on an assumption: The main difference between qPCR and conventional PCR is the expectation that qPCR can quantify target nucleic acids accurately.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“As a consequence, investigations that use this widely applied technology will produce data that are more uniform, more comparable, and, ultimately, more reliable.”
§ The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments > Conclusions
Tests✓ Asserted: passes✗ Checkable: fails✓ Load-bearing: passes✗ Based: failsProbably not a substantial claim. It may be too vague to check against evidence. The paper may give no reason why it holds. It may state two separate claims as one.
The paper relies on this without support.
Many qPCR publications lack enough experimental detail for readers to assess or repeat the work.
“The problem is exacerbated by a lack of sufficient experimental detail in many publications, which impedes a reader's ability to evaluate critically the quality of the results presented or to repeat the experiments.”
“The problem is exacerbated by the lack of information that characterizes most reports of studies that have used this technology, with many publications not providing sufficient experimental detail to permit the reader to critically evaluate the quality of the results presented or to repeat the experiments.”
The paper relies on this without support.
Presence of an mRNA does not establish that it is translated into protein or functional protein.
“detection of the presence of an mRNA provides no information on whether that mRNA will be translated into a protein or, indeed, whether a functional protein is translated at all.”
The paper relies on this without support.
Most quantitative RNA measurements are relative, not absolute.
“most quantitative RNA data are not absolute, but relative.”
The paper relies on this without support.
A large part of the variance in reported RT-qPCR expression values comes from data-processing algorithm corrections rather than solely from protocol variation.
“Much of the variance in reported expression values produced in RT-qPCR experiments is not simply due to variation in experimental protocols but is caused by corrections applied by various dataprocessing algorithms, each of which makes its own assumptions about the data.”
The paper relies on this without support.
PCR efficiency is highly dependent on the primers used.
“PCR efficiency is highly dependent on the primers used”
The paper relies on this without support.
The structure of the nucleic acid target has a substantial impact on the efficiency of reverse transcription and PCR.
“The structure of the nucleic acid target (e.g., stem and loop secondary RNA structure) has a substantial impact on the efficiency of reverse transcription and the PCR.”
The paper relies on this without support.
A marked presence of primer dimers produces lower PCR efficiency in probe-based assays and may generate false positives in SYBR Green I assays.
“A marked presence of primer dimers produces a lower PCR efficiency in probe-based assays and may generate false positives in assays based on SYBR Green I.”
The paper relies on this without support.
No-template controls detect PCR contamination when probes are used and can distinguish unintended amplification products from intended products in SYBR Green I reactions.
“NTCs detect PCR contamination when probes are used and can also distinguish unintended amplification products (e.g., primer dimers) from the intended PCR products in SYBR Green I reactions.”
The paper relies on this without support.
Robust and precise qPCR assays are usually correlated with high PCR efficiency.
“Robust and precise qPCR assays are usually correlated with high PCR efficiency.”
The paper relies on this without support.
PCR efficiency is particularly important when reporting mRNA concentrations for target genes relative to reference genes.
“PCR efficiency is particularly important when reporting mRNA concentrations for target genes relative to those of reference genes.”
The paper relies on this without support.
A260/A280 measurement is not sufficient for quantitative nucleic acid analysis, especially when measuring minor differences (<10-fold) in cellular mRNA concentrations.
“such measurement is not sufficient if the nucleic acid is to be used for quantitative analysis, especially when the aim is to measure minor differences (Ͻ10-fold) in cellular mRNA concentrations.”
The paper relies on this without support.
RNA integrity numbers relate to rRNA quality and cannot be expected to be an absolute measure of RNA quality.
“these numbers relate to rRNA quality and cannot be expected to be an absolute measure of quality.”
The paper relies on this without support.
The small amplicon size of qPCR assays helps minimize assay-related problems.
“The small amplicon size of qPCR assays helps to minimize assay-related problems”
The paper relies on this without support.
Lower limits of quantification are usually poorly defined.
“Because lower limits of quantification are usually poorly defined, the variation at the lowest concentration claimed to be within the linear interval should be determined.”
The paper relies on this without support.
Low-copy PCRs are stochastically limited.
“Low-copy PCRs are stochastically limited, and LODs of Ͻ3 copies per PCR are not possible.”
The paper relies on this without support.
Precision in qPCR typically varies with concentration, decreasing with copy number.
“Precision in qPCR typically varies with concentration, decreasing with the copy number.”
The paper relies on this without support.
Use of reference genes as internal controls is the most common method for normalizing cellular mRNA data.
“The use of reference genes as internal controls is the most common method for normalizing cellular mRNA data”
The paper relies on this without support.
The inherent variability of biological systems may rival or exceed experimental differences between groups.
“The inherent variability of biological systems may rival or exceed experimental differences between groups.”
The paper relies on this without support.
Many factors contribute to experimental variation and influence the number of biological replicates necessary to achieve a given statistical power.
“Many factors contribute to experimental variation and influence the number of biological replicates necessary to achieve a given statistical power.”
The paper relies on this without support.
The main difference between qPCR and conventional PCR is the expectation that qPCR can quantify target nucleic acids accurately.
“The main difference between qPCR and conventional (legacy) PCR assays is the expectation of the former's potential to quantify target nucleic acids accurately.”
The paper relies on this without support.
The concern about multiplexing accuracy is particularly important when targets of appreciably lower abundance are coamplified with highly abundant targets.
“This concern is of particular importance when targets of appreciably lower abundance are coamplified with highly abundant targets.”
The paper relies on this without support.
Reference gene utility must be experimentally validated for particular tissues or cell types and specific experimental designs.
“their utility must be experimentally validated for particular tissues or cell types and specific experimental designs”
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Gene knockdown and PCR techniques rely upon the correct design and experimental use of RNA targeting reagents and PCR primers, respectively [17–19].”
From Semi-automated fact-checking of nucleotide sequence reagents in biomedical research publications: The Seek & Blastn tool (2019) · cites this paper as [18]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“As the nucleotide sequences of these reagents define their identity and possible experimental use, each published reagent descriptor is recommended to be accompanied by its corresponding nucleotide sequence [18].”
From Semi-automated fact-checking of nucleotide sequence reagents in biomedical research publications: The Seek & Blastn tool (2019) · cites this paper as [18]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The Minimum Information for the Publication of Quantitative Real-Time PCR Experiments (MIQE) guidelines and related articles published thereafter define a rigorous methodology for designing qPCR experiments that assures publication of reproducible and high quality data5–7.”
From Droplet Digital PCR versus qPCR for gene expression analysis with low abundant targets: from variable nonsense to publication quality data (2017) · cites this paper as [5]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The qPCR method was optimized until the characteristics of the standard curve fitted qPCR standard guidelines32 (amplification efficiency (E) = 100 ± 10% and the coefficient of correlation (R2) > 0.95).”
From An apicomplexan parasite drives the collapse of the bay scallop population in New York (2023) · cites this paper as [32]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“it is also essential that some estimation of efficiency is made (25).”
From Comparison of microfluidic digital PCR and conventional quantitative PCR for measuring copy number variation (2012) · cites this paper as [25]
The cited source says what the claim attributes to it.
In the citing paper
“Real-time quantitative PCR was performed in accordance with the MIQE guidelines (Supplementary Table S1 and Supplementary Figure S1) (25).”
From Comparison of microfluidic digital PCR and conventional quantitative PCR for measuring copy number variation (2012) · cites this paper as [25]
The cited source says what the claim attributes to it.
In the citing paper
“Quantitative RT-PCR was conducted following the MIQE (minimum information for publication of quantitative real-time PCR experiments) guidelines38.”
From Neurotoxic reactive astrocytes are induced by activated microglia (2017) · cites this paper as [38]
The cited source says what the claim attributes to it.
In the citing paper
“Relative expression levels from eight independent experiments were calculated using the quantification cycle (Cq) method, according to MIQE guidelines24.”
From TNF-alpha-induced microglia activation requires miR-342: Impact on NF-kB signaling and neurotoxicity (2020) · cites this paper as [24]
In the citing paper
“In line with the MIQE (Minimum Information for Publication of Quantitative Real-Time PCR Experiments), we recommend using at least two housekeeping genes48,49.”
From Algorithmic assessment of cellular senescence in experimental and clinical specimens (2021) · cites this paper as [49]
In the citing paper
“TaqMan® miRNA and gene expression assays either in single-tube or array format were designed to follow MIQE (Minimum Information for Publication of Quantitative Real-Time PCR Experiments) guidelines [53] according to the company’s statement.”
From The Mitochondria-Associated ER Membranes Are Novel Subcellular Locations Enriched for Inflammatory-Responsive MicroRNAs (2020) · cites this paper as [53]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Self-check results appear here once an independent check has confirmed them.
Cited works that were retracted
Works this paper cites that were later retracted, from the retraction notices publishers deposit. Major when the notice came out before this paper was published.
Cites a retracted work: 10.1126/science.1117768
MajorThe cited work was retracted on 2007-04-20 (notice 10.1126/science.316.5823.367b), before this paper was published (2009-04-01). Its authors could have known.
Cited work 10.1126/science.1117768 · retracted 2007-04-20 · notice 10.1126/science.316.5823.367b · this paper published 2009-04-01
“2005, Science, 309, 1694, 10.1126/science.1117768”
Cites a retracted work: 10.1126/science.316.5823.367b
InfoThe cited work was retracted; the date of the notice is not on record.
Cited work 10.1126/science.316.5823.367b · retraction date not known · this paper published 2009-04-01
Citations
Cites
2 retracted
The mRNA of the Arabidopsis Gene FT Moves from Leaf to Shoot Apex and Induces Flowering
Huang, T., Böhlenius, H., Eriksson, S. B., Parcy, F., & Nilsson, O. R. (2005) · Science · doi:10.1126/science.1117768 · Cited by 272
RetractedBöhlenius, H., Eriksson, S. B., Parcy, F., et al. (2007) · Science · doi:10.1126/science.316.5823.367b · Cited by 31
RetractedA new mathematical model for relative quantification in real-time RT-PCR
Pfaffl, M. W. (2001) · Nucleic Acids Research · doi:10.1093/nar/29.9.e45 · Cited by 34,610
Self-citationAnalyzing real-time PCR data by the comparative CT method
Schmittgen, T. D., & Livak, K. J. (2008) · Nature Protocols · doi:10.1038/nprot.2008.73 · Cited by 26,190
Vandesompele, J., De Preter, K., Pattyn, F., Poppe, B., Van Roy, N., De Paepe, A., & Speleman, F. (2002) · Genome Biology · doi:10.1186/gb-2002-3-7-research0034 · Cited by 20,038
Self-citationPfaffl, M. W. (2002) · Nucleic Acids Research · doi:10.1093/nar/30.9.e36 · Cited by 7,377
Self-citationAndersen, C. L., Jensen, J. L., & Ørntoft, T. F. (2004) · Cancer Research · doi:10.1158/0008-5472.can-04-0496 · Cited by 7,127
Minimum information about a microarray experiment (MIAME)-toward standards for microarray data
Brazma, A., Hingamp, P., Quackenbush, J., Sherlock, G., Spellman, P., Stoeckert, C., Aach, J., Ansorge, W., Ball, C. A., Causton, H. C., et al. (2001) · Nature Genetics · doi:10.1038/ng1201-365 · Cited by 4,109
Hellemans, J., Mortier, G., De Paepe, A., Speleman, F., & Vandesompele, J. (2007) · Genome Biology · doi:10.1186/gb-2007-8-2-r19 · Cited by 4,023
Self-citationBustin, S. A. (2000) · Journal of Molecular Endocrinology · doi:10.1677/jme.0.0250169 · Cited by 3,844
Self-citationCorrelation between Protein and mRNA Abundance in Yeast
Gygi, S. P., Rochon, Y., Franza, B. R., & Aebersold, R. (1999) · Molecular and Cellular Biology · doi:10.1128/mcb.19.3.1720 · Cited by 3,819
Sivia, D. S. (1996) · Cited by 2,677
Quantification of mRNA using real-time RT-PCR
Nolan, T., Hands, R. E., & Bustin, S. A. (2006) · Nature Protocols · doi:10.1038/nprot.2006.236 · Cited by 2,247
Self-citationKinetic PCR Analysis: Real-time Monitoring of DNA Amplification Reactions
Higuchi, R., Fockler, C., Dollinger, G. D., & Watson, R. H. (1993) · Nature Biotechnology · doi:10.1038/nbt0993-1026 · Cited by 2,205
Real-time RT-PCR normalisation; strategies and considerations
Huggett, J. F., Dheda, K. U. J., Bustin, S. A., & Zumla, A. I. (2005) · Genes and Immunity · doi:10.1038/sj.gene.6364190 · Cited by 1,858
Self-citationVogelstein, B., & Kinzler, K. W. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.16.9236 · Cited by 1,770
Product Differentiation by Analysis of DNA Melting Curves during the Polymerase Chain Reaction
Ririe, K. M., Rasmussen, R. P., & Wittwer, C. T. (1997) · Analytical Biochemistry · doi:10.1006/abio.1996.9916 · Cited by 1,663
Self-citationGabert, J. A., Beillard, E. J., van der Velden, V. H. J., Bi, W., Grimwade, D. J., Pallisgaard, N., Barbany, G., Cazzaniga, G., Cayuela, J., Cavé, H., et al. (2003) · Leukemia · doi:10.1038/sj.leu.2403135 · Cited by 1,534
The real-time polymerase chain reaction
Kubista, M., Andrade, J. M., Bengtsson, M., Forootan, A., Jonák, J., Lind, K., Sindelka, R., Sjöback, R., Sjögreen, B., Strömbom, L., et al. (2006) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2005.12.007 · Cited by 1,515
Self-citationRNA integrity and the effect on the real-time qRT-PCR performance
Fleige, S., & Pfaffl, M. W. (2006) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2005.12.003 · Cited by 1,488
Self-citationMackay, I. M. (2002) · Nucleic Acids Research · doi:10.1093/nar/30.6.1292 · Cited by 1,321
Quantitative real-time RT-PCR – a perspective
Bustin, S. A., Benes, V, Nolan, T., & Pfaffl, M. W. (2005) · Journal of Molecular Endocrinology · doi:10.1677/jme.1.01755 · Cited by 1,321
Self-citationContinuous Fluorescence Monitoring of Rapid Cycle DNA Amplification
Wittwer, C. T., Herrmann, M. G., Moss, A. A., & Rasmussen, R. P. (2013) · BioTechniques · doi:10.2144/000114043 · Cited by 1,279
Self-citationSimultaneous Amplification and Detection of Specific DNA Sequences
Higuchi, R., Dollinger, G. D., Walsh, P. S., & Griffith, R. L. (1992) · Nature Biotechnology · doi:10.1038/nbt0492-413 · Cited by 1,176
The minimum information about a genome sequence (MIGS) specification
Field, D., Garrity, G. M., Gray, T., Morrison, N., Selengut, J., Sterk, P., Tatusova, T. A., Thomson, N. R., Allen, M. J., Angiuoli, S. V., et al. (2008) · Nature Biotechnology · doi:10.1038/nbt1360 · Cited by 1,148
Continuous Fluorescence Monitoring of Rapid Cycle DNA Amplification
Wittwer, C. T., Herrmann, M. G., Moss, A. A., & Rasmussen, R. P. (1997) · BioTechniques · doi:10.2144/97221bi01 · Cited by 1,144
Self-citationPitfalls of quantitative real-time reverse-transcription polymerase chain reaction.
Bustin, S. A., & Nolan, T. (2004) · PubMed · Cited by 1,036
Self-citationMultiplex PCR: Optimization and Application in Diagnostic Virology
Elnifro, E. M., Ashshi, A. M., Cooper, R. J., & Klapper, P. E. (2000) · Clinical Microbiology Reviews · doi:10.1128/cmr.13.4.559 · Cited by 966
Real-time PCR in the microbiology laboratory
Mackay, I. M. (2004) · Clinical Microbiology and Infection · doi:10.1111/j.1198-743x.2004.00722.x · Cited by 824
The minimum information about a proteomics experiment (MIAPE)
Taylor, C. F., Paton, N. W., Lilley, K. S., Binz, P., Julian, R. K., Jones, A. R., Zhu, W., Apweiler, R., Aebersold, R. H., Deutsch, E. W., et al. (2007) · Nature Biotechnology · doi:10.1038/nbt1329 · Cited by 769
Gutierrez, L., Mauriat, M., Guénin, S., Pelloux, J., Lefebvre, J., Louvet, R., Rusterucci, C., Moritz, T., Guerineau, F., Bellini, C., et al. (2008) · Plant Biotechnology Journal · doi:10.1111/j.1467-7652.2008.00346.x · Cited by 696
Taylor, C. F., Field, D., Sansone, S.-A., Aerts, J., Apweiler, R., Ashburner, M., Ball, C. A., Binz, P.-A., Bogue, M., Booth, T., et al. (2008) · Nature Biotechnology · doi:10.1038/nbt.1411 · Cited by 558
Self-citationReal-time reverse transcription PCR (qRT-PCR) and its potential use in clinical diagnosis
Bustin, S. A., & Mueller, R. D. (2005) · Clinical Science · doi:10.1042/cs20050086 · Cited by 524
Self-citationStandardization of real-time PCR gene expression data from independent biological replicates
Willems, E., Leyns, L., & Vandesompele, J. (2008) · Analytical Biochemistry · doi:10.1016/j.ab.2008.04.036 · Cited by 490
Self-citationDorak, M. T. (2009) · Medical Entomology and Zoology · Cited by 464
The Metabolomics Standards Initiative
MSI Board Members: (2007) · Nature Biotechnology · doi:10.1038/nbt0807-846b · Cited by 454
Minimizing the risk of reporting false positives in large-scale RNAi screens
Echeverri, C. J., Beachy, P. A., Baum, B., Boutros, M., Buchholz, F., Chanda, S. K., Downward, J., Ellenberg, J., Fraser, A. G., Hacohen, N., et al. (2006) · Nature Methods · doi:10.1038/nmeth1006-777 · Cited by 440
Properties of the Reverse Transcription Reaction in mRNA Quantification
Ståhlberg, A., Håkansson, J., Xian, X., Semb, H., & Kubista, M. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.026161 · Cited by 409
Self-citationStatistical significance of quantitative PCR
Karlen, Y., McNair, A., Perseguers, S., Mazza, C., & Mermod, N. (2007) · BMC Bioinformatics · doi:10.1186/1471-2105-8-131 · Cited by 373
RNA Quality Control in Eukaryotes
Doma, M. K., & Parker, R. (2007) · Cell · doi:10.1016/j.cell.2007.10.041 · Cited by 345
Real-time multiplex PCR assays.
Wittwer, C., Herrmann, M., Gundry, C. N., & Elenitoba-Johnson, K. (2001) · Methods · doi:10.1006/meth.2001.1265 · Cited by 330
Self-citationDube, S., Qin, J., & Ramakrishnan, R. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002876 · Cited by 302
Polymorphisms within micro-RNA-binding sites and risk of sporadic colorectal cancer
Landi, D., Gemignani, F., Naccarati, A., Pardini, B., Vodička, P., Vodičková, Ľ., Novotný, J. P., Försti, A., Hemminki, K., Canzian, F., et al. (2007) · Carcinogenesis · doi:10.1093/carcin/bgm304 · Cited by 276
Real-Time PCR Technology for Cancer Diagnostics
Bernard, P. S., & Wittwer, C. T. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.8.1178 · Cited by 270
Self-citationSPUD: A quantitative PCR assay for the detection of inhibitors in nucleic acid preparations
Nolan, T., Hands, R., Ogunkolade, W. B., & Bustin, S. A. (2006) · Analytical Biochemistry · doi:10.1016/j.ab.2006.01.051 · Cited by 258
Self-citationDifferential susceptibility of PCR reactions to inhibitors: an important and unrecognised phenomenon
Huggett, J. F., Novak, T., Garson, J. A., Green, C., Morris-Jones, S. D., Miller, R. F., & Zumla, A. (2008) · BMC Research Notes · doi:10.1186/1756-0500-1-70 · Cited by 250
Self-citationComparison of Reverse Transcriptases in Gene Expression Analysis
Ståhlberg, A., Kubista, M., & Pfaffl, M. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.035469 · Cited by 240
Self-citationRTPrimerDB: the Real-Time PCR primer and probe database
Pattyn, F. (2003) · Nucleic Acids Research · doi:10.1093/nar/gkg011 · Cited by 240
Biobanking of fresh frozen tissue: RNA is stable in nonfixed surgical specimens
Micke, P., Ohshima, M., Tahmasebpoor, S., Ren, Z.-P., Östman, A., Pontén, F., & Botling, J. (2006) · Laboratory Investigation · doi:10.1038/labinvest.3700372 · Cited by 230
Routes to improving the reliability of low level DNA analysis using real-time PCR
Ellison, S. L., English, C. A., Burns, M. J., & Keer, J. T. (2006) · BMC Biotechnology · doi:10.1186/1472-6750-6-33 · Cited by 207
Molecular microbiology: diagnostic principles and practice.
Persing, D. H., & Tenover, F. C. (2011) · EUR Research Repository (Erasmus University Rotterdam) · Cited by 205
Modelling the limit of detection in real-time quantitative PCR
Burns, M., & Valdivia, H. (2008) · European Food Research and Technology · doi:10.1007/s00217-007-0683-z · Cited by 181
Burns, M. J., Nixon, G. J., Foy, C. A., et al. (2005) · BMC Biotechnology · doi:10.1186/1472-6750-5-31 · Cited by 179
RDML: structured language and reporting guidelines for real-time quantitative PCR data
Lefever, S., Hellemans, J., Pattyn, F., Przybylski, D. R., Taylor, C. F., Geurts, R., Untergasser, A., & Vandesompele, J. (2009) · Nucleic Acids Research · doi:10.1093/nar/gkp056 · Cited by 165
Self-citationUniversal Reference RNA as a standard for microarray experiments
Novoradovskaya, N., Whitfield, M. L., Basehore, L. S., Novoradovsky, A., Pesich, R., Usary, J., Karaca, M., Wong, W. K., Aprelikova, O. N., Fero, M. J., et al. (2004) · BMC Genomics · doi:10.1186/1471-2164-5-20 · Cited by 165
Garson, J. A., Grant, P. R., Ayliffe, U., Ferns, R. B., & Tedder, R. S. (2005) · Journal of Virological Methods · doi:10.1016/j.jviromet.2005.03.001 · Cited by 158
Self-citationvan der Velden, V. H. J., Panzer‐Grümayer, E. R., Cazzaniga, G., et al. (2007) · Leukemia · doi:10.1038/sj.leu.2404535 · Cited by 151
Genome-wide Analysis of Alternative Pre-mRNA Splicing
Ben-Dov, C., Hartmann, B., Lundgren, J., & Valcárcel, J. (2008) · Journal of Biological Chemistry · doi:10.1074/jbc.r700033200 · Cited by 151
Real-time, fluorescence-based quantitative PCR: a snapshot of current procedures and preferences
Bustin, S. A. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.4.493 · Cited by 144
Self-citationStåhlberg, A., Åman, P., Ridell, B., Mostad, P., & Kubista, M. (2003) · Clinical Chemistry · doi:10.1373/49.1.51 · Cited by 128
Self-citationRTPrimerDB: the real-time PCR primer and probe database, major update 2006
Pattyn, F. (2005) · Nucleic Acids Research · doi:10.1093/nar/gkj155 · Cited by 118
van den Berg, R. J., Vaessen, N., Endtz, H. P., et al. (2006) · Journal of Medical Microbiology · doi:10.1099/jmm.0.46680-0 · Cited by 118
Comparative proteomic and transcriptomic profiling of the fission yeast Schizosaccharomyces pombe
Schmidt, M. W., Houseman, A., Ivanov, A. R., & Wolf, D. A. (2007) · Molecular Systems Biology · doi:10.1038/msb4100117 · Cited by 114 · cited 1×
“It is now well established that there is frequently a lack of concordance between mRNA- and proteinconcentration data (36), which is particularly true for mRNAs that specify proteins that are part of multifunction protein complexes ( 37 ).”
BackgroundApfalter, P., Reischl, U., & Hammerschlag, M. R. (2005) · Journal of Clinical Microbiology · doi:10.1128/jcm.43.12.5835-5841.2005 · Cited by 104
Multiplex PCR by multicolor fluorimetry and fluorescence melting curve analysis
Elenitoba‐Johnson, K. S. J., Bohling, S. D., Wittwer, C. T., et al. (2001) · Nature Medicine · doi:10.1038/84708 · Cited by 81
Self-citationUniversal RNA Reference Materials for Gene Expression
Cronin, M. T., Ghosh, K., Sistare, F. D., Quackenbush, J. F., Vilker, V. L., & O’Connell, C. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.035675 · Cited by 80
de la Grange, P., Dutertre, M., Correa, M., & Auboeuf, D. (2007) · BMC Bioinformatics · doi:10.1186/1471-2105-8-180 · Cited by 78
de Vries, T. J., Fourkour, A., Punt, C. J. A., et al. (1999) · British Journal of Cancer · doi:10.1038/sj.bjc.6690436 · Cited by 77
Swango, K. L., Hudlow, W. R., Timken, M. D., et al. (2006) · Forensic Science International · doi:10.1016/j.forsciint.2006.09.002 · Cited by 71
Winters, M. A., Tan, L., Katzenstein, D. A., & Merigan, T. C. (1993) · Journal of Clinical Microbiology · doi:10.1128/jcm.31.11.2960-2966.1993 · Cited by 71
Sjöholm, M., Dillner, J., & Carlson, J. A. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2007.087510 · Cited by 70
SNP-specific array-based allele-specific expression analysis
Bjornsson, H. T., Albert, T. J., Ladd-Acosta, C. M., Green, R. D., Rongione, M. A., Middle, C. M., Irizarry, R. A., Broman, K. W., & Feinberg, A. P. (2008) · Genome Research · doi:10.1101/gr.073254.107 · Cited by 68
Damond, F., Benard, A., Ruelle, J., Alabi, A., Kupfer, B., Gomes, P., Rodes, B., Albert, J., Böni, J., Garson, J., et al. (2008) · Journal of Clinical Microbiology · doi:10.1128/jcm.00126-08 · Cited by 54
Self-citationFerns, R. B., & Garson, J. A. (2006) · Journal of Virological Methods · doi:10.1016/j.jviromet.2006.02.005 · Cited by 47
Self-citationde Crémoux, P., Bièche, I., Tran‐Perennou, C., et al. (2004) · Endocrine Related Cancer · doi:10.1677/erc.1.00808 · Cited by 47
EQUAL-quant: An International External Quality Assessment Scheme for Real-Time PCR
Ramsden, S. C., Daly, S., Geilenkeuser, W.-J., Duncan, G., Hermitte, F., Marubini, E., Neumaier, M., Orlando, C., Palicka, V., Paradiso, A., et al. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.066019 · Cited by 45
Real-time reverse transcription PCR and the detection of occult disease in colorectal cancer
Bustin, S. A., & Mueller, R. D. (2006) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2005.12.002 · Cited by 44
Self-citationBurns, M. J., Valdivia, H., & Harris, N. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2441-9 · Cited by 39
Garson, J. A., Huggett, J. F., Bustin, S. A., Pfaffl, M. W., Beneš, V., Vandesompele, J., & Shipley, G. L. (2009) · AIDS Research and Human Retroviruses · doi:10.1089/aid.2008.0270 · Cited by 34
Self-citationRockett, J. (2002) · Genome Biology · doi:10.1186/gb-2002-3-7-reports0034 · Cited by 32
Increasing the Robustness and Validity of RNAi Screens
Haney, S. A. (2007) · Pharmacogenomics · doi:10.2217/14622416.8.8.1037 · Cited by 32
External quality control assessment in PCR diagnostics of dengue virus infections
Lemmer, K., Mantke, O. D., Bae, H., et al. (2003) · Journal of Clinical Virology · doi:10.1016/j.jcv.2003.11.002 · Cited by 31
Morrogh, M., Olvera, N., Bogomolniy, F., Borgen, P. I., & King, T. A. (2007) · BioTechniques · doi:10.2144/000112497 · Cited by 29
A Thank You from Tulane University
Levy, L. S. (2007) · Science · doi:10.1126/science.316.5823.367c · Cited by 26
Raggi, C. C., Verderio, P., Pazzagli, M., et al. (2005) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2005.094 · Cited by 21
Effects of Plate Position, Plate Type and Sealing Systems on Real-Time PCR Results
Reiter, M., & Pfaffl, M. W. (2008) · Biotechnology & Biotechnological Equipment · doi:10.1080/13102818.2008.10817561 · Cited by 14
Self-citationCiabatti, I., Froiio, A., Gatto, F., et al. (2006) · PubMed · Cited by 13
Wang, X., Jia, S., Meyer, L., Xiang, B., Chen, L.-Y., Jiang, N., Moreno, C., Jacob, H. J., Ghosh, S., & Hessner, M. J. (2006) · BMC Bioinformatics · doi:10.1186/1471-2105-7-378 · Cited by 12
Statistical Diagnostics Emerging from External Quality Control of Real-Time PCR
Marubini, E., Verderio, P., Raggi, C. C., et al. (2004) · The International Journal of Biological Markers · doi:10.1177/172460080401900209 · Cited by 10
RNA Reference Materials for Gene Expression Studies
Joseph, L. J. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.032441 · Cited by 8
RNA Reference Materials for Gene Expression Studies
Gingeras, T. R. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.030072 · Cited by 7
External quality control assessment in PCR diagnostics of dengue virus infections
LEMMER, K. (2004) · Journal of Clinical Virology · doi:10.1016/s1386-6532(03)00300-7
Flagged first, then by citations
Research works printed but not linked: 8
- 1993, Biotechnology (N Y), 11, 1026
- 2004, J Biomol Tech, 15, 155
- 2009, Forthcoming
- 2007, Science, 316, 367
- 2007, Nat Biotechnol, 25, 846
- 2008, Carcinogenesis, 29, 579
- 2006, Dev Biol (Basel), 126, 79
- 2005, Clin Chem Lab Med, 43, 542
Cited by
Sorted by citations
Neurotoxic reactive astrocytes are induced by activated microglia
Liddelow, S. A., Guttenplan, K. A., Clarke, L. E., Bennett, F. C., Bohlen, C. J., Schirmer, L., Bennett, M. L., Münch, A. E., Chung, W.-S., Peterson, T. C., et al. (2017) · Nature · doi:10.1038/nature21029 · Cited by 7,971
The biogenesis, biology and characterization of circular RNAs
Kristensen, L. S., Andersen, M. S., Stagsted, L. V. W., Ebbesen, K. K., Hansen, T. B., & Kjems, J. (2019) · Nature Reviews Genetics · doi:10.1038/s41576-019-0158-7 · Cited by 4,823
Welsh, J. A., Goberdhan, D. C. I., O'Driscoll, L., Buzas, E. I., Blenkiron, C., Bussolati, B., Cai, H., Di Vizio, D., Driedonks, T. A. P., Erdbrügger, U., et al. (2024) · Journal of Extracellular Vesicles · doi:10.1002/jev2.12404 · Cited by 4,663
Cell-free nucleic acids as biomarkers in cancer patients
Schwarzenbach, H., Hoon, D. S. �., & Pantel, K. (2011) · Nature reviews. Cancer · doi:10.1038/nrc3066 · Cited by 2,897
Environmental DNA – An emerging tool in conservation for monitoring past and present biodiversity
Thomsen, P. F., & Willerslev, E. (2015) · Biological Conservation · doi:10.1016/j.biocon.2014.11.019 · Cited by 2,082
Metadata
- Authors
- Bustin, S. A., Benes, V., Garson, J. A., Hellemans, J., Huggett, J., Kubista, M., Mueller, R., Nolan, T., Pfaffl, M. W., Shipley, G. L., Vandesompele, J., & Wittwer, C. T.
- Affiliations
- Queen Mary University of London (GB)
- Genomics Core Facility, EMBL Heidelberg, Heidelberg, Germany
- University College London Hospitals NHS Foundation Trust (GB)
- Ghent University Hospital (BE)
- University College London (GB)
- Czech Academy of Sciences, Institute of Biotechnology (CZ)
- Sequenom (United States) (US)
- Sigma–Aldrich, Haverhill, UK
- Technical University of Munich (DE)
- The University of Texas Health Science Center at Houston (US)
- University of Utah (US)
- Corresponding author
- Bustin, Stephen A
- ORCID
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-04-01
- Volume
- 55
- Issue
- 4
- Pages
- 611-622
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2168420558
- Cited by
- 16,303
- References
- 92
- Citations by year
- 2026: 1198 · 2025: 1087 · 2024: 1107 · 2023: 1118 · 2022: 1157 · 2021: 1339 · 2020: 1264 · 2019: 1139 · 2018: 1082 · 2017: 1067 · 2016: 991 · 2015: 944 · 2014: 832 · 2013: 704 · 2012: 556
- FWCI
- 168.11
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model (vor)
- Locations
- Clinical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Ghent University Academic Bibliography (Ghent University) (submittedVersion)
- UCL Discovery (University College London) (submittedVersion)
- mediaTUM – the media and publications repository of the Technical University Munich (Technical University Munich) (submittedVersion, other-oa)
- Funders
- Bowel and Cancer Research (1119105)
- ARUP Institute for Clinical and Experimental Pathology
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Social Sciences › Library and Information Sciences › Academic Writing and Publishing
- Keywords
- MIQE guidelines, quantitative real-time PCR, reporting guidelines, reproducibility, scientific integrity
- MeSH terms
- Humans, Terminology as Topic, Nucleic Acids, Publishing, Time Factors, Polymerase Chain Reaction, Molecular Diagnostic Techniques, Reverse Transcription
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-07, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-07 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review