Effects of Image Scale and System Time Delay on Simulator Sickness within Head-Coupled Virtual Environments
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Novel patterns of visual-vestibular intersensory stimulation often result in symptoms of simulator sickness, raising health and safety concerns regarding virtual environment exposure. Two experiments investigated the effect of conflicting visual-vestibular cues on subjective reports of simulator sickness during and after a 30-min exposure to a head-coupled virtual interface. Virtual image scale factors (0.5, 1.0, 2.0 magnification, generated by varying geometric field of view angle) were investigated in Experiment 1, and additional system time delays (125, 250 ms) were investigated in Experiment 2. Simulator sickness metrics included spoken self-reports during exposure and simulator sickness questionnaires (pre-exposure, immediate postexposure, and 20 min postexposure). Head yaw angular position data were also recorded. Reports of simulator sickness symptoms were significantly greater in the minification (0.5) and magnification (2.0) image scale factor conditions than in the neutral condition (1.0). Simulator sickness did not vary with changes in time delay, however. Furthermore, a comparison across experiments suggests no appreciable increase in simulator sickness with increasing time delays above the nominal value (48 ms). Head angular position data exhibited certain systematic variations across conditions. Actual or potential applications of this research include virtual environment training, simulation, and entertainment systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Simulator Sickness Questionnaire: An Enhanced Method for Quantifying Simulator Sickness
Kennedy, R. S., Lane, N. E., Berbaum, K. S., & Lilienthal, M. G. (1993) · The International Journal of Aviation Psychology · doi:10.1207/s15327108ijap0303_3 · Cited by 5,457
Motion Sickness Adaptation: A Neural Mismatch Model
Reason, J. T. (1978) · Journal of the Royal Society of Medicine · doi:10.1177/014107687807101109 · Cited by 932 · cited 1×
“This theory, as presented by Reason (1978), states that “all situations which provoke motion sickness are characterized by a condition of sensory rearrangement in which the motion signals transmitted by the eyes, the vestibular system and the nonvestibular propri-oceptors are at variance either…”
BackgroundAn ecological Theory of Motion Sickness and Postural Instability
Riccio, G. E., & Stoffregen, T. A. (1991) · Ecological Psychology · doi:10.1207/s15326969eco0303_2 · Cited by 761 · cited 1×
“An alternative to the sensory rearrangement theory is the ecological theory of motion sickness (Riccio & Stoffregen, 1991), which states that environments creating an extended period of postural instability will produce sickness symptoms.”
BackgroundCybersickness: Perception of Self-Motion in Virtual Environments
McCauley, M. E., & Sharkey, T. J. (1992) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.1992.1.3.311 · Cited by 508 · cited 1×
“Many of these imperfections, when combined with the high-bandwidth multisensory coupling between human and computer, are theorized to induce simulator sickness (McCauley & Sharkey, 1992; Regan, 1995; Rushton, Mon-Williams, & Wann, 1994).”
BackgroundMotion Sickness: An Evolutionary Hypothesis
Treisman, M. (1977) · Science · doi:10.1126/science.301659 · Cited by 393 · cited 1×
“This theory also does not answer the question of why sensory rearrangements should be nauseogenic, though Treisman (1977) presented one possible explanation with his evolutionary hypothesis (i.e., that motion sickness is an accidental triggering of a system that rids an individual of ingested…”
BackgroundMotion sickness: only one provocative conflict?
Bles, W., Bos, J. E., de Graaf, B., Groen, E., & Wertheim, A. H. (1998) · Brain Research Bulletin · doi:10.1016/s0361-9230(98)00115-4 · Cited by 335
An Ecological Critique of the Sensory Conflict Theory of Motion Sickness
Stoffregen, T. A., & Riccio, G. E. (1991) · Ecological Psychology · doi:10.1207/s15326969eco0303_1 · Cited by 174 · cited 1×
“…offers explanatory value but little prediction regarding which sensory rearrangements will result in sickness symptoms and which will not, and it is unclear as to what operationally constitutes a “sensory rearrangement” (Ebenholtz, Cohen, & Linder, 1994; Griffin, 1990; Stoffregen & Riccio, 1991).”
BackgroundMotion Sickness and Oculomotor Systems in Virtual Environments
Ebenholtz, S. M. (1992) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.1992.1.3.302 · Cited by 103 · cited 3×
“System time delays are hypothesized to be among the areas most in need of improvement in simulators and virtual interface design (Ebenholtz, 1992; Kennedy et al., 1990).”
Background
Cited by
Review on cybersickness in applications and visual displays
Rebenitsch, L., & Owen, C. (2016) · Virtual Reality · doi:10.1007/s10055-016-0285-9 · Cited by 971
Virtual Reality Sickness: A Review of Causes and Measurements
Chang, E., Kim, H. T., & Yoo, B. (2020) · International Journal of Human–Computer Interaction · doi:10.1080/10447318.2020.1778351 · Cited by 969
Validating an Efficient Method to Quantify Motion Sickness
Keshavarz, B., & Hecht, H. (2011) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720811403736 · Cited by 634
Munafo, J., Diedrick, M., & Stoffregen, T. A. (2017) · Experimental Brain Research · doi:10.1007/s00221-016-4846-7 · Cited by 566
Characteristics of Head-Mounted Displays and Their Effects on Simulator Sickness
Moss, J. D., & Muth, E. R. (2011) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720811405196 · Cited by 241
Sevinc, V., & Berkman, M. I. (2020) · Applied Ergonomics · doi:10.1016/j.apergo.2019.102958 · Cited by 205
Visually Induced Motion Sickness Predicted by Postural Instability
Smart, L. J., Stoffregen, T. A., & Bardy, B. G. (2002) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1518/0018720024497745 · Cited by 204
Perceptual Issues in the Use of Head-Mounted Visual Displays
Patterson, R., Winterbottom, M. D., & Pierce, B. J. (2006) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1518/001872006778606877 · Cited by 200
“Simulator sickness has also been report-ed with the use of HMDs and can be caused by a number of factors (Draper, Viirre, Furness, & Gawron, 2001; Draper, Viirre, Furness, & Parker, 1997; Ehrlich, 1997).”
BackgroundCzerwinski, M., Tan, D. S., & Robertson, G. G. (2002) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/503376.503412 · Cited by 186
“It has been recently reported that it is harmful to deviate from a 1:1 ratio of FOV and DFOV [9].”
BackgroundPleasant music as a countermeasure against visually induced motion sickness
Keshavarz, B., & Hecht, H. (2014) · Applied Ergonomics · doi:10.1016/j.apergo.2013.07.009 · Cited by 143
The effect of internal and external fields of view on visually induced motion sickness
Bos, J. E., de Vries, S. C., van Emmerik, M. L., & Groen, E. L. (2010) · Applied Ergonomics · doi:10.1016/j.apergo.2009.11.007 · Cited by 124
Postural Instability and Motion Sickness in a Virtual Moving Room
Villard, S. J., Flanagan, M. B., Albanese, G. M., & Stoffregen, T. A. (2008) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1518/001872008x250728 · Cited by 121
Combined Pitch and Roll and Cybersickness in a Virtual Environment
Bonato, F., Bubka, A., & Palmisano, S. (2009) · Aviation, Space, and Environmental Medicine · doi:10.3357/asem.2394.2009 · Cited by 110
Visually induced motion sickness can be alleviated by pleasant odors
Keshavarz, B., Stelzmann, D., Paillard, A., & Hecht, H. (2015) · Experimental Brain Research · doi:10.1007/s00221-015-4209-9 · Cited by 100
Stance Width Influences Postural Stability and Motion Sickness
Stoffregen, T. A., Yoshida, K., Villard, S., Scibora, L., & Bardy, B. G. (2010) · Ecological Psychology · doi:10.1080/10407413.2010.496645 · Cited by 87
Motion control, motion sickness, and the postural dynamics of mobile devices
Stoffregen, T. A., Chen, Y.-C., & Koslucher, F. C. (2014) · Experimental Brain Research · doi:10.1007/s00221-014-3859-3 · Cited by 65
Metadata
- Authors
- Draper, M. H., Viirre, E. S., Furness, T. A., & Gawron, V. J.
- Venue
- Human Factors: The Journal of the Human Factors and Ergonomics Society
- Publisher
- SAGE Publications
- Published
- 2001-03
- Volume
- 43
- Issue
- 1
- Pages
- 129-146
- ISSN
- 0018-7208 (ISSN-L)
- 1547-8181
- OpenAlex
- W2103933566
- Cited by
- 206
- References
- 8
- FWCI
- 5.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.