The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Effect of Postoperative Mechanical Axis Alignment on the Fifteen-Year Survival of Modern, Cemented Total Knee Replacements
Abstract
BACKGROUND: One long-held tenet of total knee arthroplasty is that implant durability is maximized when postoperative limb alignment is corrected to 0° ± 3° relative to the mechanical axis. Recently, substantial health-care resources have been devoted to computer navigation systems that allow surgeons to more often achieve that alignment. We hypothesized that a postoperative mechanical axis of 0° ± 3° would result in better long-term survival of total knee arthroplasty implants as compared with that in a group of outliers. METHODS: Clinical and radiographic data were reviewed retrospectively to determine the fifteen-year Kaplan-Meier survival rate following 398 primary total knee arthroplasties performed with cement in 280 patients from 1985 to 1990. Preoperatively, most knees were in varus mechanical alignment (mean and standard deviation, 6° ± 8.8° of varus [range, 30° of varus to 22° of valgus]), whereas postoperatively most knees were corrected to neutral (mean and standard deviation, 0° ± 2.8° [range, 8° of varus to 9° of valgus]). Postoperatively, we defined a mechanically aligned group of 292 knees (with a mechanical axis of 0° ± 3°) and an outlier group of 106 knees (with a mechanical axis of beyond 0° ± 3°). RESULTS: At the time of the latest follow-up, forty-five (15.4%) of the 292 implants in the mechanically aligned group had been revised for any reason, compared with fourteen (13%) of the 106 implants in the outlier group (p = 0.88); twenty-seven (9.2%) of the 292 implants in the mechanically aligned group had been revised because of aseptic loosening, mechanical failure, wear, or patellar problems, compared with eight (7.5%) of the 106 implants in the outlier group (p = 0.88); and seventeen (5.8%) of the 292 implants in the mechanically aligned group had been revised because of aseptic loosening, mechanical failure, or wear, compared with four (3.8%) of the 106 implants in the outlier group (p = 0.49). CONCLUSIONS: A postoperative mechanical axis of 0° ± 3° did not improve the fifteen-year implant survival rate following these 398 modern total knee arthroplasties. We believe that describing alignment as a dichotomous variable (aligned versus malaligned) on the basis of a mechanical axis goal of 0° ± 3° is of little practical value for predicting the durability of modern total knee arthroplasty implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Coronal alignment after total knee replacement
Jeffery, R., Morris, R., & Denham, R. (1991) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.73b5.1894655 · Cited by 1,100
Power and Sample Size Calculations for Studies Involving Linear Regression
Dupont, W. D., & Plummer, W. D. (1998) · Controlled Clinical Trials · doi:10.1016/s0197-2456(98)00037-3 · Cited by 1,024
Postoperative Alignment of Total Knee Replacement Its Effect on Survival
RITTER, M. A., FARIS, P. M., KEATING, E. M., & MEDING, J. B. (1994) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199402000-00021 · Cited by 1,008
Normal Axial Alignment of the Lower Extremity and Load-Bearing Distribution at the Knee
Hsu, R. W., HIMENO, S., Coventry, M. B., et al. (1990) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199006000-00029 · Cited by 781
Supracondylar Humeral Fractures in Children
Omid, R., Choi, P. D., & Skaggs, D. L. (2008) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.g.01354 · Cited by 556
FACTORS AFFECTING THE DURABILITY OF PRIMARY TOTAL KNEE PROSTHESES
RAND, J. A., TROUSDALE, R. T., ILSTRUP, D. M., & HARMSEN, W. S. (2003) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200302000-00012 · Cited by 471
Self-citationMatziolis, G., Krocker, D., Weiss, U., Tohtz, S., & Perka, C. (2007) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200702000-00002 · Cited by 429
Navigated Total Knee Replacement: A Meta-Analysis
Bauwens, K., Matthes, G., Wich, M., Gebhard, F., Hanson, B., Ekkernkamp, A., & Stengel, D. (2007) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200702000-00005 · Cited by 399
Cited by
Bellemans, J., Colyn, W., Vandenneucker, H., & Victor, J. (2012) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-011-1936-5 · Cited by 1,085
Howell, S. M., Howell, S. J., Kuznik, K. T., Cohen, J., & Hull, M. L. (2013) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-012-2613-z · Cited by 495
Alignment options for total knee arthroplasty: A systematic review
Rivière, C., Iranpour, F., Auvinet, E., Howell, S., Vendittoli, P.-A., Cobb, J., & Parratte, S. (2017) · Orthopaedics & Traumatology: Surgery & Research · doi:10.1016/j.otsr.2017.07.010 · Cited by 463
Self-citationSong, E.-K., Seon, J.-K., Yim, J.-H., Netravali, N. A., & Bargar, W. L. (2013) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-012-2407-3 · Cited by 447
Why Are Total Knees Failing Today? Etiology of Total Knee Revision in 2010 and 2011
Schroer, W. C., Berend, K. R., Lombardi, A. V., Barnes, C. L., Bolognesi, M. P., Berend, M. E., Ritter, M. A., & Nunley, R. M. (2013) · The Journal of Arthroplasty · doi:10.1016/j.arth.2013.04.056 · Cited by 423
Kim, Y.-H., Park, J.-W., Kim, J.-S., & Park, S.-D. (2014) · International Orthopaedics · doi:10.1007/s00264-013-2097-9 · Cited by 367
Howell, S. M., Papadopoulos, S., Kuznik, K. T., & Hull, M. L. (2013) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-013-2621-x · Cited by 366
Kayani, B., Konan, S., Huq, S. S., Tahmassebi, J., & Haddad, F. S. (2019) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-018-5138-5 · Cited by 338
Vanlommel, L., Vanlommel, J., Claes, S., & Bellemans, J. (2013) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-013-2481-4 · Cited by 322
Bonner, T. J., Eardley, W. G. P., Patterson, P., & Gregg, P. J. (2011) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.93b9.26573 · Cited by 302
Almaawi, A. M., Hutt, J. R. B., Masse, V., Lavigne, M., & Vendittoli, P.-A. (2017) · The Journal of Arthroplasty · doi:10.1016/j.arth.2017.02.028 · Cited by 302
Implant Survival and Function Ten Years After Kinematically Aligned Total Knee Arthroplasty
Howell, S. M., Shelton, T. J., & Hull, M. L. (2018) · The Journal of Arthroplasty · doi:10.1016/j.arth.2018.07.020 · Cited by 302
Mechanical, Anatomical, and Kinematic Axis in TKA: Concepts and Practical Applications
Cherian, J. J., Kapadia, B. H., Banerjee, S., Jauregui, J. J., Issa, K., & Mont, M. A. (2014) · Current Reviews in Musculoskeletal Medicine · doi:10.1007/s12178-014-9218-y · Cited by 274
de Steiger, R. N., Liu, Y.-L., & Graves, S. E. (2015) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.m.01496 · Cited by 267
Young, S. W., Walker, M. L., Bayan, A., Briant-Evans, T., Pavlou, P., & Farrington, B. (2017) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-016-4844-x · Cited by 256
Calliess, T., Bauer, K., Stukenborg-Colsman, C., Windhagen, H., Budde, S., & Ettinger, M. (2017) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-016-4136-8 · Cited by 245
Impact of Component Alignment and Soft Tissue Release on 2-Year Outcomes in Total Knee Arthroplasty
Vigdorchik, J. M., Wakelin, E. A., Koenig, J. A., Ponder, C. E., Plaskos, C., DeClaire, J. H., Lawrence, J. M., & Keggi, J. M. (2022) · The Journal of Arthroplasty · doi:10.1016/j.arth.2022.04.042 · Cited by 65
Kinematically Aligned Total Knee Arthroplasty with Patient-Specific Instrument
Kim, K.-K., Howell, S. M., & Won, Y.-Y. (2020) · Yonsei Medical Journal · doi:10.3349/ymj.2020.61.3.201 · Cited by 23
Computer Assisted Knee Replacement Surgery: Is the Movement Mainstream?
Picard, F. (2014) · Orthopedic & Muscular System · doi:10.4172/2161-0533.1000153 · Cited by 23
Jenny, J., & Baldairon, F. (2023) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-022-07157-2 · Cited by 9
Metadata
- Authors
- Parratte, S., Pagnano, M. W., Trousdale, R. T., & Berry, D. J.
- Venue
- The Journal of Bone and Joint Surgery-American Volume
- Published
- 2010-09
- Volume
- 92
- Issue
- 12
- Pages
- 2143-2149
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W2020842346
- Cited by
- 808
- References
- 17
- FWCI
- 36.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.