Dynamic Contrast Enhanced Magnetic Resonance Imaging in Oncology:Theory, Data Acquisition,Analysis, and Examples
Open accessThe DOI matches its Crossref record; 70 of the 70 references it cites were found in a registry or an index.
Abstract
Dynamic contrast enhanced MRI (DCE-MRI) enables the quantitative assessment of tumor status and has found application in both pre-clinical tumor models as well as clinical oncology. DCE-MRI requires the serial acquisition of images before and after the injection of a paramagnetic contrast agent so that the variation of MR signal intensity with time can be recorded for each image voxel. As the agent enters into a tissue, it changes the MR signal intensity from the tissue to a degree that depends on the local concentration. After the agent is transported out of the tissue, the MR signal intensity returns to its' baseline value. By analyzing the associated signal intensity time course using an appropriate mathematical model, physiological parameters related to blood flow, vessel permeability, and tissue volume fractions can be extracted for each voxel or region of interest.In this review we first discuss the basic physics of this methodology, and then present technical aspects of how DCE-MRI data are acquired and analyzed. We also discuss appropriate models of contrast agent kinetics and how these can be used to elucidate tissue characteristics of importance in cancer biology. We conclude by briefly summarizing some future goals and demands of DCE-MRI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Angiogenesis in cancer and other diseases
Carmeliet, P., & Jain, R. K. (2000) · Nature · doi:10.1038/35025220 · Cited by 9,070 · cited 1×
“It is believed that virtually all solid tumors are dependent upon angiogenesis for survival [5], and many anti-angiogenic drugs are currently in clinical trials [6].”
BackgroundAngiogenesis in cancer, vascular, rheumatoid and other disease
Folkman, J. (1995) · Nature Medicine · doi:10.1038/nm0195-27 · Cited by 7,627 · cited 1×
“This process of neovas-cularization or angiogenesis [3] is a signature of neoplasms and one of the principal potential targets for quantitative imaging [4].”
BackgroundGadolinium(III) Chelates as MRI Contrast Agents: Structure, Dynamics, and Applications
Caravan, P., Ellison, J. J., McMurry, T. J., & Lauffer, R. B. (1999) · Chemical Reviews · doi:10.1021/cr980440x · Cited by 4,483
Tofts, P. S., Brix, G., Buckley, D. L., Evelhoch, J. L., Henderson, E., Knopp, M. V., Larsson, H. B. W., Lee, T.-Y., Mayr, N. A., Parker, G. J. M., et al. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199909)10:3<223::aid-jmri2>3.0.co;2-s · Cited by 3,143
Role of angiogenesis in tumor growth and metastasis
FOLKMAN, J. (2002) · Seminars in Oncology · doi:10.1016/s0093-7754(02)70065-1 · Cited by 2,400
THE THEORY AND APPLICATIONS OF THE EXCHANGE OF INERT GAS AT THE LUNGS AND TISSUES
KETY, S. S. (1951) · Pharmacological Reviews · doi:10.1016/s0031-6997(25)07246-1 · Cited by 1,663
Tofts, P. S., & Kermode, A. G. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170208 · Cited by 1,456
Wedge, S. R., Ogilvie, D., Dukes, M., Kendrew, J., Chester, R., Jackson, J. A., Boffey, S. J., Valentine, P. J., Curwen, J., Musgrove, H. L., et al. (2002) · PubMed · Cited by 798
Parker, G. J. M., Roberts, C., Macdonald, A., Buonaccorsi, G. A., Cheung, S., Buckley, D. L., Jackson, A., Watson, Y., Davies, K., & Jayson, G. C. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21066 · Cited by 660
Pharmacokinetic Parameters in CNS Gd-DTPA Enhanced MR Imaging
Brix, G., Semmler, W., Port, R., Schad, L. R., Layer, G., & Lorenz, W. J. (1991) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199107000-00018 · Cited by 659
Pharmacokinetics of GdDTPA/dimeglumine after intravenous injection into healthy volunteers.
Weinmann, H., Laniado, M., & Mutzel, W. (1984) · PubMed · Cited by 610
SU6668 is a potent antiangiogenic and antitumor agent that induces regression of established tumors.
Laird, A., Vajkoczy, P., Shawver, L. K., Thurnher, A., Liang, C., Mohammadi, M., Schlessinger, J., Ullrich, A., Hubbard, S. R., Blake, R. A., et al. (2000) · PubMed · Cited by 537
Wedam, S. B., Low, J. A., Yang, S. X., Chow, C. K., Choyke, P., Danforth, D., Hewitt, S. M., Berman, A., Steinberg, S. M., Liewehr, D. J., et al. (2006) · Journal of Clinical Oncology · doi:10.1200/jco.2005.03.4645 · Cited by 518
Leach, M. O., Brindle, K. M., Evelhoch, J. L., Griffiths, J. R., Horsman, M. R., Jackson, A., Jayson, G. C., Judson, I. R., Knopp, M. V., Maxwell, R. J., et al. (2005) · British Journal of Cancer · doi:10.1038/sj.bjc.6602550 · Cited by 513
Comparison of Methods for Analysis of Clinical [11C]Raclopride Studies
Lammertsma, A. A., Bench, C. J., Hume, S. P., Osman, S., Gunn, K., Brooks, D. J., & Frackowiak, R. S. J. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199601000-00005 · Cited by 459
Larsson, H. B. W., Stubgaard, M., Frederiksen, J. L., Jensen, M., Henriksen, O., & Paulson, O. B. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160111 · Cited by 431
Studies of Gd‐DTPA relaxivity and proton exchange rates in tissue
Donahue, K. M., Burstein, D., Manning, W. J., & Gray, M. L. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320110 · Cited by 339
Galbraith, S. M., Lodge, M. A., Taylor, N. J., Rustin, G. J. S., Bentzen, S., Stirling, J. J., & Padhani, A. R. (2002) · NMR in Biomedicine · doi:10.1002/nbm.731 · Cited by 338
Safety of magnetic resonance imaging contrast agents
Shellock, F. G., & Kanal, E. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199909)10:3<477::aid-jmri33>3.0.co;2-e · Cited by 321
Yankeelov, T. E., Lepage, M., Chakravarthy, A., Broome, E. E., Niermann, K. J., Kelley, M. C., Meszoely, I., Mayer, I. A., Herman, C. R., McManus, K., et al. (2007) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2006.09.006 · Cited by 314
Self-citationStevenson, J. P., Rosen, M., Sun, W., Gallagher, M., Haller, D. G., Vaughn, D., Giantonio, B., Zimmer, R., Petros, W. P., Stratford, M., et al. (2003) · Journal of Clinical Oncology · doi:10.1200/jco.2003.12.986 · Cited by 291
Daldrup, H., Shames, D. M., Wendland, M., Okuhata, Y., Link, T. M., Rosenau, W., Lu, Y., & Brasch, R. C. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.171.4.9762973 · Cited by 268
Temporal sampling requirements for the tracer kinetics modeling of breast disease
Henderson, E., Rutt, B. K., & Lee, T.-Y. (1998) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(98)00130-1 · Cited by 263
Gd-DTPA relaxivity depends on macromolecular content
Stanisz, G. J., & Henkelman, R. M. (2000) · Magnetic Resonance in Medicine · Cited by 240
ZD6126: a novel vascular-targeting agent that causes selective destruction of tumor vasculature.
Davis, P. D., Dougherty, G. J., Blakey, D. C., Galbraith, S. M., Tozer, G. M., Holder, A. L., Naylor, M. A., Nolan, J., Stratford, M. R. L., Chaplin, D. J., et al. (2002) · PubMed · Cited by 231
MR imaging of tumor microcirculation: Promise for the new millenium
Taylor, J. S., Tofts, P. S., Port, R., Evelhoch, J. L., Knopp, M., Reddick, W. E., Runge, V. M., & Mayr, N. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199912)10:6<903::aid-jmri1>3.0.co;2-a · Cited by 223
Equilibrium transcytolemmal water-exchange kinetics in skeletal muscle in vivo
Landis, C. S., Li, X., Telang, F., Molina, P. E., Pályka, I., Vétek, G., & SPRINGER, C. S. J. (1999) · Magnetic Resonance in Medicine · Cited by 221
Breast MRI for monitoring response of primary breast cancer to neo-adjuvant chemotherapy
Rieber, A., Brambs, H.-J., Gabelmann, A., Heilmann, V., Kreienberg, R., & Kühn, T. (2002) · European Radiology · doi:10.1007/s00330-001-1233-x · Cited by 217
In vivo and in vitro evaluation of combretastatin A-4 and its sodium phosphate prodrug
Grosios, K., Holwell, S. E., McGown, A. T., Pettit, G. R., & Bibby, M. C. (1999) · British Journal of Cancer · doi:10.1038/sj.bjc.6692174 · Cited by 213
Chen, W., Giger, M. L., Bick, U., & Newstead, G. M. (2006) · Medical Physics · doi:10.1118/1.2210568 · Cited by 211
Parkes, L. M., & Tofts, P. S. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10180 · Cited by 202
Antitumor activity of the novel vascular targeting agent ZD6126 in a panel of tumor models.
Blakey, D. C., Westwood, F. R., Walker, M., Hughes, G. D., Davis, P. D., Ashton, S., & Ryan, A. J. (2002) · PubMed · Cited by 190
Reproducibility of quantitative dynamic MRI of normal human tissues
Padhani, A. R., Hayes, C., Landau, S., & Leach, M. O. (2002) · NMR in Biomedicine · doi:10.1002/nbm.732 · Cited by 188
Computerized interpretation of breast MRI: Investigation of enhancement‐variance dynamics
Chen, W., Giger, M. L., Lan, L., & Bick, U. (2004) · Medical Physics · doi:10.1118/1.1695652 · Cited by 186
Port, R. E., Knopp, M. V., Hoffmann, U., Milker-Zabel, S., & Brix, G. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199909)10:3<233::aid-jmri3>3.0.co;2-m · Cited by 175
Anginex, a designed peptide that inhibits angiogenesis
Griffioen, A. W., van der Schaft, D. W. J., Barendsz-Janson, A. F., Andrew, C. O. X., Struijker-Boudier, H. A. J., Hillen, H. F. P., & Mayo, K. H. (2001) · Biochemical Journal · doi:10.1042/0264-6021:3540233 · Cited by 175
Shames, D. M., Kuwatsuru, R., Vexler, V., Mühler, A., & Brasch, R. C. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290506 · Cited by 172
Li, X., Rooney, W. D., & SPRINGER, C. S. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20684 · Cited by 170
Donahue, K. M., Weisskoff, R. M., Chesler, D. A., Kwong, K. K., Bogdanov, A. A., Mandeville, J. B., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360608 · Cited by 165
Roberts, C., Issa, B., Stone, A., Jackson, A., Waterton, J. C., & Parker, G. J. M. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20529 · Cited by 162
Iyer, S., Chaplin, D. J., Rosenthal, D. S., Boulares, A. H., Li, L. Y., & Smulson, M. E. (1998) · PubMed · Cited by 159
Su, M., Cheung, Y., Fruehauf, J. P., Yu, H. J., Nalcioğlu, O., Mechetner, E. B., Kyshtoobayeva, A. S., Chen, S., Hsueh, S., McLaren, C. E., et al. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10380 · Cited by 155
Goßmann, A., Helbich, T. H., Kuriyama, N., Ostrowitzki, S., Roberts, T. P. L., Shames, D. M., van Bruggen, N., Wendland, M. F., Israel, M. A., & Brasch, R. C. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10072 · Cited by 151
Kovar, D. A., Lewis, M. Z., & Karczmar, G. S. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080519 · Cited by 149
A fast 3D Look-Locker method for volumetric T1 mapping
Henderson, E., McKinnon, G. C., Lee, T.-Y., & Rutt, B. K. (1999) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(99)00025-9 · Cited by 144
Applications of Magnetic Resonance in Model Systems: Cancer Therapeutics
Evelhoch, J. L., Gillies, R. J., Karczmar, G. S., Koutcher, J. A., Maxwell, R. J., Nalcioğlu, O., Raghunand, N., Ronen, S. M., Ross, B. D., & Swartz, H. M. (2000) · Neoplasia · doi:10.1038/sj.neo.7900078 · Cited by 141
Walker‐Samuel, S., Leach, M. O., & Collins, D. J. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/14/021 · Cited by 134
Laird, A. D., Christensen, J. G., Li, G., Carver, J., Smith, K., Xin, X., Moss, K. G., Louie, S. G., Mendel, D. B., & Cherrington, J. M. (2002) · The FASEB Journal · doi:10.1096/fj.01-0700com · Cited by 131
Checkley, D., Tessier, J. J. L., Kendrew, J., Waterton, J. C., & Wedge, S. R. (2003) · British Journal of Cancer · doi:10.1038/sj.bjc.6601386 · Cited by 128
Applications of Magnetic Resonance in Model Systems: Tumor Biology and Physiology
Gillies, R. J., Bhujwalla, Z. M., Evelhoch, J. L., Garwood, M., Neeman, M., Robinson, S. P., Sotak, C. H., & van der Sanden, B. P. J. (2000) · Neoplasia · doi:10.1038/sj.neo.7900076 · Cited by 125
The discovery of angiogenic factors:
Ribatti, D., Vacca, A., & Presta, M. (2000) · General Pharmacology The Vascular System · doi:10.1016/s0306-3623(01)00112-4 · Cited by 122
Parker, G. J. M., Barker, G. J., & Tofts, P. S. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1112 · Cited by 112
Tumour dose response to the antivascular agent ZD6126 assessed by magnetic resonance imaging
Robinson, S. P., McIntyre, D. J. O., Checkley, D., Tessier, J. J. L., Howe, F. A., Griffiths, J. R., Ashton, S., Ryan, A. J., Blakey, D. C., & Waterton, J. C. (2003) · British Journal of Cancer · doi:10.1038/sj.bjc.6600926 · Cited by 109
New Technologies and Directed Agents for Applications of Cancer Imaging
Atri, M. (2006) · Journal of Clinical Oncology · doi:10.1200/jco.2006.06.6159 · Cited by 108
Warren, R. M. L., Pointon, L. J., Thompson, D. J., Hoff, R., Gilbert, F. J., Padhani, A. R., Easton, D. F., Lakhani, S. R., & Leach, M. O. (2005) · Radiology · doi:10.1148/radiol.2363040735 · Cited by 107
Dings, R. P. M., Yokoyama, Y., Ramakrishnan, S., Griffioen, A. W., & Mayo, K. H. (2003) · PubMed · Cited by 107
Yankeelov, T. E., Cron, G. O., Addison, C., Wallace, J. C., Wilkins, R. C., Pappas, B. A., Santyr, G. E., & Gore, J. C. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21131 · Cited by 102
Self-citationZhou, R., Pickup, S., Yankeelov, T. E., SPRINGER, C. S. J., & Glickson, J. D. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20143 · Cited by 98
Self-citationFast high‐resolution T 1 mapping of the human brain
Deichmann, R. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20552 · Cited by 96
Schwarzbauer, C., Morrissey, S. P., Deichmann, R., Hillenbrand, C., Syha, J., Adolf, H., Nöth, U., & Haase, A. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370521 · Cited by 92
Dynamic Contrast-Enhanced MRI of Malignant Pleural Mesothelioma
Giesel, F. L., Bischoff, H. G., von Tengg‐Kobligk, H., Weber, M., Zechmann, C. M., Kauczor, H., & Knopp, M. V. (2006) · CHEST Journal · doi:10.1378/chest.129.6.1570 · Cited by 92
Daldrup-Link, H. E., Shames, D. M., Wendland, M. F., Okuhata, Y., Link, T. M., Rosenau, W., Lü, Y., & Brasch, R. C. (1998) · Pediatric Radiology · doi:10.1007/s002470050296 · Cited by 91
Chang, Y., Huang, C., Liu, Y., Chen, J., Lu, Y., & Tseng, W. I. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/16/007 · Cited by 79
Zhu, D. C., & Penn, R. D. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20602 · Cited by 78
Repeatability of a reference region model for analysis of murine DCE‐MRI data at 7T
Yankeelov, T. E., DeBusk, L. M., Billheimer, D. D., Luci, J. J., Lin, P. C., Price, R. R., & Gore, J. C. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20729 · Cited by 66
Self-citationCritical role of spatial resolution in dynamic contrast‐enhanced breast MRI
Furman‐Haran, E., Grobgeld, D., Kelcz, F., & Degani, H. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1123 · Cited by 58
Lyng, H., Dahle, G. A., Kaalhus, O., Skretting, A., & Rofstad, E. K. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400113 · Cited by 41
Cao, Y., Brown, S. L., Knight, R. A., Fenstermacher, J. D., & Ewing, J. R. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20340 · Cited by 37
TNP-470 promotes initial vascular sprouting in xenograft tumors
Huang, J., Frischer, J. S., New, T. N., Kim, E. S., Serur, A., Lee, A., Kadenhe, A., Pollyea, D. A., Yokoi, A., Holash, J. A., et al. (2004) · Molecular Cancer Therapeutics · doi:10.1158/1535-7163.335.3.3 · Cited by 26
Rouvière, O., Reynolds, C. A., Le, Y., Lai, J., Roberts, L. R., Felmlee, J. P., & Ehman, R. L. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20466 · Cited by 15
Cited by
Metabolic heterogeneity in human lung tumors
Hensley, C. T., Faubert, B., Yuan, Q., Lev-Cohain, N., Jin, E., Kim, J., Jiang, L., Ko, B., Skelton, R., Loudat, L., et al. (2016) · Cell · doi:10.1016/j.cell.2015.12.034 · Cited by 1,138
Perfusion MRI: The Five Most Frequently Asked Clinical Questions
Essig, M., Nguyen, T. B., Shiroishi, M. S., Saake, M., Provenzale, J. M., Enterline, D. S., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9544 · Cited by 344
Models and methods for analyzing DCE‐MRI: A review
Khalifa, F., Soliman, A., El‐Baz, A., Abou El‐Ghar, M., El‐Diasty, T., Gimel'farb, G., Ouseph, R., & Dwyer, A. C. (2014) · Medical Physics · doi:10.1118/1.4898202 · Cited by 322
Imaging Neoadjuvant Therapy Response in Breast Cancer
Fowler, A. M., Mankoff, D. A., & Joe, B. N. (2017) · Radiology · doi:10.1148/radiol.2017170180 · Cited by 242
Wu, J., Cao, G., Sun, X., Lee, J., Rubin, D. L., Napel, S., Kurian, A. W., Daniel, B. L., & Li, R. (2018) · Radiology · doi:10.1148/radiol.2018172462 · Cited by 216
“First, at the individual level, each tumor is oversegmented into many small contiguous regions (ie, superpixels) that contain similar voxels as defined by four kinetic maps at dynamic contrast material–enhanced (DCE) MR imaging: percentage enhancement, signal enhancement ratio, and wash-in and washout slopes (9,18,19)…”
Background
Metadata
- Authors
- Yankeelov, T., & Gore, J.
- Venue
- Current Medical Imaging Reviews
- Publisher
- Bentham Science Publishers Ltd.
- Published
- 2007-05-01
- Volume
- 3
- Issue
- 2
- Pages
- 91-107
- ISSN
- 1573-4056 (ISSN-L)
- OpenAlex
- W2091633428
- Cited by
- 398
- References
- 70
- FWCI
- 5.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.