An Integrated Brain-Machine Interface Platform With Thousands of Channels
Open accessPublished version of a preprint
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Brain-machine interfaces hold promise for the restoration of sensory and motor function and the treatment of neurological disorders, but clinical brain-machine interfaces have not yet been widely adopted, in part, because modest channel counts have limited their potential. In this white paper, we describe Neuralink’s first steps toward a scalable high-bandwidth brain-machine interface system. We have built arrays of small and flexible electrode “threads,” with as many as 3072 electrodes per array distributed across 96 threads. We have also built a neurosurgical robot capable of inserting six threads (192 electrodes) per minute. Each thread can be individually inserted into the brain with micron precision for avoidance of surface vasculature and targeting specific brain regions. The electrode array is packaged into a small implantable device that contains custom chips for low-power on-board amplification and digitization: The package for 3072 channels occupies less than 23×18.5×2 mm3. A single USB-C cable provides full-bandwidth data streaming from the device, recording from all channels simultaneously. This system has achieved a spiking yield of up to 70% in chronically implanted electrodes. Neuralink’s approach to brain-machine interface has unprecedented packaging density and scalability in a clinically relevant package.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures







![Figure 8 Our devices allow the recording of widespread neural activity distributed across multiple brain regions and cortical layers. Left: Thread insertion sites (colored circles) are indicated on the rendered rodent brain [38]. Right: Raster of 1020 simultaneously recorded channels, sorted per thread (color corresponds to insertion site). Inset: Enlarged raster of spikes from a single thread. This thread corresponds to the one shown in Figure 7.](https://figures.cochat.ai/paper-figures/e7757d03e8824957a059cbeb552c4b3c/an-integrated-brain-machine-interface-platform-with-thousands-of-channels-figure-8.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“As materials and manufacturing processes evolve, more micro-wires are becoming flexible alternatives to microneedle arrays, which are able to remain relatively stationary as the brain moves, improving signal stability while reducing tissue damage.[339–342]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [341]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In addition, although not ready for chronic implantation, NeuroPixels, or similar probes that sample laminar cortex, may offer a method to record high-density single units across cortical layers in humans187,188.”
From The speech neuroprosthesis (2024) · cites this paper as [187]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“AI-powered brain-computer interfaces such as 'Neuralink' are also being worked on that can august human cognition (Musk and Neuralink, 2020).”
From The impact of digital technology, social media, and artificial intelligence on cognitive functions: a review (2023) · cites this paper as Musk and Neuralink, 2020
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Neuralink designed its system to be both scalable and low-power, incorporating a specialized charger with an aluminum battery base and a detachable remote coil for added charging flexibility (Musk and Neuralink, 2019).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Musk and Neuralink, 2019
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“next-generation recording devices are under development35,36”
From A high-performance speech neuroprosthesis (2023) · cites this paper as [35]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origin of extracellular fields and currents — EEG, ECoG, LFP and spikes
Buzsáki, G., Anastassiou, C. A., & Koch, C. (2012) · Nature Reviews Neuroscience · doi:10.1038/nrn3241 · Cited by 4,225
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Fully integrated silicon probes for high-density recording of neural activity
Jun, J. J., Steinmetz, N. A., Siegle, J. H., Denman, D. J., Bauza, M., Barbarits, B., Lee, A. K., Anastassiou, C. A., Andrei, A., Aydın, Ç., et al. (2017) · Nature · doi:10.1038/nature24636 · Cited by 2,190
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Targeted neurotechnology restores walking in humans with spinal cord injury
Wagner, F. B., Mignardot, J.-B., Le Goff-Mignardot, C. G., Demesmaeker, R., Komi, S., Capogrosso, M., Rowald, A., Seáñez, I., Caban, M., Pirondini, E., et al. (2018) · Nature · doi:10.1038/s41586-018-0649-2 · Cited by 1,087
NeuroGrid: recording action potentials from the surface of the brain
Khodagholy, D., Gelinas, J. N., Thesen, T., Doyle, W., Devinsky, O., Malliaras, G. G., & Buzsáki, G. (2015) · Nature Neuroscience · doi:10.1038/nn.3905 · Cited by 938
Speech synthesis from neural decoding of spoken sentences
Anumanchipalli, G. K., Chartier, J., & Chang, E. F. (2019) · Nature · doi:10.1038/s41586-019-1119-1 · Cited by 883
From the neuron doctrine to neural networks
Yuste, R. (2015) · Nature Reviews Neuroscience · doi:10.1038/nrn3962 · Cited by 754
Chronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740
Novel electrode technologies for neural recordings
Hong, G., & Lieber, C. M. (2019) · Nature Reviews Neuroscience · doi:10.1038/s41583-019-0140-6 · Cited by 695
Syringe-injectable electronics
Liu, J., Fu, T.-M., Cheng, Z., Hong, G., Zhou, T., Jin, L., Duvvuri, M., Jiang, Z., Kruskal, P., Xie, C., et al. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.115 · Cited by 687
Decoding motor imagery from the posterior parietal cortex of a tetraplegic human
Aflalo, T., Kellis, S., Klaes, C., Lee, B., Shi, Y., Pejsa, K., Shanfield, K., Hayes-Jackson, S., Aisen, M., Heck, C., et al. (2015) · Science · doi:10.1126/science.aaa5417 · Cited by 649
Maynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640
Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638
Active tactile exploration using a brain–machine–brain interface
O’Doherty, J. E., Lebedev, M. A., Ifft, P. J., Zhuang, K. Z., Shokur, S., Bleuler, H., & Nicolelis, M. A. L. (2011) · Nature · doi:10.1038/nature10489 · Cited by 629
A brain-computer interface that evokes tactile sensations improves robotic arm control
Flesher, S. N., Downey, J. E., Weiss, J. M., Hughes, C. L., Herrera, A. J., Tyler-Kabara, E. C., Boninger, M. L., Collinger, J. L., & Gaunt, R. A. (2021) · Science · doi:10.1126/science.abd0380 · Cited by 617
Ultraflexible nanoelectronic probes form reliable, glial scar–free neural integration
Luan, L., Wei, X., Zhao, Z., Siegel, J. J., Potnis, O., Tuppen, C. A., Lin, S., Kazmi, S., Fowler, R. A., Holloway, S., et al. (2017) · Science Advances · doi:10.1126/sciadv.1601966 · Cited by 612
Open Ephys: an open-source, plugin-based platform for multichannel electrophysiology
Siegle, J. H., López, A. C., Patel, Y. A., Abramov, K., Ohayon, S., & Voigts, J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa5eea · Cited by 545
An Electrocorticographic Brain Interface in an Individual with Tetraplegia
Wang, W., Collinger, J. L., Degenhart, A. D., Tyler-Kabara, E. C., Schwartz, A. B., Moran, D. W., Weber, D. J., Wodlinger, B., Vinjamuri, R. K., Ashmore, R. C., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055344 · Cited by 402
Pesaran, B., Vinck, M., Einevoll, G. T., Sirota, A., Fries, P., Siegel, M., Truccolo, W., Schroeder, C. E., & Srinivasan, R. (2018) · Nature Neuroscience · doi:10.1038/s41593-018-0171-8 · Cited by 370
Chung, J. E., Joo, H. R., Fan, J. L., Liu, D. F., Barnett, A. H., Chen, S., Geaghan-Breiner, C., Karlsson, M. P., Karlsson, M., Lee, K. Y., et al. (2019) · Neuron · doi:10.1016/j.neuron.2018.11.002 · Cited by 342
Microelectrodes, Microelectronics, and Implantable Neural Microsystems
Wise, K. D., Sodagar, A. M., Yao, Y., Gulari, M. N., Perlin, G. E., & Najafi, K. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922564 · Cited by 335
Stable long-term chronic brain mapping at the single-neuron level
Fu, T.-M., Hong, G., Zhou, T., Schuhmann, T. G., Viveros, R. D., & Lieber, C. M. (2016) · Nature Methods · doi:10.1038/nmeth.3969 · Cited by 330
The impact of chronic blood–brain barrier breach on intracortical electrode function
Saxena, T., Karumbaiah, L., Gaupp, E. A., Patkar, R., Patil, K., Betancur, M., Stanley, G. B., & Bellamkonda, R. V. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.03.007 · Cited by 266
Accurate Estimation of Neural Population Dynamics without Spike Sorting
Trautmann, E. M., Stavisky, S. D., Lahiri, S., Ames, K. C., Kaufman, M. T., O’Shea, D. J., Vyas, S., Sun, X., Ryu, S. I., Ganguli, S., et al. (2019) · Neuron · doi:10.1016/j.neuron.2019.05.003 · Cited by 255
Zhou, A., Santacruz, S. R., Johnson, B. C., Alexandrov, G., Moin, A., Burghardt, F. L., Rabaey, J. M., Carmena, J. M., & Muller, R. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0323-x · Cited by 233
A review on mechanical considerations for chronically-implanted neural probes
Lecomte, A., Descamps, E., & Bergaud, C. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8b4f · Cited by 205
Wilks, S. (2009) · Frontiers in Neuroengineering · doi:10.3389/neuro.16.007.2009 · Cited by 188
SiNAPS: An implantable active pixel sensor CMOS-probe for simultaneous large-scale neural recordings
Angotzi, G. N., Boi, F., Lecomte, A., Miele, E., Malerba, M., Zucca, S., Casile, A., & Berdondini, L. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.10.032 · Cited by 177
Sputtered iridium oxide films (SIROFs) for low-impedance neural stimulation and recording electrodes
Cogan, S. F., Plante, T. D., & Ehrlich, J. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1404158 · Cited by 138
Calabrese, E., Badea, A., WATSON, C. R. R., & Johnson, G. A. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.01.017 · Cited by 119
Fluidic Microactuation of Flexible Electrodes for Neural Recording
Vitale, F., Vercosa, D. G., Rodriguez, A. V., Pamulapati, S. S., Seibt, F., Lewis, E., Yan, J. S., Badhiwala, K. N., Adnan, M., Carfagni, G. R., et al. (2017) · Nano Letters · doi:10.1021/acs.nanolett.7b04184 · Cited by 117
To sort or not to sort: the impact of spike-sorting on neural decoding performance
Todorova, S., Sadtler, P. T., Batista, A. P., Chase, S. M., & Ventura, V. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056005 · Cited by 113
Kaiju, T., Keiichi, D., Yokota, M., Watanabe, K., Inoue, M., Ando, H., Takahashi, K., Yoshida, F., Hirata, M., & Suzuki, T. (2017) · Frontiers in Neural Circuits · doi:10.3389/fncir.2017.00020 · Cited by 105
Christie, B. P., Tat, D. M., Irwin, Z. T., Gilja, V., Nuyujukian, P., Foster, J. D., Ryu, S. I., Shenoy, K. V., Thompson, D. E., & Chestek, C. A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016009 · Cited by 103
Amorphous silicon carbide ultramicroelectrode arrays for neural stimulation and recording
Deku, F., Cohen, Y., Joshi-Imre, A., Kanneganti, A., Gardner, T. J., & Cogan, S. F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8f8b · Cited by 89
The “sewing machine” for minimally invasive neural recordingPreprint
Hanson, T., Diaz-Botia, C. A., Kharazia, V., Maharbiz, M. M., & Sabes, P. N. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/578542 · Cited by 80
A Large-Scale Semi-Chronic Microdrive Recording System for Non-Human Primates
Dotson, N. M., Hoffman, S. J., Goodell, B., & Gray, C. M. (2017) · Neuron · doi:10.1016/j.neuron.2017.09.050 · Cited by 70
Morphology and charge capacity of sputtered iridium oxide films
Klein, J. D., Clauson, S. L., & Cogan, S. F. (1989) · Journal of Vacuum Science & Technology A Vacuum Surfaces and Films · doi:10.1116/1.576313 · Cited by 63
A sweet new multiple electrode for chronic single unit recording in moving animals
Chorover, S. L., & DeLuca, A. M. (1972) · Physiology & Behavior · doi:10.1016/0031-9384(72)90030-3 · Cited by 53
NeuroRoots, a bio-inspired, seamless Brain Machine Interface device for long-term recordingPreprint
Ferro, M. D., Proctor, C. M., Gonzalez, A., Zhao, E. T., Slézia, A., Pas, J., Dijk, G., Donahue, M. J., Williamson, A., Malliaras, G. G., et al. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/460949 · Cited by 32
Research works printed but not linked: 2
- TimothyLHBioRxiv20192019-09-11The “sewing machine” for minimally invasive neural recordinghttps://www.biorxiv.org/content/biorxiv/early/2019/03/14/578542.full.pdf
- SharleneNFBioRxiv20192019-09-11Restored tactile sensation improves neuroprosthetic arm control?https://www.biorxiv.org/content/biorxiv/early/2019/05/31/653428.full.pdf
Cited by
The rise of artificial intelligence in healthcare applications
Bohr, A., & Memarzadeh, K. (2020) · Artificial Intelligence in Healthcare · doi:10.1016/b978-0-12-818438-7.00002-2 · Cited by 1,636
Neuropixels 2.0: A miniaturized high-density probe for stable, long-term brain recordings.
Steinmetz, N. A., Aydin, C., Lebedeva, A., Okun, M., Pachitariu, M., Bauza, M., Beau, M., Bhagat, J., Böhm, C., Broux, M., et al. (2021) · Science · doi:10.1126/science.abf4588 · Cited by 1,173
High-performance brain-to-text communication via handwriting
Willett, F. R., Avansino, D. T., Hochberg, L. R., Henderson, J. M., & Shenoy, K. V. (2021) · Nature · doi:10.1038/s41586-021-03506-2 · Cited by 1,024
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
A high-performance speech neuroprosthesis
Willett, F. R., Kunz, E. M., Fan, C., Avansino, D. T., Wilson, G. H., Choi, E. Y., Kamdar, F., Glasser, M. F., Hochberg, L. R., Druckmann, S., et al. (2023) · Nature · doi:10.1038/s41586-023-06377-x · Cited by 581
Metadata
- Authors
- Musk, E., & Neuralink
- Corresponding author
- Musk, Elon
- ORCID
- Musk, Elon
- Venue
- Journal of Medical Internet Research
- Publisher
- JMIR Publications Inc.
- Published
- 2019-10-31
- Volume
- 21
- Issue
- 10
- Pages
- e16194
- ISSN
- 1438-8871 (ISSN-L)
- PMC
- PMC6914248
- OpenAlex
- W2980609230
- Cited by
- 1,206
- References
- 42
- Citations by year
- 2026: 124 · 2025: 221 · 2024: 184 · 2023: 172 · 2022: 149 · 2021: 211 · 2020: 116 · 2019: 25
- FWCI
- 59.63
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- other-oa
- Locations
- Journal of Medical Internet Research (publishedVersion, other-oa)
- bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion, cc-by-nd)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nd)
- PubMed Central (publishedVersion, cc-by-nd)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Institute of Neurological Disorders and Stroke (R01NS089679)
- Lawrence Livermore National Laboratory
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- brain-computer interface, high-density electrode arrays, neurosurgical robot, chronic neural recording, stream processing, Neuralink
- MeSH terms
- Humans, Sensation, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.