Abstract

Background: Automated insulin delivery (AID) systems have been shown to be safe and effective in reducing hyperglycemia and hypoglycemia but are not universally available, accessible, or affordable. Therefore, user-driven open-source AID systems are becoming increasingly popular. Objective: This study aims to investigate the motivations for which people with diabetes (types 1, 2, and other) or their caregivers decide to build and use a personalized open-source AID. Methods: A cross-sectional web-based survey was conducted to assess personal motivations and associated self-reported clinical outcomes. Results: Of 897 participants from 35 countries, 80.5% (722) were adults with diabetes and 19.5% (175) were caregivers of children with diabetes. Primary motivations to commence open-source AID included improving glycemic outcomes (476/509 adults, 93.5%, and 95/100 caregivers, 95%), reducing acute (443/508 adults, 87.2%, and 96/100 caregivers, 96%) and long-term (421/505 adults, 83.3%, and 91/100 caregivers, 91%) complication risk, interacting less frequently with diabetes technology (413/509 adults, 81.1%; 86/100 caregivers, 86%), improving their or child’s sleep quality (364/508 adults, 71.6%, and 80/100 caregivers, 80%), increasing their or child’s life expectancy (381/507 adults, 75.1%, and 84/100 caregivers, 84%), lack of commercially available AID systems (359/507 adults, 70.8%, and 79/99 caregivers, 80%), and unachieved therapy goals with available therapy options (348/509 adults, 68.4%, and 69/100 caregivers, 69%). Improving their own sleep quality was an almost universal motivator for caregivers (94/100, 94%). Significant improvements, independent of age and gender, were observed in self-reported glycated hemoglobin (HbA1c), 7.14% (SD 1.13%; 54.5 mmol/mol, SD 12.4) to 6.24% (SD 0.64%; 44.7 mmol/mol, SD 7.0; P<.001), and time in range (62.96%, SD 16.18%, to 80.34%, SD 9.41%; P<.001). Conclusions: These results highlight the unmet needs of people with diabetes, provide new insights into the evolving phenomenon of open-source AID technology, and indicate improved clinical outcomes. This study may inform health care professionals and policy makers about the opportunities provided by open-source AID systems. International Registered Report Identifier (IRRID): RR2-10.2196/15368

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2196/25409

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Motivations for building an open-source automated insulin delivery system. The x-axis shows the percentage of responses for each motivation question (y-axis). Bar colors represent the degree of relevance ranging from “does not apply at all” to “fully applies.” The left and right columns show the responses of caregivers of children with diabetes and adults with diabetes, respectively. Responses are ranked from the most frequently endorsed motivations (top) to the less frequently endorsed (bottom).
Figure 1 Motivations for building an open-source automated insulin delivery system. The x-axis shows the percentage of responses for each motivation question (y-axis). Bar colors represent the degree of relevance ranging from “does not apply at all” to “fully applies.” The left and right columns show the responses of caregivers of children with diabetes and adults with diabetes, respectively. Responses are ranked from the most frequently endorsed motivations (top) to the less frequently endorsed (bottom).CC BY · PubMed Central
Figure 2 Positive effects of open-source automated insulin delivery on clinical outcomes: average self-reported glycated hemoglobin (%; y-axis) for all 310 respondents, before and after open-source automated insulin delivery (x-axis) distinguished by orange and green colors, respectively. The left side is displayed as a density plot, with horizontal lines indicating quartiles. The right side depicts the data as a scatter plot. DIYAPS: Do-it-Yourself Artificial Pancreas System; HbA1c: glycated hemoglobin.
Figure 2 Positive effects of open-source automated insulin delivery on clinical outcomes: average self-reported glycated hemoglobin (%; y-axis) for all 310 respondents, before and after open-source automated insulin delivery (x-axis) distinguished by orange and green colors, respectively. The left side is displayed as a density plot, with horizontal lines indicating quartiles. The right side depicts the data as a scatter plot. DIYAPS: Do-it-Yourself Artificial Pancreas System; HbA1c: glycated hemoglobin.CC BY · PubMed Central
Figure 3 Self-reported time in range (%; x-axis) of adults and children with diabetes, before and after implementing an open-source automated insulin delivery system. The left side is displayed as a density plot, with horizontal lines indicating quartiles. The right side depicts the data as a scatter plot.
Figure 3 Self-reported time in range (%; x-axis) of adults and children with diabetes, before and after implementing an open-source automated insulin delivery system. The left side is displayed as a density plot, with horizontal lines indicating quartiles. The right side depicts the data as a scatter plot.CC BY · PubMed Central
Figure 4 Improvements in self-reported glycated hemoglobin levels associated with open-source automated insulin delivery, independent of age or gender: relation between average glycated hemoglobin levels (%; y-axis) and age (x-axis), shown separately for female and male respondents (top and bottom rows, respectively). Colors separate average glycated levels before (orange) and after (green) open-source automated insulin delivery implementation. Each point represents one respondent after filtering of responses (the Methods section). Solid lines and their gray areas represent the trend and standard error for the respective groups. AID: automated insulin delivery; HbA1c: glycated hemoglobin.
Figure 4 Improvements in self-reported glycated hemoglobin levels associated with open-source automated insulin delivery, independent of age or gender: relation between average glycated hemoglobin levels (%; y-axis) and age (x-axis), shown separately for female and male respondents (top and bottom rows, respectively). Colors separate average glycated levels before (orange) and after (green) open-source automated insulin delivery implementation. Each point represents one respondent after filtering of responses (the Methods section). Solid lines and their gray areas represent the trend and standard error for the respective groups. AID: automated insulin delivery; HbA1c: glycated hemoglobin.CC BY · PubMed Central
Figure 5 Improvements in self-reported glycated hemoglobin levels associated with open-source automated insulin delivery, independent of age or gender: the y-axis shows the difference of average glycated hemoglobin levels after open-source automated insulin delivery, compared with before its implementation. Colors distinguish respondents with reduced average glycated hemoglobin (blue) from those with unchanged or increased glycated hemoglobin (red). AID: automated insulin delivery; HbA1c: glycated hemoglobin.
Figure 5 Improvements in self-reported glycated hemoglobin levels associated with open-source automated insulin delivery, independent of age or gender: the y-axis shows the difference of average glycated hemoglobin levels after open-source automated insulin delivery, compared with before its implementation. Colors distinguish respondents with reduced average glycated hemoglobin (blue) from those with unchanged or increased glycated hemoglobin (red). AID: automated insulin delivery; HbA1c: glycated hemoglobin.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 67

Metadata

Authors
Braune, K., Gajewska, K. A., Thieffry, A., Lewis, D. M., Froment, T., O'Donnell, S., Speight, J., Hendrieckx, C., Schipp, J., Skinner, T., Langstrup, H., Tappe, A., Raile, K., & Cleal, B.
Affiliations
  • Berlin Institute of Health at Charité - Universitätsmedizin Berlin (DE)
  • Royal College of Surgeons in Ireland (IE)
  • Technical University of Denmark (DK)
  • University College Dublin (IE)
  • Deakin University (AU)
  • University of Copenhagen (DK)
  • Charité – Universitätsmedizin Berlin (DE)
  • Steno Diabetes Center Copenhagen (DK)
Corresponding author
Braune, Katarina
Venue
Journal of Medical Internet Research
Published
2021-06-07
Volume
23
Issue
6
Pages
e25409
ISSN
1438-8871 (ISSN-L)
OpenAlex
W3137200532
Cited by
67
References
42
Citations by year
2026: 9 · 2025: 5 · 2024: 15 · 2023: 11 · 2022: 20 · 2021: 7
FWCI
9.89
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • Journal of Medical Internet Research (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Research at the University of Copenhagen (University of Copenhagen) (publishedVersion, cc-by)
  • Refubium (Universitätsbibliothek der Freien Universität Berlin) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Deakin Research Online (Deakin University) (submittedVersion)
  • Figshare (submittedVersion, cc-by)
  • Minerva Access (University of Melbourne) (submittedVersion, cc-by)
  • Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU) (submittedVersion, other-oa)
  • Lenus, The Irish Health Repository (Dr Steevens Hospital Library) (submittedVersion, cc-by)
  • Universitätsbibliothek der FU Berlin Hochschulschriftenstelle u. Dokumentenserver (cc-by)
Funders
  • Wellcome Trust
  • Steno Diabetes Center Copenhagen (SDCC HP 2. A. Diabetes Mgmt Res)
  • European Commission (HORIZON2020, 823902)
  • Deakin University
  • Berlin Institute of Health
  • Diabetes Victoria
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Diabetes and associated disorders
Keywords
artificial pancreas, diabetes self-management, user motivation, glycemic control, HbA1c, sleep quality, pediatric diabetes, diabetes complications, diabetes technology access
MeSH terms
Patient Reported Outcome Measures, Adult, Child, Cross-Sectional Studies, Diabetes Mellitus, Type 1, Humans, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Motivation, Self Report

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.