MR Elastography of Breast Cancer: Preliminary Results
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Motivated by the long-recognized value of palpation in detecting breast cancer, we tested the feasibility of a technique for quantitatively evaluating the mechanical properties of breast tissues on the basis of direct MR imaging visualization of acoustic waves. SUBJECTS AND METHODS: The prototypic elasticity imaging technique consists of a device for generating acoustic shear waves in tissue, an MR imaging-based method for imaging the propagation of these waves, and an algorithm for processing the wave images to generate quantitative images depicting tissue stiffness. After tests with tissue-simulating phantom materials and breast cancer specimens, we used the prototypic breast MR elastography technique to image six healthy women and six patients with known breast cancer. RESULTS: Acoustic shear waves were clearly visualized in phantoms, breast cancer specimens, healthy volunteers, and patients with breast cancer. The elastograms of the tumor specimens showed focal areas of high shear stiffness. MR elastograms of healthy volunteers revealed moderately heterogeneous mechanical properties, with the shear stiffness of fibroglandular tissue measuring slightly higher than that of adipose tissue. The elastograms of patients with breast cancer showed focal areas of high shear stiffness corresponding to the locations of the known tumors. The mean shear stiffness of breast carcinoma was 418% higher than the mean value of surrounding breast tissues. CONCLUSION: The results confirm the hypothesis that the prototypic breast MR elastographic technique can quantitatively depict the elastic properties of breast tissues in vivo and reveal high shear elasticity in known breast tumors. Further research is needed to evaluate the potential applications of MR elastography, such as detecting breast carcinoma and characterizing suspicious breast lesions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Landis, S. H., Murray, T., Bolden, S., & Wingo, P. A. (1999) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.49.1.8 · Cited by 3,068
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116
Self-citationFung, Y.-C. (1993) · Springer eBooks · doi:10.1007/978-1-4757-2257-4 · Cited by 2,051
Elastic Moduli of Breast and Prostate Tissues under Compression
Krouskop, T. A., Wheeler, T. M., Kallel, F., Garra, B. S., & Hall, T. (1998) · Ultrasonic Imaging · doi:10.1177/016173469802000403 · Cited by 1,703
Elastography of breast lesions: initial clinical results.
Garra, B. S., Cespedes, E. I., Ophir, J., Spratt, S. R., Zuurbier, R. A., Magnant, C. M., & Pennanen, M. F. (1997) · Radiology · doi:10.1148/radiology.202.1.8988195 · Cited by 940
Analysis of cancers missed at screening mammography.
Bird, R. E., Wallace, T. W., & Yankaskas, B. C. (1992) · Radiology · doi:10.1148/radiology.184.3.1509041 · Cited by 820
High-resolution tensor MR elastography for breast tumour detection
Sinkus, R., Lorenzen, J., Schrader, D., Lorenzen, M., Dargatz, M., & Holz, D. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/317 · Cited by 481
Boetes, C., Barentsz, J. O., Mus, R. D. M., van der Sluis, R. F., van Erning, L. J. T. O., Hendriks, J. H. C. L., Holland, R., & Ruys, S. H. (1994) · Radiology · doi:10.1148/radiology.193.3.7972823 · Cited by 402
Tissue characterization using magnetic resonance elastography: preliminary results*
Kruse, S. A., Smith, J. A., Lawrence, A. J., Dresner, M. A., Manduca, A., Greenleaf, J. F., Ehman, R. L., Kruse, S. A., Smith, J. A., Lawrence, A. J., et al. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/313 · Cited by 340
Self-citationPlewes, D. B., Bishop, J., Samani, A., & Sciarretta, J. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/314 · Cited by 318
Cited by
Tissue Cells Feel and Respond to the Stiffness of Their Substrate
Discher, D. E., Janmey, P., & Wang, Y.-L. (2005) · Science · doi:10.1126/science.1116995 · Cited by 6,382
Nanomechanical analysis of cells from cancer patients
Cross, S. E., Jin, Y.-S., Rao, J., & Gimzewski, J. K. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.388 · Cited by 1,908
Assessment of Hepatic Fibrosis With Magnetic Resonance Elastography
Yin, M., Talwalkar, J. A., Glaser, K. J., Manduca, A., Grimm, R. C., Rossman, P. J., Fidler, J. L., & Ehman, R. L. (2007) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2007.06.012 · Cited by 948
Self-citationFass, L. (2008) · Molecular Oncology · doi:10.1016/j.molonc.2008.04.001 · Cited by 822
Cell Stiffness Is a Biomarker of the Metastatic Potential of Ovarian Cancer Cells
Xu, W., Mezencev, R., Kim, B., Wang, L., McDonald, J., & Sulchek, T. (2012) · PLoS ONE · doi:10.1371/journal.pone.0046609 · Cited by 760
Samani, A., Zubovits, J., & Plewes, D. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/6/002 · Cited by 707
Magnetic resonance elastography: A review
Mariappan, Y. K., Glaser, K. J., & Ehman, R. L. (2010) · Clinical Anatomy · doi:10.1002/ca.21006 · Cited by 680
Self-citationViscoelastic shear properties of in vivo breast lesions measured by MR elastography
Sinkus, R., Tanter, M., Xydeas, T., Catheline, S., Bercoff, J., & Fink, M. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.11.060 · Cited by 503
Imaging the elastic properties of tissue: the 20 year perspective
Parker, K. J., Doyley, M. M., & Rubens, D. J. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/1/r01 · Cited by 477
AFM-based analysis of human metastatic cancer cells
Cross, S. E., Jin, Y.-S., Tondre, J., Wong, R., Rao, J., & Gimzewski, J. K. (2008) · Nanotechnology · doi:10.1088/0957-4484/19/38/384003 · Cited by 418
In vivo brain viscoelastic properties measured by magnetic resonance elastography
Green, M. A., Bilston, L. E., & Sinkus, R. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1254 · Cited by 418
Accuracy of finite element model‐based multi‐organ deformable image registration
Brock, K. K., Sharpe, M. B., Dawson, L. A., Kim, S. M., & Jaffray, D. A. (2005) · Medical Physics · doi:10.1118/1.1915012 · Cited by 375
Sleeboom, J. J. F., van Tienderen, G. S., Schenke-Layland, K., van der Laan, L. J. W., Khalil, A. A., & Verstegen, M. M. A. (2024) · Science Translational Medicine · doi:10.1126/scitranslmed.adg3840 · Cited by 375
Sinkus, R., Siegmann, K., Xydeas, T., Tanter, M., Claussen, C., & Fink, M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21404 · Cited by 332
Non‐invasive measurement of brain viscoelasticity using magnetic resonance elastography
Sack, I., Beierbach, B., Hamhaber, U., Klatt, D., & Braun, J. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1189 · Cited by 316
MR Elastography of Liver Tumors: Preliminary Results
Venkatesh, S. K., Yin, M., Glockner, J. F., Takahashi, N., Araoz, P. A., Talwalkar, J. A., & Ehman, R. L. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.3123 · Cited by 312
Self-citationHuang, Y.-P., Zheng, Y.-P., Wang, S.-Z., Chen, Z.-P., Huang, Q.-H., & He, Y.-H. (2009) · Measurement Science and Technology · doi:10.1088/0957-0233/20/1/015805 · Cited by 312
MR-elastography reveals degradation of tissue integrity in multiple sclerosis
Wuerfel, J., Paul, F., Beierbach, B., Hamhaber, U., Klatt, D., Papazoglou, S., Zipp, F., Martus, P., Braun, J., & Sack, I. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.06.018 · Cited by 309
Current State of Breast Cancer Diagnosis, Treatment, and Theranostics
Bhushan, A., Gonsalves, A., & Menon, J. U. (2021) · Pharmaceutics · doi:10.3390/pharmaceutics13050723 · Cited by 298
Optical coherence elastography for tissue characterization: a review
Wang, S., & Larin, K. V. (2015) · Journal of Biophotonics · doi:10.1002/jbio.201400108 · Cited by 270
Mechanics of the normal woman's breast
Gefen, A., & Dilmoney, B. (2007) · Technology and Health Care · doi:10.3233/thc-2007-15404 · Cited by 257
Review of MR elastography applications and recent developments
Glaser, K. J., Manduca, A., & Ehman, R. L. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23597 · Cited by 245
“In an early study involving 6 healthy women and 6 patients with known breast cancer, MR elastograms depicted breast carcinomas as regions of high shear stiffness that were, on average, approximately 4 times stiffer than the surrounding fibroglandular tissue (118).”
BackgroundSelf-citationEvaluation of left ventricular diastolic function with cardiac MR imaging.
Caudron, J., Fares, J., Bauer, F., & Dacher, J.-N. (2011) · Radiographics · doi:10.1148/rg.311105049 · Cited by 129
General review of magnetic resonance elastography
Low, G. (2016) · World Journal of Radiology · doi:10.4329/wjr.v8.i1.59 · Cited by 123
Brain mechanical property measurement using MRE with intrinsic activation
Weaver, J. B., Pattison, A. J., McGarry, M. D., Perreard, I. M., Swienckowski, J. G., Eskey, C. J., Lollis, S. S., & Paulsen, K. D. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/22/7275 · Cited by 102
“One of the first clinical applications of elastography involved detecting breast lesions (Sinkus et al 2000, Garra et al 1997, McKnight et al 2002).”
Background
Metadata
- Authors
- McKnight, A. L., Kugel, J. L., Rossman, P. J., Manduca, A., Hartmann, L. C., & Ehman, R. L.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2002-06
- Volume
- 178
- Issue
- 6
- Pages
- 1411-1417
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W1975135842
- Cited by
- 381
- References
- 18
- FWCI
- 6.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.