Musculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The purpose of our study was to measure relaxation times in musculoskeletal tissues at 1.5 and 3.0 T to optimize musculoskeletal MRI methods at 3.0 T. MATERIALS AND METHODS: In the knees of five healthy volunteers, we measured the T1 and T2 relaxation times of cartilage, synovial fluid, muscle, marrow, and fat at 1.5 and 3.0 T. The T1 relaxation times were measured using a spiral Look-Locker sequence with eight samples along the T1 recovery curve. The T2 relaxation times were measured using a spiral T2 preparation sequence with six echoes. Accuracy and repeatability of the T1 and T2 measurement sequences were verified in phantoms. RESULTS: T1 relaxation times in cartilage, muscle, synovial fluid, marrow, and subcutaneous fat at 3.0 T were consistently higher than those measured at 1.5 T. Measured T2 relaxation times were reduced at 3.0 T compared with 1.5 T. Relaxation time measurements in vivo were verified using calculated and measured signal-to-noise results. Relaxation times were used to develop a high-resolution protocol for T2-weighted imaging of the knee at 3.0 T. CONCLUSION: MRI at 3.0 T can improve resolution and speed in musculoskeletal imaging; however, interactions between field strength and relaxation times need to be considered for optimal image contrast and signal-to-noise ratio. Scanning can be performed in shorter times at 3.0 T using single-average acquisitions. Efficient higher-resolution imaging at 3.0 T can be done by increasing the TR to account for increased T1 relaxation times and acquiring thinner slices than at 1.5 T.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bottomley, P. A., Foster, T. H., Argersinger, R. E., & Pfeifer, L. M. (1984) · Medical Physics · doi:10.1118/1.595535 · Cited by 1,192
Time Saving in Measurement of NMR and EPR Relaxation Times
Look, D. C., & Locker, D. R. (1970) · Review of Scientific Instruments · doi:10.1063/1.1684482 · Cited by 819
POTTER, H. G., LINKLATER, J. M., ALLEN, A. A., HANNAFIN, J. A., & HAAS, S. B. (1998) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199809000-00005 · Cited by 590
Coronary Angiography with Magnetization‐Prepared T2 Contrast
Brittain, J. H., Hu, B. S., Wright, G. A., Meyer, C. H., Macovski, A., & Nishimura, D. G. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330515 · Cited by 448
Self-citationAnisotropy of NMR properties of tissues
Henkelman, R. M., Stanisz, G. J., Kim, J. K., & Bronskill, M. J. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320508 · Cited by 424
Mosher, T. J., Dardzinski, B. J., & Smith, M. B. (2000) · Radiology · doi:10.1148/radiology.214.1.r00ja15259 · Cited by 390
Radiofrequency Energy-Induced Heating During MR Procedures: A Review
Shellock, F. G. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200007)12:1<30::aid-jmri4>3.0.co;2-s · Cited by 343
Spatial variation in cartilage T2 of the knee
Smith, H. E., Mosher, T. J., Dardzinski, B. J., Collins, B. G., Collins, C. M., Yang, Q. X., Schmithorst, V. J., & Smith, M. B. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1150 · Cited by 288
Collins, C. M., & Smith, M. B. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1091 · Cited by 260
Hennig, J., Weigel, M., & Scheffler, K. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10391 · Cited by 244
Cited by
T1, T2 relaxation and magnetization transfer in tissue at 3T
Stanisz, G. J., Odrobina, E. E., Pun, J., Escaravage, M., Graham, S. J., Bronskill, M. J., & Henkelman, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20605 · Cited by 1,266
“We would like to thank Dr. Garry Gold, Stanford University, for stimulating discussions during the preparation of this article, and Mr. Norm Konyer and Ms. Sharon Portnoy, Sunnybrook & Women’s CHSC, Toronto, for technical assistance.”
BackgroundResultInfluentialPeterfy, C. G., Schneider, E., & Nevitt, M. (2008) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2008.06.016 · Cited by 684
Eckstein, F., Cicuttini, F., Raynauld, J.-P., Waterton, J. C., & Peterfy, C. (2006) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2006.02.026 · Cited by 418
Fat-Suppression Techniques for 3-T MR Imaging of the Musculoskeletal System
Del Grande, F., Santini, F., Herzka, D. A., Aro, M. R., Dean, C. W., Gold, G. E., & Carrino, J. A. (2014) · RadioGraphics · doi:10.1148/rg.341135130 · Cited by 370
Self-citationQuantitative MRI of cartilage and bone: degenerative changes in osteoarthritis
Eckstein, F., Burstein, D., & Link, T. M. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1063 · Cited by 343
The effects of exercise on human articular cartilage
Eckstein, F., Hudelmaier, M., & Putz, R. (2006) · Journal of Anatomy · doi:10.1111/j.1469-7580.2006.00546.x · Cited by 300
What are normal relaxation times of tissues at 3 T?
Bojorquez, J. Z., Bricq, S., Acquitter, C., Brunotte, F., Walker, P. M., & Lalande, A. (2017) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2016.08.021 · Cited by 286
“[13] also used the LL sequence to measure the T1 relaxation times of muscle, cartilage, synovial fluid, bone marrow, and subcutaneous fat with flip angles of 10° in five volunteers.”
BackgroundMethodInfluentialBernstein, M. A., Huston, J., & Ward, H. A. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20698 · Cited by 255
A Review of MR Physics: 3T versus 1.5T
Soher, B. J., Dale, B. M., & Merkle, E. M. (2007) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2007.06.002 · Cited by 235
“However, more recently published studies by de Bazelaire and colleagues [3], Gold and colleagues [19], and Stanisz and colleagues [4] suggest a small, statisti-”
ResultTissue mimicking materials for imaging and therapy phantoms: a review
McGarry, C. K., Grattan, L. J., Ivory, A. M., Leek, F., Liney, G. P., Liu, Y., Miloro, P., Rai, R., Robinson, A., Shih, A. J., et al. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/abbd17 · Cited by 215
Relaxation times of breast tissue at 1.5T and 3T measured using IDEAL
Rakow‐Penner, R., Daniel, B., Yu, H., Sawyer‐Glover, A., & Glover, G. H. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20469 · Cited by 196
“The relaxation rates of other human tissues, such as musculoskeletal tissue (15), abdominal and pelvic tissue (9), and brain (16), have been measured at 3T.”
BackgroundOudeman, J., Nederveen, A. J., Strijkers, G. J., Maas, M., Luijten, P. R., & Froeling, M. (2016) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25016 · Cited by 192
In vivo diffusion tensor imaging of the human calf muscle
Sinha, S., Sinha, U., & Edgerton, V. R. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20593 · Cited by 167
“The signal-tonoise ratio (SNR) is a limiting factor in muscle imaging because muscle has low T2 compared to brain tissue (16).”
BackgroundVan Steenkiste, G., Poot, D. H. J., Jeurissen, B., den Dekker, A. J., Vanhevel, F., Parizel, P. M., & Sijbers, J. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26262 · Cited by 20
Metadata
- Authors
- Gold, G. E., Han, E., Stainsby, J., Wright, G., Brittain, J., & Beaulieu, C.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2004-08
- Volume
- 183
- Issue
- 2
- Pages
- 343-351
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2136247797
- Cited by
- 517
- References
- 20
- FWCI
- 22.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.