Clinical Myocardial Perfusion PET/CT
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
The field of nuclear cardiology is witnessing growing interest in the use of cardiac PET for the evaluation of patients with coronary artery disease (CAD). The available evidence suggests that myocardial perfusion PET provides an accurate means for diagnosing obstructive CAD, which appears superior to SPECT especially in the obese and in those undergoing pharmacologic stress. The ability to record changes in left ventricular function from rest to peak stress and to quantify myocardial perfusion (in mL/min/g of tissue) provides an added advantage over SPECT for evaluating multivessel CAD. There is growing and consistent evidence that gated myocardial perfusion PET also provides clinically useful risk stratification. Although the introduction of hybrid PET/CT technology offers the exciting possibility of assessing the extent of anatomic CAD (CT coronary angiography) and its functional consequences (ischemic burden) in the same setting, there are technical challenges in the implementation of CT-based transmission imaging for attenuation correction. Nonetheless, this integrated platform for assessing anatomy and biology offers a great potential for translating advances in molecularly targeted imaging into humans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantification of Obstructive and Nonobstructive Coronary Lesions by 64-Slice Computed Tomography
Leber, A. W., Knez, A., von Ziegler, F., Becker, A., Nikolaou, K., Paul, S., Wintersperger, B., Reiser, M., Becker, C. R., Steinbeck, G., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.071 · Cited by 1,109
Effects of coronary stenoses on coronary flow reserve and resistance
Gould, K. L., & Lipscomb, K. (1974) · The American Journal of Cardiology · doi:10.1016/0002-9149(74)90092-7 · Cited by 882
Relation between Myocardial Blood Flow and the Severity of Coronary-Artery Stenosis
Uren, N. G., Melin, J. A., De Bruyne, B., Wijns, W., Baudhuin, T., & Camici, P. G. (1994) · New England Journal of Medicine · doi:10.1056/nejm199406233302503 · Cited by 881
Hutchins, G. D., Schwaiger, M., Rosenspire, K. C., Krivokapich, J., Schelbert, H., & Kuhl, D. E. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90237-j · Cited by 552
Albro, P. C., Gould, K. L., Westcott, R. J., Hamilton, G. W., Ritchie, J. L., & Williams, D. L. (1978) · The American Journal of Cardiology · doi:10.1016/0002-9149(78)90094-2 · Cited by 536
Bateman, T. M., Heller, G. V., McGhie, A. I., Friedman, J. D., Case, J. A., Bryngelson, J. R., Hertenstein, G. K., Moutray, K. L., Reid, K., & Cullom, S. J. (2006) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2005.12.004 · Cited by 527
Schuijf, J. D., Wijns, W., Jukema, J. W., Atsma, D. E., de Roos, A., Lamb, H. J., Stokkel, M. P. M., Dibbets-Schneider, P., Decramer, I., De Bondt, P., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.05.080 · Cited by 479
N-13 ammonia as an indicator of myocardial blood flow.
Schelbert, H. R., Phelps, M. E., Huang, S. C., MacDonald, N. S., Hansen, H. W., Selin, C. E., & Kuhl, D. E. (1981) · Circulation · doi:10.1161/01.cir.63.6.1259 · Cited by 452
Reduced Coronary Vasodilator Function in Infarcted and Normal Myocardium after Myocardial Infarction
Uren, N. G., Crake, T., Lefroy, D. C., de Silva, R., Davies, G. J., & Maseri, A. (1994) · New England Journal of Medicine · doi:10.1056/nejm199407283310402 · Cited by 391
Di Carli, M., Czernin, J., Hoh, C. K., Gerbaudo, V. H., Brunken, R. C., Huang, S.-C., Phelps, M. E., & Schelbert, H. R. (1995) · Circulation · doi:10.1161/01.cir.91.7.1944 · Cited by 372
Self-citation
Cited by
Fletcher, G. F., Ades, P. A., Kligfield, P., Arena, R., Balady, G. J., Bittner, V. A., Coke, L. A., Fleg, J. L., Forman, D. E., Gerber, T. C., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31829b5b44 · Cited by 2,235
Synthesis of 11C, 18F, 15O, and 13N Radiolabels for Positron Emission Tomography
Miller, P. W., Long, N. J., Vilar, R., & Gee, A. D. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200800222 · Cited by 894
PET versus SPECT: strengths, limitations and challenges
Rahmim, A., & Zaidi, H. (2008) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e3282f3a515 · Cited by 834
18F-Labeling of Arenes and Heteroarenes for Applications in Positron Emission Tomography
Preshlock, S., Tredwell, M., & Gouverneur, V. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00493 · Cited by 679
Dilsizian, V., Bacharach, S. L., Beanlands, R. S., Bergmann, S. R., Delbeke, D., Dorbala, S., Gropler, R. J., Knuuti, J., Schelbert, H. R., & Travin, M. I. (2016) · Journal of Nuclear Cardiology · doi:10.1007/s12350-016-0522-3 · Cited by 612
Self-citationKajander, S., Joutsiniemi, E., Saraste, M., Pietilä, M., Ukkonen, H., Saraste, A., Sipilä, H. T., Teräs, M., Mäki, M., Airaksinen, J., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.915009 · Cited by 402
Rominger, A., Saam, T., Wolpers, S., Cyran, C. C., Schmidt, M., Foerster, S., Nikolaou, K., Reiser, M. F., Bartenstein, P., & Hacker, M. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.065151 · Cited by 362
Bocher, M., Blevis, I. M., Tsukerman, L., Shrem, Y., Kovalski, G., & Volokh, L. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1488-z · Cited by 303
Dorbala, S., Hachamovitch, R., Curillova, Z., Thomas, D., Vangala, D., Kwong, R. Y., & Di Carli, M. F. (2009) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2009.04.009 · Cited by 271
Self-citationGupta, A., Taqueti, V. R., van de Hoef, T. P., Bajaj, N. S., Bravo, P. E., Murthy, V. L., Osborne, M. T., Seidelmann, S. B., Vita, T., Bibbo, C. F., et al. (2017) · Circulation · doi:10.1161/circulationaha.117.029992 · Cited by 267
Self-citationEl Fakhri, G., Kardan, A., Sitek, A., Dorbala, S., Abi-Hatem, N., Lahoud, Y., Fischman, A., Coughlan, M., Yasuda, T., & Di Carli, M. F. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.104.007831 · Cited by 266
Self-citationNoninvasive Assessment of Myocardial Perfusion
Salerno, M., & Beller, G. A. (2009) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.109.854893 · Cited by 211
EANM procedural guidelines for PET/CT quantitative myocardial perfusion imaging
Cardiovascular Committee of the European Association of Nuclear Medicine (EANM), Sciagrà, R., Lubberink, M., Hyafil, F., Saraste, A., Slart, R. H. J. A., Agostini, D., Nappi, C., Georgoulias, P., Bucerius, J., et al. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-05046-9 · Cited by 164
“Sensitivity and specificity for detecting an angiographically significant coronary stenosis of > 50% are 87% and 73% for SPECT MPI compared with 91% and 89% for (82)Rb MPI, respectively [129, 130].”
MethodDesign of superparamagnetic nanoparticles for magnetic particle imaging (MPI)
Du, Y., Lai, P., Leung, C., & Pong, P. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms140918682 · Cited by 81
“For example, positron emission tomography (PET) and single photon emission computed tomography (SPECT), for assessment of tissue perfusion, introduce radioactive tracers [97,98].”
BackgroundEnhancing Cardiac PET by Motion Correction Techniques
Rubeaux, M., Doris, M. K., Alessio, A., & Slomka, P. J. (2017) · Current Cardiology Reports · doi:10.1007/s11886-017-0825-2 · Cited by 48
Gating Approaches in Cardiac PET Imaging
Lassen, M. L., Kwiecinski, J., & Slomka, P. J. (2019) · PET Clinics · doi:10.1016/j.cpet.2018.12.008 · Cited by 38
“Cardiac gating can serve two functions: (1) it can be used for motion compensation of the myocardium 35 and (2) for functional assessment of the myocardium.”
Method
Metadata
- Authors
- Di Carli, M. F., Dorbala, S., Meserve, J., El Fakhri, G., Sitek, A., & Moore, S. C.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2007-05-01
- Volume
- 48
- Issue
- 5
- Pages
- 783-793
- ISSN
- 0161-5505 (ISSN-L)
- OpenAlex
- W2125893301
- Cited by
- 290
- References
- 35
- FWCI
- 20.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.