The DOI matches its Crossref record; 80 of the 80 references it cites were found in a registry or an index.
Dual-Modality Imaging: Combining Anatomy and Function
Open accessAbstract
The extensive development of image fusion techniques over the past 20 y has shown that the fusion of images from complementary modalities offers a more complete and accurate assessment of disease than do images from a single modality. Although software techniques have been successful in fusing images of the brain from different modalities, they have achieved rather limited success for other parts of the body. The recent introduction of technology that can acquire both anatomic and functional images in a single scan has addressed many of the limitations of software fusion. The combination of CT and PET was introduced commercially in 2001, followed by CT and SPECT in 2004. Clinical adoption of PET/CT has been surprisingly rapid, and despite continuing debate, the new technology has advanced the use of clinical molecular imaging, particularly for oncology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547 · cited 1×
“Metrics include intensity ratios (6) and mutual information (7).”
BackgroundAccelerated image reconstruction using ordered subsets of projection data
Hudson, H. M., & Larkin, R. S. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363108 · Cited by 3,711
A combined PET/CT scanner for clinical oncology.
Beyer, T., Townsend, D. W., Brun, T., Kinahan, P. E., Charron, M., Roddy, R., Jerin, J., Young, J., Byars, L. G., & Nutt, R. (2000) · PubMed · Cited by 1,659
Self-citationMRI-PET Registration with Automated Algorithm
Woods, R. P., Mazziotta, J. C., & R. Cherry, A. S. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199307000-00004 · Cited by 1,617
Kalender, W. A., Seissler, W., Klotz, E., & Vock, P. (1990) · Radiology · doi:10.1148/radiology.176.1.2353088 · Cited by 1,036
Attenuation correction for a combined 3D PET/CT scanner
Kinahan, P. E., Townsend, D. W., Beyer, T., & Sashin, D. (1998) · Medical Physics · doi:10.1118/1.598392 · Cited by 946 · cited 3×
“, the CT images from the PET/CT scanner were used to generate PET attenuation correction factors using an energy-scaling algorithm (23).”
BackgroundMethodSelf-citationComparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884
Cerium-doped lutetium oxyorthosilicate: a fast, efficient new scintillator
Melcher, C. L., & Schweitzer, J. S. (1992) · IEEE Transactions on Nuclear Science · doi:10.1109/23.159655 · Cited by 846
Analytic 3D image reconstruction using all detected events
Kinahan, P. E., & Rogers, J. G. (1989) · IEEE Transactions on Nuclear Science · doi:10.1109/23.34585 · Cited by 767
Exact and approximate rebinning algorithms for 3-D PET data
Defrise, M., Kinahan, P. E., Townsend, D. W., Michel, C., Sibomana, M., & Newport, D. F. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563660 · Cited by 758
Self-citationSurti, S., Kuhn, A., Werner, M. E., Perkins, A. E., Kolthammer, J. A., & Karp, J. S. (2007) · PubMed · Cited by 639
4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT
Pan, T., Lee, T.-Y., Rietzel, E., & Chen, G. T. Y. (2004) · Medical Physics · doi:10.1118/1.1639993 · Cited by 624
(2014) · Nuclear Medicine · doi:10.1016/b978-0-323-08299-0.00003-1 · Cited by 578
Fully 3-D PET reconstruction with system matrix derived from point source measurements
Panin, V. Y., Kehren, F., Michel, C., & Casey, M. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.876171 · Cited by 536
X-ray-based attenuation correction for positron emission tomography/computed tomography scanners
Kinahan, P. E., Hasegawa, B. H., & Beyer, T. (2003) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2003.127307 · Cited by 515
Radiation exposure of patients undergoing whole-body dual-modality 18F-FDG PET/CT examinations.
Brix, G., Lechel, U., Glatting, G., Ziegler, S. I., Münzing, W., Müller, S. P., & Beyer, T. (2005) · PubMed · Cited by 458
Burger, C., Goerres, G., Schoenes, S., Buck, A., Lonn, A., & von Schulthess, G. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-0796-3 · Cited by 428
Managing patient dose in computed tomography
(2000) · Annals of the ICRP · doi:10.1016/s0146-6453(01)00049-5 · Cited by 375
Improvements in cancer staging with PET/CT: literature-based evidence as of September 2006.
Czernin, J. G., Allen-Auerbach, M., & Schelbert, H. R. (2007) · PubMed · Cited by 355
Use of PET for monitoring cancer therapy and for predicting outcome.
Weber, W. (2005) · PubMed · Cited by 341
Caldwell, C. B., Mah, K., Ung, Y. C., Danjoux, C. E., Balogh, J. M., Ganguli, S. N., & Ehrlich, L. E. (2001) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(01)01722-9 · Cited by 320
Kachelrieß, M., Watzke, O., & Kalender, W. A. (2001) · Medical Physics · doi:10.1118/1.1358303 · Cited by 311
Beyer, T., Antoch, G., Blodgett, T., Freudenberg, L. F., Akhurst, T., & Mueller, S. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-1097-6 · Cited by 298
Gould, K. L., Pan, T., Loghin, C., Johnson, N. P., Guha, A., & Sdringola, S. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.039792 · Cited by 292
Time-of-flight positron emission tomography: status relative to conventional PET.
Budinger, T. F. (1983) · PubMed · Cited by 283
Method for transforming CT images for attenuation correction in PET/CT imaging
Carney, J. P. J., Townsend, D. W., Rappoport, V., & Bendriem, B. (2006) · Medical Physics · doi:10.1118/1.2174132 · Cited by 271
Self-citationPET/CT scanners: A hardware approach to image fusion
Townsend, D. W., Beyer, T., & Blodgett, T. M. (2003) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2003.127314 · Cited by 262
Self-citationClinically significant inaccurate localization of lesions with PET/CT: frequency in 300 patients.
Osman, M., Cohade, C., Nakamoto, Y., Marshall, L. T., Leal, J. P., & Wahl, R. L. (2003) · PubMed · Cited by 252
Attenuation correction of PET images with respiration-averaged CT images in PET/CT.
Pan, T., Mawlawi, O. R., Nehmeh, S. A., Erdi, Y. E., Luo, D., Liu, H. H., Castillo, R., Mohan, R., Liao, Z. X., & Macapinlac, H. A. (2005) · PubMed · Cited by 251
Kalender, W. A., Wolf, H., Suess, C., Gies, M., Greess, H., & Bautz, W. A. (1999) · European Radiology · doi:10.1007/s003300050674 · Cited by 245
Osman, M. M., Cohade, C., Nakamoto, Y., & Wahl, R. L. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-1024-x · Cited by 236
To enhance or not to enhance? 18F-FDG and CT contrast agents in dual-modality 18F-FDG PET/CT.
Antoch, G., Freudenberg, L. S., Beyer, T., Bockisch, A., & Debatin, J. F. (2004) · PubMed · Cited by 236
Combined PET/CT Imaging in Oncology Impact on Patient Management
Kluetz, P. (2000) · Clinical Positron Imaging · doi:10.1016/s1095-0397(01)00055-3 · Cited by 226
The Theory and Practice of 3D PET
(1998) · Springer eBooks · doi:10.1007/978-94-017-3475-2 · Cited by 223
Wahl, R. L., Quint, L. E., Cieslak, R., Aisen, A. M., Koeppe, R. A., & Meyer, C. R. (1993) · PubMed · Cited by 219
Bocher, M., Balan, A., Krausz, Y., Shrem, Y., Lonn, A., Wilk, M., & Chisin, R. (2000) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050555 · Cited by 213
Dawood, M., Büther, F., Lang, N., Schober, O., & Schäfers, K. P. (2007) · Medical Physics · doi:10.1118/1.2748104 · Cited by 211
Focal tracer uptake: a potential artifact in contrast-enhanced dual-modality PET/CT scans.
Antoch, G., Freudenberg, L. S., Egelhof, T., Stattaus, J., Jentzen, W., Debatin, J. F., & Bockisch, A. (2002) · PubMed · Cited by 201
Positon emission tomography: basic science and clinical practice
Valk, P., Bayley, D. L., Dw, T., & Maisey, M. (2008) · Cited by 195
Artifacts at PET and PET/CT Caused by Metallic Hip Prosthetic Material
Goerres, G. W., Ziegler, S. I., Burger, C., Berthold, T., von Schulthess, G. K., & Buck, A. (2003) · Radiology · doi:10.1148/radiol.2262012141 · Cited by 191
Description of a prototype emission-transmission computed tomography imaging system.
Lang, T., Hasegawa, B. H., Liew, S. C., Brown, J. K., Blankespoor, S. C., Reilly, S. M., Gingold, E. L., & Cann, C. E. (1992) · PubMed · Cited by 175
Blankespoor, S. C., Xu, X., Kaiki, K., Brown, J. K., Tang, H. R., Cann, C. E., & Hasegawa, B. H. (1996) · IEEE Transactions on Nuclear Science · doi:10.1109/23.531891 · Cited by 170
Cohade, C., & Wahl, R. L. (2003) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2003.127312 · Cited by 168
Fast reconstruction of 3D PET data with accurate statistical modeling
Comtat, C., Kinahan, P. E., Defrise, M., Michel, C., & Townsend, D. W. (1998) · IEEE Transactions on Nuclear Science · doi:10.1109/23.681983 · Cited by 165
Self-citationImpact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner
Kamel, E. M., Burger, C., Buck, A., von Schulthess, G. K., & Goerres, G. W. (2003) · European Radiology · doi:10.1007/s00330-002-1564-2 · Cited by 163
Nakamoto, Y., Osman, M., Cohade, C., Marshall, L. T., Links, J. M., Kohlmyer, S. G., & Wahl, R. L. (2002) · PubMed · Cited by 161
Deep-inspiration breath-hold PET/CT of the thorax.
Nehmeh, S. A., Erdi, Y. E., Meirelles, G. D. S. P., Squire, O. D., Larson, S. M., Humm, J. L., & Schöder, H. M. (2007) · PubMed · Cited by 152
Initial experience with oral contrast in PET/CT: phantom and clinical studies.
Cohade, C., Osman, M., Nakamoto, Y., Marshall, L. T., Links, J. M., Fishman, E. K., & Wahl, R. L. (2003) · PubMed · Cited by 152
PET/CT with intravenous contrast can be used for PET attenuation correction in cancer patients
Berthelsen, A. K., Holm, S., Loft, A., Klausen, T. L., Andersen, F., & Højgaard, L. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-1784-1 · Cited by 151
Positron emission tomography/computed tomography?imaging protocols, artifacts, and pitfalls
Bockisch, A., Beyer, T., Antoch, G., Freudenberg, L., Kühl, H., Debatin, J. F., & MULLER, S. (2004) · Molecular Imaging and Biology · doi:10.1016/j.mibio.2004.04.006 · Cited by 145
Comparison of 3-D reconstruction with 3D-OSEM and with FORE+OSEM for PET
Liu, X. E., Comtat, C., Michel, C. J., Kinahan, P. E., Defrise, M., & Townsend, D. W. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.938248 · Cited by 143
Self-citationQuantifying the Effect of IV Contrast Media on Integrated PET/CT: Clinical Evaluation
Mawlawi, O. R., Erasmus, J. J., Munden, R. F., Pan, T., Knight, A. E., Macapinlac, H. A., Podoloff, D. A., & Chasen, M. H. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.04.1740 · Cited by 143
Watson, C. C., Casey, M., Bendriem, B., Carney, J., Townsend, D. W., Eberl, S., Meikle, S. R., & DiFilippo, F. P. (2005) · PubMed · Cited by 140
Self-citationSoftware for image registration: Algorithms, accuracy, efficacy
Hutton, B. F., & Braun, M. (2003) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2003.127309 · Cited by 139
OSEM-3D Reconstruction Strategies for the ECAT HRRT
Comtat, Bataille, F., Michel, C. J., Jones, J. P., Sibomana, M., Janeiro, L., & Trébossen, R. (2005) · IEEE Symposium Conference Record Nuclear Science 2004. · doi:10.1109/nssmic.2004.1466639 · Cited by 133
Dual cardiac–respiratory gated PET: implementation and results from a feasibility study
Martínez-Möller, A., Zikic, D., Botnar, R. M., Bundschuh, R. A., Howe, W., Ziegler, S. I., Navab, N., Schwaiger, M., & Nekolla, S. G. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-007-0374-9 · Cited by 131
Brambilla, M., Secco, C., Dominietto, M. D., Matheoud, R., Sacchetti, G., & Inglese, E. (2005) · PubMed · Cited by 131
Software approach to merging molecular with anatomic information.
Slomka, P. J. (2004) · PubMed · Cited by 118
Kim, J., Czernin, J. G., Allen-Auerbach, M., Halpern, B. S., Fueger, B. J., Hecht, J. R., Ratib, O. M., Phelps, M. E., & Weber, W. (2005) · PubMed · Cited by 113
Cine CT for Attenuation Correction in Cardiac PET/CT
Alessio, A. M., Kohlmyer, S. G., Branch, K. R., Chen, G., Caldwell, J. R., & Kinahan, P. E. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.035717 · Cited by 109
Deloar, H. M., Fujiwara, T., Shidahara, M., Nakamura, T., Watabe, H., Narita, Y., Itoh, M., Miyake, M., & Watanuki, S. (1998) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050257 · Cited by 109
Daube-Witherspoon, M. E., Matej, S., Karp, J. S., & Lewitt, R. M. (2001) · IEEE Transactions on Nuclear Science · doi:10.1109/23.910827 · Cited by 108
Coleman, R. E., Delbeke, D., Guiberteau, M. J., Conti, P. S., Royal, H. D., Weinreb, J. C., Siegel, B. A., Federle, M. P., Townsend, D. W., & Berland, L. L. (2005) · PubMed · Cited by 108
Self-citationIterative image reconstruction using geometrically ordered subsets with list-mode data
Popescu, L. M., Matej, S., & Lewitt, R. M. (2005) · IEEE Symposium Conference Record Nuclear Science 2004. · doi:10.1109/nssmic.2004.1466649 · Cited by 108
KEMP, B. J., Kim, C., Williams, J. J., Ganin, A., & Lowe, V. J. (2006) · PubMed · Cited by 107
Meirelles, G. D. S. P., Erdi, Y. E., Nehmeh, S. A., Squire, O. D., Larson, S. M., Humm, J. L., & Schöder, H. M. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.038034 · Cited by 103
Bailey, D. L., Young, H. E., Bloomfield, P. M., Meikle, S. R., Glass, D. M., Myers, M. J., Spinks, T. J., Watson, C. C., Luk, P., Peters, A. M., et al. (1997) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/bf01728302 · Cited by 96
Automated 3-dimensional registration of stand-alone (18)F-FDG whole-body PET with CT.
Slomka, P. J., Dey, D., Przetak, C., Aladl, U. E., & Baum, R. P. (2003) · PubMed · Cited by 93
Fisher, D. R., Shen, S., & Meredith, R. F. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057331 · Cited by 91
Israel, O., & Kuten, A. (2007) · PubMed · Cited by 85
Object-specific attenuation correction of SPECT with correlated dual-energy X-ray CT
Hasegawa, B. H., Lang, T., Brown, J. K., Gingold, E. L., Reilly, S. M., Blankespoor, S. C., Liew, S. C., Tsui, B. M. W., & Ramanathan, C. (1993) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1993.8526573 · Cited by 83
Allen-Auerbach, M., Yeom, K. W., Park, J. B., Phelps, M. E., & Czernin, J. (2006) · PubMed · Cited by 72
Nagel, C. C. A., Bosmans, G., Dekker, A. L. A. J., Öllers, M., Ruysscher, D. D., Lambin, P., Minken, A., Lang, N., & Schäfers, K. P. (2006) · Medical Physics · doi:10.1118/1.2198170 · Cited by 67
Papathanassiou, D., Becker, S., Amir, R., Menéroux, B., & Liehn, J. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-1868-y · Cited by 62
Brechtel, K., Klein, M., Vogel, M. N., Mueller, M., Aschoff, P., Beyer, T., Eschmann, S. M., Bares, R., Claussen, C. D., & Pfannenberg, A. C. (2006) · PubMed · Cited by 60
Beyer, T., Rosenbaum, S. J., Veit, P., Stattaus, J., Müller, S. P., DiFilippo, F. P., Schöder, H. M., Mawlawi, O. R., Roberts, F., Bockisch, A., et al. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-1879-8 · Cited by 57
Sorenson, J. A., & Phelps, M. E. (1980) · CERN Document Server (European Organization for Nuclear Research) · Cited by 49
Lodge, M. A., Badawi, R. D., Gilbert, R., Dibos, P. E., & Line, B. R. (2006) · PubMed · Cited by 36
Townsend, D. W., Isoardi, R., & Bendriem, B. (1998) · Springer eBooks · doi:10.1007/978-94-017-3475-2_4 · Cited by 35
Self-citationSuppression of metal streak artifacts in CT using a MAP reconstruction procedure
Lemmens, C., Faul, D. D., Hamill, J. J., et al. (2006) · 2006 IEEE Nuclear Science Symposium Conference Record · doi:10.1109/nssmic.2006.353739 · Cited by 18
Cited by
Chemical Design and Synthesis of Functionalized Probes for Imaging and Treating Tumor Hypoxia
Liu, J.-N., Bu, W., & Shi, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00525 · Cited by 838
Yang, X., Hong, H., Grailer, J. J., Rowland, I. J., Javadi, A., Hurley, S. A., Xiao, Y., Yang, Y., Zhang, Y., Nickles, R. J., et al. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.02.006 · Cited by 436
PET/MRI: Paving the Way for the Next Generation of Clinical Multimodality Imaging Applications
Pichler, B. J., Kolb, A., Nägele, T., & Schlemmer, H.-P. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.061853 · Cited by 418
“Clinical studies have demonstrated the advantages of PET/CT over separately performed PET and CT, and the technology has evolved rapidly into a powerful diagnostic tool, particularly in the field of oncology (14).”
BackgroundStimuli-responsive polymers and nanomaterials for gene delivery and imaging applications
Shim, M. S., & Kwon, Y. J. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.01.018 · Cited by 384
Resolution modeling in PET imaging: Theory, practice, benefits, and pitfalls
Rahmim, A., Qi, J., & Sossi, V. (2013) · Medical Physics · doi:10.1118/1.4800806 · Cited by 357
Metadata
- Authors
- Townsend, D. W.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2008-05-15
- Volume
- 49
- Issue
- 6
- Pages
- 938-955
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2051361140
- Cited by
- 282
- References
- 80
- FWCI
- 19.11
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.