The DOI matches its Crossref record; 69 of the 69 references it cites were found in a registry or an index.
Diffusion Tensor MR Imaging and Fiber Tractography: Technical Considerations
Open accessAbstract
This second article of the 2-part review builds on the theoretic background provided by the first article to cover the major technical factors that affect image quality in diffusion imaging, including the acquisition sequence, magnet field strength, gradient amplitude, and slew rate as well as multichannel radio-frequency coils and parallel imaging. The sources of many common diffusion image artifacts are also explored in detail. The emphasis is on optimizing these technical factors for state-of-the-art diffusion-weighted imaging and diffusion tensor imaging (DTI) based on the best available evidence in the literature. An overview of current methods for quantitative analysis of DTI data and fiber tractography in clinical research is also provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tract-based spatial statistics: Voxelwise analysis of multi-subject diffusion data
Smith, S. M., Jenkinson, M., Johansen-Berg, H., Rueckert, D., Nichols, T. E., Mackay, C. E., Watkins, K. E., Ciccarelli, O., Cader, M. Z., Matthews, P. M., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.02.024 · Cited by 6,478
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Probabilistic diffusion tractography with multiple fibre orientations: What can we gain?
Behrens, T. E. J., Berg, H. J., Jbabdi, S., Rushworth, M. F. S., & Woolrich, M. W. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.09.018 · Cited by 3,471
Toward a quantitative assessment of diffusion anisotropy
Pierpaoli, C., & Basser, P. J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360612 · Cited by 2,405
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Fiber tracking: principles and strategies – a technical review
Mori, S., & van Zijl, P. C. M. (2002) · NMR in Biomedicine · doi:10.1002/nbm.781 · Cited by 2,024
Tracking neuronal fiber pathways in the living human brain
Conturo, T. E., Lori, N. F., Cull, T. S., Akbudak, E., Snyder, A. Z., Shimony, J. S., McKinstry, R. C., Burton, H., & Raichle, M. E. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.18.10422 · Cited by 1,774
Reproducibility of quantitative tractography methods applied to cerebral white matter
Wakana, S., Caprihan, A., Panzenboeck, M. M., Fallon, J. H., Perry, M., Gollub, R. L., Hua, K., Zhang, J., Jiang, H., Dubey, P., et al. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.02.049 · Cited by 1,686
Virtual in vivo interactive dissection of white matter fasciculi in the human brain
Catani, M., Howard, R. J., Pajevic, S., & Jones, D. K. (2002) · NeuroImage · doi:10.1006/nimg.2002.1136 · Cited by 1,637
Tournier, J.-D., Calamante, F., Gadian, D. G., & Connelly, A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.037 · Cited by 1,635
Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
Jones, D. K., Horsfield, M. A., & Simmons, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<515::aid-mrm14>3.0.co;2-q · Cited by 1,403
Mapping complex tissue architecture with diffusion spectrum magnetic resonance imaging
Wedeen, V. J., Hagmann, P., Tseng, W. I., Reese, T. G., & Weisskoff, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20642 · Cited by 1,339
Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo
Reese, T. G., Heid, O., Weisskoff, R. M., & Wedeen, V. J. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10308 · Cited by 1,227
Dietrich, O., Raya, J. G., Reeder, S. B., Reiser, M. F., & Schoenberg, S. O. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20969 · Cited by 992
Mapping Human Whole-Brain Structural Networks with Diffusion MRI
Hagmann, P., Kurant, M., Gigandet, X., Thiran, P., Wedeen, V. J., Meuli, R., & Thiran, J.-P. (2007) · PLoS ONE · doi:10.1371/journal.pone.0000597 · Cited by 788
Artifacts and pitfalls in diffusion MRI
Le Bihan, D., Poupon, C., Amadon, A., & Lethimonnier, F. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20683 · Cited by 778
Jones, D. K. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20033 · Cited by 773
Diffusion MRI of complex neural architecture.
Tuch, D. S., Reese, T. G., Wiegell, M. R., & Wedeen, V. J. (2003) · Neuron · doi:10.1016/s0896-6273(03)00758-x · Cited by 698
Neil, J. J., Shiran, S. I., McKinstry, R. C., Schefft, G. L., Snyder, A. Z., Almli, C. R., Akbudak, E., Aronovitz, J. A., Miller, J. P., Lee, B. C., et al. (1998) · Radiology · doi:10.1148/radiology.209.1.9769812 · Cited by 646
“Squashing peanuts and smashing pumpkins”: How noise distorts diffusion‐weighted MR data
Jones, D. K., & Basser, P. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20283 · Cited by 587
The effect of filter size on VBM analyses of DT-MRI data
JONES, D., SYMMS, M., CERCIGNANI, M., & HOWARD, R. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.013 · Cited by 567
Diffusion Tensor MR Imaging and Fiber Tractography: Theoretic Underpinnings
Mukherjee, P., Berman, J. I., Chung, S. W., Hess, C. P., & Henry, R. G. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1051 · Cited by 521
Self-citationMukherjee, P., Miller, J. H., Shimony, J. S., Philip, J. V., Nehra, D., Snyder, A. Z., Conturo, T. E., Neil, J. J., & McKinstry, R. C. (2002) · PubMed Central · Cited by 445
Self-citationMukherjee, P., Miller, J. H., Shimony, J. S., Conturo, T. E., Lee, B. C. P., Almli, C. R., & McKinstry, R. C. (2001) · Radiology · doi:10.1148/radiol.2212001702 · Cited by 431
Self-citationMultishot diffusion‐weighted FSE using PROPELLER MRI
Pipe, J. G., Farthing, V. G., & Forbes, K. P. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10014 · Cited by 428
Q‐ball reconstruction of multimodal fiber orientations using the spherical harmonic basis
Hess, C. P., Mukherjee, P., Han, E. T., Xu, D., & Vigneron, D. B. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20931 · Cited by 366
Self-citationFarrell, J. A. D., Landman, B. A., Jones, C. K., Smith, S. A., Prince, J. L., van Zijl, P. C. M., & Mori, S. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21053 · Cited by 357
Bammer, R., Keeling, S. L., Augustin, M., Pruessmann, K. P., Wolf, R., Stollberger, R., Hartung, H., & Fazekas, F. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1226 · Cited by 311
Comparison of gradient encoding schemes for diffusion‐tensor MRI
Hasan, K. M., Parker, D. L., & Alexander, A. L. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1107 · Cited by 309
Conturo, T. E., McKinstry, R. C., Akbudak, E., & Robinson, B. H. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350319 · Cited by 300
Skare, S., Hedehus, M., Moseley, M. E., & Li, T.-Q. (2000) · Journal of Magnetic Resonance · doi:10.1006/jmre.2000.2209 · Cited by 297
Landman, B. A., Farrell, J. A. D., Jones, C. K., Smith, S. A., Prince, J. L., & Mori, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.02.056 · Cited by 285
Theoretical analysis of the effects of noise on diffusion tensor imaging
Anderson, A. W. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1315 · Cited by 280
Diffusion tensor imaging using single‐shot SENSE‐EPI
Bammer, R., Auer, M., Keeling, S. L., Augustin, M., Stables, L. A., Prokesch, R. W., Stollberger, R., Moseley, M. E., & Fazekas, F. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10184 · Cited by 279
Ultimate intrinsic signal‐to‐noise ratio for parallel MRI: Electromagnetic field considerations
Ohliger, M. A., Grant, A. K., & Sodickson, D. K. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10597 · Cited by 238
Validation of in vitro probabilistic tractography
Dyrby, T. B., Søgaard, L. V., Parker, G. J., Alexander, D. C., Lind, N. M., Baaré, W. F. C., Hay-Schmidt, A., Eriksen, N., Pakkenberg, B., Paulson, O. B., et al. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.06.022 · Cited by 236
Optimal imaging parameters for fiber-orientation estimation in diffusion MRI
Alexander, D. C., & Barker, G. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.04.008 · Cited by 232
From diffusion tractography to quantitative white matter tract measures: a reproducibility study
Ciccarelli, O., Parker, G. J. M., Toosy, A. T., Wheeler-Kingshott, C. A. M., Barker, G. J., Boulby, P. A., Miller, D. H., & Thompson, A. J. (2003) · NeuroImage · doi:10.1016/s1053-8119(02)00042-3 · Cited by 228
Diffusion Tensor Imaging and Tractography of Human Brain Development
Mukherjee, P., & McKinstry, R. C. (2006) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2005.11.004 · Cited by 221
Self-citationJaermann, T., Crelier, G., Pruessmann, K. P., Golay, X., Netsch, T., van Muiswinkel, A. M. C., Mori, S., van Zijl, P. C. M., Valavanis, A., Kollias, S., et al. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10707 · Cited by 209
A Comparative Study of Acquisition Schemes for Diffusion Tensor Imaging Using MRI
Papadakis, N. G., Xing, D., Huang, C. L.-H., Hall, L. D., & Carpenter, T. A. (1999) · Journal of Magnetic Resonance · doi:10.1006/jmre.1998.1673 · Cited by 203
Wiesinger, F., Van de Moortele, P., Adriany, G., De Zanche, N., Ugurbil, K., & Pruessmann, K. P. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20281 · Cited by 198
Alexander, A. L., Tsuruda, J. S., & Parker, D. L. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380623 · Cited by 192
Bastin, M. E., Armitage, P. A., & Marshall, I. (1998) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(98)00098-8 · Cited by 188
Ni, H., Kavcic, V., Zhu, T., EKHOLM, S. E., & Zhong, J. (2006) · PubMed · Cited by 177
An error analysis of white matter tractography methods: synthetic diffusion tensor field simulations
Lazar, M., & Alexander, A. L. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00277-5 · Cited by 169
Probabilistic streamline q-ball tractography using the residual bootstrap
Berman, J. I., Chung, S., Mukherjee, P., Hess, C. P., Han, E. T., & Henry, R. G. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.08.021 · Cited by 168
Self-citationReplicability of diffusion tensor imaging measurements of fractional anisotropy and trace in brain
Adolf Pfefferbaum, A., Elfar Adalsteinsson, A., & Sullivan, E. V. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10377 · Cited by 160
On the effects of gating in diffusion imaging of the brain using single shot EPI
Skare, S. T., & Andersson, J. (2001) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(01)00415-5 · Cited by 157
Skare, S. T., Newbould, R. D., Clayton, D., Albers, G. W., Nagle, S. K., & Bammer, R. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21176 · Cited by 151
Minimal gradient encoding for robust estimation of diffusion anisotropy☆
Papadakis, N. G., Murrills, C. D., Hall, L. D., Huang, C. L.-H., & Carpenter, T. A. (2000) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(00)00151-x · Cited by 149
Anisotropic noise propagation in diffusion tensor MRI sampling schemes
Batchelor, P. G., Atkinson, D., Hill, D., Calamante, F., & Connelly, A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10491 · Cited by 139
Optimal acquisition orders of diffusion‐weighted MRI measurements
Cook, P. A., Symms, M. R., Boulby, P. A., & Alexander, D. C. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20905 · Cited by 139
Partridge, S. C., Mukherjee, P., Berman, J., Henry, R. G., Miller, S. P., Lü, Y., Glenn, O. A., Ferriero, D. M., Barkovich, A. J., & Vigneron, D. B. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20410 · Cited by 135
Self-citationPotential and feasibility of parallel MRI at high field
Wiesinger, F., de Moortele, P. V., Adriany, G., Zanche, N. D., Uǧurbil, K., & Pruessmann, K. P. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1050 · Cited by 128
Turboprop: Improved PROPELLER imaging
Pipe, J. G., & Zwart, N. R. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20768 · Cited by 94
Nunes, R. G., Jezzard, P., & Clare, S. (2005) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2005.07.005 · Cited by 84
Optimized diffusion gradient orientation schemes for corrupted clinical DTI data sets
Dubois, J., Poupon, C., Lethimonnier, F., & Bihan, D. L. (2006) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-006-0036-0 · Cited by 81
Influence of SENSE on image properties in high‐resolution single‐shot echo‐planar DTI
Jaermann, T., Pruessmann, K., Valavanis, A., Kollias, S., & Boesiger, P. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20769 · Cited by 62
Niogi, S. N., Mukherjee, P., & McCandliss, B. D. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.10.040 · Cited by 60
Self-citationQuantification of mechanical vibration during diffusion tensor imaging at 3 T
Hiltunen, J., Hari, R., Jousmäki, V., Müller, K., SEPPONEN, R. E., & Joensuu, R. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.03.004 · Cited by 49
Armitage, P. A., & Bastin, M. E. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1140 · Cited by 47
Xu, D., Henry, R. G., Mukherjee, P., Carvajal, L., Miller, S. P., Barkovich, A., & Vigneron, D. (2004) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.01.075 · Cited by 47
Self-citationChuang, T., Huang, T., Lin, F., Wang, F., Juan, C., Chung, H., Chen, C., & Kwong, K. K. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21064 · Cited by 46
Triggering in Quantitative Diffusion Imaging with Single-Shot EPI
Brockstedt, S., Borg, M., Geijer, B., Wirestam, R., Thomsen, C., Holtås, S., & Ståhlberg, F. (1999) · Acta Radiologica · doi:10.3109/02841859909175552 · Cited by 44
Whole brain voxel-wise analysis of single-subject serial DTI by permutation testing
Chung, S., Pelletier, D., Sdika, M., Lü, Y., Berman, J., & Henry, R. G. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.10.039 · Cited by 35
Self-citationDevelopment and initial evaluation of 7-T q-ball imaging of the human brain
Mukherjee, P., Hess, C. P., Xu, D., Han, E. T., Kelley, D. A. C., & Vigneron, D. B. (2007) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.05.011 · Cited by 27
Self-citationSingle-shot fast spin-echo diffusion tensor imaging of the lumbar spine at 1.5 and 3 T
Carballido‐Gamio, J., Xu, D., Newitt, D. C., Han, E. T., Vigneron, D. B., & Majumdar, S. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2006.10.005 · Cited by 20
(1999) · doi:10.1002/1531-8249(199902)45:2<265::aid-ana21>3.0.co;2-3
Cited by
Imaging structural and functional brain development in early childhood
Gilmore, J. H., Knickmeyer, R. C., & Gao, W. (2018) · Nature Reviews Neuroscience · doi:10.1038/nrn.2018.1 · Cited by 1,013
A hitchhiker's guide to diffusion tensor imaging
Soares, J. M., Marques, P., Alves, V., & Sousa, N. (2013) · Frontiers in Neuroscience · doi:10.3389/fnins.2013.00031 · Cited by 893
Diffusion Tensor Imaging of Mild Traumatic Brain Injury
Niogi, S. N., & Mukherjee, P. (2010) · Journal of Head Trauma Rehabilitation · doi:10.1097/htr.0b013e3181e52c2a · Cited by 379
Self-citationDiffusion Tensor Imaging: A Review for Pediatric Researchers and Clinicians
Feldman, H. M., Yeatman, J. D., Lee, E. S., Barde, L. H. F., & Gaman-Bean, S. (2010) · Journal of Developmental & Behavioral Pediatrics · doi:10.1097/dbp.0b013e3181dcaa8b · Cited by 363
Heterogeneity in age-related white matter changes
Schmidt, R., Schmidt, H., Haybaeck, J., Loitfelder, M., Weis, S., Cavalieri, M., Seiler, S., Enzinger, C., Ropele, S., Erkinjuntti, T., et al. (2011) · Acta Neuropathologica · doi:10.1007/s00401-011-0851-x · Cited by 328
Metadata
- Authors
- Mukherjee, P., Chung, S. W., Berman, J. I., Hess, C. P., & Henry, R. G.
- Venue
- American Journal of Neuroradiology
- Published
- 2008-03-13
- Volume
- 29
- Issue
- 5
- Pages
- 843-852
- ISSN
- 0195-6108 (ISSN-L)
- 1936-959X
- OpenAlex
- W2115133411
- Cited by
- 390
- References
- 69
- FWCI
- 18.40
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.