The DOI matches its Crossref record; 108 of the 108 references it cites were found in a registry or an index.
EEG Source Imaging: A Practical Review of the Analysis Steps
Open accessAbstract
The electroencephalogram (EEG) is one of the oldest technologies to measure neuronal activity of the human brain. It has its undisputed value in clinical diagnosis, particularly (but not exclusively) in the identification of epilepsy and sleep disorders and in the evaluation of dysfunctions in sensory transmission pathways. With the advancement of digital technologies, the analysis of EEG has moved from pure visual inspection of amplitude and frequency modulations over time to a comprehensive exploration of the temporal and spatial characteristics of the recorded signals. Today, EEG is accepted as a powerful tool to capture brain function with the unique advantage of measuring neuronal processes in the time frame in which these processes occur, namely in the sub-second range. However, it is generally stated that EEG suffers from a poor spatial resolution that makes it difficult to infer to the location of the brain areas generating the neuronal activity measured on the scalp. This statement has challenged a whole community of biomedical engineers to offer solutions to localize more precisely and more reliably the generators of the EEG activity. High-density EEG systems combined with precise information of the head anatomy and sophisticated source localization algorithms now exist that convert the EEG to a true neuroimaging modality. With these tools in hand and with the fact that EEG still remains versatile, inexpensive and portable, electrical neuroimaging has become a widely used technology to study the functions of the pathological and healthy human brain. However, several steps are needed to pass from the recording of the EEG to 3-dimensional images of neuronal activity. This review explains these different steps and illustrates them in a comprehensive analysis pipeline integrated in a stand-alone freely available academic software: Cartool. The information about how the different steps are performed in Cartool is only meant as a suggestion. Other EEG source imaging software may apply similar or different approaches to the different steps.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371
Oostenveld, R., Fries, P., Maris, E., & Schoffelen, J.-M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/156869 · Cited by 10,323
Brainstorm: A User-Friendly Application for MEG/EEG Analysis
Tadel, F., Baillet, S., Mosher, J. C., Pantazis, D., & Leahy, R. M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/879716 · Cited by 3,677
Pascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869
Self-citationThe scientist and engineer's guide to digital signal processing
Smith, S. W. (1997) · Cited by 2,799
Spherical splines for scalp potential and current density mapping
Perrin, F., Pernier, J., Bertrand, O., & Echallier, J. F. (1989) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(89)90180-6 · Cited by 2,706
Nunez, P. L., & Srinivasan, R. (2006) · doi:10.1093/acprof:oso/9780195050387.001.0001 · Cited by 2,531
Interpreting magnetic fields of the brain: minimum norm estimates
Hämäläinen, M. S., & Ilmoniemi, R. J. (1994) · Medical & Biological Engineering & Computing · doi:10.1007/bf02512476 · Cited by 1,995
BioelectromagnetismPrinciples and Applications of Bioelectric and Biomagnetic Fields
Malmivuo, J., & Plonsey, R. (1995) · doi:10.1093/acprof:oso/9780195058239.001.0001 · Cited by 1,834
Delorme, A., Sejnowski, T., & Makeig, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.004 · Cited by 1,759 · cited 1×
“The ICA is used to detect and correct artifacts, particular eye movements, eye blinks and cardiac pulse artifacts (43).”
MethodBaillet, S., Mosher, J. C., & Leahy, R. M. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962275 · Cited by 1,692
Michel, C. M., Murray, M. M., Lantz, G., Gonzalez, S., Spinelli, L., & Grave de Peralta, R. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.06.001 · Cited by 1,655
Self-citationMultiple dipole modeling and localization from spatio-temporal MEG data
Mosher, J. C., Lewis, P. S., & Leahy, R. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141192 · Cited by 1,048
Helmholtz, H. (1853) · Annalen der Physik · doi:10.1002/andp.18531650603 · Cited by 989
Source connectivity analysis with MEG and EEG
Schoffelen, J., & Gross, J. (2009) · Human Brain Mapping · doi:10.1002/hbm.20745 · Cited by 850
Statistical parametric mapping
Friston, K. (2007) · Statistical Parametric Mapping · doi:10.1016/b978-012372560-8/50002-4 · Cited by 789
Towards the utilization of EEG as a brain imaging tool
Michel, C. M., & Murray, M. M. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.12.039 · Cited by 738
Self-citationSpatiotemporal Analysis of Multichannel EEG: CARTOOL
Brunet, D., Murray, M. M., & Michel, C. M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/813870 · Cited by 731
Self-citationEEGLAB, SIFT, NFT, BCILAB, and ERICA: New Tools for Advanced EEG Processing
Delorme, A., Mullen, T., Kothe, C., Akalin Acar, Z., Bigdely-Shamlo, N., Vankov, A., & Makeig, S. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/130714 · Cited by 643
EEG and MEG Data Analysis in SPM8
Litvak, V., Mattout, J., Kiebel, S., Phillips, C., Henson, R., Kilner, J., Barnes, G., Oostenveld, R., Daunizeau, J., Flandin, G., et al. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/852961 · Cited by 581
The standardized EEG electrode array of the IFCN
Seeck, M., Koessler, L., Bast, T., Leijten, F., Michel, C., Baumgartner, C., He, B., & Beniczky, S. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.06.254 · Cited by 489 · cited 1×
“It has therefore been recommended that at least 3 inferior electrodes on each side should be added to the standard 10–20 system in clinical routine (64).”
BackgroundSelf-citationIntrinsic Coupling Modes: Multiscale Interactions in Ongoing Brain Activity
Engel, A. K., Gerloff, C., Hilgetag, C. C., & Nolte, G. (2013) · Neuron · doi:10.1016/j.neuron.2013.09.038 · Cited by 471
The conductivity of the human skull: results of in vivo and in vitro measurements
Oostendorp, T. F., Delbeke, J., & Stegeman, D. F. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2000.880100 · Cited by 467
Methods of Analysis of Brain Electrical and Magnetic Signals
Gevins, A. S., & Rémond, A. (1987) · Medical Entomology and Zoology · Cited by 451
Biasiucci, A., Franceschiello, B., & Murray, M. M. (2019) · Current Biology · doi:10.1016/j.cub.2018.11.052 · Cited by 450
EEG Electrode Sensitivity-An Application of Reciprocity
Rush, S., & Driscoll, D. A. (1969) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1969.4502598 · Cited by 448
Electroencephalographic source imaging: a prospective study of 152 operated epileptic patients
Brodbeck, V., Spinelli, L., Lascano, A. M., Wissmeier, M., Vargas, M.-I., Vulliemoz, S., Pollo, C., Schaller, K., Michel, C. M., & Seeck, M. (2011) · Brain · doi:10.1093/brain/awr243 · Cited by 427
Self-citationElectrical neuroimaging based on biophysical constraints
Grave de Peralta Menendez, R., Murray, M. M., Michel, C. M., Martuzzi, R., & Gonzalez Andino, S. L. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.09.051 · Cited by 365
Self-citationElectric Dipole Tracing in the Brain by Means of the Boundary Element Method and Its Accuracy
He, B., Musha, T., Okamoto, Y., Homma, S., Nakajima, Y., & Sato, T. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326056 · Cited by 334
A critical assessment of connectivity measures for EEG data: A simulation study
Haufe, S., Nikulin, V. V., Müller, K.-R., & Nolte, G. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.09.036 · Cited by 334
Capturing the spatiotemporal dynamics of self-generated, task-initiated thoughts with EEG and fMRI
Bréchet, L., Brunet, D., Birot, G., Gruetter, R., Michel, C. M., & Jorge, J. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.03.029 · Cited by 329
Self-citationMagnetic brain source imaging of focal epileptic activity: a synopsis of 455 cases
Stefan, H. (2003) · Brain · doi:10.1093/brain/awg239 · Cited by 304
Electrophysiological Imaging of Brain Activity and Connectivity—Challenges and Opportunities
He, B., Yang, L., Wilke, C., & Yuan, H. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2139210 · Cited by 300
Wang, J.-Z., Williamson, S. J., & Kaufman, L. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.142641 · Cited by 299
A new interpretation of the generators of BAEP waves I–V: Results of a spatio-temporal dipole model
Scherg, M., & Von Cramon, D. (1985) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(85)90006-1 · Cited by 299
Electrophysiological source imaging: A noninvasive window to brain dynamics
He, B., Sohrabpour, A., Brown, E., & Liu, Z. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-120853 · Cited by 297
Subcortical electrophysiological activity is detectable with high-density EEG source imaging
Seeber, M., Cantonas, L.-M., Hoevels, M., Sesia, T., Visser-Vandewalle, V., & Michel, C. M. (2019) · Nature Communications · doi:10.1038/s41467-019-08725-w · Cited by 294
Self-citationEvaluation of Methods for Three-Dimensional Localization of Electrical Sources in the Human Brain
Kavanagk, R. N., Darcey, T. M., Lehmann, D., & Fender, D. H. (1978) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1978.326339 · Cited by 276
Effects of Forward Model Errors on EEG Source Localization
Akalin Acar, Z., & Makeig, S. (2013) · Brain Topography · doi:10.1007/s10548-012-0274-6 · Cited by 265
Scherg, M., & Picton, T. W. (1991) · PubMed · Cited by 254
EEG source localization in focal epilepsy: Where are we now?
Plummer, C., Harvey, A. S., & Cook, M. (2008) · Epilepsia · doi:10.1111/j.1528-1167.2007.01381.x · Cited by 252
Estimating the spatial Nyquist of the human EEG
Srinivasan, R., Tucker, D. M., & Murias, M. (1998) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03209412 · Cited by 247
Electric source imaging of human brain functions
Michel, C. M., Thut, G., Morand, S., Khateb, A., Pegna, A. J., Grave de Peralta, R., Gonzalez, S., Seeck, M., & Landis, T. (2001) · Brain Research Reviews · doi:10.1016/s0165-0173(01)00086-8 · Cited by 243
Self-citationFilter Effects and Filter Artifacts in the Analysis of Electrophysiological Data
Widmann, A., & Schröger, E. (2012) · Frontiers in Psychology · doi:10.3389/fpsyg.2012.00233 · Cited by 240
Electrophysiological Brain Connectivity: Theory and Implementation
He, B., Astolfi, L., Valdes-Sosa, P. A., Marinazzo, D., Palva, S. O., Benar, C.-G., Michel, C. M., & Koenig, T. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2913928 · Cited by 235
Self-citationHigh‐Frequency Oscillations in the Normal Human Brain
Frauscher, B., von Ellenrieder, N., Zelmann, R., Rogers, C., Nguyen, D. K., Kahane, P., Dubeau, F., & Gotman, J. (2018) · Annals of Neurology · doi:10.1002/ana.25304 · Cited by 232
eConnectome: A MATLAB toolbox for mapping and imaging of brain functional connectivity
He, B., Dai, Y., Astolfi, L., Babiloni, F., Yuan, H., & Yang, L. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.11.015 · Cited by 229
Goncalves, S. I., de Munck, J. C., Verbunt, J. P. A., Bijma, F., Heethaar, R. M., & Lopes da Silva, F. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.812164 · Cited by 219
Lai, Y., van Drongelen, W., Ding, L., Hecox, K. E., Towle, V. L., Frim, D. M., & He, B. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.08.017 · Cited by 215
BRUNIA, C. H. M., Mulder, G., & Verbaten, M. N. (1991) · Medical Entomology and Zoology · Cited by 204
Evaluation of Skull Cortical Thickness Changes With Age and Sex From Computed Tomography Scans
Lillie, E. M., Urban, J. E., Lynch, S. K., Weaver, A. A., & Stitzel, J. D. (2016) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2613 · Cited by 204
From EEG signals to brain connectivity: A model-based evaluation of interdependence measures
Wendling, F., Ansari-Asl, K., Bartolomei, F., & Senhadji, L. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.04.021 · Cited by 203
Ictal source analysis: Localization and imaging of causal interactions in humans
Ding, L., Worrell, G. A., Lagerlund, T. D., & He, B. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.09.042 · Cited by 183
Electromagnetic Inverse Solutions in Anatomically Constrained Spherical Head Models
Spinelli, L., Andino, S. G., Lantz, G., Seeck, M., & Michel, C. M. (2000) · Brain Topography · doi:10.1023/a:1026607118642 · Cited by 182
Self-citationMeasurement of the Conductivity of Skull, Temporarily Removed During Epilepsy Surgery
Hoekema, R., Wieneke, G. H., Leijten, F. S. S., van Veelen, C. W. M., van Rijen, P. C., Huiskamp, G. J. M., Ansems, J., & van Huffelen, A. C. (2003) · Brain Topography · doi:10.1023/a:1025606415858 · Cited by 179
A critical analysis of linear inverse solutions to the neuroelectromagnetic inverse problem
De Peralta-Menendez, R. G., & Gonzalez-Andino, S. L. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.664200 · Cited by 175
Critical Comments on EEG Sensor Space Dynamical Connectivity Analysis
de Steen, F. V., Faes, L., Karahan, E., Songsiri, J., Valdes-Sosa, P. A., & Marinazzo, D. (2016) · Brain Topography · doi:10.1007/s10548-016-0538-7 · Cited by 171
Dynamic directed interictal connectivity in left and right temporal lobe epilepsy
Coito, A. L., Plomp, G., Genetti, M., Abela, E., Wiest, R., Seeck, M., Michel, C. M., & Vulliémoz, S. (2015) · Epilepsia · doi:10.1111/epi.12904 · Cited by 165
Self-citationVolume Conduction Influences Scalp-Based Connectivity Estimates
Brunner, C., Billinger, M., Seeber, M., Mullen, T. R., & Makeig, S. (2016) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2016.00121 · Cited by 164
Scalp EEG is not a Blur: It Can See High Frequency Oscillations Although Their Generators are Small
Zelmann, R., Lina, J. M., Schulze-Bonhage, A., Gotman, J., & Jacobs, J. (2014) · Brain Topography · doi:10.1007/s10548-013-0321-y · Cited by 163
Conductivity of living intracranial tissues
Latikka, J., Kuurne, T., & Eskola, H. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/6/302 · Cited by 161
Electric source imaging of interictal activity accurately localises the seizure onset zone
Megevand, P., Spinelli, L., Genetti, M., Brodbeck, V., Momjian, S., Schaller, K., Michel, C. M., Vulliemoz, S., & Seeck, M. (2014) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp-2013-305515 · Cited by 160
Self-citationBaillet, S., Riera, J. J., Marin, G., Mangin, J. F., Aubert, J., & Garnero, L. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/1/306 · Cited by 159
Lascano, A. M., Perneger, T., Vulliémoz, S., Spinelli, L., Garibotto, V., Korff, C. M., Vargas, M. I., Michel, C. M., & Seeck, M. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.03.025 · Cited by 152
Self-citationThe localization of equivalent dipoles of EEG sources by the application of electrical field theory
Henderson, C. J., Butler, S. R., & Glass, A. (1975) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(75)90002-4 · Cited by 150
Impact of the reference choice on scalp EEG connectivity estimation
Chella, F., Pizzella, V., Zappasodi, F., & Marzetti, L. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036016 · Cited by 150
Coito, A. L., Genetti, M., Pittau, F., Iannotti, G. R., Thomschewski, A. C., Höller, Y., Trinka, E., Wiest, R., Seeck, M., Michel, C. M., et al. (2016) · Epilepsia · doi:10.1111/epi.13308 · Cited by 147
Self-citationEEG Source Imaging in Pediatric Epilepsy Surgery: A New Perspective in Presurgical Workup
Sperli, F., Spinelli, L., Seeck, M., Kurian, M., Michel, C. M., & Lantz, G. (2006) · Epilepsia · doi:10.1111/j.1528-1167.2006.00550.x · Cited by 141
Self-citationElectrical source imaging for presurgical focus localization in epilepsy patients with normal MRI
Brodbeck, V., Spinelli, L., Lascano, A. M., Pollo, C., Schaller, K., Vargas, M. I., Wissmeyer, M., Michel, C. M., & Seeck, M. (2010) · Epilepsia · doi:10.1111/j.1528-1167.2010.02521.x · Cited by 130
Self-citationMEG/EEG Source Reconstruction, Statistical Evaluation, and Visualization with NUTMEG
Dalal, S. S., Zumer, J. M., Guggisberg, A. G., Trumpis, M., Wong, D. D. E., Sekihara, K., & Nagarajan, S. S. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/758973 · Cited by 125
Head model and electrical source imaging: A study of 38 epileptic patients
Birot, G., Spinelli, L., Vulliémoz, S., Mégevand, P., Brunet, D., Seeck, M., & Michel, C. M. (2014) · NeuroImage Clinical · doi:10.1016/j.nicl.2014.06.005 · Cited by 125
Self-citationCatching the Invisible: Mesial Temporal Source Contribution to Simultaneous EEG and SEEG Recordings
Koessler, L., Cecchin, T., Colnat‐Coulbois, S., Vignal, J., Jonas, J., Vespignani, H., Ramantani, G., & Maillard, L. G. (2014) · Brain Topography · doi:10.1007/s10548-014-0417-z · Cited by 118
Does Filtering Preclude Us from Studying ERP Time-Courses?
Rousselet, G. A. (2012) · Frontiers in Psychology · doi:10.3389/fpsyg.2012.00131 · Cited by 117
Non-invasive localization of the epileptogenic focus by EEG dipole modeling
Ebersole, J. S. (1994) · Acta Neurologica Scandinavica · doi:10.1111/j.1600-0404.1994.tb05179.x · Cited by 117
Development of Volume Conductor and Source Models to Localize Epileptic Foci
Fuchs, M., Wagner, M., & Kastner, J. (2007) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e318038fb3e · Cited by 111
Academic Software Applications for Electromagnetic Brain Mapping Using MEG and EEG
Baillet, S., Friston, K. J., & Oostenveld, R. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/972050 · Cited by 107
Localizing Acute Stroke-related EEG Changes: Assessing the Effects of Spatial Undersampling
Luu, P., Tucker, D. M., Englander, R. N., Lockfeld, A. J., Lutsep, H. L., & Oken, B. (2001) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200107000-00002 · Cited by 98
Increase in cranial thickness during growth.
Af, R. (1953) · PubMed · Cited by 96
Imaging functional brain connectivity patterns from high‐resolution EEG and fMRI via graph theory
Astolfi, L., Fallani, F. D. V., Cincotti, F., Mattia, D., Marciani, M. G., Bufalari, S., Salinari, S., Colosimo, A., Ding, L., Edgar, J. C., et al. (2007) · Psychophysiology · doi:10.1111/j.1469-8986.2007.00556.x · Cited by 90
Interictal spike analysis of high-density EEG in patients with partial epilepsy
Wang, G., Worrell, G. A., Yang, L., Wilke, C. T., & He, B. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.10.043 · Cited by 85
Beyond the Double Banana: Improved Recognition of Temporal Lobe Seizures in Long-Term EEG
Rosenzweig, I., Fogarasi, A., Johnsen, B., Alving, J., Fabricius, M. E., Scherg, M., Neufeld, M. Y., Pressler, R., Kjær, T. W., Boas, W. V. E., et al. (2014) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0000000000000019 · Cited by 81
Ictal and interictal electric source imaging in pre‐surgical evaluation: a prospective study
Sharma, P., Scherg, M., Pinborg, L. H., Fabricius, M. E., Rubboli, G., Pedersen, B., Leffers, A.-M., Uldall, P. V., Jespersen, B., Brennum, J., et al. (2018) · European Journal of Neurology · doi:10.1111/ene.13676 · Cited by 77
Accuracy of EEG source imaging of epileptic spikes in patients with large brain lesions
Brodbeck, V., Lascano, A. M., Spinelli, L., Seeck, M., & Michel, C. M. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.01.011 · Cited by 76
Self-citationCoito, A., Michel, C. M., van Mierlo, P., Vulliemoz, S., & Plomp, G. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2619665 · Cited by 75
Self-citationInfraslow Electroencephalographic and Dynamic Resting State Network Activity
Grooms, J. K., Thompson, G. J., Pan, W.-J., Billings, J., Schumacher, E. H., Epstein, C. M., & Keilholz, S. D. (2017) · Brain Connectivity · doi:10.1089/brain.2017.0492 · Cited by 74
Ryynanen, O., Hyttinen, J., & Malmivuo, J. A. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873744 · Cited by 74
Lantz, G., Holub, M., Ryding, E., & Rosén, I. (1996) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0921-884x(96)95686-6 · Cited by 73
Seizure Onset Zone Localization from Ictal High-Density EEG in Refractory Focal Epilepsy
Staljanssens, W., Strobbe, G., Holen, R. V., Birot, G., Gschwind, M., Seeck, M., Vandenberghe, S., Vulliémoz, S., & van Mierlo, P. (2016) · Brain Topography · doi:10.1007/s10548-016-0537-8 · Cited by 73
Klamer, S., Elshahabi, A., Lerche, H., Braun, C., Erb, M., Scheffler, K., & Focke, N. K. N. (2014) · Brain Topography · doi:10.1007/s10548-014-0405-3 · Cited by 71
Automated EEG source imaging: A retrospective, blinded clinical validation study
Baroumand, A. G., van Mierlo, P., Strobbe, G., Pinborg, L. H., Fabricius, M. E., Rubboli, G., Leffers, A.-M., Uldall, P. V., Jespersen, B., Brennum, J., et al. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.09.015 · Cited by 65
Directed functional connections underlying spontaneous brain activity
Coito, A. L., Michel, C. M., Vulliémoz, S., & Plomp, G. (2018) · Human Brain Mapping · doi:10.1002/hbm.24418 · Cited by 62
Self-citationLocalization of cortico-peripheral coherence with electroencephalography
Guggisberg, A. G., Dalal, S. S., Zumer, J. M., Wong, D. D. E., Dubovik, S., Michel, C. M., & Schnider, A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.05.076 · Cited by 61
Self-citationMulti-Scale Neural Sources of EEG: Genuine, Equivalent, and Representative. A Tutorial Review
Nunez, P. L., Nunez, M. D., & Srinivasan, R. (2019) · Brain Topography · doi:10.1007/s10548-019-00701-3 · Cited by 59
Best Practices in Data Analysis and Sharing in Neuroimaging using MEEGPreprint
Pernet, C. R., Garrido, M. I., Gramfort, A., Maurits, N. M., Michel, C. M., Pang, E. W., Salmelin, R. H., Schoffelen, J., Valdes-Sosa, P. A., & Puce, A. (2018) · OSF Preprints (OSF Preprints) · doi:10.31219/osf.io/a8dhx · Cited by 59
Self-citationEffect of Skull Resistivity on the Spatial Resolutions of EEG and MEG
Malmivuo, J. A., & Suihko, V. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827255 · Cited by 54
Chowdhury, R. A., Merlet, I., Birot, G., Kobayashi, E., Nica, A., Biraben, A., Wendling, F., Lina, J.-M., Albera, L., & Grova, C. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.08.044 · Cited by 53
Kuhnke, N. G., Schwind, J., Dümpelmann, M., Mader, M., Schulze‐Bonhage, A., & Jacobs, J. (2018) · Brain Topography · doi:10.1007/s10548-018-0658-3 · Cited by 51
Probabilistic reconstruction of multiple sources in the bioelectromagnetic inverse problem
Greenblatt, R. E. (1993) · Inverse Problems · doi:10.1088/0266-5611/9/2/008 · Cited by 48
Feng, R., Hu, J., Pan, L., Wu, J., Lang, L., Jiang, S., Gu, X., Guo, J. X., & Zhou, L. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.03.009 · Cited by 34
Willemse, R. B., Hillebrand, A., Ronner, H. E., Vandertop, W. P., & Stam, C. J. (2015) · NeuroImage Clinical · doi:10.1016/j.nicl.2015.11.002 · Cited by 32
Added clinical value of the inferior temporal EEG electrode chain
Justesen, A. B., Johansen, A. B. E., Martinussen, N. I., Wasserman, D., Terney, D., Meritam, P., Gardella, E., & Beniczky, S. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.09.113 · Cited by 32
Lascano, A. M., Grouiller, F., Genetti, M., Spinelli, L., Seeck, M., Schaller, K., & Michel, C. M. (2014) · Neurosurgery · doi:10.1227/neu.0000000000000298 · Cited by 31
Self-citationAstolfi, L., Fallani, F. D. V., Cincotti, F., Mattia, D., Marciani, M. G., Salinari, S., Sweeney, J. A., Miller, G. A., He, B., & Babiloni, F. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2010472 · Cited by 28
Electrophysiological Neuroimaging
He, B., & Lian, J. (2007) · Springer eBooks · doi:10.1007/0-306-48610-5_7 · Cited by 24
A Preliminary Study on Precision Image Guidance for Electrode Placement in an EEG Study
Jeon, S., Chien, J., Song, C., & Hong, J. (2017) · Brain Topography · doi:10.1007/s10548-017-0610-y · Cited by 21
Multi-Scale Neural Sources of EEG: Genuine, Equivalent, and Representative. A Tutorial ReviewPreprint
Nunez, M. D., Nunez, M. D., & Srinivasan, R. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/391318 · Cited by 11
Data acquisition and pre-processing standards for electrical neuroimaging
Michel, C. M., & Brandeis, D. (2009) · Cambridge University Press eBooks · doi:10.1017/cbo9780511596889.005 · Cited by 10
Self-citationIdentification of epileptogenic networks from dense EEG: A model-based study
Hassan, M., Mheich, A., Biraben, A., Merlet, I., & Wendling, F. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319664 · Cited by 4
Cited by
Hyperscanning: A Valid Method to Study Neural Inter-Brain Underpinnings of Social Interaction
Czeszumski, A., Eustergerling, S., Lang, A., Menrath, D., Gerstenberger, M., Schuberth, S., Schreiber, F., Rendon, Z. Z., & König, P. (2020) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2020.00039 · Cited by 511
“Therefore, it is not dependent on blood oxygenation, and its temporal resolution is higher than other methods (Michel and Brunet, 2019).”
BackgroundTMS combined with EEG: Recommendations and open issues for data collection and analysis
Hernandez-Pavon, J. C., Veniero, D., Bergmann, T. O., Belardinelli, P., Bortoletto, M., Casarotto, S., Casula, E. P., Farzan, F., Fecchio, M., Julkunen, P., et al. (2023) · Brain Stimulation · doi:10.1016/j.brs.2023.02.009 · Cited by 238
A Review on P300 in Obsessive-Compulsive Disorder
Raggi, A., Lanza, G., & Ferri, R. (2021) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2021.751215 · Cited by 22
du Bois, N., Korik, A., Hodge, S., Hudson, L., Elahi, A. S., Bigirimana, A., Dayan, N., Sanchez-Bornot, J. M., McCann, A., Yelden, K., et al. (2026) · Communications Medicine · doi:10.1038/s43856-026-01574-x · Cited by 2
Metadata
- Authors
- Michel, C. M., & Brunet, D.
- Venue
- Frontiers in Neurology
- Publisher
- Frontiers Media SA
- Published
- 2019-04-04
- Volume
- 10
- Pages
- 325-325
- ISSN
- 1664-2295 (ISSN-L)
- OpenAlex
- W2927702442
- Cited by
- 705
- References
- 108
- FWCI
- 35.83
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.