Analysis of high-perimeter planar electrodes for efficient neural stimulation
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Planar electrodes are used in epidural spinal cord stimulation and epidural cortical stimulation. Electrode geometry is one approach to increase the efficiency of neural stimulation and reduce the power required to produce the level of activation required for clinical efficacy. Our hypothesis was that electrode geometries that increased the variation of current density on the electrode surface would increase stimulation efficiency. High-perimeter planar disk electrodes were designed with sinuous (serpentine) variation in the perimeter. Prototypes were fabricated that had equal surface areas but perimeters equal to two, three or four times the perimeter of a circular disk electrode. The interface impedance of high-perimeter prototype electrodes measured in vitro did not differ significantly from that of the circular electrode over a wide range of frequencies. Finite element models indicated that the variation of current density was significantly higher on the surface of the high-perimeter electrodes. We quantified activation of 100 model axons randomly positioned around the electrodes. Input-output curves of the percentage of axons activated as a function of stimulation intensity indicated that the stimulation efficiency was dependent on the distance of the axons from the electrode. The high-perimeter planar electrodes were more efficient at activating axons a certain distance away from the electrode surface. These results demonstrate the feasibility of increasing stimulation efficiency through the design of novel electrode geometries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243 · cited 2×
“, 2005), but charge capacity during short-duration pulses (∼100 μs) is limited by the rate of electron and ion transport (Cogan, 2008).”
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708 · cited 1×
“Charge per phase and charge density per phase are cofactors in the generation of neural damage (McCreery et al., 1988, 1990), and this relationship is described by: log log( ), Q A k Q ⎛ ⎝⎜ ⎞ ⎠⎟ = − (6) where Q is the charge per phase, A is the electrode area, and k is a constant derived from data…”
A model of safe levels for electrical stimulation
Shannon, R. V. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.126616 · Cited by 526 · cited 4×
“The proposed limit for nondamaging stimulation levels using circular disk electrodes was k = 1.5, but this value was estimated using geometrical (average) charge density over the electrode surface (Shannon, 1992).”
InfluentialAxons, but not cell bodies, are activated by electrical stimulation in cortical gray matter
Nowak, L. G., & Bullier, J. (1998) · Experimental Brain Research · doi:10.1007/s002210050304 · Cited by 492 · cited 1×
“Although both experimental studies (Nowak and Bullier, 1998a,b) and computational models (McIntyre and Grill, 1999) indicate that during extracellular stimulation, action potential initiation occurs in the axon, the impact of changes in geometry on the effi ciency of activating other neural…”
Criteria for the Selection of Materials for Implanted Electrodes
Geddes, L. A., & Roeder, R. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1581292 · Cited by 240 · cited 1×
“Further, the impedance properties of SS and Pt/Ir are similar because they both passivate to form oxides on their surface (Jaron et al., 1968; Geddes and Roeder, 2003).”
Comparison of neural damage induced by electrical stimulation with faradaic and capacitor electrodes
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. A. (1988) · Annals of Biomedical Engineering · doi:10.1007/bf02368010 · Cited by 163 · cited 1×
“Charge per phase and charge density per phase are cofactors in the generation of neural damage (McCreery et al., 1988, 1990), and this relationship is described by: log log( ), Q A k Q ⎛ ⎝⎜ ⎞ ⎠⎟ = − (6) where Q is the charge per phase, A is the electrode area, and k is a constant derived from data…”
Cited by
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Tissue damage thresholds during therapeutic electrical stimulation
Cogan, S. F., Ludwig, K. A., Welle, C. G., & Takmakov, P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/021001 · Cited by 386
Safety of long-term electrical peripheral nerve stimulation: review of the state of the art
Günter, C., Delbeke, J., & Ortiz-Catalan, M. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0474-8 · Cited by 198
Regenerated sciatic nerve axons stimulated through a chronically implanted macro-sieve electrode
MacEwan, M. R., Zellmer, E. R., Wheeler, J. J., Burton, H., & Moran, D. W. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00557 · Cited by 48
“Compared to functional electrical stimulation of muscle tissue, stimulation of peripheral nerves requires lower excitation thresholds and enables recruitment of multiple distinct muscles with a single implanted electrode (Wei and Grill, 2009).”
Background
Metadata
- Authors
- Wei, X.
- Venue
- Frontiers in Neuroengineering
- Publisher
- Frontiers Media SA
- Published
- 2009
- Volume
- 2
- Pages
- 15-15
- ISSN
- 1662-6443 (ISSN-L)
- OpenAlex
- W2089863860
- Cited by
- 60
- References
- 7
- FWCI
- 0.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.