The DOI matches its Crossref record; 118 of the 118 references it cites were found in a registry or an index.
Wearable Biosensors for Non-Invasive Sweat Diagnostics
Open accessAbstract
Recent advances in microfluidics, microelectronics, and electrochemical sensing methods have steered the way for the development of novel and potential wearable biosensors for healthcare monitoring. Wearable bioelectronics has received tremendous attention worldwide due to its great a potential for predictive medical modeling and allowing for personalized point-of-care-testing (POCT). They possess many appealing characteristics, for example, lightweight, flexibility, good stretchability, conformability, and low cost. These characteristics make wearable bioelectronics a promising platform for personalized devices. In this paper, we review recent progress in flexible and wearable sensors for non-invasive biomonitoring using sweat as the bio-fluid. Real-time and molecular-level monitoring of personal health states can be achieved with sweat-based or perspiration-based wearable biosensors. The suitability of sweat and its potential in healthcare monitoring, sweat extraction, and the challenges encountered in sweat-based analysis are summarized. The paper also discusses challenges that still hinder the full-fledged development of sweat-based wearables and presents the areas of future research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures
![Figure 1 Wearable and flexible sensors for continuous biofluids analysis. (a) Soft PDMS contact lens with a glucose-sensing strip attached. Reproduced with permission from ref. [75], Copyright from 2020, Elsevier B.V. (b) All-printed tattoo-based ISF glucose sensor. Reproduced with permission from ref. [49], Copyright 2015, American Chemical Society. (c) Dynamic nanoparticle-based breath sensor. Reproduced with permission from ref. [78], Copyright from 2015, American Chemical Society. (d) Bacteria sensing on tooth enamel with graphene-based nanosensors. Reproduced with permission from ref. [79], Copyright from 2012, Nature Publishing Group. (e) Smart bandage for chemical sensing of wound pH using pH-sensitive threads. CMOS wireless readout and 2D mapping of pH levels were incorporated Reproduced with permission from ref. [74], Copyright 2017 IEEE. (f) Diabetes patch is composed of sweat-control (i, ii), sensing (iii–vii) and therapy (viii–x) components. (g) Integrated wearable diabetes monitoring and therapy system. (h) The electrochemical device on the human skin with perspiration. Reproduced with permission from ref. [80], Copyright from 2016, Nature Publishing Group.](/paper-figures/8f85337129d74a14a9992324a37bef7f/wearable-biosensors-for-non-invasive-sweat-diagnostics-figure-1.jpg)
![Figure 2 Sweat gland structure and biomarker partitioning. (a) Illustration of the sweat production process and metabolites that passed along with sweat. (b) Depiction of Iontophoresis to stimulate local sweat secretion at a selected site. (c) Reverse iontophoresis drives interstitial fluid through the epidermis to the skin surface. Reproduced with permission from ref. [69], Copyright from 2018, Nature Publishing Group.](/paper-figures/97fc16914cfc480ea5b6ef3a5301258a/wearable-biosensors-for-non-invasive-sweat-diagnostics-figure-2.jpg)
![Figure 3 Sweat-based sensors for continuous health monitoring. (a) Describes the working of the device and shows the developed FTENG to power device. (b) Schematic of the sensor array. (c) Schematic of microfluidic sensor patch. (d,e) Open-circuit potential responses of the pH sensor in standard Mcllvaine’s buffer solutions (d) and a sodium ion sensor in NaCl solutions (e). Reproduced with permission from ref. [107], Copyright from 2020, the American Association for the Advancement of Science.](/paper-figures/19fe8845cca346489e8b3c6d51e09e27/wearable-biosensors-for-non-invasive-sweat-diagnostics-figure-3.jpg)
![Figure 4 Overview of the developed CF monitoring device. (a) Electrodes used for iontophoresis and sensing. (b) Flexible wearable device on user’s wrist. (c,d) Description of the working modes of system (c) mode 1: Iontophoresis (d) mode 2: Sensing. (e) Block-level diagram of the developed system. (f) Real-time on-body measurement of sweat sodium ion and chloride ion levels of a CF patient after iontophoresis-based sweat stimulation. (g) Comparison of sweat electrolyte levels between six healthy subjects and three CF patients. Reproduced with permission from ref. [93], Copyright 2017, National Academy of Sciences USA.](/paper-figures/d99b5c3cf6f34b8fa31dc53f7065c5fb/wearable-biosensors-for-non-invasive-sweat-diagnostics-figure-4.jpg)
![Figure 5 Sweat-based sensors for exercise monitoring. (a) Subject wearing forehead and wrist sensors undergoing stationary exercise. (b) Flexible integrated sensor array shown on a subject’s wrist as part of a wireless FPCB. (c) Schematic of the sensor array. (d) System-level block diagram illustrating the flow of information. (e) Real-time sweat analysis results of the FISA worn on a subject’s forehead. (f) Constant-load exercise at 150 W: power output, heart rate (in beats per minute, b.p.m.), oxygen consumption and pulmonary minute ventilation, as measured by external monitoring systems. Reproduced with permission from ref. [44], Copyright from 2016, Nature Publishing Group.](/paper-figures/34c53b39f9004bafb6e7551844505bd2/wearable-biosensors-for-non-invasive-sweat-diagnostics-figure-5.jpg)
![Figure 6 Sweat-based multimodal sensor patch for exercise monitoring. (a) Step-by-step process of fabrication and complete sensor patch prototype. (b) Fabrication of specialized sensing threads. (c–f) Measurement results of different biomarkers. Reproduced with permission from ref. [116], Copyright from 2020, Nature Publishing Group.](/paper-figures/d4efaf3d44aa4cc78813ce34baa2877c/wearable-biosensors-for-non-invasive-sweat-diagnostics-figure-6.jpg)
![Figure 7 Drug sensing mechanism and ethanol levels measurement. (a) Interaction of the sensor with sweat. (b) Cycling and sweat analysis. Examples of sweat levodopa concentrations for three different subjects after they consume 450 g of fava beans. (c) Averaged time of peak levodopa concentration for three different subjects across multiple exercise trials. (d) Optical image of the S-band worn on a subject’s wrist. Reproduced with permission from ref. [99], Copyright from 2019, American Chemical Society. (e) Sweat ethanol sensor used to send alerts to a smart device. (f) Schematic diagram of constituents in the iontophoretic system (left) and of the reagent layer and processes involved in the amperometric sensing of ethanol on the working electrode (right). (g–i) Experiments with consumption of 12 oz of beer measured from three different human subjects before (plot “a”) and after drinking alcohol beverage (plot “b”). (j) Chronoamperograms obtained from a: BAC 0%, b: BAC 0.025% and c: BAC 0.062%. (k) Correlation between current response and the BAC level. Reproduced with permission from ref. [101], Copyright from 2016, American Chemical Society.](/paper-figures/34b91b94ee394b7dba7491b1f2b75267/wearable-biosensors-for-non-invasive-sweat-diagnostics-figure-7.jpg)
![Figure 8 Sweat-based sensors for biomolecules monitoring. (a) Schematic showing a stretchable chemical immunosensor for TNF-α cytokine sensing. (b) Schematic illustration of the TNF-α cytokine proteins immobilized on the working electrode for electrochemical sensing. (c) Image of fabricated device arrays. Reproduced with permission from ref. [103], Copyright from 2019, Elsevier. (d) Schematic illustration of cortisol in sweat and saliva. CRH, corticotropin-releasing hormone; ACTH, adrenocorticotropic hormone. (e) Schematic showing the light and dark cycle for regulating circadian rhythm and controlling of cortisol transport to sweat. (f) Cortisol levels in serum, saliva, and sweat at different times from a healthy subject. Reproduced with permission from ref. [27], Copyright from 2020, Elsevier.](/paper-figures/93a890647b17476aa335ffc2c1d58043/wearable-biosensors-for-non-invasive-sweat-diagnostics-figure-8.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The same temporal change of cortisol concentration was also reported for all biofluids, such as saliva, serum, and sweat.[ 8 , 30 ]”
From MicroSweat: A wearable microfluidic patch for noninvasive and reliable sweat collection enables human stress monitoring (2023) · cites this paper as [30]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087 · cited 7×
“For example, diabetes is directly related to the metabolite profile of glucose, which can be easily detected through sweat [44,98].”
BackgroundMethodInfluentialLee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315 · cited 5×
“Moreover, because the concentration of chlorine in the sweat of patients who have cystic fibrosis (CF) is abnormally high, the analysis of chlorine in sweat has been regarded as a widely used method for the diagnosis of CF [74].”
BackgroundMethodInfluentialA soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
A laser-engraved wearable sensor for sensitive detection of uric acid and tyrosine in sweat
Yang, Y., Song, Y., Bo, X., Min, J., Pak, O. S., Zhu, L., Wang, M., Tu, J., Kogan, A., Zhang, H., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-019-0321-x · Cited by 1,270
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Lee, H., Song, C., Hong, Y. S., Kim, M., Cho, H. R., Kang, T., Shin, K., Choi, S. H., Hyeon, T., & Kim, D.-H. (2017) · Science Advances · doi:10.1126/sciadv.1601314 · Cited by 1,118
Self-powered ultra-flexible electronics via nano-grating-patterned organic photovoltaics
Park, S., Heo, S. W., Lee, W., Inoue, D., Jiang, Z., Yu, K., Jinno, H., Hashizume, D., Sekino, M., Yokota, T., et al. (2018) · Nature · doi:10.1038/s41586-018-0536-x · Cited by 1,068
Graphene-based wireless bacteria detection on tooth enamel
Mannoor, M. S., Tao, H., Clayton, J. D., Sengupta, A., Kaplan, D. L., Naik, R. R., Verma, N., Omenetto, F. G., & McAlpine, M. C. (2012) · Nature Communications · doi:10.1038/ncomms1767 · Cited by 1,014
Research works printed but not linked: 1
- Xiao, X., Xiao, X., Nashalian, A., Libanori, A., Fang, Y., Li, X., and Chen, J. (2021). Triboelectric Nanogenerators for Self-Powered Wound Healing. Adv. Healthc. Mater. · DOI
Cited by
Sorted by citations
Wearable and flexible electrochemical sensors for sweat analysis: a review
Gao, F., Liu, C., Zhang, L., Liu, T., Wang, Z., Song, Z., Cai, H., Fang, Z., Chen, J., Wang, J., et al. (2022) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00443-6 · Cited by 829
Self-citationPiezoelectric nanogenerators for personalized healthcare
Deng, W., Zhou, Y., Libanori, A., Chen, G., Yang, W., & Chen, J. (2022) · Chemical Society Reviews · doi:10.1039/d1cs00858g · Cited by 444
Self-citationVo, D.-K., & Trinh, K. T. L. (2024) · Biosensors · doi:10.3390/bios14110560 · Cited by 270
Advances in Wearable Strain Sensors Based on Electrospun Fibers
Gao, Z., Xiao, X., Carlo, A. D., Yin, J., Wang, Y., Huang, L., Tang, J., & Chen, J. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202214265 · Cited by 198
Self-citationResearch progress of electronic nose technology in exhaled breath disease analysis
Li, Y., Wei, X., Zhou, Y., Wang, J., & You, R. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00594-0 · Cited by 168
Advances in Machine Learning for Wearable Sensors
Xiao, X., Yin, J., Xu, J. H., Tat, T., & Chen, J. (2024) · ACS Nano · doi:10.1021/acsnano.4c05851 · Cited by 152
Self-citationSelf-powered environmental monitoring via a triboelectric nanogenerator
Chang, A., Uy, C., Xiao, X., Xiao, X., & Chen, J. (2022) · Nano Energy · doi:10.1016/j.nanoen.2022.107282 · Cited by 143
Self-citationCan Wearable Sweat Lactate Sensors Contribute to Sports Physiology?
Hoovels, K. V., Xuan, X., Cuartero, M., Gijssel, M., Swarén, M., & Crespo, G. A. (2021) · ACS Sensors · doi:10.1021/acssensors.1c01403 · Cited by 136
Lorestani, F., Zhang, X., Abdullah, A. M., Xin, X., Liu, Y., Rahman, M. M., Biswas, M. A. S., Li, B., Dutta, A., Niu, Z., et al. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202306117 · Cited by 126
The LOD paradox: When lower isn't always better in biosensor research and development
Moulahoum, H., & Ghorbanizamani, F. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116670 · Cited by 132
Zou, Y., Chu, Z., Guo, J., Liu, S., Ma, X., & Guo, J. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115103 · Cited by 120
Highly integrated watch for noninvasive continual glucose monitoring
Chang, T., Li, H., Zhang, N., Jiang, X., Yu, X., Yang, Q., Jin, Z., Meng, H., & Chang, L. (2022) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00355-5 · Cited by 115
Review of Stress Detection Methods Using Wearable Sensors
Taskasaplidis, G. V., Fotiadis, D. A., & Bamidis, P. D. (2024) · IEEE Access · doi:10.1109/access.2024.3373010 · Cited by 131
Smartphone-Based Multiplexed Biosensing Tools for Health Monitoring
Bedük, T., Beduk, D., Hasan, M. R., Guler, E., Kosel, J., Narang, J., Salama, K. N., & Tımur, S. (2022) · Biosensors · doi:10.3390/bios12080583 · Cited by 109
Das, R., Nag, S., & Banerjee, P. (2023) · Molecules · doi:10.3390/molecules28031259 · Cited by 92
Machine-Learning-Aided Self-Powered Assistive Physical Therapy Devices
Xiao, X., Fang, Y., Xiao, X., Xu, J. H., & Chen, J. (2021) · ACS Nano · doi:10.1021/acsnano.1c10676 · Cited by 86
Self-citationAdvanced Textile-Based Wearable Biosensors for Healthcare Monitoring
Li, S., Li, H., Lu, Y., Zhou, M., Jiang, S., Du, X., & Guo, C. (2023) · Biosensors · doi:10.3390/bios13100909 · Cited by 92
Recent advancements in machine learning enabled portable and wearable biosensors
Kadian, S., Kumari, P., Shukla, S., & Narayan, R. J. (2023) · Talanta Open · doi:10.1016/j.talo.2023.100267 · Cited by 85
Jarnda, K. V., Wang, D., Qurrat-Ul-Ain, Anaman, R., Johnson, V. E., Roberts, G. P., Johnson, P. S., Jallawide, B. W., Kai, T., & Ding, P. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114778 · Cited by 83
Yang, Q., Rosati, G., Abarintos, V., Aroca, M. A., Osma, J. F., & Merkoçi, A. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114005 · Cited by 85
A review of sampling, energy supply and intelligent monitoring for long-term sweat sensors
Yang, P., Wei, G., Liu, A., Huo, F., & Zhang, Z. (2022) · npj Flexible Electronics · doi:10.1038/s41528-022-00165-9 · Cited by 77
Machín, A., & Márquez, F. (2025) · Chemosensors · doi:10.3390/chemosensors13090345 · Cited by 80
Microneedle sensors for dermal interstitial fluid analysis
Kim, G., Ahn, H., Ulloa, J. C., & Gao, W. F. (2024) · Med-X · doi:10.1007/s44258-024-00028-0 · Cited by 81
Yang, M., Sun, N., Lai, X., Wu, J., Wu, L., Zhao, X., & Feng, L. (2023) · ACS Sensors · doi:10.1021/acssensors.2c02016 · Cited by 72
Mukasa, D., Wang, M., Min, J., Yang, Y., Solomon, S. A., Han, H., Ye, C., & Gao, W. F. (2023) · Advanced Materials · doi:10.1002/adma.202212161 · Cited by 73
Multifunctional MXenes nanocomposite platforms for biosensing and wearable sensor technologies
Amani, A. M., Kamyab, H., Vafa, E., Jahanbin, A., Abbasi, M., Vaez, A., Munuswamy‐Ramanujam, G., Ravindran, B., Gnanasekaran, L., Rocchio, D., et al. (2024) · Advanced Composites and Hybrid Materials · doi:10.1007/s42114-024-01118-8 · Cited by 68
Jarnda, K. V., Dai, H., Ali, A., Bestman, P. L., Trafiałek, J., Roberts-Jarnda, G. P., Anaman, R., Kamara, M. G., Wu, P., & Ding, P. (2025) · Biosensors · doi:10.3390/bios15040222 · Cited by 71
Pérez, D., & Orozco, J. (2022) · Microchimica Acta · doi:10.1007/s00604-022-05228-2 · Cited by 67
Roadmap on printable electronic materials for next-generation sensors
Pecunia, V., Petti, L., Andrews, J. B., Ollearo, R., Gelinck, G. H., Nasrollahi, B., Jailani, J. M., Li, N., Kim, J. H., Ng, T. N., et al. (2024) · Nano Futures · doi:10.1088/2399-1984/ad36ff · Cited by 66
Triboelectric Nanogenerators for Self-Powered Breath Monitoring
Shen, S., Xiao, X., Xiao, X., & Chen, J. (2021) · ACS Applied Energy Materials · doi:10.1021/acsaem.1c02465 · Cited by 60
Self-citationKhonina, S. N., & Kazanskiy, N. L. (2025) · Sensors · doi:10.3390/s25051367 · Cited by 58
3D-Printed Flexible Microfluidic Health Monitor for In Situ Sweat Analysis and Biomarker Detection
Chen, C., Fu, Y., Sparks, S. S., Lyu, Z., Pradhan, A., Ding, S., Boddeti, N., Liu, Y., Lin, Y., Du, D., et al. (2024) · ACS Sensors · doi:10.1021/acssensors.4c00528 · Cited by 61
Shajari, S., Salahandish, R., Zare, A., Hassani, M., Moossavi, S., Munro, E., Rashid, R., Rosenegger, D., Bains, J. S., & Sanati Nezhad, A. (2023) · Advanced Science · doi:10.1002/advs.202204171 · Cited by 55
Khan, A., Haque, M. N., Kabiraz, D. C., Yeasin, A., Rashid, H. A., Sarker, A. C., & Hossain, G. (2022) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2022.114093 · Cited by 57
Zhang, S., Suresh, L., Yang, J., Zhang, X., & Tan, S. C. (2022) · Advanced Intelligent Systems · doi:10.1002/aisy.202100194 · Cited by 56
Nanostructured wearable electrochemical and biosensor towards healthcare management: a review
Khaleque, M. A., Hossain, M. I., Ali, M. R., Bacchu, M. S., Aly, M. A. S., & Khan, M. Z. H. (2023) · RSC Advances · doi:10.1039/d3ra03440b · Cited by 54
Emerging Wearable Biosensor Technologies for Stress Monitoring and Their Real-World Applications
Wu, J., Ching, C. T., Wang, H., & Liao, L. (2022) · Biosensors · doi:10.3390/bios12121097 · Cited by 54
Progress in nanoparticle-based electrochemical biosensors for hormone detection
Rossi, F., Trakoolwilaiwan, T., Gigli, V., Tortolini, C., Lenzi, A., Isidori, A. M., Thanh, N. T. K., & Antiochia, R. (2024) · Nanoscale · doi:10.1039/d4nr02075h · Cited by 50
A Comprehensive Review of the Recent Developments in Wearable Sweat-Sensing Devices
Ibrahim, N. F. A., Sabani, N. B., Johari, S., Manaf, A. A., Wahab, A. A., Zakaria, Z., & Noor, A. M. (2022) · Sensors · doi:10.3390/s22197670 · Cited by 53
Akter, A., Apu, M. M. H., Veeranki, Y. R., Baroud, T. N., & Posada-Quintero, H. F. (2024) · Journal of Sensor and Actuator Networks · doi:10.3390/jsan13040040 · Cited by 51
Khan, A., Winder, M., & Hossain, G. (2021) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2021.100103 · Cited by 52
Alexandre-Franco, M. F., Kouider, R., Alkarany, R. A.-K., Correa, E. M. C., & Abdulla, A. A.-K. (2024) · Micromachines · doi:10.3390/mi15091137 · Cited by 51
Bilbao, E., Garate, O. F., Campos, T. R., Roberti, M., Mass, M., Lozano, A., Longinotti, G., Monsalve, L. N., & Ybarra, G. (2023) · Chemosensors · doi:10.3390/chemosensors11040244 · Cited by 47
Wearable sensors for monitoring chronic kidney disease
Han, S., Yamamoto, S., Jung, C., Jin, D. Y., Lee, T., & Kim, J. (2024) · Communications Materials · doi:10.1038/s43246-024-00606-0 · Cited by 50
Tiwari, N., Chatterjee, S., Kaswan, K., Chung, J.-H., Fan, K., & Lin, Z. (2022) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2022.116064 · Cited by 45
Chiappim, W., Fraga, M. A., Furlan, H., Saravia, D. C. A., & Pessoa, R. S. (2022) · Microsystem Technologies · doi:10.1007/s00542-022-05269-w · Cited by 39
Eco-Friendly Conductive Hydrogels: Towards Green Wearable Electronics
Moreno, J. M. C., Chelu, M., & Popa, M. (2025) · Gels · doi:10.3390/gels11040220 · Cited by 41
Chen, Y.-J., Hsu, Y., Tain, Y., Li, N., Pang, H., Kuo, S., & Yang, H. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114234 · Cited by 39
Xiao, G., Ju, J., Li, M., Wu, H., Jian, Y., Sun, W., Wang, W., Li, C. M., Qiao, Y., & Lu, Z. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115389 · Cited by 38
Lyzwinski, L. N., Elgendi, M., Shokurov, A. V., Cuthbert, T. J., Ahmadizadeh, C., & Menon, C. (2023) · Communications Engineering · doi:10.1038/s44172-023-00097-w · Cited by 39
Liu, Y., Hu, S., Gan, N., & Yu, Z. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.4c04271 · Cited by 38
Bioinspired nanomaterials for wearable sensing and human-machine interfacing
Kashyap, V., Yin, J., Xiao, X., & Chen, J. (2023) · Nano Research · doi:10.1007/s12274-023-5725-8 · Cited by 35
Self-citationKansay, V., Sharma, V. D., Srivastava, V., Batra, N., Chakrabarti, S., & Bera, M. K. (2024) · Microchemical Journal · doi:10.1016/j.microc.2024.110624 · Cited by 33
de Campos, A. M., da Silva, R. R., Calegaro, M. L., & Raymundo‐Pereira, P. A. (2022) · Chemosensors · doi:10.3390/chemosensors10110446 · Cited by 33
Fueling the Future: The Emergence of Self-Powered Enzymatic Biofuel Cell Biosensors
Gupta, A. K., & Krasnoslobodtsev, A. V. (2024) · Biosensors · doi:10.3390/bios14070316 · Cited by 33
Ren, J., Li, Q., Feng, K., Gong, J., Li, Z., Liu, X., Li, Y., & Zhang, J. (2024) · Talanta · doi:10.1016/j.talanta.2024.127236 · Cited by 33
Ma, R., Shao, R., An, X., Zhang, Q., & Sun, S. (2022) · Journal of Materials Chemistry B · doi:10.1039/d2tb00749e · Cited by 34
Ma, C., Shang, X., Zhu, Z., Zheng, L., Sun, M., Cao, M., Bai, J., Du, Y., & Zhou, M. (2024) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2024.117889 · Cited by 32
Nanoarchitectonics of point-of-care diagnostics for sweat biomarkers analysis
Lin, X., Vasanth, A., Ashok, A., Phan, H., Koo, K. M., Amin, M. A., Kaneti, Y. V., Salomón, C., Hossain, M. S. A., Yamauchi, Y., et al. (2024) · Nano Materials Science · doi:10.1016/j.nanoms.2024.01.010 · Cited by 29
Continuous and Non-Invasive Lactate Monitoring Techniques in Critical Care Patients
Lafuente, J. L., González, S., Aibar, C., Rivera, D., Avilés, E., & Beunza, J. J. (2024) · Biosensors · doi:10.3390/bios14030148 · Cited by 29
Zhang, S., He, Z., Zhao, W., Liu, C., Zhou, S., Ibrahim, O. O., Wang, C., & Wang, Q. (2024) · Nanomaterials · doi:10.3390/nano14100857 · Cited by 29
Daboss, E. V., Tikhonov, D. V., Shcherbacheva, E. V., & Karyakin, A. A. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c02208 · Cited by 29
Faura, G., Boix‐Lemonche, G., Holmeide, A. K., Verkauskienė, R., Volke, V., Sokolovska, J., & Petrovski, G. (2022) · Sensors · doi:10.3390/s22030718 · Cited by 26
Rao, L. T., Mandal, C. K., & Patolsky, F. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202503096 · Cited by 30
From new materials to advanced biomedical applications of solid-state biosensor: A review
Tabata, M., & Miyahara, Y. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.131033 · Cited by 25
The marriage of biochemistry and nanotechnology for non-invasive real-time health monitoring
Ji, D., Guo, X., Fu, W., Ding, Z., Wang, C., Zhang, Q., Ramakrishna, S., & Qin, X. (2022) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2022.100681 · Cited by 27
Nafion based biosensors: a review of recent advances and applications
Kakhki, R. M. (2023) · International Journal of Polymeric Materials · doi:10.1080/00914037.2023.2297436 · Cited by 25
Shen, Y., Wang, F., Li, Y., Li, J., Shi, X., Yang, Y., Yang, H., Cai, R., & Tan, W. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.4c02751 · Cited by 24
Liang, X., Zhang, S., Meng, S., Tan, R., Zhang, K., & Hu, J. (2024) · Microchemical Journal · doi:10.1016/j.microc.2024.111690 · Cited by 24
Wan, J., Xu, S., Lin, J., Ji, L., Cheng, J., Li, Z., Qu, X., & Li, C. (2025) · Small · doi:10.1002/smll.202504078 · Cited by 27
Biochips on the Move: Emerging Trends in Wearable and Implantable Lab-on-Chip Health Monitors
Kazanskiy, N. L., Khorin, P. A., & Khonina, S. N. (2025) · Electronics · doi:10.3390/electronics14163224 · Cited by 29
Li, P., Li, Z., Chen, H., Zhu, Y., Yang, D., & Hou, Y. (2023) · Sensors · doi:10.3390/s23177473 · Cited by 24
Oxygen Saturation Behavior by Pulse Oximetry in Female Athletes: Breaking Myths
Martín-Escudero, P., Cabanas, A. M., Fuentes, M. E., & Galindo-Canales, M. (2021) · Biosensors · doi:10.3390/bios11100391 · Cited by 25
Daboss, E. V., Shcherbacheva, E. V., & Karyakin, A. A. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.133337 · Cited by 23
An Integrated Paper‐Based Patch for Wearable Detection of Diabetic Nephropathy Biomarkers in Sweat
Zhang, S., Wang, H., Zheng, Y., Yao, Y., Li, T., Ma, Y., Zhou, Y., Chen, Z., Wei, Y., Lü, F., et al. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202501970 · Cited by 21
Parvin, N., Joo, S., Jung, J. H., & Mandal, T. K. (2025) · Actuators · doi:10.3390/act14060257 · Cited by 20
Wang, M., Lin, B., Chen, Y., Liu, H., Ju, Z., & Lv, R. (2024) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.3c01682 · Cited by 21
Kolawole, T. A., Palacios, J. C., Husaini, D. C., & Nwokocha, C. R. (2025) · Journal of Applied Toxicology · doi:10.1002/jat.4874 · Cited by 23
Wearable sensors for health monitoring: Current applications, trends, and future directions
Kurul, F., Aydoğan, D., Janat, S., Kirlangiç, İ. A., Kaya, H. O., & Topkaya, S. N. (2025) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2025.100727 · Cited by 22
Thought on Food: A Systematic Review of Current Approaches and Challenges for Food Intake Detection
Neves, P. A. C. S., Simões, J., Costa, R., Pimenta, L., Gonçalves, N. J., Albuquerque, C., Cunha, C. A. D. S., Zdravevski, E., Lameski, P., García, N. M., et al. (2022) · Sensors · doi:10.3390/s22176443 · Cited by 19
Ma, J., Li, H., Anwer, S., Umer, W., Antwi‐Afari, M. F., & Xiao, E. B. (2024) · International Journal of Occupational Safety and Ergonomics · doi:10.1080/10803548.2024.2330242 · Cited by 20
Yang, M., Sun, N., Lai, X., Zhao, X., & Zhou, W. (2023) · Biosensors · doi:10.3390/bios14010017 · Cited by 18
Cai, Z., Xiao, X., Wei, Y. Z., & Yin, J. (2025) · Biomacromolecules · doi:10.1021/acs.biomac.4c01709 · Cited by 17
Dashtian, K., Hajati, S., Ghaedi, M., Rashid, M., Qaretapeh, M. Z., & Rahimi‐Nasrabadi, M. (2025) · Journal of Materials Chemistry B · doi:10.1039/d5tb00095e · Cited by 17
Capillary-osmotic wearable patch based on lateral flow assay for sweat potassium analysis
Mukherjee, S., Salazar, S. P., Saha, T., Dickey, M. D., & Velev, O. D. (2024) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2024.136383 · Cited by 17
Bio-based nanomaterials for smart and sustainable nano-biosensing and therapeutics
Malode, S. J., Akhdar, H., Alodhayb, A. N., & Shetti, N. P. (2025) · Industrial Crops and Products · doi:10.1016/j.indcrop.2025.121603 · Cited by 16
Wearable Biosensor Standardization: How to Make Them Smarter
Giorgi, G. B. D., & Tonello, S. (2022) · Standards · doi:10.3390/standards2030025 · Cited by 16
Bioinspired Materials for Wearable Diagnostics and Biosensors
Bardhan, N. M., Radisic, M., & Nurunnabi, M. (2023) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.3c00348 · Cited by 17
Dermal-fluid-enabled detection platforms for non-invasive ambulatory monitoring
Veronica, A., Li, Y., Li, Y., Hsing, I., & Nyein, H. Y. Y. (2023) · Sensors & Diagnostics · doi:10.1039/d3sd00165b · Cited by 15
Fasseaux, H., Caucheteur, C., & Loyez, M. (2024) · Laser & Photonics Review · doi:10.1002/lpor.202400833 · Cited by 15
Metamaterial-enabled microwave sensor for non-invasive continuous glucose monitoring
Patel, S., Singh, A., Mitra, D., & Koley, C. (2025) · Results in Engineering · doi:10.1016/j.rineng.2025.105782 · Cited by 15
Hussain, S., & Park, S. (2022) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2022.133096 · Cited by 14
Emerging nanomaterials to enhance electrochemical impedance spectroscopy for biomedical applications
Chen, J., Arianpour, B., Wang, K., Wang, S., Yin, J., Zhang, Y., Zhu, E., & Hsiai, T. K. (2023) · Frontiers in Materials · doi:10.3389/fmats.2023.1146045 · Cited by 14
Self-citationWearable Ultrasound Devices for Biomedical Applications
Wang, M., Jia, L., Li, H., & Feng, X. (2025) · FlexTech · doi:10.1002/fle2.70001 · Cited by 13
Kothari, A., Jagannath, B., Muthukumar, S., & Prasad, S. (2022) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2022.100122 · Cited by 13
Kumar, K., Singh, K. R., Rathour, R. S., Singh, J., Bhattacharya, S., & Pandey, S. S. (2024) · Langmuir · doi:10.1021/acs.langmuir.4c02457 · Cited by 12
Cheng, C., Ganguly, S., Li, P., & Tang, X. S. (2024) · Biosensors · doi:10.3390/bios14120584 · Cited by 13
Marchianò, V., Tricase, A., Macchia, E., Bollella, P., & Torsi, L. (2024) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-024-05467-7 · Cited by 11
Advances in textile-based microfluidics for biomolecule sensing
Milić, L., Zambry, N. S., Ibrahim, F., Petrović, B., Kojić, S., Thiha, A., Joseph, K., Jamaluddin, N. F., & Stojanović, G. M. (2024) · Biomicrofluidics · doi:10.1063/5.0222244 · Cited by 11
Sweat gland morphology and physiology in diabetes, neuropathy, and nephropathy: a review
Singaram, S., Ramakrishnan, K., Selvam, J., Senthil, M., & Narayanamurthy, V. (2022) · Archives of Physiology and Biochemistry · doi:10.1080/13813455.2022.2114499 · Cited by 14
Metadata
- Authors
- Xu, J., Fang, Y., & Chen, J.
- Affiliations
- North China Electric Power University (CN)
- University of California, Los Angeles (US)
- Corresponding author
- Chen, Jun
- Venue
- Biosensors
- Publisher
- MDPI AG
- Published
- 2021-07-23
- Volume
- 11
- Issue
- 8
- Pages
- 245
- ISSN
- 2079-6374 (ISSN-L)
- PMC
- PMC8391966
- OpenAlex
- W3186719133
- Cited by
- 208
- References
- 118
- Citations by year
- 2026: 28 · 2025: 53 · 2024: 48 · 2023: 38 · 2022: 34 · 2021: 7
- FWCI
- 2.69
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Biosensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- eScholarship (California Digital Library) (submittedVersion)
- eScholarship (California Digital Library) (submittedVersion, cc-by)
- Funders
- Israel Science Foundation
- University of California, Los Angeles
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- wearable biosensors, sweat analysis, non-invasive diagnosis, wearable bioelectronics, flexible sensors, sweating, point-of-care testing, real-time health monitoring, electrochemical sensing, microfluidics
- MeSH terms
- Wearable Electronic Devices, Sweat, Biosensing Techniques, Microfluidics, Electrochemical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review