Wearable Biosensors for Non-Invasive Sweat Diagnostics
Open accessAbstract
Recent advances in microfluidics, microelectronics, and electrochemical sensing methods have steered the way for the development of novel and potential wearable biosensors for healthcare monitoring. Wearable bioelectronics has received tremendous attention worldwide due to its great a potential for predictive medical modeling and allowing for personalized point-of-care-testing (POCT). They possess many appealing characteristics, for example, lightweight, flexibility, good stretchability, conformability, and low cost. These characteristics make wearable bioelectronics a promising platform for personalized devices. In this paper, we review recent progress in flexible and wearable sensors for non-invasive biomonitoring using sweat as the bio-fluid. Real-time and molecular-level monitoring of personal health states can be achieved with sweat-based or perspiration-based wearable biosensors. The suitability of sweat and its potential in healthcare monitoring, sweat extraction, and the challenges encountered in sweat-based analysis are summarized. The paper also discusses challenges that still hinder the full-fledged development of sweat-based wearables and presents the areas of future research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures
![Figure 1 Wearable and flexible sensors for continuous biofluids analysis. (a) Soft PDMS contact lens with a glucose-sensing strip attached. Reproduced with permission from ref. [75], Copyright from 2020, Elsevier B.V. (b) All-printed tattoo-based ISF glucose sensor. Reproduced with permission from ref. [49], Copyright 2015, American Chemical Society. (c) Dynamic nanoparticle-based breath sensor. Reproduced with permission from ref. [78], Copyright from 2015, American Chemical Society. (d) Bacteria sensing on tooth enamel with graphene-based nanosensors. Reproduced with permission from ref. [79], Copyright from 2012, Nature Publishing Group. (e) Smart bandage for chemical sensing of wound pH using pH-sensitive threads. CMOS wireless readout and 2D mapping of pH levels were incorporated Reproduced with permission from ref. [74], Copyright 2017 IEEE. (f) Diabetes patch is composed of sweat-control (i, ii), sensing (iii–vii) and therapy (viii–x) components. (g) Integrated wearable diabetes monitoring and therapy system. (h) The electrochemical device on the human skin with perspiration. Reproduced with permission from ref. [80], Copyright from 2016, Nature Publishing Group.](/paper-figures/8f85337129d74a14a9992324a37bef7f/wearable-biosensors-for-non-invasive-sweat-diagnostics-figure-1.jpg)
![Figure 2 Sweat gland structure and biomarker partitioning. (a) Illustration of the sweat production process and metabolites that passed along with sweat. (b) Depiction of Iontophoresis to stimulate local sweat secretion at a selected site. (c) Reverse iontophoresis drives interstitial fluid through the epidermis to the skin surface. Reproduced with permission from ref. [69], Copyright from 2018, Nature Publishing Group.](/paper-figures/97fc16914cfc480ea5b6ef3a5301258a/wearable-biosensors-for-non-invasive-sweat-diagnostics-figure-2.jpg)
![Figure 3 Sweat-based sensors for continuous health monitoring. (a) Describes the working of the device and shows the developed FTENG to power device. (b) Schematic of the sensor array. (c) Schematic of microfluidic sensor patch. (d,e) Open-circuit potential responses of the pH sensor in standard Mcllvaine’s buffer solutions (d) and a sodium ion sensor in NaCl solutions (e). Reproduced with permission from ref. [107], Copyright from 2020, the American Association for the Advancement of Science.](/paper-figures/19fe8845cca346489e8b3c6d51e09e27/wearable-biosensors-for-non-invasive-sweat-diagnostics-figure-3.jpg)
![Figure 4 Overview of the developed CF monitoring device. (a) Electrodes used for iontophoresis and sensing. (b) Flexible wearable device on user’s wrist. (c,d) Description of the working modes of system (c) mode 1: Iontophoresis (d) mode 2: Sensing. (e) Block-level diagram of the developed system. (f) Real-time on-body measurement of sweat sodium ion and chloride ion levels of a CF patient after iontophoresis-based sweat stimulation. (g) Comparison of sweat electrolyte levels between six healthy subjects and three CF patients. Reproduced with permission from ref. [93], Copyright 2017, National Academy of Sciences USA.](/paper-figures/d99b5c3cf6f34b8fa31dc53f7065c5fb/wearable-biosensors-for-non-invasive-sweat-diagnostics-figure-4.jpg)
![Figure 5 Sweat-based sensors for exercise monitoring. (a) Subject wearing forehead and wrist sensors undergoing stationary exercise. (b) Flexible integrated sensor array shown on a subject’s wrist as part of a wireless FPCB. (c) Schematic of the sensor array. (d) System-level block diagram illustrating the flow of information. (e) Real-time sweat analysis results of the FISA worn on a subject’s forehead. (f) Constant-load exercise at 150 W: power output, heart rate (in beats per minute, b.p.m.), oxygen consumption and pulmonary minute ventilation, as measured by external monitoring systems. Reproduced with permission from ref. [44], Copyright from 2016, Nature Publishing Group.](/paper-figures/34c53b39f9004bafb6e7551844505bd2/wearable-biosensors-for-non-invasive-sweat-diagnostics-figure-5.jpg)
![Figure 6 Sweat-based multimodal sensor patch for exercise monitoring. (a) Step-by-step process of fabrication and complete sensor patch prototype. (b) Fabrication of specialized sensing threads. (c–f) Measurement results of different biomarkers. Reproduced with permission from ref. [116], Copyright from 2020, Nature Publishing Group.](/paper-figures/d4efaf3d44aa4cc78813ce34baa2877c/wearable-biosensors-for-non-invasive-sweat-diagnostics-figure-6.jpg)
![Figure 7 Drug sensing mechanism and ethanol levels measurement. (a) Interaction of the sensor with sweat. (b) Cycling and sweat analysis. Examples of sweat levodopa concentrations for three different subjects after they consume 450 g of fava beans. (c) Averaged time of peak levodopa concentration for three different subjects across multiple exercise trials. (d) Optical image of the S-band worn on a subject’s wrist. Reproduced with permission from ref. [99], Copyright from 2019, American Chemical Society. (e) Sweat ethanol sensor used to send alerts to a smart device. (f) Schematic diagram of constituents in the iontophoretic system (left) and of the reagent layer and processes involved in the amperometric sensing of ethanol on the working electrode (right). (g–i) Experiments with consumption of 12 oz of beer measured from three different human subjects before (plot “a”) and after drinking alcohol beverage (plot “b”). (j) Chronoamperograms obtained from a: BAC 0%, b: BAC 0.025% and c: BAC 0.062%. (k) Correlation between current response and the BAC level. Reproduced with permission from ref. [101], Copyright from 2016, American Chemical Society.](/paper-figures/34b91b94ee394b7dba7491b1f2b75267/wearable-biosensors-for-non-invasive-sweat-diagnostics-figure-7.jpg)
![Figure 8 Sweat-based sensors for biomolecules monitoring. (a) Schematic showing a stretchable chemical immunosensor for TNF-α cytokine sensing. (b) Schematic illustration of the TNF-α cytokine proteins immobilized on the working electrode for electrochemical sensing. (c) Image of fabricated device arrays. Reproduced with permission from ref. [103], Copyright from 2019, Elsevier. (d) Schematic illustration of cortisol in sweat and saliva. CRH, corticotropin-releasing hormone; ACTH, adrenocorticotropic hormone. (e) Schematic showing the light and dark cycle for regulating circadian rhythm and controlling of cortisol transport to sweat. (f) Cortisol levels in serum, saliva, and sweat at different times from a healthy subject. Reproduced with permission from ref. [27], Copyright from 2020, Elsevier.](/paper-figures/93a890647b17476aa335ffc2c1d58043/wearable-biosensors-for-non-invasive-sweat-diagnostics-figure-8.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The same temporal change of cortisol concentration was also reported for all biofluids, such as saliva, serum, and sweat.[ 8 , 30 ]”
From MicroSweat: A wearable microfluidic patch for noninvasive and reliable sweat collection enables human stress monitoring (2023) · cites this paper as [30]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087 · cited 7×
“For example, diabetes is directly related to the metabolite profile of glucose, which can be easily detected through sweat [44,98].”
BackgroundMethodInfluentialLee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315 · cited 5×
“Moreover, because the concentration of chlorine in the sweat of patients who have cystic fibrosis (CF) is abnormally high, the analysis of chlorine in sweat has been regarded as a widely used method for the diagnosis of CF [74].”
BackgroundMethodInfluentialA soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
A laser-engraved wearable sensor for sensitive detection of uric acid and tyrosine in sweat
Yang, Y., Song, Y., Bo, X., Min, J., Pak, O. S., Zhu, L., Wang, M., Tu, J., Kogan, A., Zhang, H., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-019-0321-x · Cited by 1,270
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Lee, H., Song, C., Hong, Y. S., Kim, M., Cho, H. R., Kang, T., Shin, K., Choi, S. H., Hyeon, T., & Kim, D.-H. (2017) · Science Advances · doi:10.1126/sciadv.1601314 · Cited by 1,118
Self-powered ultra-flexible electronics via nano-grating-patterned organic photovoltaics
Park, S., Heo, S. W., Lee, W., Inoue, D., Jiang, Z., Yu, K., Jinno, H., Hashizume, D., Sekino, M., Yokota, T., et al. (2018) · Nature · doi:10.1038/s41586-018-0536-x · Cited by 1,068
Graphene-based wireless bacteria detection on tooth enamel
Mannoor, M. S., Tao, H., Clayton, J. D., Sengupta, A., Kaplan, D. L., Naik, R. R., Verma, N., Omenetto, F. G., & McAlpine, M. C. (2012) · Nature Communications · doi:10.1038/ncomms1767 · Cited by 1,014
Smart Textiles for Electricity Generation
Chen, G., Li, Y., Bick, M., & Chen, J. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00821 · Cited by 938
Self-citationSign-to-speech translation using machine-learning-assisted stretchable sensor arrays
Zhou, Z., Chen, K. J., Li, X., Zhang, S., Wu, Y., Zhou, Y., Meng, K., Sun, C., He, Q., Fan, W., et al. (2020) · Nature Electronics · doi:10.1038/s41928-020-0428-6 · Cited by 863
Self-citationElectrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Emaminejad, S., Gao, W., Wu, E., Davies, Z. A., Yin Yin Nyein, H., Challa, S., Ryan, S. P., Fahad, H. M., Chen, K., Shahpar, Z., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701740114 · Cited by 839
Unobtrusive Sensing and Wearable Devices for Health Informatics
Zheng, Y.-L., Ding, X., Poon, C. C. Y., Lo, B. P. L., Zhang, H., Zhou, X.-L., Yang, G., Zhao, N., & Zhang, Y. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2309951 · Cited by 725
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724
Wearable Electrochemical Sensors and Biosensors: A Review
Windmiller, J. R., & Wang, J. (2012) · Electroanalysis · doi:10.1002/elan.201200349 · Cited by 717
Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
Bandodkar, A. J., Jia, W., Yardımcı, C., Wang, X., Ramirez, J., & Wang, J. (2015) · Analytical Chemistry · doi:10.1021/ac504300n · Cited by 700
Wearable salivary uric acid mouthguard biosensor with integrated wireless electronics
Kim, J., Imani, S., de Araujo, W. R., Warchall, J., Valdés-Ramírez, G., Paixão, T. R. L. C., Mercier, P. P., & Wang, J. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.039 · Cited by 678
A Wearable Electrochemical Platform for Noninvasive Simultaneous Monitoring of Ca2+ and pH
Nyein, H. Y. Y., Gao, W., Shahpar, Z., Emaminejad, S., Challa, S., Chen, K., Fahad, H. M., Tai, L.-C., Ota, H., Davis, R. W., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b04005 · Cited by 669
Yu, Y., Nassar, J., Xu, C., Min, J., Yang, Y., Dai, A., Doshi, R., Huang, A., Song, Y., Gehlhar, R., et al. (2020) · Science Robotics · doi:10.1126/scirobotics.aaz7946 · Cited by 655
Wireless battery-free wearable sweat sensor powered by human motion
Song, Y., Min, J., Yu, Y., Wang, H., Yang, Y., Zhang, H., & Gao, W. (2020) · Science Advances · doi:10.1126/sciadv.aay9842 · Cited by 652
Noninvasive Alcohol Monitoring Using a Wearable Tattoo-Based Iontophoretic-Biosensing System
Kim, J., Jeerapan, I., Imani, S., Cho, T. N., Bandodkar, A., Cinti, S., Mercier, P. P., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00356 · Cited by 599
Integrated textile sensor patch for real-time and multiplex sweat analysis
He, W., Wang, C., Wang, H., Jian, M., Lu, W., Liang, X., Zhang, X., Yang, F., & Zhang, Y. (2019) · Science Advances · doi:10.1126/sciadv.aax0649 · Cited by 564
Wearable sensors for monitoring the physiological and biochemical profile of the athlete
Seshadri, D. R., Li, R. T., Voos, J. E., Rowbottom, J. R., Alfes, C. M., Zorman, C. A., & Drummond, C. K. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0150-9 · Cited by 537
Wearable and Implantable Triboelectric Nanogenerators
Liu, Z., Li, H., Shi, B., Fan, Y., Wang, Z. L., & Li, Z. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808820 · Cited by 517
A contact lens with embedded sensor for monitoring tear glucose level
Yao, H., Shum, A. J., Cowan, M., Lähdesmäki, I., & Parviz, B. A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.12.042 · Cited by 513
Investigation of Cortisol Dynamics in Human Sweat Using a Graphene-Based Wireless mHealth System
Torrente-Rodríguez, R. M., Tu, J., Yang, Y., Min, J., Wang, M., Song, Y., Yu, Y., Xu, C., Ye, C., IsHak, W. W., et al. (2020) · Matter · doi:10.1016/j.matt.2020.01.021 · Cited by 479
Preservation and Storage Stability of Extracellular Vesicles for Therapeutic Applications
Jeyaram, A., & Jay, S. M. (2017) · The AAPS Journal · doi:10.1208/s12248-017-0160-y · Cited by 461
A Wireless Textile Based Sensor System for Self-Powered Personalized Health Care
Meng, K., Zhao, S., Zhou, Y., Wu, Y., Zhang, S., He, Q., Wang, X., Zhou, Z., Fan, W., Tan, X., et al. (2019) · Matter · doi:10.1016/j.matt.2019.12.025 · Cited by 453
Self-citationA wearable multisensing patch for continuous sweat monitoring
Anastasova, S., Crewther, B., Bembnowicz, P., Curto, V., Ip, H. M., Rosa, B., & Yang, G.-Z. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.038 · Cited by 443
Nanogenerators for smart cities in the era of 5G and Internet of Things
Zhao, X., Askari, H., & Chen, J. (2021) · Joule · doi:10.1016/j.joule.2021.03.013 · Cited by 440
Self-citationVariations in Regional Sweat Composition in Normal Human Males
Patterson, M. J., Galloway, S. D. R., & Nimmo, M. A. (2000) · Experimental Physiology · doi:10.1111/j.1469-445x.2000.02058.x · Cited by 438
Skin-interfaced systems for sweat collection and analytics
Choi, J., Ghaffari, R., Baker, L. B., & Rogers, J. A. (2018) · Science Advances · doi:10.1126/sciadv.aar3921 · Cited by 433
Li, X., Dunn, J., Salins, D., Zhou, G., Zhou, W., Schüssler-Fiorenza Rose, S. M., Perelman, D., Colbert, E., Runge, R., Rego, S., et al. (2017) · PLOS Biology · doi:10.1371/journal.pbio.2001402 · Cited by 431
Smart textiles for personalized thermoregulation
Fang, Y., Chen, G., Bick, M., & Chen, J. (2021) · Chemical Society Reviews · doi:10.1039/d1cs00003a · Cited by 425
Self-citationBandodkar, A. J., You, J., Kim, N.-H., Gu, Y. Q., Kumar, R., Mohan, A. M. V., Kurniawan, J. F., Imani, S., Nakagawa, T., Parish, B., et al. (2017) · Energy & Environmental Science · doi:10.1039/c7ee00865a · Cited by 420
Adhesive RFID Sensor Patch for Monitoring of Sweat Electrolytes
Rose, D. P., Ratterman, M. E., Griffin, D. K., Hou, L., Kelley-Loughnane, N., Naik, R. R., Hagen, J. A., Papautsky, I., & Heikenfeld, J. C. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2369991 · Cited by 416
Wearable Microsensor Array for Multiplexed Heavy Metal Monitoring of Body Fluids
Gao, W. F., Nyein, H. Y. Y., Shahpar, Z., Fahad, H. M., Chen, K., Emaminejad, S., Gao, Y., Tai, L., Ota, H., Wu, E. G., et al. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00287 · Cited by 393
Muscle Fibers Inspired High‐Performance Piezoelectric Textiles for Wearable Physiological Monitoring
Su, Y., Chen, C., Pan, H. L., Yang, Y., Chen, G., Zhao, X., Li, W., Gong, Q., Xie, G., Zhou, Y., et al. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202010962 · Cited by 388
Self-citationWearable Sensors for Biochemical Sweat Analysis
Bandodkar, A. J., Jeang, W. J., Ghaffari, R., & Rogers, J. A. (2019) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061318-114910 · Cited by 387
Wearable flexible sweat sensors for healthcare monitoring: a review
Chung, M., Fortunato, G., & Radacsi, N. (2019) · Journal of The Royal Society Interface · doi:10.1098/rsif.2019.0217 · Cited by 378
A 3-$\mu\hbox{W}$ CMOS Glucose Sensor for Wireless Contact-Lens Tear Glucose Monitoring
Liao, Y.-T., Yao, H., Lingley, A., Parviz, B., & Otis, B. P. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2170633 · Cited by 372
Wearable triboelectric nanogenerators for biomechanical energy harvesting
Zou, Y., Raveendran, V., & Chen, J. (2020) · Nano Energy · doi:10.1016/j.nanoen.2020.105303 · Cited by 358
Self-citationPotentiometric sensors for trace-level analysis
Bakker, E., & Pretsch, E. (2005) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2005.01.003 · Cited by 355
Su, Y., Wang, J., Wang, B., Yang, T., Yang, B., Xie, G., Zhou, Y., Zhang, S., Tai, H., Cai, Z., et al. (2020) · ACS Nano · doi:10.1021/acsnano.0c01804 · Cited by 351
Self-citationAbellán-Llobregat, A., Jeerapan, I., Bandodkar, A., Vidal, L., Canals, A., Wang, J., & Morallón, E. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.01.058 · Cited by 348
A potentiometric tattoo sensor for monitoring ammonium in sweat
Guinovart, T., Bandodkar, A. J., Windmiller, J. R., Andrade, F. J., & Wang, J. (2013) · The Analyst · doi:10.1039/c3an01672b · Cited by 343
Manipulating Relative Permittivity for High-Performance Wearable Triboelectric Nanogenerators
Jin, L., Xiao, X., Deng, W., Nashalian, A., He, D., Raveendran, V., Yan, C., Su, H. F., Chu, X., Yang, T., et al. (2020) · Nano Letters · doi:10.1021/acs.nanolett.0c01987 · Cited by 319
Self-citationChoi, J., Kang, D., Han, S., Kim, S. B., & Rogers, J. A. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201601355 · Cited by 318
Zhou, Z., Padgett, S., Cai, Z., Conta, G., Wu, Y., He, Q., Zhang, S., Sun, C., Liu, J., Fan, E., et al. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112064 · Cited by 318
Self-citationMethylxanthine Drug Monitoring with Wearable Sweat Sensors
Tai, L., Gao, W., Chao, M., Bariya, M., Ngo, Q. P., Shahpar, Z., Nyein, H. Y. Y., Park, H., Sun, J., Jung, Y., et al. (2018) · Advanced Materials · doi:10.1002/adma.201707442 · Cited by 310
Testing for drugs of abuse in saliva and sweat
Kidwell, D. A., Holland, J. C., & Athanaselis, S. (1998) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(97)00572-0 · Cited by 300
Existing and Emerging Technologies for Point-of-Care Testing.
John, A. S., & Price, C. P. (2014) · PubMed · Cited by 294
Non‐invasive Analyte Access and Sensing through Eccrine Sweat: Challenges and Outlook circa 2016
Heikenfeld, J. (2016) · Electroanalysis · doi:10.1002/elan.201600018 · Cited by 294
A Fully Integrated and Self-Powered Smartwatch for Continuous Sweat Glucose Monitoring
Zhao, J., Lin, Y., Wu, J., Nyein, H. Y. Y., Bariya, M., Tai, L., Chao, M., Ji, W., Zhang, G. B., Fan, Z., et al. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00891 · Cited by 289
Leveraging triboelectric nanogenerators for bioengineering
Zhang, S., Bick, M., Xiao, X., Chen, G., Nashalian, A., & Chen, J. (2021) · Matter · doi:10.1016/j.matt.2021.01.006 · Cited by 289
Self-citationA wearable electrochemical sensor for the real-time measurement of sweat sodium concentration
Schazmann, B., Morris, D., Slater, C., Beirne, S., Fay, C., Reuveny, R., Moyna, N., & Diamond, D. (2010) · Analytical Methods · doi:10.1039/b9ay00184k · Cited by 286
Universal mobile electrochemical detector designed for use in resource-limited applications
Nemiroski, A., Christodouleas, D. C., Hennek, J. W., Kumar, A. A., Maxwell, E. J., Fernández-Abedul, M. T., & Whitesides, G. M. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1405679111 · Cited by 285
Stretchable, Wireless Sensors and Functional Substrates for Epidermal Characterization of Sweat
Huang, X. L., Liu, Y., Chen, K., Shin, W., Lu, C., Kong, G., Patnaik, D., Lee, S., Cortes, J. F., & Rogers, J. A. (2014) · Small · doi:10.1002/smll.201400483 · Cited by 282
Chu, M. X., Miyajima, K., Takahashi, D., Arakawa, T., Sano, K., Sawada, S.-I., Kudo, H., Iwasaki, Y., Akiyoshi, K., Mochizuki, M., et al. (2011) · Talanta · doi:10.1016/j.talanta.2010.10.055 · Cited by 279
Textile‐Based Triboelectric Nanogenerators for Self‐Powered Wearable Electronics
Kwak, S. S., Yoon, H., & Kim, S. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201804533 · Cited by 270
Engineering Materials at the Nanoscale for Triboelectric Nanogenerators
Zhou, Y., Deng, W., Xu, J. H., & Chen, J. (2020) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2020.100142 · Cited by 270
Self-citationRecent Developments, Characteristics, and Potential Applications of Electrochemical Biosensors
Mehrvar, M., & Abdi, M. (2004) · Analytical Sciences · doi:10.2116/analsci.20.1113 · Cited by 266
Photo-Rechargeable Fabrics as Sustainable and Robust Power Sources for Wearable Bioelectronics
Zhang, N., Huang, F., Zhao, S., Lv, X., Zhou, Y., Xiang, S., Xu, S., Li, Y., Chen, G., Tao, C., et al. (2020) · Matter · doi:10.1016/j.matt.2020.01.022 · Cited by 260
Self-citationA flexible and wearable glucose sensor based on functional polymers with Soft-MEMS techniques
Kudo, H., Sawada, T., Kazawa, E., Yoshida, H., Iwasaki, Y., & Mitsubayashi, K. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.05.006 · Cited by 255
Su, Y., Yang, T., Zhao, X., Cai, Z., Chen, G., Yao, M., Chen, K. J., Bick, M., Wang, J., Li, S., et al. (2020) · Nano Energy · doi:10.1016/j.nanoen.2020.104941 · Cited by 248
Self-citationAdvances in triboelectric nanogenerators for biomedical sensing
Tat, T., Libanori, A., Au, C., Yau, A., & Chen, J. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112714 · Cited by 247
Self-citationWearable temporary tattoo sensor for real-time trace metal monitoring in human sweat
Kim, J., de Araujo, W. R., Samek, I. A., Bandodkar, A. J., Jia, W., Brunetti, B., Paixão, T. R. L. C., & Wang, J. (2015) · Electrochemistry Communications · doi:10.1016/j.elecom.2014.11.024 · Cited by 245
Chen, X., Song, Y., Su, Z., Chen, H., Cheng, X., Zhang, J., Han, M., & Zhang, H. (2017) · Nano Energy · doi:10.1016/j.nanoen.2017.05.047 · Cited by 244
Bio-sensing textile based patch with integrated optical detection system for sweat monitoring
Morris, D., Coyle, S. M., Wu, Y., Lau, K. T., Wallace, G. G., & Diamond, D. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.02.032 · Cited by 234
3D-Printed Ultra-Robust Surface-Doped Porous Silicone Sensors for Wearable Biomonitoring
Davoodi, E., Montazerian, H., Haghniaz, R., Rashidi, A., Ahadian, S., Sheikhi, A., Chen, J., Khademhosseini, A., Milani, A. S., Hoorfar, M., et al. (2020) · ACS Nano · doi:10.1021/acsnano.9b06283 · Cited by 234
Self-citationPortable biosensor for monitoring cortisol in low-volume perspired human sweat
Kinnamon, D., Ghanta, R., Lin, K.-C., Muthukumar, S., & Prasad, S. (2017) · Scientific Reports · doi:10.1038/s41598-017-13684-7 · Cited by 231
Dynamic Nanoparticle-Based Flexible Sensors: Diagnosis of Ovarian Carcinoma from Exhaled Breath
Kahn, N. F., Lavie, O., Paz, M., Segev, Y., & Haick, H. (2015) · Nano Letters · doi:10.1021/acs.nanolett.5b03052 · Cited by 230
Advances in Nanostructures for High‐Performance Triboelectric Nanogenerators
Zou, Y., Xu, J. H., Chen, K. J., & Chen, J. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202000916 · Cited by 224
Self-citationCorrie, S. R., Coffey, J. W., Islam, J., Markey, K. A., & Kendall, M. A. F. (2015) · The Analyst · doi:10.1039/c5an00464k · Cited by 220
Highly fluorescent copper nanoclusters for sensing and bioimaging
An, Y., Ren, Y., Bick, M., Dudek, A., Waworuntu, E. H.-W., Tang, J., Chen, J., & Chang, B. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112078 · Cited by 218
Self-citationCizza, G., Marques, A. H., Eskandari, F., Christie, I. C., Torvik, S., Silverman, M. N., Phillips, T. M., & Sternberg, E. M. (2008) · Biological Psychiatry · doi:10.1016/j.biopsych.2008.05.035 · Cited by 208
Achievements and Challenges for Real-Time Sensing of Analytes in Sweat within Wearable Platforms
Brothers, M. C., DeBrosse, M., Grigsby, C. C., Naik, R. R., Hussain, S. M., Heikenfeld, J., & Kim, S. S. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.8b00555 · Cited by 207
Triboelectric Nanogenerators for Therapeutic Electrical Stimulation
Conta, G., Libanori, A., Tat, T., Chen, G., & Chen, J. (2021) · Advanced Materials · doi:10.1002/adma.202007502 · Cited by 205
Self-citationWearable Sweat Band for Noninvasive Levodopa Monitoring
Tai, L.-C., Liaw, T. S., Lin, Y., Nyein, H. Y. Y., Bariya, M., Ji, W., Hettick, M., Zhao, C., Zhao, J., Hou, L., et al. (2019) · Nano Letters · doi:10.1021/acs.nanolett.9b02478 · Cited by 177
Textile Triboelectric Nanogenerators for Wearable Pulse Wave Monitoring
Chen, G., Au, C., & Chen, J. (2021) · Trends in biotechnology · doi:10.1016/j.tibtech.2020.12.011 · Cited by 173
Self-citationThread-based multiplexed sensor patch for real-time sweat monitoring
Terse-Thakoor, T., Punjiya, M., Matharu, Z., Lyu, B., Ahmad, M., Giles, G. E., Owyeung, R. E., Alaimo, F., Baghini, M. S., Brunyé, T. T., et al. (2020) · npj Flexible Electronics · doi:10.1038/s41528-020-00081-w · Cited by 172
Electrochemical sensing based on printable temporary transfer tattoos
Windmiller, J. R., Bandodkar, A. J., Valdés‐Ramírez, G., Parkhomovsky, S., Martinez, A. G., & Wang, J. (2012) · Chemical Communications · doi:10.1039/c2cc32839a · Cited by 169
The Current Status of Sweat Testing For Drugs of Abuse: A Review
Giovanni, N. D., & Fucci, N. (2013) · Current Medicinal Chemistry · doi:10.2174/0929867311320040006 · Cited by 164
Smart Insole for Robust Wearable Biomechanical Energy Harvesting in Harsh Environments
Zhou, Z., Weng, L., Tat, T., Libanori, A., Lin, Z., Ge, L., Yang, J., & Chen, J. (2020) · ACS Nano · doi:10.1021/acsnano.0c06949 · Cited by 158
Self-citation初, 明. (2011) · Medical Entomology and Zoology · Cited by 157
Wearable Triboelectric Nanogenerators for Therapeutics
Xiao, X., Chen, G., Libanori, A., & Chen, J. (2021) · Trends in Chemistry · doi:10.1016/j.trechm.2021.01.001 · Cited by 152
Self-citationHigh-efficiency self-charging smart bracelet for portable electronics
Song, Y., Wang, H., Cheng, X., Li, G., Chen, X., Chen, H., Miao, L., Zhang, X., & Zhang, H. (2018) · Nano Energy · doi:10.1016/j.nanoen.2018.10.045 · Cited by 140
Flexible nanoporous tunable electrical double layer biosensors for sweat diagnostics
Munje, R. D., Muthukumar, S., Panneer Selvam, A., & Prasad, S. (2015) · Scientific Reports · doi:10.1038/srep14586 · Cited by 138
Wearable triboelectric nanogenerators for heart rate monitoring
Shen, S., Xiao, X., Xiao, X., & Chen, J. (2021) · Chemical Communications · doi:10.1039/d1cc02091a · Cited by 135
Self-citationA portable triboelectric spirometer for wireless pulmonary function monitoring
Xu, Q., Fang, Y., Jing, Q., Hu, N., Lin, K., Pan, Y., Xu, L., Gao, H., Yuan, M., Chu, L., et al. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113329 · Cited by 133
Self-citationTriboelectric Nanogenerators for Self‐Powered Wound Healing
Xiao, X., Xiao, X., Nashalian, A., Libanori, A., Fang, Y., Li, X., & Chen, J. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100975 · Cited by 127
Self-citationTernary Electrification Layered Architecture for High-Performance Triboelectric Nanogenerators
Deng, W., Zhou, Y., Zhao, X., Zhang, S., Zou, Y., Xu, J., Yeh, M.-H., Guo, H., & Chen, J. (2020) · ACS Nano · doi:10.1021/acsnano.0c04113 · Cited by 125
Self-citationTriboelectric Nanogenerator Enabled Smart Shoes for Wearable Electricity Generation
Zou, Y., Libanori, A., Xu, J. H., Nashalian, A., & Chen, J. (2020) · Research · doi:10.34133/2020/7158953 · Cited by 123
Self-citationElectrochemical Diagnostics for Bacterial Infectious Diseases
Karbelkar, A. A., & Furst, A. L. (2020) · ACS Infectious Diseases · doi:10.1021/acsinfecdis.0c00342 · Cited by 123
Sweat as a Source of Next-Generation Digital Biomarkers
Brasier, N., & Eckstein, J. (2019) · Digital Biomarkers · doi:10.1159/000504387 · Cited by 120
Technological leap for sweat sensing
Heikenfeld, J. C. (2016) · Nature · doi:10.1038/529475a · Cited by 117
Peng, Z., Song, J. Y., Gao, Y., Liu, J., Lee, C. H., Chen, G., Wang, Z., Chen, J., & Leung, M. K. H. (2021) · Nano Energy · doi:10.1016/j.nanoen.2021.106021 · Cited by 106
Self-citationTextiles for learning tactile interactions
Chen, G., Fang, Y., Zhao, X., Tat, T., & Chen, J. (2021) · Nature Electronics · doi:10.1038/s41928-021-00560-6 · Cited by 99
Self-citationSonner, Z., Wilder, E., Gaillard, T. R., Kasting, G. B., & Heikenfeld, J. C. (2017) · Lab on a Chip · doi:10.1039/c7lc00364a · Cited by 91
Textile triboelectric nanogenerators for self-powered biomonitoring
Lama, J. E., Yau, A., Chen, G., Sivakumar, A., Zhao, X., & Chen, J. (2021) · Journal of Materials Chemistry A · doi:10.1039/d1ta02518j · Cited by 90
Self-citationAn ultrathin robust polymer membrane for wearable solid-state electrochemical energy storage
Chu, X., Zhao, X., Zhou, Y., Wang, Y., Han, X., Zhou, Y., Ma, J., Wang, Z., Huang, H., Xu, Z., et al. (2020) · Nano Energy · doi:10.1016/j.nanoen.2020.105179 · Cited by 90
Self-citationLeverage Surface Chemistry for High-Performance Triboelectric Nanogenerators
Xu, J. H., Zou, Y., Nashalian, A., & Chen, J. (2020) · Frontiers in Chemistry · doi:10.3389/fchem.2020.577327 · Cited by 88
Self-citation3D‐Printed Triboelectric Nanogenerators: State of the Art, Applications, and Challenges
Mahmud, M. A. P., Zolfagharian, A., Gharaie, S., Kaynak, A., Farjana, S. H., Ellis, A. V., Chen, J., & Kouzani, A. Z. (2021) · Advanced Energy and Sustainability Research · doi:10.1002/aesr.202000045 · Cited by 75
Self-citationTriboelectric nanogenerators for self-powered drug delivery
Li, X., Tat, T., & Chen, J. (2021) · Trends in Chemistry · doi:10.1016/j.trechm.2021.04.009 · Cited by 68
Self-citationSolution-Processed Submicron Free-Standing, Conformal, Transparent, Breathable Epidermal Electrodes
Fang, Y., Li, Y., Li, Y., Ding, M., Xie, J., & Hu, B. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c04134 · Cited by 62
Self-citationYoshizumi, J., Kumamoto, S., Nakamura, M., & Yamana, K. (2008) · The Analyst · doi:10.1039/b719089c · Cited by 61
All-in-one conformal epidermal patch for multimodal biosensing
Fang, Y., Zhao, X., Tat, T., Xiao, X., Chen, G., Xu, J. H., & Chen, J. (2021) · Matter · doi:10.1016/j.matt.2021.03.005 · Cited by 58
Self-citationCryo‐Transferred Ultrathin and Stretchable Epidermal Electrodes
Fang, Y., Li, Y., Wang, X., Zhou, Z., Zhang, K., Zhou, J., & Hu, B. (2020) · Small · doi:10.1002/smll.202000450 · Cited by 57
Self-citationNanoduct® sweat testing for rapid diagnosis in newborns, infants and children with cystic fibrosis
Desax, M.-C., Ammann, R. A., Hammer, J., Schoeni, M. H., & Barben, J. (2007) · European Journal of Pediatrics · doi:10.1007/s00431-007-0485-0 · Cited by 56
Kim, B., Lee, H., & Lee, N. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.12.045 · Cited by 54
Use of Silk Proteins to Form Organic, Flexible, Degradable Biosensors for Metabolite Monitoring
Xu, M., Jiang, Y., Pradhan, S., & Yadavalli, V. K. (2019) · Frontiers in Materials · doi:10.3389/fmats.2019.00331 · Cited by 50
Learning from nature for healthcare, energy, and environment
Xiao, X., Xiao, X., Lan, Y., & Chen, J. (2021) · The Innovation · doi:10.1016/j.xinn.2021.100135 · Cited by 29
Self-citationMugweru, A. M., Clark, B. L., & Pishko, M. V. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100308 · Cited by 25
Shields, J. B., Johnson, B. C., Hamilton, T. S., & Mitchell, H. H. (1945) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(17)41548-1 · Cited by 22
In Vivo Intravascular Pacing Using a Wireless Microscale Stimulator
Abiri, P., Duarte‐Vogel, S., Chou, T.-C., Abiri, A., Gudapati, V., Yousefi, A., Roustaei, M., Chang, C., Cui, Q., Hsu, J. J., et al. (2021) · Annals of Biomedical Engineering · doi:10.1007/s10439-021-02729-8 · Cited by 10
Self-citationEditorial: Emerging Micro- and Nanotechnologies for Medical and Pharmacological Applications
Xiao, Y., Chen, J., Wang, C., Ding, J., & Tao, W. (2021) · Frontiers in Pharmacology · doi:10.3389/fphar.2021.648749 · Cited by 9
Self-citation
Research works printed but not linked: 1
- Xiao, X., Xiao, X., Nashalian, A., Libanori, A., Fang, Y., Li, X., and Chen, J. (2021). Triboelectric Nanogenerators for Self-Powered Wound Healing. Adv. Healthc. Mater. · DOI
Cited by
Sorted by citations
Wearable and flexible electrochemical sensors for sweat analysis: a review
Gao, F., Liu, C., Zhang, L., Liu, T., Wang, Z., Song, Z., Cai, H., Fang, Z., Chen, J., Wang, J., et al. (2022) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00443-6 · Cited by 829
Self-citationPiezoelectric nanogenerators for personalized healthcare
Deng, W., Zhou, Y., Libanori, A., Chen, G., Yang, W., & Chen, J. (2022) · Chemical Society Reviews · doi:10.1039/d1cs00858g · Cited by 444
Self-citationVo, D.-K., & Trinh, K. T. L. (2024) · Biosensors · doi:10.3390/bios14110560 · Cited by 270
Advances in Wearable Strain Sensors Based on Electrospun Fibers
Gao, Z., Xiao, X., Carlo, A. D., Yin, J., Wang, Y., Huang, L., Tang, J., & Chen, J. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202214265 · Cited by 198
Self-citationResearch progress of electronic nose technology in exhaled breath disease analysis
Li, Y., Wei, X., Zhou, Y., Wang, J., & You, R. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00594-0 · Cited by 168
Metadata
- Authors
- Xu, J., Fang, Y., & Chen, J.
- Affiliations
- North China Electric Power University (CN)
- University of California, Los Angeles (US)
- Corresponding author
- Chen, Jun
- Venue
- Biosensors
- Publisher
- MDPI AG
- Published
- 2021-07-23
- Volume
- 11
- Issue
- 8
- Pages
- 245
- ISSN
- 2079-6374 (ISSN-L)
- PMC
- PMC8391966
- OpenAlex
- W3186719133
- Cited by
- 208
- References
- 118
- Citations by year
- 2026: 28 · 2025: 53 · 2024: 48 · 2023: 38 · 2022: 34 · 2021: 7
- FWCI
- 2.69
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Biosensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- eScholarship (California Digital Library) (submittedVersion)
- eScholarship (California Digital Library) (submittedVersion, cc-by)
- Funders
- Israel Science Foundation
- University of California, Los Angeles
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- wearable biosensors, sweat analysis, non-invasive diagnosis, wearable bioelectronics, flexible sensors, sweating, point-of-care testing, real-time health monitoring, electrochemical sensing, microfluidics
- MeSH terms
- Wearable Electronic Devices, Sweat, Biosensing Techniques, Microfluidics, Electrochemical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review