Emerging Encapsulation Technologies for Long-Term Reliability of Microfabricated Implantable Devices
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
The development of reliable long-term encapsulation technologies for implantable biomedical devices is of paramount importance for the safe and stable operation of implants in the body over a period of several decades. Conventional technologies based on titanium or ceramic packaging, however, are not suitable for encapsulating microfabricated devices due to their limited scalability, incompatibility with microfabrication processes, and difficulties with miniaturization. A variety of emerging materials have been proposed for encapsulation of microfabricated implants, including thin-film inorganic coatings of Al2O3, HfO2, SiO2, SiC, and diamond, as well as organic polymers of polyimide, parylene, liquid crystal polymer, silicone elastomer, SU-8, and cyclic olefin copolymer. While none of these materials have yet been proven to be as hermetic as conventional metal packages nor widely used in regulatory approved devices for chronic implantation, a number of studies have demonstrated promising outcomes on their long-term encapsulation performance through a multitude of fabrication and testing methodologies. The present review article aims to provide a comprehensive, up-to-date overview of the long-term encapsulation performance of these emerging materials with a specific focus on publications that have quantitatively estimated the lifetime of encapsulation technologies in aqueous environments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719 · cited 1×
“A few examples of these materials having been used for patients in clinical trials of active implantable devices include parylene for Utah probes [153,154], Argus II retinal implant [155], and polyimide for epiretinal [156] and subretinal implant [157,158], which have been tested, at most, for a few years.”
BackgroundBiodegradable, Elastic Shape-Memory Polymers for Potential Biomedical Applications
Lendlein, A., & Langer, R. (2002) · Science · doi:10.1126/science.1066102 · Cited by 2,146
Canales, A., Jia, X., Froriep, U. P., Koppes, R. A., Tringides, C. M., Selvidge, J., Lu, C., Hou, C., Wei, L., Fink, Y., et al. (2015) · Nature Biotechnology · doi:10.1038/nbt.3093 · Cited by 668
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Pfurtscheller, G., Müller, G. R., Pfurtscheller, J., Gerner, H. J., & Rupp, R. (2003) · Neuroscience Letters · doi:10.1016/s0304-3940(03)00947-9 · Cited by 548
Hassler, C., Boretius, T., & Stieglitz, T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22169 · Cited by 501
Subretinal visual implant alpha IMS - clinical trial interim report
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Chee, C. K., Cottriall, C. L., Gekeler, F., Groppe, M., Jackson, T. L., MacLaren, R. E., Koitschev, A., et al. (2015) · Vision Research · doi:10.1016/j.visres.2015.03.001 · Cited by 387
Five-year safety and performance results from the argus II retinal prosthesis system clinical trial.
da Cruz, L., Dorn, J. D., Humayun, M. S., Dagnelie, G., Handa, J., Barale, P.-O., Sahel, J.-A., Stanga, P. E., Hafezi, F., Safran, A. B., et al. (2016) · Ophthalmology · doi:10.1016/j.ophtha.2016.06.049 · Cited by 359 · cited 1×
“A few examples of these materials having been used for patients in clinical trials of active implantable devices include parylene for Utah probes [153,154], Argus II retinal implant [155], and polyimide for epiretinal [156] and subretinal implant [157,158], which have been tested, at most, for a few years.”
BackgroundBION ™ system for distributed neural prosthetic interfaces
Loeb, G. E., Peck, R. A., Moore, W. H., & Hood, K. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00011-x · Cited by 243
In vitro evaluation of the long-term stability of polyimide as a material for neural implants
Rubehn, B., & Stieglitz, T. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.053 · Cited by 242 · cited 4×
“In another study, test samples made of three different commercial polyimide products were soaked in PBS at 37, 60, and 85 ◦C, and in deionized water at 85 ◦C [86].”
BackgroundMethodInfluentialLago, N., Ceballos, D., J Rodrı́guez, F., Stieglitz, T., & Navarro, X. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.025 · Cited by 178
Winslow, B. D., Christensen, M. B., Yang, W.-K., Solzbacher, F., & Tresco, P. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.05.050 · Cited by 171
Kwon, K. Y., Sirowatka, B., Weber, A., & Li, W. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2282318 · Cited by 166
Xie, X., Rieth, L., Williams, L., Negi, S., Bhandari, R., Caldwell, R., Sharma, R., Tathireddy, P., & Solzbacher, F. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026016 · Cited by 137
Clinical applications of penetrating neural interfaces and Utah Electrode Array technologies
Normann, R. A., & Fernandez, E. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/061003 · Cited by 135
Toward a self-deploying shape memory polymer neuronal electrode
Sharp, A. A., Panchawagh, H. V., Ortega, A., Artale, R., Richardson-Burns, S., Finch, D. S., Gall, K., Mahajan, R. L., & Restrepo, D. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/l02 · Cited by 113
Long-term recording reliability of liquid crystal polymer µ ECoG arrays
Woods, V., Trumpis, M., Bent, B., Palopoli-Trojani, K., Chiang, C.-H., Wang, C., Yu, C., Insanally, M. N., Froemke, R. C., & Viventi, J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae39d · Cited by 63
Cited by
Self‐Powered Implantable Medical Devices: Photovoltaic Energy Harvesting Review
Zhao, J., Ghannam, R., Htet, K. O., Liu, Y., Law, M., Roy, V. A. L., Michel, B., Imran, M. A., & Heidari, H. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.202000779 · Cited by 218
Li, C., Cauwe, M., Yang, Y., Schaubroeck, D., Mader, L., & Op de Beeck, M. (2019) · Coatings · doi:10.3390/coatings9090579 · Cited by 46
Lamont, C., Grego, T., Nanbakhsh, K., Shah Idil, A., Giagka, V, Vanhoestenberghe, A., Cogan, S., & Donaldson, N. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abf0d6 · Cited by 28
NeuroBus - Architecture for an Ultra-Flexible Neural Interface
Sporer, M., Vasilaş, I.-G., Adžemović, A., Graber, N., Reich, S., Gueli, C., Eickenscheidt, M., Diester, I., Stieglitz, T., & Ortmanns, M. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3354785 · Cited by 13
“This conformal encapsulation of the CMOS dice is prior to transferring them to the PI substrate ensuring void free packaging of the overall encapsulation, therefore minimizing water penetration [42].”
Method
Metadata
- Authors
- Ahn, S.-H., Jeong, J., & Kim, S. J.
- Venue
- Micromachines
- Publisher
- MDPI AG
- Published
- 2019-07-31
- Volume
- 10
- Issue
- 8
- Pages
- 508
- ISSN
- 2072-666X (ISSN-L)
- OpenAlex
- W2966582236
- Cited by
- 107
- References
- 18
- FWCI
- 4.50
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.