Thin film multi-electrode softening cuffs for selective neuromodulation
Open accessAbstract
Silicone nerve cuff electrodes are commonly implanted on relatively large and accessible somatic nerves as peripheral neural interfaces. While these cuff electrodes are soft (1–50 MPa), their self-closing mechanism requires of thick walls (200–600 µm), which in turn contribute to fibrotic tissue growth around and inside the device, compromising the neural interface. We report the use of thiol-ene/acrylate shape memory polymer (SMP) for the fabrication of thin film multi-electrode softening cuffs (MSC). We fabricated multi-size MSC with eight titanium nitride (TiN) electrodes ranging from 1.35 to 13.95 × 10−4 cm 2 (1–3 kΩ) and eight smaller gold (Au) electrodes (3.3 × 10−5 cm 2; 750 kΩ), that soften at physiological conditions to a modulus of 550 MPa. While the SMP material is not as soft as silicone, the flexural forces of the SMP cuff are about 70–700 times lower in the MSC devices due to the 30 μm thick film compared to the 600 μm thick walls of the silicone cuffs. We demonstrated the efficacy of the MSC to record neural signals from rat sciatic and pelvic nerves (1000 µm and 200 µm diameter, respectively), and the selective fascicular stimulation by current steering. When implanted side-by-side and histologically compared 30 days thereafter, the MSC devices showed significantly less inflammation, indicated by a 70–80% reduction in ED1 positive macrophages, and 54–56% less fibrotic vimentin immunoreactivity. Together, the data supports the use of MSC as compliant and adaptable technology for the interfacing of somatic and autonomic peripheral nerves.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Most existing electronics based on SMPs are not very compatible with traditional 2D planar processing, which limits the development of high-precision electronics.
“By contrast, most of the existing electronics based on SMPs are not very compatible with traditional 2D planar processing, which limits the development of high-precision electronics (23, 25–28).”
From Climbing-inspired twining electrodes using shape memory for peripheral nerve stimulation and recording (2019) · cites this paper as [28]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243 · see citing works
Self-citationAjiboye, A. B., Willett, F. R., Young, D. R., Memberg, W. D., Murphy, B. A., Miller, J. P., Walter, B. L., Sweet, J. A., Hoyen, H. A., Keith, M. W., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30601-3 · Cited by 862 · see citing works
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · see citing works
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751 · see citing works
A spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415 · see citing works
Fiber composition of the rat sciatic nerve
Schmalbruch, H. (1986) · The Anatomical Record · doi:10.1002/ar.1092150111 · Cited by 402 · see citing works
Vagus nerve stimulation, side effects, and long-term safety
Ben-Menachem, E. (2001) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200109000-00005 · Cited by 400 · see citing works
In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
Weiland, J. D., Anderson, D. J., & Humayun, M. S. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805487 · Cited by 382 · see citing works
Bioelectronic medicines: a research roadmap
Birmingham, K., Gradinaru, V., Anikeeva, P., Grill, W. M., Pikov, V., McLaughlin, B., Pasricha, P., Weber, D., Ludwig, K., & Famm, K. (2014) · Nature Reviews Drug Discovery · doi:10.1038/nrd4351 · Cited by 322 · see citing works
Selective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276 · see citing works
Flexible and stretchable micro-electrodes for in vitro and in vivo neural interfaces
Lacour, S. P., Benmerah, S., Tarte, E. J., FitzGerald, J. J., Serra, J., McMahon, S. B., Fawcett, J. W., Graudejus, O., Yu, Z., & Morrison, B. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0644-8 · Cited by 265 · see citing works
Vagus nerve stimulation: Surgical technique of implantation and revision and related morbidity
Giordano, F., Zicca, A., Barba, C., Guerrini, R., & Genitori, L. (2017) · Epilepsia · doi:10.1111/epi.13678 · Cited by 258 · see citing works
Badia, J., Boretius, T., Andreu, D., Azevedo-Coste, C., Stieglitz, T., & Navarro, X. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036023 · Cited by 227 · see citing works
Cuff electrodes for chronic stimulation and recording of peripheral nerve activity
Loeb, G. E., & Peck, R. A. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00123-9 · Cited by 215 · see citing works
Principles Underlying New Methods for Chronic Neural Recording
Stein, R. B., Charles, D., DAVIS, L. A., Jhamandas, J. H., Mannard, A., & Nichols, T. R. (1975) · Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · doi:10.1017/s0317167100020333 · Cited by 211 · see citing works
Polyimide cuff electrodes for peripheral nerve stimulation
Rodri´guez, F. J., Ceballos, D., Schu¨ttler, M., Valero, A., Valderrama, E., Stieglitz, T., & Navarro, X. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00192-8 · Cited by 207 · see citing works
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., & Tyler, D. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/2/026002 · Cited by 175 · see citing works
Sensory Fibers of the Pelvic Nerve Innervating the Rat's Urinary Bladder
Shea, V. K., Cai, R., Crepps, B. A., et al. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.4.1924 · Cited by 174 · see citing works
Polasek, K. H., Hoyen, H. A., Keith, M. W., Kirsch, R. F., & Tyler, D. J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2032603 · Cited by 142 · see citing works
Ware, T., Simon, D., Hearon, K., Liu, C., Shah, S., Reeder, J., Khodaparast, N., Kilgard, M. P., Maitland, D. J., Rennaker, R. L., et al. (2012) · Macromolecular Materials and Engineering · doi:10.1002/mame.201200241 · Cited by 138 · see citing works
Self-citationImplanted Neuroprosthesis for Restoring Arm and Hand Function in People With High Level Tetraplegia
Memberg, W. D., Polasek, K. H., Hart, R. L., Bryden, A. M., Kilgore, K. L., Nemunaitis, G. A., Hoyen, H. A., Keith, M. W., & Kirsch, R. F. (2014) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2014.01.028 · Cited by 137 · see citing works
Quantification of recruitment properties of multiple contact cuff electrodes
Grill, W. M., & Mortimer, J. T. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.506402 · Cited by 136 · see citing works
Thiol‐ene/acrylate substrates for softening intracortical electrodes
Ware, T. H., Simon, D., Liu, H. C., Musa, T., Vasudevan, S., Sloan, A. M., Keefer, E. W., Rennaker, R. L., & Voit, W. E. (2013) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbmb.32946 · Cited by 126 · see citing works
Self-citationGrill, W. M., & Mortimer, J. T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.736150 · Cited by 103 · see citing works
Chronic interfacing with the autonomic nervous system using carbon nanotube (CNT) yarn electrodes
McCallum, G. A., Sui, X., Qiu, C., Marmerstein, J., Zheng, Y., Eggers, T. E., Hu, C., Dai, L., & Durand, D. M. (2017) · Scientific Reports · doi:10.1038/s41598-017-10639-w · Cited by 102 · see citing works
“Long-term stability of stimulating spiral nerve cuff electrodes on human peripheral nerves”
Christie, B. P., Freeberg, M., Memberg, W. D., Pinault, G. J. C., Hoyen, H. A., Tyler, D. J., & Triolo, R. J. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0285-3 · Cited by 97 · see citing works
Properties of the major classes of mechanoreceptors in the guinea pig bladder
Zagorodnyuk, V. P., Gibbins, I. L., Costa, M., Brookes, S. J., & Gregory, S. J. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2007.140244 · Cited by 95 · see citing works
Heo, D. N., Song, S.-J., Kim, H., Lee, Y. J., Ko, W., Lee, S. J., Lee, D., Park, S. J., Zhang, L. G., Kang, J. Y., et al. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.05.009 · Cited by 90 · see citing works
Fisher, L. E., Tyler, D. J., Anderson, J. S., & Triolo, R. J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046010 · Cited by 89 · see citing works
Flexible and highly biocompatible nanofiber-based electrodes for neural surface interfacing
Heo, D. N., Kim, H.-J., Lee, Y. J., Heo, M., Lee, S. J., Lee, D., Do, S. H., Lee, S. H., & Kwon, I. K. (2017) · ACS Nano · doi:10.1021/acsnano.6b08390 · Cited by 86 · see citing works
Multiple-electrode nerve cuffs for low-velocity and velocity-selective neural recording
Taylor, J. T., Donaldson, N., & Winter, J. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02347545 · Cited by 79 · see citing works
Delivopoulos, E., Chew, D. J., Minev, I. R., Fawcett, J. W., & Lacour, S. P. (2012) · Lab on a Chip · doi:10.1039/c2lc21277c · Cited by 68 · see citing works
A comparison of polymer substrates for photolithographic processing of flexible bioelectronics
Simon, D., Ware, T. H., Marcotte, R. J., Lund, B. R., Smith, D. W., Prima, M. A. D., Rennaker, R. L., & Voit, W. E. (2013) · Biomedical Microdevices · doi:10.1007/s10544-013-9782-8 · Cited by 56 · see citing works
Self-citationEarly interfaced neural activity from chronic amputated nerves
Garde, K. (2009) · Frontiers in Neuroengineering · doi:10.3389/neuro.16.005.2009 · Cited by 56 · see citing works
Morphology of the rat carotid sinus nerve. II. Number and size of axons
McDonald, D. M. (1983) · Journal of Neurocytology · doi:10.1007/bf01159381 · Cited by 49 · see citing works
Chronic softening spinal cord stimulation arrays
Garcia‐Sandoval, A., Pal, A., Mishra, A. M., Sherman, S., Parikh, A. R., Joshi‐Imre, A., Arreaga‐Salas, D., Gutiérrez‐Heredia, G., Duran-Martinez, A. C., Nathan, J., et al. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab90d · Cited by 49 · see citing works
Self-citationMaterial considerations for peripheral nerve interfacing
Kim, Y.-T., & Romero-Ortega, M. I. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.99 · Cited by 47 · see citing works
Self-citationBiomechanical and functional variation in rat sciatic nerve following cuff electrode implantation
Restaino, S. M., Abliz, E., Wachrathit, K., Krauthamer, V., & Shah, S. B. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-73 · Cited by 44 · see citing works
Multielectrode spiral cuff for ordered and reversed activation of nerve fibres
Rozman, J., Sovinec, B., Trlep, M., & Zorko, B. (1993) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(93)90039-2 · Cited by 41 · see citing works
Integration of High-Charge-Injection-Capacity Electrodes onto Polymer Softening Neural Interfaces
Arreaga‐Salas, D., Avendaño-Bolívar, A., Simon, D., Reit, R., Garcia‐Sandoval, A., Rennaker, R. L., & Voit, W. E. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b08139 · Cited by 41 · see citing works
Self-citationVince, V., Thil, M.-A., Gérard, A.-C., Veraart, C., Delbeke, J., & Colin, I. M. (2005) · Journal of Neuroimmunology · doi:10.1016/j.jneuroim.2004.10.010 · Cited by 35 · see citing works
Thiol‐ C lick Chemistries for Responsive Neural Interfaces
Ware, T. H., Simon, D., Hearon, K., Kang, T. H., Maitland, D. J., & Voit, W. E. (2013) · Macromolecular Bioscience · doi:10.1002/mabi.201300272 · Cited by 35 · see citing works
Self-citationCharacterization of a Thiol-Ene/Acrylate-Based Polymer for Neuroprosthetic Implants
Do, D.-H., Ecker, M., & Voit, W. (2017) · ACS Omega · doi:10.1021/acsomega.7b00834 · Cited by 35 · see citing works
Self-citationThil, M., Duy, D. T., Colin, I. M., & Delbeke, J. (2007) · Journal of Neuroimmunology · doi:10.1016/j.jneuroim.2007.01.021 · Cited by 34 · see citing works
Sterilization of Thiol-ene/Acrylate Based Shape Memory Polymers for Biomedical Applications
Ecker, M., Danda, V. R., Shoffstall, A. J., Mahmood, S. F., Joshi‐Imre, A., Frewin, C. L., Ware, T. H., Capadona, J. R., Pancrazio, J. J., & Voit, W. (2016) · Macromolecular Materials and Engineering · doi:10.1002/mame.201600331 · Cited by 31 · see citing works
Self-citationVince, V., Brelen, M. E., Delbeke, J., & Colin, I. M. (2005) · Journal of Neuroimmunology · doi:10.1016/j.jneuroim.2005.04.019 · Cited by 30 · see citing works
Cuff electrodes for very small diameter nerves — Prototyping and first recordings in vivo
Ordonez, J. S., Pikov, V., Wiggins, H., Patten, C. D., Stieglitz, T., Rickert, J., & Schüettler, M. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6945201 · Cited by 30 · see citing works
Chronic in-vivo testing of a 16-channel implantable wireless neural stimulator
Bredeson, S. D., Kanneganti, A., Deku, F., Cogan, S. F., Romero‐Ortega, M. I., & Troyk, P. R. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318537 · Cited by 27 · see citing works
Self-citationA neural blood pressure marker for bioelectronic medicines for treatment of hypertension
Sevcencu, C., Nielsen, T. N., & Struijk, J. J. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.06.031 · Cited by 24 · see citing works
Dweiri, Y. M., Stone, M. A., Tyler, D. J., McCallum, G. A., & Durand, D. M. (2016) · Journal of Visualized Experiments · doi:10.3791/54388 · Cited by 23 · see citing works
Hydrolytically Stable Thiol–ene Networks for Flexible Bioelectronics
Reit, R., Zamorano, D., Parker, S., Simon, D., Lund, B. R., Voit, W. E., & Ware, T. H. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b10593 · Cited by 20 · see citing works
Self-citationThe foreign body response and morphometric changes associated with mesh-style peripheral nerve cuffs
Christensen, M. B., & Tresco, P. A. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.11.059 · Cited by 19 · see citing works
Charge Injection Capacity of TiN Electrodes for an Extended Voltage Range
Patan, M., Shah, T., & Şahin, M. (2006) · doi:10.1109/iembs.2006.260088 · Cited by 17 · see citing works
Recovery of neural activity from nerve cuff electrodes
Wodlinger, B., & Durand, D. M. (2011) · 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2011.6091152 · Cited by 13 · see citing works
Meijs, S., Sørensen, C., Sørensen, S., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026011 · Cited by 11 · see citing works
Kim, Y., Kanneganti, A., Nothnagle, C., et al. (2015) · Bioelectronic Medicine · doi:10.15424/bioelectronmed.2015.00001 · Cited by 8 · see citing works
Self-citationKim, Y., Kanneganti, A., Fatemi, S., Nothnagle, C., Wijesundara, M. B. J., & Romero‐Ortega, M. I. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944002 · Cited by 6 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Flexible Hybrid Electronics for Digital Healthcare
Ma, Y., Zhang, Y., Cai, S., Han, Z., Liu, X., Wang, F., Cao, Y., Wang, Z., Li, H., Chen, Y., et al. (2020) · Advanced Materials · doi:10.1002/adma.201902062 · Cited by 620 · see citing works
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454 · see citing works
“All images reproduced under the terms of the Creative Commons Attribution License: (A) (Christie et al., 2017), (B) (Elyahoodayan et al., 2020), (C) (González-González et al., 2018), (D) (Zelechowski et al., 2020), (E) (Strauss et al., 2019), (F) (de la Oliva et al., 2018), (G,H) (MacEwan et al.,…”
MethodZhang, Y., Zheng, N., Cao, Y., Wang, F., Wang, P., Ma, Y., Lu, B., Hou, G., Fang, Z., Liang, Z., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw1066 · Cited by 314 · see citing works
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133 · see citing works
Compliant peripheral nerve interfaces.
Paggi, V., Akouissi, O., Micera, S., & Lacour, S. P. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abcdbe · Cited by 60 · see citing works
“Electrochemically, coatings such as Pt black, IrOx and TiN are known to improve safety and stability of stimulation delivery [133], and can decrease electrode impedance ensuring better quality recordings [220].”
BackgroundA shape-memory and spiral light-emitting device for precise multisite stimulation of nerve bundles
Zheng, H., Zhang, Z., Jiang, S., Yan, B., Shi, X., Xie, Y., Huang, X., Yu, Z., Liu, H., Weng, S., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-10418-3 · Cited by 58 · see citing works
Recent progress on peripheral neural interface technology towards bioelectronic medicine
Cho, Y., Park, J., Lee, C., & Lee, S. (2020) · Bioelectronic Medicine · doi:10.1186/s42234-020-00059-z · Cited by 55 · see citing works
Stretchable gold nanowire-based cuff electrodes for low-voltage peripheral nerve stimulation
Lienemann, S., Zötterman, J., Farnebo, S., & Tybrandt, K. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abfebb · Cited by 48 · see citing works
Printable microscale interfaces for long-term peripheral nerve mapping and precision control
Otchy, T. M., Michas, C., Lee, B., Gopalan, K., Nerurkar, V., Gleick, J., Semu, D., Darkwa, L., Holinski, B. J., Chew, D. J., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18032-4 · Cited by 35 · see citing works
From softening polymers to multimaterial based bioelectronic devices
Ecker, M., Joshi-Imre, A., Modi, R., Frewin, C. L., Garcia-Sandoval, A., Maeng, J., Gutierrez-Heredia, G., Pancrazio, J. J., & Voit, W. E. (2019) · Multifunctional Materials · doi:10.1088/2399-7532/aaed58 · Cited by 34 · see citing works
Self-citation
- Authors
- González-González, M. A., Kanneganti, A., Joshi-Imre, A., Hernandez-Reynoso, A. G., Bendale, G., Modi, R., Ecker, M., Khurram, A., Cogan, S. F., Voit, W. E., & Romero-Ortega, M. I.
- Affiliations
- The University of Texas at Dallas (US)
- ORCID
- Venue
- Scientific Reports
- Published
- 2018-11-06
- Volume
- 8
- Issue
- 1
- Pages
- 16390-16390
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC6219541
- OpenAlex
- W2899504607
- Cited by
- 97
- References
- 57
- Citations by year
- 2026: 4 · 2025: 10 · 2024: 15 · 2023: 14 · 2022: 12 · 2021: 16 · 2020: 10 · 2019: 15 · 2018: 1
- FWCI
- 4.78
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Scientific Reports (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, other-oa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- GlaxoSmithKline foundation (1402127)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Keywords
- cuff electrodes, shape memory polymers, thin film electrodes, current steering, peripheral nerve interfaces, neural recording, sciatic nerve, pelvic nerve, fibrosis, inflammation, macrophages, vimentin, titanium nitride electrodes, gold electrode
- MeSH terms
- Animals, Electric Stimulation, Electrochemistry, Electrodes, Implanted, Equipment Design, Evoked Potentials, Female, Fibrosis, Sciatic Nerve, Silicones, Rats, Mechanical Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review