Neurological and neurosurgical diseases encompass a broad spectrum of conditions that may present with acute or chronic courses, benign or malignant characteristics, diverse clinical manifestations, and prolonged recovery periods. Various assessment approaches are available for the early diagnosis, treatment planning, and timely intervention of these diseases. Several scales and scoring systems are used in their evaluation. One such assessment method is the measurement of the pupil and pupillary light reflex, which provides information about the sympathetic and parasympathetic branches of the autonomic nervous system, offers guidance regarding various neural structures, and enables an inexpensive and simple evaluation of patients’ clinical course. In recent years, technological advancements have enabled the objective measurement of this reflex through portable infrared pupillometry devices, thereby aiming to minimize inter-observer variability. However, due to the high cost of such objective assessment tools, many healthcare institutions may be unable to include them in their inventory. Consequently, pupil evaluation using a light source and pupil gauge, performed by healthcare professionals, remains a simple and practical method. To reduce potential inconsistencies in the evaluation process, it is essential that healthcare personnel possess adequate knowledge and practical experience in pupil assessment. This article reviews and synthesizes the relevant literature on pupil evaluation.

Overview

CoChat Summary

TL;DR

This narrative review synthesizes the literature on pupillary assessment and the pupillary light reflex, covering anatomy, assessment methods (manual penlight, automated infrared pupillometry, and digital/AI-based systems), and clinical applications across neurological, metabolic, and anesthetic contexts. It argues that manual assessment remains the most accessible method but is subjective, while quantitative pupillometry offers objective, reproducible data that is limited by cost and availability.

Key findings

  • Manual pupil assessment with a light source and pupil gauge remains the most widely used method due to low cost and ease of use, but it is largely subjective: studies cited report low interobserver agreement, with Kerr et al. finding intensive care and neurosurgical nurses systematically underestimate true pupil diameter, and Couret et al. finding interobserver agreement could not be reliably established.
  • Automated infrared pupillometry provides objective, quantitative, reproducible measurement, with the Neurological Pupil Index (NPi) reported as associated with increased intracranial pressure, risk of herniation, and poor neurological outcomes; low NPi values early after return of spontaneous circulation are described as a significant biomarker for poor neurological prognosis after cardiac arrest.
  • Normal pupil size is stated as 2–6 mm, with anisocoria of less than 0.5 mm considered within normal limits; anisocoria up to approximately 0.5 mm may occur in healthy adults without pathology.
  • Digital, smartphone-based, and AI-supported pupillometry (e.g., the Pupil Reactivity/PuRe score) shows promise for reliable assessment under variable lighting and in resource-limited or field settings, but the paper states these should currently be considered supportive tools rather than standalone methods pending large-scale prospective validation.

Methods

  • Design: narrative literature review ("This article reviews and synthesizes the relevant literature on pupil evaluation"); no primary data collection.
  • Data/sample: Not stated in the paper (no systematic search strategy, databases, date range, or inclusion/exclusion criteria are reported).
  • Analysis: Not stated in the paper; the text is organized thematically into sections on pupil anatomy, pupillary conditions, assessment methods, factors affecting assessment, disease states, and digital health approaches.

Limitations

  • Stated by the paper: "pupil assessment... remains a subject with a limited number of studies in the literature"; the authors also note that device cost and lack of measurement standardization limit widespread pupillometry use, and that large-scale prospective validation studies are required before digital/AI systems are fully integrated.
  • Evident from the text: as a narrative review, it does not describe a systematic search strategy, inclusion/exclusion criteria, or critical appraisal of included sources, so selection bias in cited literature cannot be assessed.
  • Evident from the text: several cited sources are preprints (e.g., Veerapaneni et al., medRxiv 2024) or pilot studies, and some claims are attributed to references without reporting effect sizes or sample sizes, limiting the strength of the synthesized evidence.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.54803/sauhsd.1767753

Cites

51 of 52 references verified0 citation errors · 1 not checkable

Statistics

Nothing to recompute.

Figures

Image 1
CC-BY-NC · From the PDF
Figure 1 Penlight with Pupil Gauge Design (28)
Figure 1 Penlight with Pupil Gauge Design (28)CC-BY-NC · From the PDF
Figure 2 Portable Infrared Pupillometer (5,12)
Figure 2 Portable Infrared Pupillometer (5,12)CC-BY-NC · From the PDF

Verification

Claims the paper makes

0 Valid · 0 Not valid · 76 Not checked · 23 Own results and interpretations

46 more claims

Create a free account to see all 99 claims and to verify the 123 references still open.

See all claims — free account
  • It may state two separate claims as one. 35
  • Probably not a substantial claim. 16

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

2 of 2

Citations

Cites

Research works printed but not linked: 2

  1. Sepit D. Bilinç durumunun değerlendirilmesi ve glasgow koma skalası. Hemşirelikte Eğitim ve Araştırma Dergisi. 2005;2(1):12-6.
  2. Akyüz G, Akdeniz Leblebicier M. Otonom sinir sistemi anatomisi ve değerlendirilmesi. Turk J Phys Med Rehabil. 2012;58(1):1-5.

Cited by

Metadata

Authors
Özdağ, D., & Oztas, B.
Affiliations
UNIVERSITY OF HEALTH SCIENCES, GULHANE SCHOOL OF NURSING, DEPARTMENT OF NURSING SCIENCE
Corresponding author
Özdağ, Didem
Venue
Sakarya Üniversitesi Holistik Sağlık Dergisi
Published
2025-12-29
Issue
Advanced Online Publication
Pages
189-200
ISSN
2687-6078 (ISSN-L)
OpenAlex
W7117459937
Cited by
1
References
50
Citations by year
2026: 1
FWCI
0.61
Type
journal article
Language
en
Open access
Licence
cc-by-nc
Locations
  • Sakarya Üniversitesi Holistik Sağlık Dergisi (publishedVersion, cc-by-nc)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Health Research
  • Health Sciences › Medicine › Ophthalmology › Ophthalmology and Eye Disorders
  • Health Sciences › Medicine › Clinical Neurology › Peripheral Nerve Disorders
Keywords
pupil assessment, pupillary light reflex, pupillometry, autonomic nervous system, sympathetic nervous system, parasympathetic nervous system, neurological assessment, interobserver variability

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-22, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-22 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.