Microneedles (MNs) are playing an increasingly important role in biomedical applications, where minimally invasive methods are being developed that require imperceptible tissue penetration and drug delivery. To improve the integration of MNs in microelectromechanical devices, a high‐resolution 3D printing technique is implemented. A reservoir with an array of hollow MNs is produced. The flow rate through the MNs is simulated and measured experimentally. The mechanical properties of the 3D printed material, such as elasticity modulus and yield strength, are investigated as functions of printing parameters, reaching maximum values of 1750.7 and 101.8 MPa, respectively. Analytical estimation of the MN buckling, fracture, and skin penetration forces is presented. Penetration tests of MNs into a skin‐like material are conducted, where the piercing force ranges from 0.095 to 0.115 N, confirming sufficient stability of MNs. Furthermore, 200 and 400 μm‐long MN arrays are used to successfully pierce and deliver into mouse skin with an average penetration depth of 100 and 180 μm, respectively. A biocompatibility assessment is performed, showing a high viability of HCT 116 cells cultured on top of the MN's material, making the developed MNs a very attractive solution for many biomedical applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adem.201901358

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 44

  1. 10.1111/jphp.12152 · DOI
  2. 10.1016/j.addr.2018.03.011 · DOI · Paper page
  3. 10.1002/aic.690210522 · DOI · Paper page
  4. 10.1016/j.jconrel.2014.07.007 · doi:10.1016/j.jconrel.2014.07.007
  5. 10.1016/j.jconrel.2016.05.002 · DOI
  6. 10.1016/j.jconrel.2017.10.007 · DOI
  7. 10.1016/j.sna.2017.05.007 · DOI
  8. 10.1002/adem.201800471 · DOI
  9. 10.1038/srep28539 · DOI
  10. 10.1007/s11095-016-1885-5 · DOI · Paper page
  11. 10.1038/s41598-018-28194-3 · DOI
  12. 10.1016/j.jconrel.2014.04.052 · DOI · Paper page
  13. 10.1023/B:BMMD.0000042046.07678.2e · DOI
  14. 10.1007/s10544-008-9259-3 · doi:10.1007/s10544-008-9259-3
  15. 10.1016/j.sna.2003.11.008 · DOI · Paper page
  16. 10.1109/JMEMS.2005.844843 · DOI · Paper page
  17. 10.1038/sj.jid.5700150 · DOI · Paper page
  18. 10.1109/TBME.2006.889173 · DOI · Paper page
  19. 10.1007/s11095-010-0169-8 · DOI · Paper page
  20. 10.1109/TBME.2005.845240 · DOI · Paper page
  21. 10.1007/s10544-012-9683-2 · DOI
  22. 10.1088/0960-1317/14/4/021 · DOI · Paper page
  23. 10.1039/c2lc40348j · DOI
  24. 10.1039/C5LC00669D · DOI
  25. 10.1007/s00542-004-0446-8 · DOI
  26. 10.1016/j.ejps.2019.104976 · DOI
  27. F.Lacan S.Coulman A.Hotston P.Petkov J.Birchall presented atProceedings of the 10th International Conference on Multi-Material Micro Manufacture Singapore October 2013.
  28. 10.1016/j.ijpharm.2018.03.031 · DOI · Paper page
  29. 10.1088/1758-5090/7/4/045001 · DOI · Paper page
  30. 10.3390/mi9020085 · DOI
  31. 10.3390/bioengineering5030059 · DOI · Paper page
  32. 10.1039/C8LC00098K · DOI · Paper page
  33. 10.1016/j.bios.2014.11.010 · DOI
  34. 10.1007/s00542-006-0221-0 · DOI
  35. 10.1109/JMEMS.2018.2819994 · DOI
  36. K.Moussi A.Bukhamsin J.Kosel 20th International Conference on Solid-State Sensors Actuators and Microsystems & Eurosensors XXXIII (TRANSDUCERS & EUROSENSORS XXXIII) IEEE Piscataway New Jersey US 2019.
  37. 10.1016/j.jbiomech.2003.12.010 · DOI · Paper page
  38. 10.1088/0960-1317/20/4/045011 · DOI
  39. 10.1002/app.41029 · DOI · Paper page
  40. International Organization for Standardization, 2009, Biological Evaluation of Medical Devices — Part 5: Tests for in Vitro Cytotoxicity
  41. International Organization for Standardization, 2012, Biological Evaluation of Medical Devices — Part 12: Sample Preparation and Reference Material
  42. 10.1109/JMEMS.2007.907461 · DOI · Paper page
  43. 10.1016/j.jconrel.2006.02.017 · DOI · Paper page
  44. 10.1080/01694243.2012.705101 · DOI

Cited by

See all 65

Metadata

Authors
Moussi, K., Bukhamsin, A., Hidalgo, T., & Kosel, J.
Affiliations
  • Computer, Electrical and Mathematical Sciences and Engineering Division (CEMSE) 4700 King Abdullah University of Science and Technology (KAUST) Thuwal 23955 Kingdom of Saudi Arabia
  • Biological and Environmental Science and Engineering Division (BESE) 4700 King Abdullah University of Science and Technology (KAUST) Thuwal 23955 Kingdom of Saudi Arabia
Venue
Advanced Engineering Materials
Publisher
Wiley
Published
2019-12-15
Volume
22
Issue
2
ISSN
  • 1438-1656
  • 1527-2648
Cited by
65
References
1
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.