Organ‐On‐A‐Chip Platforms: A Convergence of Advanced Materials, Cells, and Microscale Technologies
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Adv. Healthcare Mater. 2018, 7, 1700506 In this article, the following reference was erroneously published: [338] G. T. Vladisavljevic, I. Kobayashi, M. Nakajima, Microfluid. Nanofluid. 2012, 13, 151. Additionally, Section 5.3. should be corrected to: For example, Bischel at al. introduced a cell-laden hydrogel inside a microfluidic channel to create a lumen (Figure 4A).[339] Trietsch et al. constructed a microfluidic plate system having 96 chambers. The flow between microfluidic chambers was provided using passive pressure without using external pumps (Figure 4B)[340] Ataç et al. showed a coculture of skin tissue with hair follicles in a microfluidic Boyden chamber-like system (Figure 4C).[168] An additional reference should be cited at the end of the following sentence on page 15, “Frey et al. demonstrated a perfused system of colorectal cancer spheroids and liver. Drug metabolism was studied using this system (Figure 4D)”. The additional reference is: O. Frey, P. M. Misun, D. A. Fluri, J. G. Hengstler, A. Hierlemann, Nat. Commun. 2014, 5, 4250. The authors apologize for these errors and any confusion this may have caused.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The blood-brain barrier: Bottleneck in brain drug development
Pardridge, W. M. (2005) · NeuroRX · doi:10.1602/neurorx.2.1.3 · Cited by 2,798
Alginate hydrogels as synthetic extracellular matrix materials
Rowley, J. A., Madlambayan, G., & Mooney, D. J. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00107-0 · Cited by 2,342
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Three-dimensional bioprinting of thick vascularized tissues
Kolesky, D. B., Homan, K. A., Skylar-Scott, M. A., & Lewis, J. A. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1521342113 · Cited by 1,492
Bioactive modification of poly (ethylene glycol) hydrogels for tissue engineering
Zhu, J. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.02.044 · Cited by 1,457
Efficient and rapid generation of induced pluripotent stem cells from human keratinocytes
Aasen, T., Raya, A., Barrero, M. J., Garreta, E., Consiglio, A., Gonzalez, F., Vassena, R., Bilić, J., Pekarik, V., Tiscornia, G., et al. (2008) · Nature Biotechnology · doi:10.1038/nbt.1503 · Cited by 1,423
Human cardiovascular progenitor cells develop from a KDR+ embryonic-stem-cell-derived population
Yang, L., Soonpaa, M. H., Adler, E. D., Roepke, T. K., Kattman, S. J., Kennedy, M., Henckaerts, E., Bonham, K., Abbott, G. W., Linden, R. M., et al. (2008) · Nature · doi:10.1038/nature06894 · Cited by 1,389
Nanotechnological strategies for engineering complex tissues
Dvir, T., Timko, B. P., Kohane, D. S., & Langer, R. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2010.246 · Cited by 1,367
Microscale culture of human liver cells for drug development
Khetani, S. R., & Bhatia, S. N. (2008) · Nature Biotechnology · doi:10.1038/nbt1361 · Cited by 1,219
Growing Self-Organizing Mini-Guts from a Single Intestinal Stem Cell: Mechanism and Applications
Sato, T., & Clevers, H. (2013) · Science · doi:10.1126/science.1234852 · Cited by 1,170
In vitro cell migration and invasion assays
Kramer, N., Walzl, A., Unger, C., Rosner, M., Krupitza, G., Hengstschläger, M., & Dolznig, H. (2013) · Mutation Research/Reviews in Mutation Research · doi:10.1016/j.mrrev.2012.08.001 · Cited by 1,170
Generation of human induced pluripotent stem cells from dermal fibroblasts
Lowry, W. E., Richter, L., Yachechko, R., Pyle, A. D., Tchieu, J., Sridharan, R., Clark, A. T., & Plath, K. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0711983105 · Cited by 1,041
A Human Disease Model of Drug Toxicity–Induced Pulmonary Edema in a Lung-on-a-Chip Microdevice
Huh, D., Leslie, D. C., Matthews, B. D., Fraser, J. P., Jurek, S., Hamilton, G. A., Thorneloe, K. S., McAlexander, M. A., & Ingber, D. E. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004249 · Cited by 993
Biowire: a platform for maturation of human pluripotent stem cell–derived cardiomyocytes
Nunes, S. S., Miklas, J. W., Liu, J., Aschar-Sobbi, R., Xiao, Y., Zhang, B., Jiang, J., Massé, S., Gagliardi, M., Hsieh, A., et al. (2013) · Nature Methods · doi:10.1038/nmeth.2524 · Cited by 952
Self-citationIn vitro microvessels for the study of angiogenesis and thrombosis
Zheng, Y., Chen, J., Craven, M., Choi, N. W., Totorica, S., Diaz-Santana, A., Kermani, P., Hempstead, B., Fischbach-Teschl, C., López, J. A., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1201240109 · Cited by 894
Comparison of 2D- and 3D-culture models as drug-testing platforms in breast cancer
IMAMURA, Y., MUKOHARA, T., SHIMONO, Y., FUNAKOSHI, Y., CHAYAHARA, N., TOYODA, M., KIYOTA, N., TAKAO, S., KONO, S., NAKATSURA, T., et al. (2015) · Oncology Reports · doi:10.3892/or.2015.3767 · Cited by 845
Wang, G., McCain, M. L., Yang, L., He, A., Pasqualini, F. S., Agarwal, A., Yuan, H., Jiang, D., Zhang, D., Zangi, L., et al. (2014) · Nature Medicine · doi:10.1038/nm.3545 · Cited by 837
Bioprinting of 3D convoluted renal proximal tubules on perfusable chips
Homan, K. A., Kolesky, D. B., Skylar-Scott, M. A., Herrmann, J., Obuobi, H., Moisan, A., & Lewis, J. A. (2016) · Scientific Reports · doi:10.1038/srep34845 · Cited by 699
Pluripotent stem cells in disease modelling and drug discovery
Avior, Y., Sagi, I., & Benvenisty, N. (2016) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm.2015.27 · Cited by 592
Microfluidic 3D cell culture: from tools to tissue models
van Duinen, V., Trietsch, S. J., Joore, J., Vulto, P., & Hankemeier, T. (2015) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2015.05.002 · Cited by 500
Amacrine-Signaled Loss of Intrinsic Axon Growth Ability by Retinal Ganglion Cells
Goldberg, J. L., Klassen, M. P., Hua, Y., & Barres, B. A. (2002) · Science · doi:10.1126/science.1068428 · Cited by 488
Kidney-on-a-Chip technology for drug-induced nephrotoxicity screening
Wilmer, M. J., Ng, C. P., Lanz, H. L., Vulto, P., Suter-Dick, L., & Masereeuw, R. (2016) · Trends in Biotechnology · doi:10.1016/j.tibtech.2015.11.001 · Cited by 354
Organ-on-a chip systems: microengineering to biomimic living systems
Zheng, F., Fu, F., Cheng, Y., Wang, C., Zhao, Y., & Gu, Z. (2016) · Small · doi:10.1002/smll.201503208 · Cited by 338
Self-citationLee, S.-A., No, D. Y., Kang, E., Ju, J., Kim, D.-S., & Lee, S.-H. (2013) · Lab on a Chip · doi:10.1039/c3lc50197c · Cited by 297
Maturing human pluripotent stem cell-derived cardiomyocytes in human engineered cardiac tissues
Feric, N. T., & Radisic, M. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.04.019 · Cited by 247
Self-citationMicromolded gelatin hydrogels for extended culture of engineered cardiac tissues
McCain, M. L., Agarwal, A., Nesmith, H. W., Nesmith, A. P., & Parker, K. K. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.03.052 · Cited by 237
Skardal, A., Devarasetty, M., Forsythe, S., Atala, A., & Soker, S. (2016) · Biotechnology and Bioengineering · doi:10.1002/bit.25950 · Cited by 230
Microfluidic Organ‐on‐a‐Chip Technology for Advancement of Drug Development and Toxicology
Caplin, J. D., Granados, N. G., James, M. R., Montazami, R., & Hashemi, N. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500040 · Cited by 205
Buchanan, C. F., Verbridge, S. S., Vlachos, P. P., & Rylander, M. N. (2014) · Cell Adhesion & Migration · doi:10.4161/19336918.2014.970001 · Cited by 205
DECREASED mRNA EXPRESSION OF TIGHT JUNCTION PROTEINS IN LUMBAR SPINAL CORDS OF PATIENTS WITH ALS
Henkel, J. S., Beers, D. R., Wen, S., Bowser, R., & Appel, S. H. (2009) · Neurology · doi:10.1212/wnl.0b013e3181a41228 · Cited by 153
A microfluidic-based device for study of transendothelial invasion of tumor aggregates in realtime
Zhang, Q., Liu, T., & Qin, J. (2012) · Lab on a Chip · doi:10.1039/c2lc00030j · Cited by 151
Hydrogel-coated microfluidic channels for cardiomyocyte culture
Annabi, N., Selimović, Š., Acevedo Cox, J. P., Ribas, J., Afshar Bakooshli, M., Heintze, D., Weiss, A. S., Cropek, D., & Khademhosseini, A. (2013) · Lab on a Chip · doi:10.1039/c3lc50252j · Cited by 129
Approaching the in vitro clinical trial: engineering organs on chips
Capulli, A. K., Tian, K., Mehandru, N., Bukhta, A., Choudhury, S. F., Suchyta, M., & Parker, K. K. (2014) · Lab on a Chip · doi:10.1039/c4lc00276h · Cited by 111
Matsa, E., Ahrens, J. H., & Wu, J. C. (2016) · Physiological Reviews · doi:10.1152/physrev.00036.2015 · Cited by 105
Paradigms for Mechanical Signal Transduction in the Intestinal Epithelium
Basson, M. D. (2003) · Digestion · doi:10.1159/000076385 · Cited by 73
Al‐Abboodi, A., Tjeung, R., Doran, P. M., Yeo, L. Y., Friend, J., & Yik Chan, P. P. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201400072 · Cited by 27
Cited by
Zamprogno, P., Wüthrich, S., Achenbach, S., Thoma, G., Stucki, J. D., Hobi, N., Schneider-Daum, N., Lehr, C.-M., Huwer, H., Geiser, T., et al. (2021) · Communications Biology · doi:10.1038/s42003-021-01695-0 · Cited by 348
Evolution of Biochip Technology: A Review from Lab-on-a-Chip to Organ-on-a-Chip
Azizipour, N., Avazpour, R., Rosenzweig, D. H., Sawan, M., & Ajji, A. (2020) · Micromachines · doi:10.3390/mi11060599 · Cited by 277
Advances and Future Perspectives in 4D Bioprinting
Ashammakhi, N., Ahadian, S., Zengjie, F., Suthiwanich, K., Lorestani, F., Orive, G., Ostrovidov, S., & Khademhosseini, A. (2018) · Biotechnology Journal · doi:10.1002/biot.201800148 · Cited by 270
Self-citationOrgan-on-a-chip meets artificial intelligence in drug evaluation
Deng, S., Li, C., Cao, J., Cui, Z., Du, J., Fu, Z., Yang, H., & Chen, P. (2023) · Theranostics · doi:10.7150/thno.87266 · Cited by 260
Bain, C. C., & MacDonald, A. S. (2022) · Mucosal Immunology · doi:10.1038/s41385-021-00480-w · Cited by 255
Metadata
- Authors
- Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., Mandla, S., Korolj, A., & Radisic, M.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2018-07
- Volume
- 7
- Issue
- 14
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W4242487932
- Cited by
- 95
- References
- 36
- FWCI
- 4.34
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.