D–A Type NIR‐II Organic Molecules: Strategies for the Enhancement Fluorescence Brightness and Applications in NIR‐II Fluorescence Imaging‐Navigated Photothermal Therapy
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
NIR‐II fluorescence imaging (NIR‐II FI) and photothermal therapy (PTT) have received broad attentions in precise tumor diagnosis and effective treatment attributed to high‐resolution and deep tissue imaging, negligible invasivity, and high‐efficiency treatment. Although many fluorescent molecules have been designed and conducted for NIR‐II FI and PTT, it is still an enormous challenge for researchers to pioneer some rational design guidelines to improve fluorescence brightness. Organic D–A‐type molecules, including small molecules and conjugated polymers, can be designed and developed to improve fluorescence brightness due to their tunable and easy functionalized chemical structures, allowing molecules tailored photophysical properties. In this review, some approaches to the development and design strategies of D–A type small molecules and conjugated polymers for the enhancement of fluorescence brightness are systemically introduced. Meanwhile, some applications of PTT and PTT‐based combination therapy (such as PDT, chemotherapy, or gas therapy) assisted by NIR‐II FI‐based single or multiimaging technologies are classified and represented in detail as well. Finally, the current issues and challenges of NIR‐II organic molecules in NIR‐II FI‐navigated PTT are summarized and discussed, which gives some guidelines for the future development direction of NIR‐II organic molecules for NIR‐II FI‐navigated PTT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
Advanced Fluorescence Imaging Technology in the Near-Infrared-II Window for Biomedical Applications
Li, C., Chen, G., Zhang, Y., Wu, F., & Wang, Q. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c07022 · Cited by 1,037
A high quantum yield molecule-protein complex fluorophore for near-infrared II imaging
Antaris, A. L., Chen, H., Diao, S., Ma, Z., Zhang, Z., Zhu, S., Wang, J., Lozano, A. X., Fan, Q., Chew, L., et al. (2017) · Nature Communications · doi:10.1038/ncomms15269 · Cited by 623
J -Aggregates of Cyanine Dye for NIR-II in Vivo Dynamic Vascular Imaging beyond 1500 nm
Sun, C., Li, B., Zhao, M., Wang, S., Lei, Z., Lu, L., Zhang, H., Feng, L., Dou, C., Yin, D., et al. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b10043 · Cited by 582
Donor Engineering for NIR-II Molecular Fluorophores with Enhanced Fluorescent Performance
Yang, Q., Hu, Z., Zhu, S., Ma, R., Ma, H., Ma, Z., Wan, H., Zhu, T., Jiang, Z., Liu, W., et al. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.7b10334 · Cited by 554
Traumatic Brain Injury Imaging in the Second Near‐Infrared Window with a Molecular Fluorophore
Zhang, X., Wang, H., Antaris, A. L., Li, L., Diao, S., Ma, R., Nguyen, A., Hong, G., Ma, Z., Wang, J., et al. (2016) · Advanced Materials · doi:10.1002/adma.201600706 · Cited by 386
Liu, S., Ou, H., Li, Y., Zhang, H., Liu, J., Lu, X., Kwok, R. T. K., Lam, J. W. Y., Ding, D., & Tang, B. Z. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c07193 · Cited by 277
NIR-II bioimaging of small organic molecule
Su, Y., Yu, B., Wang, S., Cong, H., & Shen, Y. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2021.120717 · Cited by 251
Zhang, Q., Yu, P., Fan, Y., Sun, C., He, H., Liu, X., Lu, L., Zhao, M., Zhang, H., & Zhang, F. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202012427 · Cited by 216
Novel NIR-II organic fluorophores for bioimaging beyond 1550 nm
Li, Y., Liu, Y., Li, Q., Zeng, X., Tian, T., Zhou, W., Cui, Y., Wang, X., Cheng, X., Ding, Q., et al. (2020) · Chemical Science · doi:10.1039/c9sc06567a · Cited by 177
Cited by
Wang, L., Li, N., Wang, W., Mei, A., Shao, J., Wang, W., & Dong, X. (2024) · ACS Nano · doi:10.1021/acsnano.3c12316 · Cited by 127
Liu, Y., Ran, X., Zhou, D., Zhang, H., Chen, Y., Xu, J., Chen, S., Kong, Q., Yu, X., & Li, K. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202311365 · Cited by 69
Self-citationCheng, P., Du, X., Chen, S., Chen, K., Yuan, Y., Shao, J., Shen, Q., Sun, P., & Fan, Q. (2023) · ACS Applied Nano Materials · doi:10.1021/acsanm.3c01749 · Cited by 29
Self-citationAdvances on fluorescence bioimaging and photo-mediated therapy of NIR-II small molecule dyes
Zhang, W., Laraib, Huo, F., & Yin, C. (2025) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2025.216587 · Cited by 26
Activatable Molecular Probes With Clinical Promise for NIR‐II Fluorescent Imaging
Chen, Z., Zhou, Y., Li, L., Ma, W., Li, Y., & Yang, Z. (2025) · Small · doi:10.1002/smll.202411787 · Cited by 26
Miao, X., Jia, M., Weng, X., Zhang, J., Pan, Y., Zhao, H., Yu, Z., Fan, Q., & Hu, W. (2025) · Light: Science & Applications · doi:10.1038/s41377-025-01787-0 · Cited by 25
“To develop bright NIR-II fl uorophores, two primary strategies have been established by donor-acceptor (D-A) engineering and conjugation extension 9 – 15 .”
Molecularly Locked π ‐Bridge Endows AIEgen with 1064 nm Excitation for Deep Tissue Imaging
Liu, W., Xie, H., Liu, J., Zhu, N., Wang, S., Wang, R., Zhang, X., Xu, G., Genin, G. M., Xu, F., et al. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202501668 · Cited by 12
Metadata
- Authors
- Chen, Y., Chen, S., Yu, H., Wang, Y., Cui, M., Wang, P., Sun, P., & Ji, M.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2022-09-07
- Volume
- 11
- Issue
- 21
- Pages
- e2201158-e2201158
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W4290787220
- Cited by
- 94
- References
- 24
- FWCI
- 5.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.