The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
“Dual Lock‐and‐Key”‐Controlled Nanoprobes for Ultrahigh Specific Fluorescence Imaging in the Second Near‐Infrared Window
Abstract
Fluorescence imaging in the second near‐infrared window (NIR‐II) is a new technique that permits visualization of deep anatomical features with unprecedented spatial resolution. Although attractive, effectively suppressing the interference signal of the background is still an enormous challenge for obtaining target‐specific NIR‐II imaging in the complex and dynamic physiological environment. Herein, dual‐pathological‐parameter cooperatively activatable NIR‐II fluorescence nanoprobes (HISSNPs) are developed whereby hyaluronic acid chains and disulfide bonds act as the “double locks” to lock the fluorescence‐quenched aggregation state of the NIR‐II fluorescence dyes for performing ultrahigh specific imaging of tumors in vivo. The fluorescence can be lit up only when the “double locks” are opened by reacting with the “dual smart keys” (overexpressed hyaluronidase and thiols in tumor) simultaneously. In vivo NIR‐II imaging shows that they reduce nonspecific activitation and achieve ultralow background fluorescence, which is 10.6‐fold lower than single‐parameter activatable probes (HINPs) in the liver at 15 h postinjection. Consequently, these “dual lock‐and‐key”‐controlled HISSNPs exhibit fivefold higher tumor‐to‐normal tissue ratio than “single lock‐and‐key”‐controlled HINPs at 24 h postinjection, attractively realizing ultrahigh specificity of tumor imaging. This is thought to be the first attempt at implementing ultralow background interference with the participation of multiple pathological parameters in NIR‐II fluorescence imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Second window for in vivo imaging
Smith, A. M., Mancini, M. C., & Nie, S. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.326 · Cited by 2,848
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
Self-citationWelsher, K., Sherlock, S. P., & Dai, H. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1014501108 · Cited by 958
Next-generation in vivo optical imaging with short-wave infrared quantum dots
Bruns, O. T., Bischof, T. S., Harris, D. K., Franke, D., Shi, Y., Riedemann, L., Bartelt, A., Jaworski, F. B., Carr, J. A., Rowlands, C. J., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0056 · Cited by 686
A high quantum yield molecule-protein complex fluorophore for near-infrared II imaging
Antaris, A. L., Chen, H., Diao, S., Ma, Z., Zhang, Z., Zhu, S., Wang, J., Lozano, A. X., Fan, Q., Chew, L., et al. (2017) · Nature Communications · doi:10.1038/ncomms15269 · Cited by 623
Self-citationHong, G., Zou, Y., Antaris, A. L., Diao, S., Wu, D., Cheng, K., Zhang, X., Chen, C., Liu, B., He, Y., et al. (2014) · Nature Communications · doi:10.1038/ncomms5206 · Cited by 563
Donor Engineering for NIR-II Molecular Fluorophores with Enhanced Fluorescent Performance
Yang, Q., Hu, Z., Zhu, S., Ma, R., Ma, H., Ma, Z., Wan, H., Zhu, T., Jiang, Z., Liu, W., et al. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.7b10334 · Cited by 554
Qi, J., Sun, C., Zebibula, A., Zhang, H., Kwok, R. T. K., Zhao, X., Xi, W., Lam, J. W. Y., Qian, J., & Tang, B. Z. (2018) · Advanced Materials · doi:10.1002/adma.201706856 · Cited by 418
Traumatic Brain Injury Imaging in the Second Near‐Infrared Window with a Molecular Fluorophore
Zhang, X., Wang, H., Antaris, A. L., Li, L., Diao, S., Ma, R., Nguyen, A., Hong, G., Ma, Z., Wang, J., et al. (2016) · Advanced Materials · doi:10.1002/adma.201600706 · Cited by 386
Cited by
Advanced Fluorescence Imaging Technology in the Near-Infrared-II Window for Biomedical Applications
Li, C., Chen, G., Zhang, Y., Wu, F., & Wang, Q. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c07022 · Cited by 1,037
Optical nano-agents in the second near-infrared window for biomedical applications
Cai, Y., Wei, Z., Song, C., Tang, C., Han, W., & Dong, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00494c · Cited by 603
J -Aggregates of Cyanine Dye for NIR-II in Vivo Dynamic Vascular Imaging beyond 1500 nm
Sun, C., Li, B., Zhao, M., Wang, S., Lei, Z., Lu, L., Zhang, H., Feng, L., Dou, C., Yin, D., et al. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b10043 · Cited by 582
Semiconducting Polymer Nanomaterials as Near-Infrared Photoactivatable Protherapeutics for Cancer
Li, J., & Pu, K. (2020) · Accounts of Chemical Research · doi:10.1021/acs.accounts.9b00569 · Cited by 412
Lei, Z., Sun, C., Pei, P., Wang, S., Li, D., Zhang, X., & Zhang, F. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201904182 · Cited by 362
Metadata
- Authors
- Tang, Y., Li, Y., Hu, X., Zhao, H., Ji, Y., Chen, L., Hu, W., Zhang, W., Li, X., Lu, X., Huang, W., & Fan, Q.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2018-06-19
- Volume
- 30
- Issue
- 31
- Pages
- e1801140-e1801140
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2809066027
- Cited by
- 203
- References
- 9
- FWCI
- 10.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: “Dual Lock‐and‐Key”‐Controlled Nanoprobes for Ultrahigh Specific Fluorescence Imaging in the Second Near‐Infrared Window. https://app.cochat.ai/papers/10.1002/adma.201801140
- The paper
- Tang, Y., Li, Y., Hu, X., Zhao, H., Ji, Y., Chen, L., Hu, W., Zhang, W., Li, X., Lu, X., Huang, W., & Fan, Q. (2018). “Dual Lock‐and‐Key”‐Controlled Nanoprobes for Ultrahigh Specific Fluorescence Imaging in the Second Near‐Infrared Window. Advanced Materials. https://doi.org/10.1002/adma.201801140
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.