Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 203

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

“Dual Lock‐and‐Key”‐Controlled Nanoprobes for Ultrahigh Specific Fluorescence Imaging in the Second Near‐Infrared Window

Tang, Yufu, Li, Yuanyuan, Hu, Xiaoming, Zhao, Hui, Ji, Yu, Chen, Liang, Hu, Wenbo, Zhang, Wansu, Li, Xiang, Lu, Xiaomei, Huang, Wei, Fan, Quli·2018·Advanced Materials

Abstract

Fluorescence imaging in the second near‐infrared window (NIR‐II) is a new technique that permits visualization of deep anatomical features with unprecedented spatial resolution. Although attractive, effectively suppressing the interference signal of the background is still an enormous challenge for obtaining target‐specific NIR‐II imaging in the complex and dynamic physiological environment. Herein, dual‐pathological‐parameter cooperatively activatable NIR‐II fluorescence nanoprobes (HISSNPs) are developed whereby hyaluronic acid chains and disulfide bonds act as the “double locks” to lock the fluorescence‐quenched aggregation state of the NIR‐II fluorescence dyes for performing ultrahigh specific imaging of tumors in vivo. The fluorescence can be lit up only when the “double locks” are opened by reacting with the “dual smart keys” (overexpressed hyaluronidase and thiols in tumor) simultaneously. In vivo NIR‐II imaging shows that they reduce nonspecific activitation and achieve ultralow background fluorescence, which is 10.6‐fold lower than single‐parameter activatable probes (HINPs) in the liver at 15 h postinjection. Consequently, these “dual lock‐and‐key”‐controlled HISSNPs exhibit fivefold higher tumor‐to‐normal tissue ratio than “single lock‐and‐key”‐controlled HINPs at 24 h postinjection, attractively realizing ultrahigh specificity of tumor imaging. This is thought to be the first attempt at implementing ultralow background interference with the participation of multiple pathological parameters in NIR‐II fluorescence imaging.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adma.201801140

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 203

Metadata

Authors
Tang, Y., Li, Y., Hu, X., Zhao, H., Ji, Y., Chen, L., Hu, W., Zhang, W., Li, X., Lu, X., Huang, W., & Fan, Q.
Venue
Advanced Materials
Publisher
Wiley
Published
2018-06-19
Volume
30
Issue
31
Pages
e1801140-e1801140
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W2809066027
Cited by
203
References
9
FWCI
10.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: “Dual Lock‐and‐Key”‐Controlled Nanoprobes for Ultrahigh Specific Fluorescence Imaging in the Second Near‐Infrared Window. https://app.cochat.ai/papers/10.1002/adma.201801140
The paper
Tang, Y., Li, Y., Hu, X., Zhao, H., Ji, Y., Chen, L., Hu, W., Zhang, W., Li, X., Lu, X., Huang, W., & Fan, Q. (2018). “Dual Lock‐and‐Key”‐Controlled Nanoprobes for Ultrahigh Specific Fluorescence Imaging in the Second Near‐Infrared Window. Advanced Materials. https://doi.org/10.1002/adma.201801140

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).