CoChat

Proton‐Coupled Electron Transfer on Cu 2 O/Ti 3 C 2 T x MXene for Propane (C 3 H 8 ) Synthesis from Electrochemical CO 2 Reduction

Open access

The DOI matches its Crossref record; 108 of the 108 references it cites were found in a registry or an index.

Abstract

Electrochemical CO 2 reduction reaction (CO 2 RR) to produce value‐added multi‐carbon chemicals has been an appealing approach to achieving environmentally friendly carbon neutrality in recent years. Despite extensive research focusing on the use of CO 2 to produce high‐value chemicals like high‐energy‐density hydrocarbons, there have been few reports on the production of propane (C 3 H 8 ), which requires carbon chain elongation and protonation. A rationally designed 0D/2D hybrid Cu 2 O anchored‐Ti 3 C 2 T x MXene catalyst (Cu 2 O/MXene) is demonstrated with efficient CO 2 RR activity in an aqueous electrolyte to produce C 3 H 8 . As a result, a significantly high Faradaic efficiency (FE) of 3.3% is achieved for the synthesis of C 3 H 8 via the CO 2 RR with Cu 2 O/MXene, which is ≈26 times higher than that of Cu/MXene prepared by the same hydrothermal process without NH 4 OH solution. Based on in‐situ attenuated total reflection‐Fourier transform infrared spectroscopy (ATR‐FTIR) and density functional theory (DFT) calculations, it is proposed that the significant electrocatalytic conversion originated from the synergistic behavior of the Cu 2 O nanoparticles, which bound the *C 2 intermediates, and the MXene that bound the *CO coupling to the C 3 intermediate. The results disclose that the rationally designed MXene‐based hybrid catalyst facilitates multi‐carbon coupling as well as protonation, thereby manipulating the CO 2 RR pathway.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/advs.202405154

Cites

108 of 108 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 a) Schematic illustration of CO2RR with Cu2O/MXene. TEM, HRTEM, and EDS line profile mapping for b–d) Cu2O/MXene and e–g) Cu/MXene. b) and e) TEM images of Cu2O/MXene and Cu/MXene. c) and f) HRTEM for Cu2O/MXene and Cu/MXene. d) and g) EDS line profile mapping Ti, Cu, and O for Cu2O/MXene and Cu/MXene.
Figure 1 a) Schematic illustration of CO2RR with Cu2O/MXene. TEM, HRTEM, and EDS line profile mapping for b–d) Cu2O/MXene and e–g) Cu/MXene. b) and e) TEM images of Cu2O/MXene and Cu/MXene. c) and f) HRTEM for Cu2O/MXene and Cu/MXene. d) and g) EDS line profile mapping Ti, Cu, and O for Cu2O/MXene and Cu/MXene.CC BY · PubMed Central
Figure 2 a) EELS spectra of Cu/MXene and Cu2O/MXene. b) XRD and c) FT‐IR spectra of MXene, Cu/MXene and Cu2O/MXene. d) XANES and e) FT‐EXAFS data for Cu2O/MXene.
Figure 2 a) EELS spectra of Cu/MXene and Cu2O/MXene. b) XRD and c) FT‐IR spectra of MXene, Cu/MXene and Cu2O/MXene. d) XANES and e) FT‐EXAFS data for Cu2O/MXene.CC BY · PubMed Central
Figure 3 XPS spectra of a) C 1s, b) O 1s, and c) Ti 2p of MXene, Cu/MXene and Cu2O/MXene. d) Cu 2p of Cu/MXene and Cu2O/MXene displayed with a magnified view of XPS Cu 2p3/2 comparing with CuNP prepared with hydrothermal process in the presence and absence of NH4OH treatment. e) Cu LMM AES spectra of Cu/MXene and Cu2O/MXene. f) Raman spectra of MXene, Cu/MXene, and Cu2O/MXene.
Figure 3 XPS spectra of a) C 1s, b) O 1s, and c) Ti 2p of MXene, Cu/MXene and Cu2O/MXene. d) Cu 2p of Cu/MXene and Cu2O/MXene displayed with a magnified view of XPS Cu 2p3/2 comparing with CuNP prepared with hydrothermal process in the presence and absence of NH4OH treatment. e) Cu LMM AES spectra of Cu/MXene and Cu2O/MXene. f) Raman spectra of MXene, Cu/MXene, and Cu2O/MXene.CC BY · PubMed Central
Figure 4 Electrochemical tests of Cu2O/MXene. a) LSV curves of Cu/MXene and Cu2O/MXene saturated with CO2 (straight lines) and Ar (dashed lines). Applied potential is corrected with iR compensation, and ECSA is considered for current density. b) Faradaic efficiency on each carbonaceous CO2RR product at −1.3 V versus RHE. Error bars represent the standard deviation in FE calculated after three tests for repeatability. The other non‐carbon product is listed in Table S2 (Supporting Information). c) Relative ratio of the FE with Cu2O/MXene. d) Tafel slope with Cu2O/MXene. The intermediate overpotential region where significant C3 production was detected is highlighted in grey. e) Stability tests of Cu2O/MXene at −1.3 V versus RHE.
Figure 4 Electrochemical tests of Cu2O/MXene. a) LSV curves of Cu/MXene and Cu2O/MXene saturated with CO2 (straight lines) and Ar (dashed lines). Applied potential is corrected with iR compensation, and ECSA is considered for current density. b) Faradaic efficiency on each carbonaceous CO2RR product at −1.3 V versus RHE. Error bars represent the standard deviation in FE calculated after three tests for repeatability. The other non‐carbon product is listed in Table S2 (Supporting Information). c) Relative ratio of the FE with Cu2O/MXene. d) Tafel slope with Cu2O/MXene. The intermediate overpotential region where significant C3 production was detected is highlighted in grey. e) Stability tests of Cu2O/MXene at −1.3 V versus RHE.CC BY · PubMed Central
Figure 5 a) and b) ATR‐FTIR spectra for Cu2O/MXene and Cu2O at varying CO2RR time. c) and d) 1st derivative of ATR‐FTIR spectra for Cu2O/MXene and Cu2O in ranges of 660–710 cm−1. e) FT‐IR spectra of gas species from Cu2O/MXene CO2RR. f) 1H NMR spectra of Cu2O/MXene. All the tests were conducted at −1.3 V versus RHE.
Figure 5 a) and b) ATR‐FTIR spectra for Cu2O/MXene and Cu2O at varying CO2RR time. c) and d) 1st derivative of ATR‐FTIR spectra for Cu2O/MXene and Cu2O in ranges of 660–710 cm−1. e) FT‐IR spectra of gas species from Cu2O/MXene CO2RR. f) 1H NMR spectra of Cu2O/MXene. All the tests were conducted at −1.3 V versus RHE.CC BY · PubMed Central
Figure 6 CO2RR mechanism and calculated free energy diagram (FED) for C3H8(g) production in (a) pure Cu2O(111) structure and b) 0D/2D heterostructure of Cu2O/MXene. c) Correlation between calculated reaction free energies (DG) for *C2 and *C3 formation through sequential processes of additional *CO supply/C‐C coupling in heterostructures of Cu2O/MXene and Cu/MXene and pure Cu2O(111) and Cu(111) surfaces. d) Comparison of lattice parameters of pure Cu2O(111) and Cu(111) compared to MXene structures with respect to compressive or tensile strain. e) Partial density of state (PDOS) of Cu2O/MXene heterostructure and pure Cu2O(111) structure for the d‐band center (εd) of Cu active sites.
Figure 6 CO2RR mechanism and calculated free energy diagram (FED) for C3H8(g) production in (a) pure Cu2O(111) structure and b) 0D/2D heterostructure of Cu2O/MXene. c) Correlation between calculated reaction free energies (DG) for *C2 and *C3 formation through sequential processes of additional *CO supply/C‐C coupling in heterostructures of Cu2O/MXene and Cu/MXene and pure Cu2O(111) and Cu(111) surfaces. d) Comparison of lattice parameters of pure Cu2O(111) and Cu(111) compared to MXene structures with respect to compressive or tensile strain. e) Partial density of state (PDOS) of Cu2O/MXene heterostructure and pure Cu2O(111) structure for the d‐band center (εd) of Cu active sites.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 3

  1. 2023, Climate Change 2022 – Mitigation of Climate Change
  2. Abdelnaby M. M., 2021, Chem. Nano. Mat., 7, 969
  3. Li Z. D., 2021, Energy Environ. Sci., 14, 1696

Cited by

See all 41

Metadata

Authors
Kim, J. Y., Hong, W. T., Phu, T. K. C., Cho, S. C., Kim, B., Baeck, U., Oh, H., Koh, J. H., Yu, X., Choi, C. H., Park, J., Lee, S. U., Chung, C., & Kim, J. K.
Affiliations
  • Sungkyunkwan University (KR)
  • Clean Energy Research Center Korea Institute of Science and Technology (KIST) Hwarang‐ro 14‐gil 5, Seongbuk‐gu Seoul 02792 Republic of Korea
  • Yangzhou University (CN)
  • Pohang University of Science and Technology (KR)
  • Kyung Hee University (KR)
Corresponding author
  • Park, Jongwook
  • Lee, Sang Uck
  • Kim, Jung Kyu
Venue
Advanced Science
Publisher
Wiley
Published
2024-08-19
Volume
11
Issue
39
Pages
e2405154-e2405154
ISSN
2198-3844 (ISSN-L)
OpenAlex
W4401694444
Cited by
41
References
108
Citations by year
2026: 16 · 2025: 22 · 2024: 3
FWCI
2.73
Type
journal article
Language
en
Open access
Locations
  • Advanced Science (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Funders
  • Gyeonggi-do Regional Research Center (GRRCKYUNGHEE2023‐B01)
  • Korea Electric Power Corporation (R23XO04)
  • Ministry of Science and ICT, South Korea (NRF‐2022R1A2C1011559, 2021R1A4A1024129, 2020R1A6A1A03048004)
Topics
  • Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › CO2 Reduction Techniques and Catalysts
  • Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Electrocatalysts for Energy Conversion
  • Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Advanced Photocatalysis Techniques
Keywords
electrochemical CO2 reduction, proton-coupled electron transfer, Cu2O nanoparticles, Ti3C2Tx MXene, Faradaic efficiency, carbon chain elongation, electrocatalysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.