The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Abstract
This review describes microfluidic systems in poly(dimethylsiloxane) (PDMS) for biological studies. Properties of PDMS that make it a suitable platform for miniaturized biological studies, techniques for fabricating PDMS microstructures, and methods for controlling fluid flow in microchannels are discussed. Biological procedures that have been miniaturized into PDMS‐based microdevices include immunoassays, separation of proteins and DNA, sorting and manipulation of cells, studies of cells in microchannels exposed to laminar flows of fluids, and large‐scale, combinatorial screening. The review emphasizes the advantages of miniaturization for biological analysis, such as efficiency of the device and special insights into cell biology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Self-citationMonolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Self-citationFabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Self-citationSoft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
Self-citationPoly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Self-citationMicrofluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Functional hydrogel structures for autonomous flow control inside microfluidic channels
Beebe, D. J., Moore, J. S., Bauer, J. M., Yu, Q., Liu, R. H., Devadoss, C., & Jo, B.-H. (2000) · Nature · doi:10.1038/35007047 · Cited by 1,971
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Micro Total Analysis Systems. 2. Analytical Standard Operations and Applications
Auroux, P.-A., Iossifidis, D., Reyes, D. R., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac020239t · Cited by 1,532
An Integrated Nanoliter DNA Analysis Device
Burns, M. A., Johnson, B. N., Brahmasandra, S. N., Handique, K., Webster, J. R., Krishnan, M., Sammarco, T. S., Man, P. M., Jones, D., Heldsinger, D., et al. (1998) · Science · doi:10.1126/science.282.5388.484 · Cited by 1,299
Passive mixing in a three-dimensional serpentine microchannel
Liu, R. H., Stremler, M. A., Sharp, K. V., Olsen, M. G., Santiago, J. G., Adrian, R. J., Aref, H., & Beebe, D. J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.846699 · Cited by 1,197
From Micro- to Nanofabrication with Soft Materials
Quake, S. R., & Scherer, A. (2000) · Science · doi:10.1126/science.290.5496.1536 · Cited by 1,131
A Microfluidic System for Controlling Reaction Networks in Time
Song, H., Tice, J. D., & Ismagilov, R. F. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390203 · Cited by 1,082
Generation of Solution and Surface Gradients Using Microfluidic Systems
Jeon, N. L., Dertinger, S. K. W., Chiu, D. T., Choi, I. S., Stroock, A. D., & Whitesides, G. M. (2000) · Langmuir · doi:10.1021/la000600b · Cited by 963
Self-citationLi Jeon, N., Baskaran, H., Dertinger, S. K. W., Whitesides, G. M., Van De Water, L., & Toner, M. (2002) · Nature Biotechnology · doi:10.1038/nbt712 · Cited by 917
Self-citationA microfabricated fluorescence-activated cell sorter
Fu, A. Y., Spence, C., Scherer, A., Arnold, F. H., & Quake, S. R. (1999) · Nature Biotechnology · doi:10.1038/15095 · Cited by 878
Generation of Gradients Having Complex Shapes Using Microfluidic Networks
Dertinger, S. K. W., Chiu, D. T., Jeon, N. L., & Whitesides, G. M. (2001) · Analytical Chemistry · doi:10.1021/ac001132d · Cited by 839
Self-citationPatterned Delivery of Immunoglobulins to Surfaces Using Microfluidic Networks
Delamarche, E., Bernard, A., Schmid, H., Michel, B., & Biebuyck, H. (1997) · Science · doi:10.1126/science.276.5313.779 · Cited by 678
Microfabrication Inside Capillaries Using Multiphase Laminar Flow Patterning
Kenis, P. J. A., Ismagilov, R. F., & Whitesides, G. M. (1999) · Science · doi:10.1126/science.285.5424.83 · Cited by 659
Self-citationEffenhauser, C. S., Bruin, G. J. M., Paulus, A., & Ehrat, M. (1997) · Analytical Chemistry · doi:10.1021/ac9703919 · Cited by 640
Components for integrated poly(dimethylsiloxane) microfluidic systems
Ng, J. M. K., Gitlin, I., Stroock, A. D., & Whitesides, G. M. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200210)23:20<3461::aid-elps3461>3.0.co;2-8 · Cited by 626
Self-citationFlexible Methods for Microfluidics
Whitesides, G. M., & Stroock, A. D. (2001) · Physics Today · doi:10.1063/1.1387591 · Cited by 595
Self-citationJohnson, T. J., Ross, D., & Locascio, L. E. (2002) · Analytical Chemistry · doi:10.1021/ac010895d · Cited by 547
Subcellular positioning of small molecules
Takayama, S., Ostuni, E., LeDuc, P., Naruse, K., Ingber, D. E., & Whitesides, G. M. (2001) · Nature · doi:10.1038/35082637 · Cited by 545
Self-citationPatterning cells and their environments using multiple laminar fluid flows in capillary networks
Takayama, S., McDonald, J. C., Ostuni, E., Liang, M. N., Kenis, P. J. A., Ismagilov, R. F., & Whitesides, G. M. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.10.5545 · Cited by 528
Self-citationChiu, D. T., Jeon, N. L., Huang, S., Kane, R. S., Wargo, C. J., Choi, I. S., Ingber, D. E., & Whitesides, G. M. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.040562297 · Cited by 526
Self-citationHansen, C. L., Skordalakes, E., Berger, J. M., & Quake, S. R. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.262485199 · Cited by 517
Grover, W. H., Skelley, A. M., Liu, C. N., Lagally, E. T., & Mathies, R. A. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00468-9 · Cited by 517
An Integrated Microfabricated Cell Sorter
Fu, A. Y., Chou, H.-P., Spence, C., Arnold, F. H., & Quake, S. R. (2002) · Analytical Chemistry · doi:10.1021/ac0255330 · Cited by 510
Microfluidic Diffusion-Based Separation and Detection
Weigl, B. H., & Yager, P. (1999) · Science · doi:10.1126/science.283.5400.346 · Cited by 502
Self-Assembled Magnetic Matrices for DNA Separation Chips
Doyle, P. S., Bibette, J., Bancaud, A., & Viovy, J. (2002) · Science · doi:10.1126/science.1068420 · Cited by 484
Membraneless Vanadium Redox Fuel Cell Using Laminar Flow
Ferrigno, R., Stroock, A. D., Clark, T. D., Mayer, M., & Whitesides, G. M. (2002) · Journal of the American Chemical Society · doi:10.1021/ja020812q · Cited by 481
Self-citationMicrofabricated Centrifugal Microfluidic Systems: Characterization and Multiple Enzymatic Assays
Duffy, D. C., Gillis, H. L., Lin, J., Sheppard, N. F., & Kellogg, G. J. (1999) · Analytical Chemistry · doi:10.1021/ac990682c · Cited by 478
Gradients of substrate-bound laminin orient axonal specification of neurons
Dertinger, S. K. W., Jiang, X., Li, Z., Murthy, V. N., & Whitesides, G. M. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.192457199 · Cited by 446
Self-citationAutonomous Microfluidic Capillary System
Juncker, D., Schmid, H., Drechsler, U., Wolf, H., Wolf, M., Michel, B., de Rooij, N., & Delamarche, E. (2002) · Analytical Chemistry · doi:10.1021/ac0261449 · Cited by 426
A rapid diffusion immunoassay in a T-sensor
Hatch, A., Kamholz, A. E., Hawkins, K. R., Munson, M. S., Schilling, E. A., Weigl, B. H., & Yager, P. (2001) · Nature Biotechnology · doi:10.1038/88135 · Cited by 383
Passively Driven Integrated Microfluidic System for Separation of Motile Sperm
Cho, B. S., Schuster, T. G., Zhu, X., Chang, D., Smith, G. D., & Takayama, S. (2003) · Analytical Chemistry · doi:10.1021/ac020579e · Cited by 356
A sensitive, versatile microfluidic assay for bacterial chemotaxis
Mao, H., Cremer, P. S., & Manson, M. D. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0931258100 · Cited by 332
Microfluidics—downsizing large-scale biology
Mitchell, P. (2001) · Nature Biotechnology · doi:10.1038/90754 · Cited by 264
Chiem, N. H., & Harrison, D. J. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.3.591 · Cited by 264
Chou, H.-P., Unger, M. A., & Quake, S. R. (2001) · Biomedical Microdevices · doi:10.1023/a:1012412916446 · Cited by 223
A Picoliter-Volume Mixer for Microfluidic Analytical Systems
He, B., Burke, B. J., Zhang, X., Zhang, R., & Regnier, F. E. (2001) · Analytical Chemistry · doi:10.1021/ac000850x · Cited by 200
Efficient Mixing and Reactions within Microfluidic Channels Using Microbead-Supported Catalysts
Seong, G. H., & Crooks, R. M. (2002) · Journal of the American Chemical Society · doi:10.1021/ja020932y · Cited by 193
Lateral Propagation of EGF Signaling after Local Stimulation Is Dependent on Receptor Density
Sawano, A., Takayama, S., Matsuda, M., & Miyawaki, A. (2002) · Developmental Cell · doi:10.1016/s1534-5807(02)00224-1 · Cited by 171
Enzyme linked immunosorbent assay on a microchip with electrochemical detection
Rossier, J. S., & Girault, H. H. (2001) · Lab on a Chip · doi:10.1039/b104772h · Cited by 164
Microfluidic technology for assisted reproduction
Beebe, D. J., Wheeler, M. B., Zeringue, H. C., Walters, E. M., & Raty, S. (2002) · Theriogenology · doi:10.1016/s0093-691x(01)00662-8 · Cited by 157
Microscale Bioanalytical Systems
Meldrum, D. R., & Holl, M. R. (2002) · Science · doi:10.1126/science.297.5584.1197 · Cited by 155
A Method for Filling Complex Polymeric Microfluidic Devices and Arrays
Monahan, J., Gewirth, A. A., & Nuzzo, R. G. (2001) · Analytical Chemistry · doi:10.1021/ac001426z · Cited by 138
A Prototype Two-Dimensional Capillary Electrophoresis System Fabricated in Poly(dimethylsiloxane)
Chen, X., Wu, H., Mao, C., & Whitesides, G. M. (2002) · Analytical Chemistry · doi:10.1021/ac0109422 · Cited by 138
Self-citationIntegrated Plastic Microfluidic Devices with ESI-MS for Drug Screening and Residue Analysis
Jiang, Y., Wang, P., Locascio, L. E., & Lee, C. S. (2001) · Analytical Chemistry · doi:10.1021/ac001474j · Cited by 137
SDS capillary gel electrophoresis of proteins in microfabricated channels
Yao, S. Q., Anex, D. S., Caldwell, W. B., Arnold, D. W., Smith, K. B., & Schultz, P. G. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.10.5372 · Cited by 121
Polymer microchips bonded by O2-plasma activation
Wu, Z., Xanthopoulos, N., Reymond, F., et al. (2002) · Electrophoresis · doi:10.1002/1522-2683(200203)23:5<740::aid-elps740>3.0.co;2-7 · Cited by 102
Chan, J. H., Timperman, A. T., Qin, D., et al. (1999) · Analytical Chemistry · doi:10.1021/ac9906678 · Cited by 101
Microfabrication of polydimethylsiloxane electrospray ionization emitters
Kim, J., & Knapp, D. R. (2001) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)00901-3 · Cited by 47
Zhao, B., Moore, J. S., & Beebe, D. J. (2002) · Langmuir · doi:10.1021/la026294e · Cited by 41
Cited by
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Self-citationMicrofluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Microscale technologies for tissue engineering and biology
Khademhosseini, A., Langer, R., Borenstein, J., & Vacanti, J. P. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507681102 · Cited by 1,558
A microfluidic culture platform for CNS axonal injury, regeneration and transport
Taylor, A. M., Blurton-Jones, M., Rhee, S. W., Cribbs, D. H., Cotman, C. W., & Jeon, N. L. (2005) · Nature Methods · doi:10.1038/nmeth777 · Cited by 1,153
Metadata
- Authors
- Sia, S. K., & Whitesides, G. M.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2003-11
- Volume
- 24
- Issue
- 21
- Pages
- 3563-3576
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2124918094
- Cited by
- 1,717
- References
- 56
- FWCI
- 34.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.