Neurotrophin‐eluting hydrogel coatings for neural stimulating electrodes
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Improved sensory and motor prostheses for the central nervous system will require large numbers of electrodes with low electrical thresholds for neural excitation. With the eventual goal of reducing stimulation thresholds, we have investigated the use of biodegradable, neurotrophin‐eluting hydrogels (i.e., poly(ethylene glycol)‐poly(lactic acid), PEGPLA) as a means of attracting neurites to the surface of stimulating electrodes. PEGPLA hydrogels with release rates ranging from 1.5 to 3 weeks were synthesized. These hydrogels were applied to multielectrode arrays with sputtered iridium oxide charge‐injection sites. The coatings had little impact on the iridium oxide electrochemical properties, including charge storage capacity, impedance, and voltage transients during current pulsing. Additionally, we quantitatively examined the ability of neurotrophin‐eluting, PEGPLA hydrogels to promote neurite extension in vitro using a PC12 cell culture model. Hydrogels released neurotrophin (nerve growth factor, NGF) for at least 1 week, with neurite extension near that of an NGF positive control and much higher than extension seen from sham, bovine serum albumin‐releasing boluses, and a negative control. These results show that neurotrophin‐eluting hydrogels can be applied to multielectrode arrays, and suggest a method to improve neuron‐electrode proximity, which could result in lowered electrical stimulation thresholds. Reduced thresholds support the creation of smaller electrode structures and high density electrode prostheses, greatly enhancing prosthesis control and function. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2006
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biological Responses to Materials
Anderson, J. M. (2001) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.31.1.81 · Cited by 1,465
Nerve Growth Factor Signaling, Neuroprotection, and Neural Repair
Sofroniew, M. V., Howe, C. L., & Mobley, W. C. (2001) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.24.1.1217 · Cited by 1,284
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708
Electrical stimulation of neural tissue to evoke behavioral responses
Tehovnik, E. J. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00131-x · Cited by 478
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398
In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
Weiland, J. D., Anderson, D. J., & Humayun, M. S. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805487 · Cited by 382
What blindness can tell us about seeing again: merging neuroplasticity and neuroprostheses
Merabet, L. B., Rizzo, J. F., Amedi, A., Somers, D. C., & Pascual-Leone, A. (2005) · Nature reviews. Neuroscience · doi:10.1038/nrn1586 · Cited by 179
Cogan, S. F., Troyk, P. R., Ehrlich, J., & Plante, T. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851503 · Cited by 162
Self-citationNanoscale neuro-integrative coatings for neural implants
He, W., & Bellamkonda, R. V. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.08.021 · Cited by 156
Kennedy, P. R. (1989) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(89)90142-8 · Cited by 151
Cited by
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Self-citationYuk, H., Lu, B., & Zhao, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00595h · Cited by 2,108
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Liu, J., Qu, S., Suo, Z., & Yang, W. (2021) · National Science Review · doi:10.1093/nsr/nwaa254 · Cited by 483
Approaches to neural tissue engineering using scaffolds for drug delivery
Willerth, S. M., & Sakiyama-Elbert, S. E. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.03.014 · Cited by 392
Park, S., Yuk, H., Zhao, R., Yim, Y. S., Woldeghebriel, E. W., Kang, J., Canales, A., Fink, Y., Choi, G. B., Zhao, X., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-23802-9 · Cited by 312
Organic electrode coatings for next-generation neural interfaces
Aregueta-Robles, U. A., Woolley, A. J., Poole-Warren, L. A., Lovell, N. H., & Green, R. A. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00015 · Cited by 254
Lu, Y., Wang, D., Li, T., Zhao, X., Cao, Y., Yang, H., & Duan, Y. Y. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.04.030 · Cited by 208
“used neurotrophin-eluting hydrogel as coatings for neural stimulating electrodes to promote their biocompatibility [20].”
Kim, D.-H., Wiler, J. A., Anderson, D. J., Kipke, D. R., & Martin, D. C. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.07.034 · Cited by 205
Electrodeposited polypyrrole/carbon nanotubes composite films electrodes for neural interfaces
Lu, Y., Li, T., Zhao, X., Li, M., Cao, Y., Yang, H., & Duan, Y. Y. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.03.022 · Cited by 191
“It has been reported that electrodes implanted in CNS was covered with a highly resistive astroglial encapsulation due to inflammatory responses, resulting in the electrical isolation of the electrodes from the target neurons [8].”
BackgroundCorey, J. M., Gertz, C. C., Wang, B.-S., Birrell, L. K., Johnson, S. L., Martin, D. C., & Feldman, E. L. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.02.020 · Cited by 158
“Instead of using primary neurons harvested from the nervous system, most in vitro testing of biomaterials relies on the use of renewable cell lines [1,2,9–13] or, more rarely, primary cells grown in media supplemented with serum [1,3,14,15].”
MethodSputtered iridium oxide films (SIROFs) for low-impedance neural stimulation and recording electrodes
Cogan, S. F., Plante, T. D., & Ehrlich, J. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1404158 · Cited by 138
Self-citationVisual prosthesis: interfacing stimulating electrodes with retinal neurons to restore vision.
Barriga-Rivera, A., Bareket, L., Goding, J., Aregueta-Robles, U. A., & Suaning, G. J. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00620 · Cited by 73
“Mahoney and Anseth, 2006; Zhou et al., 2016) PVA (Martens et al., 2007; Alves et al., 2012; Lim et al., 2015a) PEG-based (Almany and Seliktar, 2005) PVA-based (Aregueta-Robles et al., 2015; Lim et al., 2015b) Control on degradation rates PEG (Wang et al., 2003; Rice and Anseth, 2004) PVA (Ossipov and Hilborn, 2006; Li…”
InfluentialHara, S. A., Kim, B. J., Kuo, J. T. W., Lee, C. D., Meng, E., & Pikov, V. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066020 · Cited by 57
Material considerations for peripheral nerve interfacing
Kim, Y.-T., & Romero-Ortega, M. I. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.99 · Cited by 47
Modality-Specific Axonal Regeneration: Toward Selective Regenerative Neural Interfaces
Lotfi, P., Garde, K., Chouhan, A. K., Bengali, E., & Romero-Ortega, M. I. (2011) · Frontiers in Neuroengineering · doi:10.3389/fneng.2011.00011 · Cited by 42
Metadata
- Authors
- Winter, J. O., Cogan, S. F., & Rizzo, J. F.
- Venue
- Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Publisher
- Wiley
- Published
- 2006-10-13
- Volume
- 81B
- Issue
- 2
- Pages
- 551-563
- ISSN
- 1552-4973 (ISSN-L)
- 1552-4981
- OpenAlex
- W2005260115
- Cited by
- 98
- References
- 14
- FWCI
- 2.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.