The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Dynamic imaging with lanthanide chelates in normal brain: Contrast due to magnetic susceptibility effects
Abstract
Using a one‐dimensional rapid imaging technique, we have found that injection of lanthanide chelates such as Gd(DTPA)2− leads to a significant decrease (50%) in rat brain signal intensity at 1.45 T using T2‐weighted pulse sequences; however, no effect of comparable size is observed with T 1‐weighted pulse sequences. The transient effect and its kinetics were followed with a temporal resolution of between 1 and 8 s. Experiments with different lanthanide chelates show that the observed decrease in signal intensity correlates with the magnetic moment of each agent but not with their longitudinal relaxivity. Three‐dimensional chemical‐shift resolved experiments demonstrate significant line broadening in brain during infusion with Dy(DTPA)2− Our results show that the cause of this effect is the difference in susceptibility between the capillaries, containing the contrast agent, and the surrounding tissue. As a result of these susceptibility differences, field gradients are produced in the tissue and diffusion of water through these gradients leads to a loss of spin phase coherence and thus a decrease in signal intensity. We propose this as a new type of contrast agent mechanism in NMR. The effect and its kinetics are likely to be related to important physiological parameters such as cerebral blood volume and cerebral blood flow, and do not depend on a breakdown of the blood‐brain barrier as do conventional contrast agent techniques. © 1988 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Hahn, E. L. (1950) · Physical Review · doi:10.1103/physrev.80.580 · Cited by 5,085
Characteristics of gadolinium-DTPA complex: a potential NMR contrast agent
Weinmann, H., Brasch, R., Press, W., & Wesbey, G. (1984) · American Journal of Roentgenology · doi:10.2214/ajr.142.3.619 · Cited by 1,231
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Susceptibility artefacts in NMR imaging
Lüdeke, K. M., Röschmann, P., & Tischler, R. (1985) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(85)90397-2 · Cited by 445
Contrast-enhanced NMR imaging: animal studies using gadolinium-DTPA complex
Brasch, R., Weinmann, H., & Wesbey, G. (1984) · American Journal of Roentgenology · doi:10.2214/ajr.142.3.625 · Cited by 302
Rapid Three-Dimensional MR Imaging Using the FLASH Technique
Frahm, J., Haase, A., & Matthaei, D. (1986) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198603000-00046 · Cited by 267
Interpretation of water nuclear magnetic resonance relaxation times in heterogeneous systems
Glasel, J. A., & Lee, K. H. (1974) · Journal of the American Chemical Society · doi:10.1021/ja00811a003 · Cited by 178
Gadolinium-DTPA as a Contrast Agent in MR Imaging—Theoretical Projections and Practical Observations
Gadian, D., Payne, J. A., Bryant, D. J., et al. (1985) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198503000-00003 · Cited by 156
Contrast in Rapid MR Imaging: T1− and T2-Weighted Imaging
Buxton, R. B., Edelman, R. R., Rosen, B. R., Wismer, G. L., & Brady, T. J. (1987) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198701000-00003 · Cited by 139
Self-citation
Research works printed but not linked: 16
- 10.1148/radiology.144.2.6283594 · doi:10.1148/radiology.144.2.6283594
- 10.1148/radiology.153.1.6433402 · doi:10.1148/radiology.153.1.6433402
- Grossman R. I., 1984, J. Comput. Assist. Tomogr., 8, 204
- Goodstein D. L., 1975, States of Matter
- 10.1016/0022-2364(81)90041-X · doi:10.1016/0022-2364(81)90041-x
- 10.1016/0022-2364(83)90319-0 · doi:10.1016/0022-2364(83)90319-0
- 10.1002/mrm.1910030307 · doi:10.1002/mrm.1910030307
- A.Villringer B. R.Rosen R. B.Lauffer J. L.Ackerman V. J.Wedeen R. B.Buxton andT. J.Brady in “Proceedings of the Fifth Annual Meeting of the Society of Magnetic Resonance in Medicine Montreal Canada August 19‐22 1986 ” Vol. 1.
- Alsaadi B. M., 1980, J. Chem. Soc. Dalton, 2151
- 10.1148/radiology.149.1.6310682 · doi:10.1148/radiology.149.1.6310682
- J. W.Belliveau B. R.Rosen R. B.Buxton K. A.Johnson J. L.Ackerman J. C.Frazer J. B.Moore Y. S.Chao L.Garrido R. B.Lauffer C. R.Fisel andT. J.Brady in “Proceedings of the Sixth Annual Meeting of the Society of Magnetic Resonance in Medicine New York NY August 17‐21 1987.”
- Rapoport S. I., 1976, Blood‐Brain Bamer in Physiology and Medicine
- 10.1111/j.1600-0404.1980.tb03010.x · doi:10.1111/j.1600-0404.1980.tb03010.x
- C. R.Fisel J. L.Ackerman R. B.Buxton andT. J.Brady in “Proceedings of the Sixth Annual Meeting of the Society of Magnetic Resonance in Medicine New York NY August 17‐21 1987.”
- J. W.Belliveau A.Villringer B. R.Rosen R. B.Lauffer J. L.Ackerman R. B.Buxton J.Frazer K.Johnson J.Moore V. J.Wedeen andT. J.Brady in “Proceedings of the Fifth Annual Meeting of the Society of Magnetic Resonance in Medicine Montreal Canada August 19‐22 1986.” [WIP#125]
- Edelman R. R., 1986, AJNR, 7, 751
Cited by
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Functional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Self-citationØstergaard, L., Weisskoff, R. M., Chesler, D. A., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360510 · Cited by 1,512
Self-citationPerfusion imaging with NMR contrast agents
Rosen, B. R., Belliveau, J. W., Vevea, J. M., & Brady, T. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140211 · Cited by 1,151
Self-citationDiffusion-weighted MR Imaging of the Brain
Schaefer, P. W., Grant, P. E., & Gonzalez, R. G. (2000) · Radiology · doi:10.1148/radiology.217.2.r00nv24331 · Cited by 1,052
Molecular imaging in drug discovery and development
Rudin, M., & Weissleder, R. (2003) · Nature Reviews Drug Discovery · doi:10.1038/nrd1007 · Cited by 815
Østergaard, L., Sorensen, A. G., Kwong, K. K., Weisskoff, R. M., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360511 · Cited by 810
Self-citationThe ischemic penumbra: Operationally defined by diffusion and perfusion MRI
Schlaug, G., Benfield, A., Baird, A. E., Siewert, B., Lövblad, K. O., Parker, R. A., Edelman, R. R., & Warach, S. (1999) · Neurology · doi:10.1212/wnl.53.7.1528 · Cited by 663
Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques
Calamante, F., Thomas, D. L., Pell, G. S., Wiersma, J., & Turner, R. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199907000-00001 · Cited by 638
Functional cerebral imaging by susceptibility‐contrast NMR
Belliveau, J. W., Rosen, B. R., Kantor, H. L., Rzedzian, R. R., Kennedy, D. N., McKinstry, R. C., Vevea, J. M., Cohen, M. S., Pykett, I. L., & Brady, T. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140311 · Cited by 570
Self-citationOgawa, S., & Lee, T. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160103 · Cited by 565
Dynamic functional imaging of relative cerebral blood volume during rat forepaw stimulation
Mandeville, J. B., Marota, J. J. A., Kosofsky, B. E., Keltner, J. R., Weissleder, R., Rosen, B. R., & Weisskoff, R. M. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390415 · Cited by 549
Self-citationCha, S., Knopp, E. A., Johnson, G., Wetzel, S. G., Litt, A. W., & Zagzag, D. (2002) · Radiology · doi:10.1148/radiol.2231010594 · Cited by 525
Weinstein, J. S., Varallyay, C. G., Dosa, E., Gahramanov, S., Hamilton, B., Rooney, W. D., Muldoon, L. L., & Neuwelt, E. A. (2010) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2009.192 · Cited by 500
Sugahara, T., Korogi, Y., Kochi, M., Ikushima, I., Hirai, T., Okuda, T., Shigematsu, Y., Liang, L., Ge, Y., Ushio, Y., et al. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.171.6.9843274 · Cited by 460
Calamante, F., Gadian, D. G., & Connelly, A. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200009)44:3<466::aid-mrm18>3.0.co;2-m · Cited by 458
Classic models for dynamic contrast‐enhanced MRI
Sourbron, S. P., & Buckley, D. L. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2940 · Cited by 434
25 Years of Contrast-Enhanced MRI: Developments, Current Challenges and Future Perspectives
Lohrke, J., Frenzel, T., Endrikat, J., Alves, F. C., Grist, T. M., Law, M., Lee, J. M., Leiner, T., Li, K.-C., Nikolaou, K., et al. (2016) · Advances in Therapy · doi:10.1007/s12325-015-0275-4 · Cited by 420
Provenzale, J. M., Mukundan, S., & Barboriak, D. P. (2006) · Radiology · doi:10.1148/radiol.2393042031 · Cited by 402
Fantini, S., Sassaroli, A., Tgavalekos, K. T., & Kornbluth, J. (2016) · Neurophotonics · doi:10.1117/1.nph.3.3.031411 · Cited by 397
Chu, K. ‐. C., Xu, Y., Balschi, J. A., & Springer, C. S. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130207 · Cited by 373
Perfusion‐weighted imaging defects during spontaneous migrainous aura
Cutrer, F. M., Sorensen, A. G., Weisskoff, R. M., Østergaard, L., Del Rio, M. S., Lee, E. J., Rosen, B. R., & Moskowitz, M. A. (1998) · Annals of Neurology · doi:10.1002/ana.410430108 · Cited by 372
Self-citationPerfusion MRI: The Five Most Frequently Asked Technical Questions
Essig, M., Shiroishi, M. S., Nguyen, T. B., Saake, M., Provenzale, J. M., Enterline, D., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9543 · Cited by 366
Fisel, C. R., Ackerman, J. L., Buxton, R. B., Garrido, L., Belliveau, J. W., Rosen, B. R., & Brady, T. J. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170206 · Cited by 356
Self-citationPerfusion MRI: The Five Most Frequently Asked Clinical Questions
Essig, M., Nguyen, T. B., Shiroishi, M. S., Saake, M., Provenzale, J. M., Enterline, D. S., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9544 · Cited by 344
The physics of functional magnetic resonance imaging (fMRI)
Buxton, R. B. (2013) · Reports on Progress in Physics · doi:10.1088/0034-4885/76/9/096601 · Cited by 341
Self-citationNMR imaging of changes in vascular morphology due to tumor angiogenesis
Dennie, J., Mandeville, J. B., Boxerman, J. L., Packard, S. D., Rosen, B. R., & Weisskoff, R. M. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400602 · Cited by 337
Self-citationPerfusion and vascular permeability: Basic concepts and measurement in DCE-CT and DCE-MRI
Cuenod, C. A., & Balvay, D. (2013) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2013.10.010 · Cited by 312
Contrast agents and cerebral hemodynamics
Rosen, B. R., Belliveau, J. W., Buchbinder, B. R., McKinstry, R. C., Porkka, L. M., Kennedy, D. N., Neuder, M. S., Fisel, C. R., Aronen, H. J., Kwong, K. K., et al. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910190216 · Cited by 290
Self-citationPrinciples of cerebral perfusion imaging by bolus tracking
Østergaard, L. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20460 · Cited by 289
PET/MRI for Neurologic Applications
Catana, C., Drzezga, A., Heiss, W.-D., & Rosen, B. R. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.105346 · Cited by 288
Self-citationA brief history of human brain mapping
Raichle, M. E. (2009) · Trends in Neurosciences · doi:10.1016/j.tins.2008.11.001 · Cited by 286
Yang, H., Zhuang, Y., Sun, Y., Dai, A., Shi, X., Wu, D., Li, F., Hu, H., & Yang, S. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.03.018 · Cited by 278
Sourbron, S., Ingrisch, M., Siefert, A., Reiser, M., & Herrmann, K. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22005 · Cited by 276
Normal diffusion-weighted MRI during stroke-like deficits
Ay, H., Buonanno, F. S., Rordorf, G., Schaefer, P. W., Schwamm, L. H., Wu, O., Gonzalez, R. G., Yamada, K., Sorensen, G. A., & Koroshetz, W. J. (1999) · Neurology · doi:10.1212/wnl.52.9.1784 · Cited by 271
Chen, Y. C. I., Galpern, W. R., Brownell, A., Matthews, R. T., Bogdanov, M., Isacson, O., Keltner, J. R., Beal, M. F., Rosen, B. R., & Jenkins, B. G. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380306 · Cited by 257
Self-citationEllingson, B. M. (2015) · Current Neurology and Neuroscience Reports · doi:10.1007/s11910-014-0506-0 · Cited by 132
Duyn, J. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2012.11.013 · Cited by 95
“Tracking of the bolus passage through the vasculature using dynamic MRI (with either T 2 or T2 weighting), allows one to analyze vascular characteristics and estimate cerebral blood flow and volume [4].”
BackgroundMethodImaging of cerebrovascular pathology in animal models of Alzheimer's disease
Klohs, J., Rudin, M., Shimshek, D. R., & Beckmann, N. (2014) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2014.00032 · Cited by 82
Hussein, R., Shin, D., Zhao, M. Y., Guo, J., Davidzon, G., Steinberg, G., Moseley, M., & Zaharchuk, G. (2024) · Medical Image Analysis · doi:10.1016/j.media.2023.103072 · Cited by 9
Metadata
- Authors
- Villringer, A., Rosen, B. R., Belliveau, J. W., Ackerman, J. L., Lauffer, R. B., Buxton, R. B., Chao, Y., Wedeenand, V. J., & Brady, T. J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1988-02
- Volume
- 6
- Issue
- 2
- Pages
- 164-174
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2017009049
- Cited by
- 706
- References
- 14
- FWCI
- 14.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.