The DOI matches its Crossref record; 77 of the 77 references it cites were found in a registry or an index.
Classic models for dynamic contrast‐enhanced MRI
Abstract
Dynamic contrast‐enhanced MRI (DCE‐MRI) is a functional MRI method where T1 ‐weighted MR images are acquired dynamically after bolus injection of a contrast agent. The data can be interpreted in terms of physiological tissue characteristics by applying the principles of tracer‐kinetic modelling. In the brain, DCE‐MRI enables measurement of cerebral blood flow (CBF), cerebral blood volume (CBV), blood–brain barrier (BBB) permeability–surface area product (PS) and the volume of the interstitium (ve). These parameters can be combined to form others such as the volume‐transfer constant Ktrans, the extraction fraction E and the contrast‐agent mean transit times through the intra‐ and extravascular spaces. A first generation of tracer‐kinetic models for DCE‐MRI was developed in the early 1990s and has become a standard in many applications. Subsequent improvements in DCE‐MRI data quality have driven the development of a second generation of more complex models. They are increasingly used, but it is not always clear how they relate to the models of the first generation or to the model‐free deconvolution methods for tissues with intact BBB. This lack of understanding is leading to increasing confusion on when to use which model and how to interpret the parameters. The purpose of this review is to clarify the relation between models of the first and second generations and between model‐based and model‐free methods. All quantities are defined using a generic terminology to ensure the widest possible scope and to reveal the link between applications in the brain and in other organs. Copyright © 2013 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Textbook of Medical Physiology
(1966) · Annals of Internal Medicine · doi:10.7326/0003-4819-64-6-1363_2 · Cited by 9,749
Tofts, P. S., Brix, G., Buckley, D. L., Evelhoch, J. L., Henderson, E., Knopp, M. V., Larsson, H. B. W., Lee, T.-Y., Mayr, N. A., Parker, G. J. M., et al. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199909)10:3<223::aid-jmri2>3.0.co;2-s · Cited by 3,143
Self-citationRohrer, M., Bauer, H., Mintorovitch, J., Requardt, M., & Weinmann, H.-J. (2005) · Investigative Radiology · doi:10.1097/01.rli.0000184756.66360.d3 · Cited by 1,682
Modeling tracer kinetics in dynamic Gd‐DTPA MR imaging
Tofts, P. S. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070113 · Cited by 1,478
Tofts, P. S., & Kermode, A. G. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170208 · Cited by 1,456
Textbook of Medical Physiology
Iatridis, P. G. (1991) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1991.03470200123049 · Cited by 1,275
Perfusion imaging with NMR contrast agents
Rosen, B. R., Belliveau, J. W., Vevea, J. M., & Brady, T. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140211 · Cited by 1,151
Compartmental analysis in Biology and Medicine
Anderson, D. H. (1986) · Mathematical Biosciences · doi:10.1016/0025-5564(86)90168-9 · Cited by 988
Compartmental analysis in biology and medicine
Jacquez, J. A. (1985) · Cited by 965
Østergaard, L., Sorensen, A. G., Kwong, K. K., Weisskoff, R. M., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360511 · Cited by 810
Transport of potassium-42 from blood to tissue in isolated mammalian skeletal muscles
Renkin, E. M. (1959) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1959.197.6.1205 · Cited by 723
Villringer, A., Rosen, B. R., Belliveau, J. W., Ackerman, J. L., Lauffer, R. B., Buxton, R. B., Chao, Y., Wedeenand, V. J., & Brady, T. J. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910060205 · Cited by 706
Boxerman, J. L., Schmainda, K. M., & Weisskoff, R. M. (2006) · PubMed · Cited by 686
Pharmacokinetic Parameters in CNS Gd-DTPA Enhanced MR Imaging
Brix, G., Semmler, W., Port, R., Schad, L. R., Layer, G., & Lorenz, W. J. (1991) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199107000-00018 · Cited by 659
Rempp, K. A., Brix, G., Wenz, F., Becker, C. R., Gückel, F., & Lorenz, W. J. (1994) · Radiology · doi:10.1148/radiology.193.3.7972800 · Cited by 639
Wu, O., Østergaard, L., Weisskoff, R. M., Benner, T., Rosen, B. R., & Sorensen, A. G. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10522 · Cited by 604
Leach, M. O., Brindle, K. M., Evelhoch, J. L., Griffiths, J. R., Horsman, M. R., Jackson, A., Jayson, G. C., Judson, I. R., Knopp, M. V., Maxwell, R. J., et al. (2005) · British Journal of Cancer · doi:10.1038/sj.bjc.6602550 · Cited by 513
Tracer kinetic methods in medical physiology
Lassen, N. A., & Perl, W. (1979) · Raven Press eBooks · Cited by 495
DCE-MRI biomarkers in the clinical evaluation of antiangiogenic and vascular disrupting agents
O'Connor, J. P. B., Jackson, A., Parker, G. J. M., & Jayson, G. C. (2007) · British Journal of Cancer · doi:10.1038/sj.bjc.6603515 · Cited by 484
Calamante, F., Gadian, D. G., & Connelly, A. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200009)44:3<466::aid-mrm18>3.0.co;2-m · Cited by 458
Functional tumor imaging with dynamic contrast‐enhanced magnetic resonance imaging
Choyke, P. L., Dwyer, A. J., & Knopp, M. V. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10304 · Cited by 439
Larsson, H. B. W., Stubgaard, M., Frederiksen, J. L., Jensen, M., Henriksen, O., & Paulson, O. B. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160111 · Cited by 431
Roberts, H. C., Roberts, T. P. L., Brasch, R. C., & Dillon, W. P. (2000) · PubMed Central · Cited by 427
Zierler, K. L. (1961) · Journal of Clinical Investigation · doi:10.1172/jci104437 · Cited by 401
Pintaske, J., Martirosian, P., Graf, H., Erb, G., Lodemann, K.-P., Claussen, C. D., & Schick, F. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000197668.44926.f7 · Cited by 383
On the scope and interpretation of the Tofts models for DCE‐MRI
Sourbron, S. P., & Buckley, D. L. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22861 · Cited by 371
Self-citationTracer kinetic modelling in MRI: estimating perfusion and capillary permeability
Sourbron, S. P., & Buckley, D. L. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/2/r1 · Cited by 361
Self-citationStudies of Gd‐DTPA relaxivity and proton exchange rates in tissue
Donahue, K. M., Burstein, D., Manning, W. J., & Gray, M. L. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320110 · Cited by 339
Jackson, A., O'Connor, J. P. B., Parker, G. J. M., & Jayson, G. C. (2007) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-07-0238 · Cited by 299
Perfusion Imaging of the Liver: Current Challenges and Future Goals
Pandharipande, P. V., Krinsky, G. A., Rusinek, H., & Lee, V. S. (2005) · Radiology · doi:10.1148/radiol.2343031362 · Cited by 294
Sourbron, S., Ingrisch, M., Siefert, A., Reiser, M., & Herrmann, K. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22005 · Cited by 276
Self-citationMyocardial blood flow quantification with MRI by model‐independent deconvolution
Jerosch‐Herold, M., Swingen, C., & Seethamraju, R. T. (2002) · Medical Physics · doi:10.1118/1.1473135 · Cited by 268
Brix, G., Kiessling, F., Lucht, R., Darai, S., Wasser, K., Delorme, S., & Griebel, J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20161 · Cited by 252
A model for capillary exchange
Johnson, J., & Wilson, T. (1966) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1966.210.6.1299 · Cited by 248
Assessment of hepatic perfusion parameters with dynamic MRI
Materne, R., Smith, A. M., Peeters, F., Dehoux, J. P., Keyeux, A., Horsmans, Y., & Van Beers, B. E. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10045 · Cited by 226
Larsson, H. B. W., Courivaud, F., Rostrup, E., & Hansen, A. E. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22136 · Cited by 224
Schabel, M. C., & Parker, D. L. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/9/010 · Cited by 221
Dynamic Magnetic Resonance Perfusion Imaging of Brain Tumors
Covarrubias, D. J., Rosen, B. R., & Lev, M. H. (2004) · The Oncologist · doi:10.1634/theoncologist.9-5-528 · Cited by 213
Analysis of myocardial perfusion MRI
Jerosch‐Herold, M., Seethamraju, R. T., Swingen, C. M., Wilke, N. M., & Stillman, A. E. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20065 · Cited by 198
Brix, G., Bahner, M. L., Hoffmann, U., Horváth, A., & Schreiber, W. (1999) · Radiology · doi:10.1148/radiology.210.1.r99ja46269 · Cited by 186
Ewing, J. R., Knight, R. A., Nagaraja, T. N., Yee, J. S., Nagesh, V., Whitton, P. A., Li, L., & Fenstermacher, J. D. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10524 · Cited by 181
Wirestam, R., Knutsson, L., Østergaard, L., Bolling, M., Aunola, J.-P., Lindgren, A. G., Geijer, B., Holt�s, S., & St�hlberg, F. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200005)43:5<691::aid-mrm11>3.0.co;2-b · Cited by 165
Calamante, F., Gadian, D. G., & Connelly, A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10643 · Cited by 147
Measuring blood volume and vascular transfer constant from dynamic, T‐weighted contrast‐enhanced MRI
Johnson, G., Wetzel, S. G., Cha, S., Babb, J. S., & Tofts, P. S. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20049 · Cited by 145
Buckley, D. L., Shurrab, A. E., Cheung, C. M., Jones, A. P., Mamtora, H., & Kalra, P. A. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20699 · Cited by 134
Self-citationEwing, J. R., Brown, S. L., Lü, M., Panda, S., Ding, G., Knight, R. A., Cao, Y., Jiang, Q., Nagaraja, T. N., Churchman, J. L., et al. (2005) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600189 · Cited by 130
Ingrisch, M., Sourbron, S., Morhard, D., Ertl-Wagner, B., Kümpfel, T., Hohlfeld, R., Reiser, M., & Glaser, C. (2012) · Investigative Radiology · doi:10.1097/rli.0b013e31823bfc97 · Cited by 106
Self-citationQuantitative imaging biomarkers in neuro-oncology
Waldman, A. D., Jackson, A., Price, S. J., Clark, C. A., Booth, T. C., Auer, D. P., Tofts, P. S., Collins, D. J., Leach, M. O., & Rees, J. H. (2009) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2009.92 · Cited by 104
Compartmental Analysis in Biology and Medicine, 2nd edition.
Faddy, M. J., & Jacquez, J. A. (1987) · Biometrics · doi:10.2307/2531562 · Cited by 104
Prediction of hemorrhage in acute ischemic stroke using permeability MR imaging.
Kassner, A., Roberts, T. P. L., Taylor, K. S., Silver, F. L., & Mikulis, D. J. (2005) · PubMed Central · Cited by 102
Kershaw, L. E., & Buckley, D. L. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21040 · Cited by 96
Self-citationSingh, A. K., Haris, M., Rathore, D., Purwar, A., Sarma, M. K., Bayu, G., Husain, N., Rathore, R. K. S., & Gupta, R. K. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21080 · Cited by 95
Larsson, H., Hansen, A. E., Berg, H., Rostrup, E., & Haraldseth, O. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21328 · Cited by 84
Quantification of renal perfusion and function on a voxel‐by‐voxel basis: A feasibility study
Dujardin, M., Sourbron, S. P., Luypaert, R., Verbeelen, D. L., & Stadnik, T. W. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20608 · Cited by 79
Self-citationBrix, G., Zwick, S., Kiessling, F. M., & Griebel, J. (2009) · Medical Physics · doi:10.1118/1.3147145 · Cited by 78
Donaldson, S. B., Betts, G. N. J., Bonington, S. C., Homer, J. J., Slevin, N. J., Kershaw, L. E., Valentine, H. R., West, C., & Buckley, D. L. (2011) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2010.09.039 · Cited by 77
Self-citationRoberts, C., Little, R. A., Watson, Y., Zhao, S., Buckley, D. L., & Parker, G. J. M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22593 · Cited by 70
Self-citationHaroon, H. A., Buckley, D. L., Patankar, T. F., Dow, G. R., Rutherford, S. A., Balériaux, D., & Jackson, A. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20045 · Cited by 68
Self-citationNon-invasive assessment of vessel morphology and function in tumors by magnetic resonance imaging
Kiessling, F. M., Jugold, M., Woenne, E. C., & Brix, G. (2007) · European Radiology · doi:10.1007/s00330-006-0566-x · Cited by 67
Makkat, S., Luypaert, R., Stadnik, T. W., et al. (2008) · Radiology · doi:10.1148/radiol.2492071147 · Cited by 65
Donaldson, S. B., Buckley, D. L., O’Connor, J. P. B., Davidson, S. E., Carrington, B. M., Jones, A. P., & West, C. (2009) · British Journal of Cancer · doi:10.1038/sj.bjc.6605415 · Cited by 60
Self-citationKershaw, L. E., Hutchinson, C. E., & Buckley, D. L. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21674 · Cited by 56
Self-citationHackländer, T., Reichenbach, J. R., Hofer, M., & Mödder, U. (1996) · PubMed · Cited by 56
Peeters, F., Annet, L., Hermoye, L., & BEERS, B. E. V. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20032 · Cited by 55
Dean, B. L., Lee, C., KIRSCH, J. E., Runge, V. M., Dempsey, R., & Pettigrew, L. C. (1992) · PubMed · Cited by 52
de BAZELAIRE, C., Siauve, N., Fournier, L. S., Frouin, F., Robert, P., Clémеnt, O., de Kerviler, É., & Cuénod, C. A. (2005) · European Radiology · doi:10.1007/s00330-005-2873-z · Cited by 50
Hackländer, T., Reichenbach, J. R., & Mödder, U. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199711000-00003 · Cited by 48
Garpebring, A., Wirestam, R., Östlund, N., & Karlsson, M. C. F. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22760 · Cited by 46
Validity of perfusion parameters obtained using the modified Tofts model: A simulation study
Luypaert, R., Sourbron, S. P., & Mey, J. D. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22728 · Cited by 45
Self-citationHackländer, T., Hofer, M., Reichenbach, J. R., Rascher, K., Fürst, G., & Mödder, U. (1996) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199607000-00006 · Cited by 45
Bolus‐tracking MRI with a simultaneous T1‐ and T‐measurement
Sourbron, S. P., Heilmann, M., Biffar, A., Walczak, C., Vautier, J., Volk, A., & Peller, M. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22042 · Cited by 42
Self-citationDynamic contrast-enhanced MR imaging to assess physiologic variations of myometrial perfusion
Thomassin‐Naggara, I., Balvay, D., Cuénod, C. A., Daraï, É., Marsault, C., & Bazot, M. (2009) · European Radiology · doi:10.1007/s00330-009-1621-1 · Cited by 41
Choice of the regularization parameter for perfusion quantification with MRI
Sourbron, S. P., Luypaert, R., Schuerbeek, P. V., Dujardin, M., & Stadnik, T. W. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/14/020 · Cited by 39
Self-citationHaroon, H. A., Patankar, T. F., Zhu, X., Li, K., Thacker, N. A., Scott, M. L. J., & Jackson, A. (2007) · British Journal of Radiology · doi:10.1259/bjr/17112059 · Cited by 33
Moody, A. R., Martel, A. L., Kenton, A., ALLDER, S., Horsfield, M. A., Delay, G. S., & Morgan, P. S. (2000) · Investigative Radiology · doi:10.1097/00004424-200007000-00002 · Cited by 32
Michoux, N., Huwart, L., Abarca‐Quinones, J., Dorvillius, M., Annet, L., Peeters, F., & BEERS, B. E. V. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21524 · Cited by 27
Perfusion MR Imaging: Moving Forward
Sorensen, A. G. (2008) · Radiology · doi:10.1148/radiol.2492081429 · Cited by 21
Cited by
An overview of deep learning in medical imaging focusing on MRI
Lundervold, A. S., & Lundervold, A. (2019) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2018.11.002 · Cited by 2,058
Neuroinflammation, Stroke, Blood-Brain Barrier Dysfunction, and Imaging Modalities
Candelario-Jalil, E., Dijkhuizen, R. M., & Magnus, T. (2022) · Stroke · doi:10.1161/strokeaha.122.036946 · Cited by 953
Functional morphology of the blood–brain barrier in health and disease
Liebner, S., Dijkhuizen, R. M., Reiss, Y., Plate, K. H., Agalliu, D., & Constantin, G. (2018) · Acta Neuropathologica · doi:10.1007/s00401-018-1815-1 · Cited by 872
Heye, A. K., Culling, R. D., Valdés Hernández, M. D. C., Thrippleton, M. J., & Wardlaw, J. M. (2014) · NeuroImage: Clinical · doi:10.1016/j.nicl.2014.09.002 · Cited by 406
Models and methods for analyzing DCE‐MRI: A review
Khalifa, F., Soliman, A., El‐Baz, A., Abou El‐Ghar, M., El‐Diasty, T., Gimel'farb, G., Ouseph, R., & Dwyer, A. C. (2014) · Medical Physics · doi:10.1118/1.4898202 · Cited by 322
Metadata
- Authors
- Sourbron, S. P., & Buckley, D. L.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2013-05-15
- Volume
- 26
- Issue
- 8
- Pages
- 1004-1027
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2101482993
- Cited by
- 434
- References
- 77
- FWCI
- 20.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.