The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Applications of a travelling wave‐based radio‐frequency‐only stacked ring ion guide
Abstract
The use of radio‐frequency (RF)‐only ion guides for efficient transport of ions through regions of a mass spectrometer where the background gas pressure is relatively high is widespread in present instrumentation. Whilst multiple collisions between ions and the background gas can be beneficial, for example in inducing fragmentation and/or decreasing the spread in ion energies, the resultant reduction of ion axial velocity can be detrimental in modes of operation where a rapidly changing influx of ions to the gas‐filled ion guide needs to be reproduced at the exit. In general, the RF‐only ion guides presently in use are based on multipole rod sets. Here we report investigations into a new mode of ion propulsion within an RF ion guide based on a stack of ring electrodes. Ion propulsion is produced by superimposing a voltage pulse on the confining RF of an electrode and then moving the pulse to an adjacent electrode and so on along the guide to provide a travelling voltage wave on which the ions can surf. Through appropriate choice of the travelling wave pulse height, velocity and gas pressure it will be shown that the stacked ring ion guide with the travelling wave is effective as a collision cell in a tandem mass spectrometer where fast mass scanning or switching is required, as an ion mobility separator at pressures around 0.2 mbar, as an ion delivery device for enhancement of duty cycle on an orthogonal acceleration time‐of‐flight (oa‐TOF) mass analyser, and as an ion fragmentation device at higher wave velocities. Copyright © 2004 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The mobility and diffusion of ions in gases
McDaniel, E. W., & Mason, E. A. (1973) · CERN Document Server (European Organization for Nuclear Research) · Cited by 942
Radiofrequency Spectroscopy of Stored Ions I: Storage
Dehmelt, H. G. (1968) · Advances in Atomic and Molecular Physics · doi:10.1016/s0065-2199(08)60170-0 · Cited by 765
Recent improvements in and analytical applications of advanced ion trap technology
Stafford, G. C., Kelley, P. E., Syka, J. E. P., Reynolds, W. E., & Todd, J. F. J. (1984) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(84)80077-4 · Cited by 561
Quadrupole storage mass spectrometry
March, R. E., Hughes, R. J., & Roberts, A. D. (1991) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)82582-9 · Cited by 535
State-Selected and State-to-State Ion−Molecule Reaction Dynamics
Ng, C.-Y. (2002) · The Journal of Physical Chemistry A · doi:10.1021/jp020055i · Cited by 429
Capillary zone electrophoresis-mass spectrometry using an electrospray ionization interface
Smith, R. D., Olivares, J. A., Nguyen, N. T., & Udseth, H. R. (1988) · Analytical Chemistry · doi:10.1021/ac00156a013 · Cited by 393
Shaffer, S. A., Prior, D. C., Anderson, G. A., Udseth, H. R., & Smith, R. D. (1998) · Analytical Chemistry · doi:10.1021/ac9802170 · Cited by 262
Schaffer, S. A., Tang, K., Anderson, G. A., Prior, D. C., Udseth, H. R., & Smith, R. D. (1997) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19971030)11:16<1813::aid-rcm87>3.0.co;2-d · Cited by 262
Design and Implementation of a New Electrodynamic Ion Funnel
Kim, T., Tolmachev, A. V., Harkewicz, R., Prior, D. C., Anderson, G., Udseth, H. R., Smith, R. D., Bailey, T. H., Rakov, S., & Futrell, J. H. (2000) · Analytical Chemistry · doi:10.1021/ac991412x · Cited by 201
Collisional damping interface for an electrospray ionization time-of-flight mass spectrometer
Krutchinsky, A. N., Chernushevich, I. V., Spicer, V. L., Ens, W., & Standing, K. G. (1998) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(98)00027-0 · Cited by 187
Cited by
Ion mobility–mass spectrometry
Kanu, A. B., Dwivedi, P., Tam, M., Matz, L., & Hill, H. H. (2008) · Journal of Mass Spectrometry · doi:10.1002/jms.1383 · Cited by 1,154
Ion mobility–mass spectrometry analysis of large protein complexes
Ruotolo, B. T., Benesch, J. L. P., Sandercock, A. M., Hyung, S.-J., & Robinson, C. V. (2008) · Nature Protocols · doi:10.1038/nprot.2008.78 · Cited by 1,092
Lanucara, F., Holman, S. W., Gray, C. J., & Eyers, C. E. (2014) · Nature Chemistry · doi:10.1038/nchem.1889 · Cited by 901
Pringle, S. D., Giles, K., Wildgoose, J. L., Williams, J. P., Slade, S. E., Thalassinos, K., Bateman, R. H., Bowers, M. T., & Scrivens, J. H. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.07.021 · Cited by 808
Self-citationBush, M. F., Hall, Z., Giles, K., Hoyes, J., Robinson, C. V., & Ruotolo, B. T. (2010) · Analytical Chemistry · doi:10.1021/ac1022953 · Cited by 796
Self-citationEvidence for Macromolecular Protein Rings in the Absence of Bulk Water
Ruotolo, B. T., Giles, K., Campuzano, I., Sandercock, A. M., Bateman, R. H., & Robinson, C. V. (2005) · Science · doi:10.1126/science.1120177 · Cited by 596
Self-citationLeung, Y. H., Ng, A. M. C., Xu, X., Shen, Z., Gethings, L. A., Wong, M. T., Chan, C. M. N., Guo, M. Y., Ng, Y. H., Djurišić, A. B., et al. (2014) · Small · doi:10.1002/smll.201302434 · Cited by 566
Fundamentals of Traveling Wave Ion Mobility Spectrometry
Shvartsburg, A. A., & Smith, R. D. (2008) · Analytical Chemistry · doi:10.1021/ac8016295 · Cited by 534
A Cyclic Ion Mobility-Mass Spectrometry System
Giles, K., Ujma, J., Wildgoose, J., Pringle, S., Richardson, K., Langridge, D., & Green, M. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01838 · Cited by 510
Self-citationRecommendations for reporting ion mobility Mass Spectrometry measurements
Gabelica, V., Shvartsburg, A. A., Afonso, C., Barran, P., Benesch, J. L. P., Bleiholder, C., Bowers, M. T., Bilbao, A., Bush, M. F., Campbell, J. L., et al. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21585 · Cited by 493
Self-citationBiomolecule Analysis by Ion Mobility Spectrometry
Bohrer, B. C., Merenbloom, S. I., Koeniger, S. L., Hilderbrand, A. E., & Clemmer, D. E. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.113001 · Cited by 492
Drift time-specific collision energies enable deep-coverage data-independent acquisition proteomics
Distler, U., Kuharev, J., Navarro, P., Levin, Y., Schild, H., & Tenzer, S. (2014) · Nature Methods · doi:10.1038/nmeth.2767 · Cited by 481
Ion mobility mass spectrometry of proteins and proteinassemblies
Uetrecht, C., Rose, R. J., van Duijn, E., Lorenzen, K., & Heck, A. J. R. (2010) · Chem. Soc. Rev. · doi:10.1039/b914002f · Cited by 462
Review on ion mobility spectrometry. Part 1: current instrumentation
Cumeras, R., Figueras, E., Davis, C. E., Baumbach, J. I., & Gràcia, I. (2015) · The Analyst · doi:10.1039/c4an01100g · Cited by 459
Fundamentals of ion mobility spectrometry
Gabelica, V., & Marklund, E. (2018) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2017.10.022 · Cited by 440
Ion Mobility-Mass Spectrometry: Time-Dispersive Instrumentation
May, J. C., & McLean, J. A. (2015) · Analytical Chemistry · doi:10.1021/ac504720m · Cited by 435
Vibrational spectroscopy of bare and solvated ionic complexes of biological relevance
Polfer, N. C., & Oomens, J. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20215 · Cited by 415
Protein Complexes in the Gas Phase: Technology for Structural Genomics and Proteomics
Benesch, J. L. P., Ruotolo, B. T., Simmons, D. A., & Robinson, C. V. (2007) · Chemical Reviews · doi:10.1021/cr068289b · Cited by 408
May, J. C., Goodwin, C. R., Lareau, N. M., Leaptrot, K. L., Morris, C. B., Kurulugama, R. T., Mordehai, A., Klein, C., Barry, W., Darland, E., et al. (2014) · Analytical Chemistry · doi:10.1021/ac4038448 · Cited by 401
Campuzano, I., Bush, M. F., Robinson, C. V., Beaumont, C., Richardson, K., Kim, H., & Kim, H. I. (2012) · Analytical Chemistry · doi:10.1021/ac202625t · Cited by 383
Fundamentals of Trapped Ion Mobility Spectrometry
Michelmann, K., Silveira, J. A., Ridgeway, M. E., & Park, M. A. (2015) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-014-0999-4 · Cited by 374
Enhancements in travelling wave ion mobility resolution
Giles, K., Williams, J. P., & Campuzano, I. (2011) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.5013 · Cited by 369
Self-citationThe Role of Mass Spectrometry in Structure Elucidation of Dynamic Protein Complexes
Sharon, M., & Robinson, C. V. (2007) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.76.061005.090816 · Cited by 357
Smith, D. P., Knapman, T. W., Campuzano, I., Malham, R. W., Berryman, J. T., Radford, S. E., & Ashcroft, A. E. (2009) · European Journal of Mass Spectrometry · doi:10.1255/ejms.947 · Cited by 334
Ion Mobility Mass Spectrometry of Peptide Ions: Effects of Drift Gas and Calibration Strategies
Bush, M. F., Campuzano, I. D. G., & Robinson, C. V. (2012) · Analytical Chemistry · doi:10.1021/ac3014498 · Cited by 315
High-sensitivity Analytical Approaches for the Structural Characterization of Glycoproteins
Alley, W. R., Mann, B. F., & Novotny, M. V. (2013) · Chemical Reviews · doi:10.1021/cr3003714 · Cited by 310
Trapped ion mobility spectrometry: A short review
Ridgeway, M. E., Lubeck, M., Jordens, J., Mann, M., & Park, M. A. (2018) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2018.01.006 · Cited by 308
Young, L. M., Saunders, J. C., Mahood, R. A., Revill, C. H., Foster, R. J., Tu, L.-H., Raleigh, D. P., Radford, S. E., & Ashcroft, A. E. (2015) · Nature Chemistry · doi:10.1038/nchem.2129 · Cited by 281
Differential hydrogen/deuterium exchange mass spectrometry analysis of protein–ligand interactions
Chalmers, M. J., Busby, S. A., Pascal, B. D., West, G. M., & Griffin, P. R. (2011) · Expert Review of Proteomics · doi:10.1586/epr.10.109 · Cited by 252
Belov, M. E., Damoc, E., Denisov, E., Compton, P. D., Horning, S., Makarov, A. A., & Kelleher, N. L. (2013) · Analytical Chemistry · doi:10.1021/ac4029328 · Cited by 175
Unique insights to intrinsically disordered proteins provided by ion mobility mass spectrometry
Stuchfield, D., & Barran, P. (2018) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2018.01.007 · Cited by 72
Mass spectrometry: From plasma proteins to mitochondrial membranes
Robinson, C. V. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1820450116 · Cited by 53
Ion mobility in the pharmaceutical industry: an established biophysical technique or still niche?
Campuzano, I. D., & Lippens, J. L. (2018) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2017.11.008 · Cited by 42
Shepherd, D. A., Holmes, K., Rowlands, D. J., Stonehouse, N. J., & Ashcroft, A. E. (2013) · Biophysical Journal · doi:10.1016/j.bpj.2013.07.028 · Cited by 25
Metadata
- Authors
- Giles, K., Pringle, S. D., Worthington, K. R., Little, D., Wildgoose, J. L., & Bateman, R. H.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2004-09-13
- Volume
- 18
- Issue
- 20
- Pages
- 2401-2414
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2102574135
- Cited by
- 727
- References
- 17
- FWCI
- 3.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.